MR-JE-10_ to MR-JE-300_
Instructions and Cautions for
Safe Use of AC Servos
MR-JE Servo amplifier
Model
IB(NA)0300194ENG-P(2009)MEE
HEAD OFFICE: TOKYO BLDG MARUNOUCHI TOKYO 100-8310
Specifications are subject to change without notice.
P
General-Purpose AC Servo
Country/Region
USA
Germany
China
Korea
Japan
Sales office
Mitsubishi Electric Automation, Inc.
500 Corporate Woods Parkway, Vernon Hills, IL 60061, U.S.A.
Mitsubishi Electric Europe B.V. German Branch
Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany
Mitsubishi Electric Automation (China) Ltd.
Mitsubishi Electric Automation Center, No.1386 Hongqiao Road, Shanghai, China
Mitsubishi Electric Automation Korea Co., Ltd.
7F-9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu, Seoul 07528, Korea
Mitsubishi Electric Corporation
Tokyo Building, 2-7-3, Marunouchi, Chiyoda-ku, Tokyo 100-8310, Japan
Tel/Fax
Tel
Fax
Tel
Fax
Tel
Fax
Tel
Fax
Tel
: +1-847-478-2100
: +1-847-478-2253
: +49-2102-486-0
: +49-2102-486-1120
: +86-21-2322-3030
: +86-21-2322-3000
: +82-2-3660-9510
: +82-2-3664-8372/8335
: +81-3-3218-2111
Copyright©2013 Mitsubishi Electric Corporation All Rights Reserved.
Contents of the package
Unpack the product and check the rating plate to see if the servo motor is as you ordered.
Contents Quantity
Servo amplifier 1
MR-JE Servo amplifier Instructions and Cautions for Safe Use of AC Servos (This guide) 1
Rating plate
The following shows an example of rating plate prate for explanation of each item.
Serial number
Model
Capacity
Applicable power supply
Rated output
Standard, Manual number
Ambient temperature
IP rating
KC certification number,
The year and month of manufacture
Country of origin
KCC-REI-MEK-TC300A745G51 DATE: 2014-07
MR-JE-10A
AC SERVO
SER. S47001001
POWER
INPUT
OUTPUT
STD.: IEC/EN61800-5-1 MAN. : IB(NA)0300194
Max. Surrounding Air Temp. : 55°C
IP20
: 100W
: 3AC/AC200-240V 0.9A/1.5A 50/60Hz
: 3PH170V 0-360Hz 1.1A
TOKYO 100-8310, JAPAN MADE IN JAPAN
Warning plate
The following shows an example of warning plate.
Model
The following describes what each block of a model name
indicates. Not all combinations of the symbols are available.
Series
Rated output
Symbol
10
20
40
70
100
200
300
Rated output [kW]
0.1
0.2
0.4
0.75
1
2
3
Software special specification
Blank, Jn, Sn, or Un
(n = 00 to 999)
Hardware special specification
Blank or 2 to 5 digit alphanumeric
(RJ, ED, PX, RU, RZ, etc.)
Interface
Symbol
A(S)
B
C
Interface
General-purpose interface
SSCNET III/H
Ethernet interface
MR J
E1 ---0
1. About the manuals
To use the MELSERVO-JE series safely, read each instruction manual carefully.
1.1 MELSERVO-JE relevant manuals
This installation guide explains how to mount MR-JE servo amplifiers.
If you have any questions about the operation or programming of the equipment described in this guide, contact your
local sales office.
In addition, when you mount a protective device, specific technical skills which are not detailed in the guide will be
required.
1.2 Purpose of this guide
This installation guide explains the safe operation of MR-JE servo amplifiers for engineers of machinery manufacturers
and machine operators. For detailed information of the products, refer to each servo amplifier instruction manual.
2. About safety
This chapter explains safety of users and machine operators. Please read the chapter carefully before mounting the
equipment. In this installation guide, the specific warnings and cautions levels are classified as follows.
WARNING
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
CAUTION
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight injury to
personnel or may cause physical damage.
2.1 Professional engineer
Only professional engineers should mount MR-JE servo amplifiers.
Here, professional engineers should meet all the conditions below.
(1) Persons who took a proper training of related work of electrical equipment or persons who can avoid risk based on
past experience.
(2) Persons who have read and familiarized himself/herself with this installation guide and operating manuals for the
protective devices (e.g. light curtain) connected to the safety control system.
2.2 Applications of the devices
MR-JE servo amplifiers comply with the following standards.
IEC/EN 61800-5-1/GB 12668.501, IEC/EN/KN 61800-3/GB 12668.3
2.3 Correct use
Use the MR-JE servo amplifiers within specifications. Refer to each instruction manual for specifications such as
voltage, temperature, etc. Mitsubishi Electric Co. accepts no claims for liability if the equipment is used in any other way
or if modifications are made to the device, even in the context of mounting and installation.
WARNING
If you need to get close to the moving parts of the machine for inspection or others, ensure
safety by confirming the power off, etc. Otherwise, it may cause an accident.
It takes 15 minutes maximum for capacitor discharging. Do not touch the unit and terminals
immediately after power off.
2.3.1 Peripheral device and power wiring
The followings are selected based on IEC/EN 61800-5-1, UL 508C, and CSA C22.2 No. 274.
(1) Local wiring
The following table shows the stranded wire sizes [AWG] symbols rated at 75 °C/60 °C.
Table. Recommended wires
Servo amplifier (Note 3)
75 °C/60 °C stranded wire [AWG]
L1/L2/L3/
(Note 2)
P+/C
U/V/W/
(Note 1,2)
MR-JE-10_/MR-JE-20_/MR-JE-40_/MR-JE-70_/MR-JE-100_ (T)/
MR-JE-200_/MR-JE-300_
14/14
14/14 14/14
MR-JE-200_ (S) 12/12
Note 1. Select wire sizes depending on the rated output of the servo motors. The values in the table are sizes based on rated output of the servo
amplifiers.
2. The following shows the PE terminal specifications of the servo amplifier.
Screw size: M4
Tightening torque: 1.2 [N•m]
Recommended crimp terminals: R2-4 (Manufactured by JST)
Crimping tool: YPT-60-21 (Manufactured by JST)
3. "(S)" means 1-phase 200 V AC power input and "(T)" means 3-phase 200 V AC power input in the table.
(2) Selection example of MCCB and fuse
Use T class fuses or molded-case circuit breaker (UL 489 Listed MCCB) as the following table. The T class fuses
and molded-case circuit breakers in the table are selected examples based on rated I/O of the servo amplifiers.
When you select a smaller capacity servo motor to connect it to the servo amplifier, you can also use smaller
capacity T class fuses or molded-case circuit breaker than ones in the table. For selecting ones other than Class T
fuses and molded-case circuit breakers below and selecting a Type E Combination motor controller, refer to each
servo amplifier instruction manual.
Servo amplifier (Note) Molded-case circuit breaker (240 V AC) Fuse (300 V)
MR-JE-10_/MR-JE-20_/MR-JE-40_/MR-JE-70_ (T) NF50-SVFU-5A (50 A frame 5 A) 10 A
MR-JE-70_ (S)/MR-JE-100_ (T) NF50-SVFU-10A (50 A frame 10 A) 15 A
MR-JE-200_ (T)/MR-JE-300_ NF50-SVFU-15A (50 A frame 15 A) 30 A
MR-JE-100_ (S) NF50-SVFU-15A (50 A frame 15 A) 30 A
MR-JE-200_ (S) NF50-SVFU-20A (50 A frame 20 A) 40 A
Note. "(S)" means 1-phase 200 V AC power input and "(T)" means 3-phase 200 V AC power input in the table.
(3) Power supply
This servo amplifier can be supplied from star-connected supply with grounded neutral point of overvoltage
category III (overvoltage category II for 1-phase servo amplifiers) set forth in IEC/EN 60664-1. For the interface
power supply, use an external 24 V DC power supply with reinforced insulation on I/O terminals.
(4) Grounding
To prevent an electric shock, always connect the protective earth (PE)
terminal (marked
) of the servo amplifier to the protective earth (PE) of
the cabinet. Do not connect two grounding cables to the same protective
earth
PE
terminal. Alwa
s connect cables to the terminals one-to-one.
PE
terminal
PE
terminals
This product can cause a DC current in the protective earthing conductor. To protect direct/indirect contact using
an earth-leakage current breaker (RCD), only an RCD of type B can be used for the power supply side of the
product.
(5) Motor overload and Over temperature protection
Servo motors do not have the overheat protection function of own. The servo motors are protected by the servo
motor overheat protection function of the servo amplifiers (a protection characteristic based on 120 % of the rated
current). To provide the servo motor with overheat protection, use a magnetic contactor (electromagnetic switch)
with a thermal relay. Alternatively, install a thermal sensor or equivalent equipment near the rating plate of the
servo motor to check that the servo motor temperature is under 105 °C with sensing device. (Refer to Chapter 4)
2.3.2 EU compliance
The EC directives were issued to standardize the regulations of the EU countries and ensure smooth distribution of
safety-guaranteed products. The CE marking proves the compliance of the manufacturer with the EC directives, and this
marking also applies to machines and equipment incorporating servos.
(1) EMC requirement
MR-JE servo amplifiers comply with IEC/EN 61800-3. Install an EMC filter and surge protector on the primary side
of the servo amplifier. As for I/O signal wires (max. length 10 m) and encoder cables (max. length 50 m), use
shielded wires and ground the shields. However, when the encoder cable length is longer than 30 m for MR-JE-
70_ and MR-JE-100_, set a radio noise filter (FR-BIF) to the input power supply side of the servo amplifier. The
following shows recommended products.
EMC filter: Soshin Electric HF3000A-UN series
Surge protector: Okaya Electric Industries RSPD series
Radio noise filter: Mitsubishi Electric FR-BIF
The MR-JE series is not intended to be used with low-voltage distribution lines for household. If it is used in such
an environment, radio frequency interference may be generated. The installer shall provide a guide for Installation
and use, including recommended mitigation devices. To avoid the risk of crosstalk to signal cables, the installation
instructions shall either recommend that the power interface cable be segregated from signal cables.
Use the DC power supply installed with the amplifiers in the same cabinet. Do not connect the other electric
devices to the DC power supply.
(2) For Declaration of Conformity (DoC)
MITSUBISHI ELECTRIC EUROPE B.V. hereby declares that the servo amplifiers are in compliance with EC
directives (EMC directive (2014/30/EU), Low-voltage directive (2014/35/EU), and RoHS directive (2011/65/EU)).
For the copy of Declaration of Conformity, contact your local sales office.
2.3.3 USA/Canada compliance
This servo amplifier is designed in compliance with UL 508C and CSA C22.2 No. 274.
(1) Installation
The minimum cabinet size is 150% of MR-JE servo amplifier's volume. Also, design the cabinet so that the
ambient temperature in the cabinet is 55 °C or less. The servo amplifier must be installed in the metal cabinet.
Additionally, mount the servo amplifier on a cabinet that the protective earth based on the standard of IEC/EN
60204-1 is correctly connected. For environment, the units should be used in open type (UL 50) and overvoltage
category shown in table in section 8.1. The servo amplifier needs to be installed at or below pollution degree 2. For
connection, use copper wires.
(2) Short-circuit current rating (SCCR)
Suitable For Use On A Circuit Capable Of Delivering Not More Than 100 kA rms Symmetrical Amperes, 500 Volts
Maximum. For SCCR when using a Type E Combination motor controller, refer to each servo amplifier instruction
manual.
(3) Branch circuit protection
For installation in United States, branch circuit protection must be provided, in accordance with the National
Electrical Code and any applicable local codes.
For installation in Canada, branch circuit protection must be provided, in accordance with the Canada Electrical
Code and any applicable provincial codes.
2.3.4 South Korea compliance
This product complies with the Radio Waves Act (KC mark). Please note the following to use the product.
이 기기는 업무용 (A급) 전자파적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며, 가정외의 지역에서
사용하는 것을 목적으로 합니다.
(The product is for business use (Class A) and meets the electromagnetic compatibility requirements. The seller and the
user must note the above point, and use the product in a place except for home.)
2.4 General cautions for safety protection and protective measures
Observe the following items to ensure proper use of the MR-JE servo amplifiers.
(1) For installing systems, only qualified personnel and professional engineers should perform.
(2) When mounting, installing, and using the MR-JE servo amplifier, always observe standards and directives
applicable in the country.
2.5 Disposal
Disposal of unusable or irreparable devices should always occur in accordance with the applicable country-specific
waste disposal regulations. (Example: European Waste 16 02 14)
2.6 Lithium battery transportation
To transport lithium batteries, take actions to comply with the instructions and regulations such as the United Nations
(UN), the International Civil Aviation Organization (ICAO), and the International Maritime Organization (IMO).
The batteries (MR-BAT6V1SET-A and MR-BAT6V1) are assembled batteries from two batteries (lithium metal battery
CR17335A) which are not subject to the dangerous goods (Class 9) of the UN Recommendations.
3. Mounting/dismounting
Installation direction and clearances
CAUTION
The devices must be installed in the
specified direction. Not doing so may
cause a malfunction.
Mount the servo amplifier on a cabinet
which meets IP54 in the correct vertical
direction to maintain pollution degree 2.
10 mm
or more
80 mm or longer
for wiring
10 mm
r more
Top
Bottom
40 mm
or more
40 mm
or more
Cabine
Servo amplifier
Servo amplifier
Cabine
4. Electrical Installation and configuration diagram
WARNING
Turn off the molded-case circuit breaker (MCCB) to avoid electrical shocks or damages to the
product before starting the installation or wiring.
CAUTION
Connecting a servo motor for different axis to U, V, W, or CN2 of the servo amplifier may cause
a malfunction.
Securely connect the cables in the specified method and tighten them with the specified torque.
Otherwise, the servo motor may operate unexpectedly.
The following shows representative configuration examples to conform to the IEC/EN/UL/CSA standards.
(1) 3-phase input
MCCB
or fuse
Controller
Encoder cable
(3-phase
230 V AC)
Powe
supply
(3-phase
00 V AC)
Transformer (Note 2)
(star-connected)
PE
MC
Servo amplifier
Cabinet side
Machine side
Encoder
Servo motor
L1
U/V/W/PE
CN2
CN1
L2L3
Sensing device
(2) 1-phase input
MCCB
or fuse
Controller
Encoder cable
(1-phase
230 V AC)
Powe
supply
(3-phase
00 V AC)
Transformer (Note 2)
(star-connected)
PE
(Note 1)
MC
Servo amplifier
Cabinet side
Machine side
Encoder
Servo motor
L1
U/V/W/PE
CN2
CN1
L2L3
Sensing device
Note 1. For the MR-JE-200_ servo amplifiers, connect the power supply to L1 and L2. Leave L3 open.
2. Supply neutral needs to be earthed.
The connectors described by rectangles are safely separated from the main circuits described by circles.
Use MR-JE servo amplifiers in combination with HG series or HJ series servo motors.
5. Signals
5.1 Signal
The following shows CN1 connector signals of MR-JE-
10A as a typical example. For the other connector
details, refer to each servo amplifier instruction manual.
1
3
5
7
9
11
13
15
17
19
21
23
25
2
4
6
8
10
12
14
16
18
20
22
24
TLA
MO1
MO2
27
29
31
33
35
37
39
41
43
45
47
49
26
28
30
32
34
36
38
40
42
44
46
48
50
LG
LA
LG
LAR
LB
LG
LBR
LZ OP
LZR LG
EM2
DICOM
DICOM
DOCOM
DOCOM
ALM
CN1
PP
OPC
PG
SON
CR
LSP
RES
ZSP
RDINP
LSN
NP
NG
This is in position control mode
TRE
SDN
SDP
RDP
RDN
5.2 I/O device
The following shows typical I/O devices of MR-JE-_A. For the
other devices, refer to each servo amplifier instruction
manual.
Input device
Symbol Device Connector Pin No.
SON Servo-on 15
RES Reset 19
CR Clear
CN1
41
EM2 Forced stop 2 42
LSP Forward rotation stroke end 43
LSN Reverse rotation stroke end 44
Output device
Symbol Device Connector Pin No.
ZSP Zero speed detection 23
INP In-position
CN1
24
ALM Malfunction 48
RD Ready 49
Power supply
Symbol Device Connector Pin No.
DICOM Digital I/F power supply input 20, 21
DOCOM Digital I/F common CN1 46, 47
SD Shield Plate
6. Maintenance and service
WARNING
To avoid an electric shock, only qualified personnel should attempt inspections. For repair and
parts replacement, contact your local sales office.
6.1 Inspection items
It is recommended that the following points periodically be checked.
(1) Check for loose screws on the protective earth (PE) terminal. Retighten any loose screws. (tightening torque: 1.2
N•m)
(2) Servo motor bearings, brake section, etc. for unusual noise.
(3) Check the cables and the like for scratches or cracks. Perform periodic inspection according to operating
conditions.
(4) Check that the connectors are securely connected to the servo motor.
(5) Check that the wires are not coming out from the connector.
(6) Check for dust accumulation on the servo amplifier.
(7) Check for unusual noise generated from the servo amplifier.
(8) Check the servo motor shaft and coupling for connection.
(9) Make sure that the emergency stop circuit operates properly such that an operation can be stopped immediately
and a power is shut off by the emergency stop switch.
6.2 Parts having service life
Service life of the following parts is listed below. However, the service life varies depending on operation and
environment. If any fault is found in the parts, they must be replaced immediately regardless of their service life. For
parts replacement, please contact your local sales office.
Part name Life guideline
Smoothing capacitor 10 years (Note 3)
Relay
Number of power-on, forced stop, and controller forced stop times:
100,000 times
Cooling fan 50,000 hours to 70,000 hours (7 years to 8 years)
Battery backup time (Note 1)
Approximately 20,000 hours (equipment power supply: off, ambient temperature: 20 °C)
Battery life (Note 2)
5 years from date of manufacture
Note 1. The time is for using MR-BAT6V1SET-A. For details and other battery backup time, refer to each servo amplifier instruction manual.
2. Quality of the batteries degrades by the storage condition. The battery life is 5 years from the production date regardless of the connection
status.
3. The characteristic of smoothing capacitor is deteriorated due to ripple currents, etc. The life of the capacitor greatly depends on ambient
temperature and operating conditions. The capacitor will be the end of its life in 10 years of continuous operation in air-conditioned
environment (ambient temperature of 40 °C or less for use at the maximum 1000 m above sea level, 30 °C or less for over 1000 m to 2000
m).
7. Transportation and storage
CAUTION
Transport the products correctly according to their mass.
Stacking in excess of the limited number of product packages is not allowed.
For detailed information on the battery’s transportation and handing refer to each servo amplifier
instruction manual.
Install the product in a load-bearing place of servo amplifier and servo motor in accordance with
instruction manual.
Do not put excessive load on the machine.
Do not hold the lead of the built-in regenerative resistor, cables, or connectors when carrying the
servo amplifier. Otherwise, it may drop.
When you keep or use it, please fulfill the following environment.
Item Environment
Ambient
temperature
Operation [°C] 0 to 55 Class 3K3 (IEC/EN 60721-3-3)
Transportation (Note) [°C] -20 to 65 Class 2K12 (IEC/EN 60721-3-2)
Storage (Note) [°C] -20 to 65 Class 1K4 (IEC/EN 60721-3-1)
Ambient humidity Operation, transportation, storage 5 %RH to 90 %RH
Vibration
resistance
Test condition
10 Hz to 57 Hz with constant amplitude of 0.075 mm
57 Hz to 150 Hz with constant acceleration of 9.8 m/s
2
to IEC/EN 61800-5-1
(Test Fc of IEC 60068-2-6)
Operation
5.9 m/s
2
Transportation (Note)
Class 2M3 (IEC/EN 60721-3-2)
Storage
Class 1M2 (IEC/EN 60721-3-2)
Pollution degree 2
IP rating
IP20 (IEC/EN 60529)
Open type (UL 50)
Altitude
Operation, storage Max. 2000 m above sea level (MR-JE-_AS: Max. 1000 m above sea level)
Transportation Max. 10000 m above sea level
Note. In regular transport packaging
8.Technical data
8.1 MR-JE servo amplifier
Item
MR-JE-10_/MR-JE-20_/MR-JE-40_/MR-JE-70_/
MR-JE-100_/MR-JE-200_
MR-JE-300_
Power
supply
Line voltage
3-phase or
1-phase 200 V AC to 240 V AC, 50 Hz /60 Hz
3-phase 200 V AC to 240 V AC, 50 Hz/60 Hz
Interface (SELV) 24 V DC, (required current capacity: MR-JE-_A(S), 300 mA; MR-JE-_B, 300 mA; MR-JE-_C, 300 mA) (Note)
Control method Sine-wave PWM control, current control method
Pollution degree 2 (IEC/EN 60664-1)
Overvoltage category 1-phase 200 V AC: II (IEC/EN 60664-1), 3-phase 200 V AC: III (IEC/EN 60664-1)
Protective class I (IEC/EN 61800-5-1)
Short-circuit current rating (SCCR) 100 kA
Note. This will be 100 mA for the MR-JE-_B servo amplifiers manufactured in April 2016 or before (May 2016 or before for amplifiers manufactured in
China).
8.2 Dimensions/mounting hole process drawing
WD
H Front Side
Servo amplifier
Variable dimensions [mm]
Mass [kg]
W
H
D
MR-JE-10_/MR-JE-20_/MR-JE-40_ 50 168 135 0.8
MR-JE-70_/MR-JE-100_ 70 168 185 1.5
MR-JE-200_/MR-JE-300_ 90 168 195 2.1
da
c
b
c
a1
e
Servo amplifier
Variable dimensions [mm]
Screw size
e
a a1 b c d
MR-JE-10_/MR-JE-20_/MR-JE-40_ 6 6 156 ± 0.5 6
M5
MR-JE-70_/MR-JE-100_ 22 22 156 ± 0.5 6 42 ± 0.3 M5
MR-JE-200_/MR-JE-300_ 6 45 156 ± 0.5 6 78 ± 0.3 M5
[Warranty]
1. Warranty period and coverage
We will repair any failure or defect hereinafter referred to as "failure" in our FA equipment hereinafter referred to as the
"Product" arisen during warranty period at no charge due to causes for which we are responsible through the distributor from
which you purchased the Product or our service provider. However, we will charge the actual cost of dispatching our engineer
for an on-site repair work on request by customer in Japan or overseas countries. We are not responsible for any on-site
readjustment and/or trial run that may be required after a defective unit are repaired or replaced.
[Term]
For terms of warranty, please contact your original place of purchase.
[Limitations]
(1) You are requested to conduct an initial failure diagnosis by yourself, as a general rule. It can also be carried out by us or our
service company upon your request and the actual cost will be charged. However, it will not be charged if we are responsible
for the cause of the failure.
(2) This limited warranty applies only when the condition, method, environment, etc. of use are in compliance with the terms and
conditions and instructions that are set forth in the instruction manual and user manual for the Product and the caution label
affixed to the Product.
(3) Even during the term of warranty, the repair cost will be charged on you in the following cases.
(i) a failure caused by your improper storing or handling, carelessness or negligence, etc., and a failure caused by your hardware or software
problem
(ii) a failure caused by any alteration, etc. to the Product made on your side without our approval
(iii) a failure which may be regarded as avoidable, if your equipment in which the Product is incorporated is equipped with a safety device
required by applicable laws and has any function or structure considered to be indispensable according to a common sense in the industry
(iv) a failure which may be regarded as avoidable if consumable parts designated in the instruction manual, etc. are duly maintained and
replaced
(v) any replacement of consumable parts (battery, fan, smoothing capacitor, etc.)
(vi) a failure caused by external factors such as inevitable accidents, including without limitation fire and abnormal fluctuation of voltage, and
acts of God, including without limitation earthquake, lightning and natural disasters
(vii) a failure generated by an unforeseeable cause with a scientific technology that was not available at the time of the shipment of the Product
from our company
(viii) any other failures which we are not responsible for or which you acknowledge we are not responsible for
2. Term of warranty after the stop of production
(1) We may accept the repair at charge for another seven (7) years after the production of the product is discontinued. The
announcement of the stop of production for each model can be seen in our Sales and Service, etc.
(2) Please note that the Product (including its spare parts) cannot be ordered after its stop of production.
3. Service in overseas countries
Our regional FA Center in overseas countries will accept the repair work of the Product. However, the terms and conditions of
the repair work may differ depending on each FA Center. Please ask your local FA center for details.
4. Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:
(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.
(3) Special damages and secondary damages whether foreseeable or not, compensation for accidents, and compensation for
damages to products other than Mitsubishi products.
(4) Replacement by the user, maintenance of on-site equipment, start-up test run and other tasks.
5. Change of Product specifications
Specifications listed in our catalogs, manuals or technical documents may be changed without notice.
6. Application and use of the Product
(1) For the use of our AC Servo, its applications should be those that may not result in a serious damage even if any failure or
malfunction occurs in AC Servo, and a backup or fail-safe function should operate on an external system to AC Servo when
any failure or malfunction occurs.
(2) Our AC Servo is designed and manufactured as a general purpose product for use at general industries.
Therefore, applications substantially influential on the public interest for such as atomic power plants and other power plants
of electric power companies, and also which require a special quality assurance system, including applications for railway
companies and government or public offices are not recommended, and we assume no responsibility for any failure caused
by these applications when used.
In addition, applications which may be substantially influential to human lives or properties for such as airlines, medical
treatments, railway service, incineration and fuel systems, man-operated material handling equipment, entertainment
machines, safety machines, etc. are not recommended, and we assume no responsibility for any failure caused by these
applications when used.
We will review the acceptability of the abovementioned applications, if you agree not to require a specific quality for a specific
application. Please contact us for consultation.