FCA3000 and FCA3100 Series Timer/Counter/Analyzer
MCA3000 Series Microwave Counter/Analyzer
ZZZ
Quick Start User Manual
*P071278702*
071-2787-02
FCA3000 and FCA3100 Series Timer/Counter/Analyzer
MCA3000 Series Microwave Counter/Analyzer
ZZZ
Quick Start User Manual
xx
www.tektronix.com
071-2787-02
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are
protected by na
tional copyright laws and international treaty provisions.
Tektronix pro
ducts are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all
previously published material. Specications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
LabVIEW, National Instruments, NI, and SignalExpress are trademarks of National Instruments.
TimeView is a trademark of Pendulum Instruments AB.
Contacting Tektronix
Tektronix, Inc.
14150 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200.
Worldwide, visit www.tektronix.co m to nd contacts in your area.
Warranty
Tektronix warrants that this product will be free from defects in materials and workmanship for a period of three (3) y ears from the date
of shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective
product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Parts, modules and
replacement products used by Tektronix for warranty work may be new or reconditioned to like new performance. All replaced
parts, modules and products become the property of Tektronix.
In order to obtain service under this warranty, Cu stomer must notify Tektronix of the defect before the expiration of the w arranty period
and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the
defective product to the service center designated by Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the
product to Customer if the shipment is to a location w ithin the country in which the Tektronix service center is located. Customer shall
be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and
care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel
other than Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or
connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-Tektronix supplies; or
d) to service a product that has been modied or integrated with other products when the effect of such modication or integration
increases the time or difculty of s ervicing the product.
THIS WARRANTY IS GIVEN BY TEK TR ON IX WITH RESPECT TO TH E PRODUCT IN LIEU OF ANY OTHER WARRANTIES,
EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM A NY IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. TE KTRONIX' RES P ONSIBILITY TO REPAIR OR REPLACE D EFECTIVE PRODUCTS
IS THE SOLE AND EXCLUSIVE REME DY PROVIDED TO THE CUSTOMER FOR BR EAC H OF THIS WARRANTY. TEKTRONIX
AND ITS VENDORS WILL N OT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES
IRRESPECTIVE O F WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH
DAMAGES.
[W4 15AUG04]
Table of Content
s
Table of Contents
Important safety information .......................................................................................................... iii
General safe
ty summary......................................................................................................... iii
Service safety summary ......................................................................................................... v
Terms in this manual ...... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... . v
Symbols and
terms on the product .... ... ... ... ... ... ... ... .. . .. ... ... ... ... ... ... ... ... .................... ... ... .............. v
Compliance Information ............................................................................................................... vi
EMC Compliance................................................................................................................. vi
Safety Co m
pliance.............................................................................................................. vii
Environmental Considerations................................................................................................. viii
Preface................................................................................................................................. ix
Key Featur
es ..................................................................................................................... ix
Documentation ...................................................................................................................x
Conventions Used in This Manual........... ... ... ... ... ... ... ... ... ... .. ... ... ... ... ... ... ... ... ... .................... ... ... .. x
Installa
tion.............................................................................................................................. 1
Unpacking the Instrument ....................................................................................................... 1
Operating Considerations........................................................................................................ 1
Powerin
g the Instrument On and Off............................................................................................ 2
Functional Check.... ... ... ... .................... ... ... .................... ... ... ... ... ... ... ... ... .. . .. ... ... ... ... ... ... ... ... .2
Getting Acquainted with Your Instrument .............................................................................................3
Front P
anel .... ... ... ........... ........... ... ... ... .. ... ... ... ........... ........... ... ... ... ..... ... ... ... ........... ........... 3
Rear Panel .... ... ................. ... ................. ... ... ... ... ... ... .. ... ... ... ... ... ... ................. ... .................4
Input Connectors . ... ... ... ... ... ... ... ... ... ... ... . .. . .. . ... ... ... ... ... ... ... ... ... ... ... ... ... ......................... ... ... . .5
Contro
ls........................................................................................................................... 6
Main Screen......................................................................................................................9
Application Examples................................................................................................................. 12
Resto
re Default Settings........................................................................................................ 12
Basic Measurements............................................................................................................ 12
Math Measurement ............................................................................................................. 13
Limi
t Testing ..................................................................................................................... 13
Two-Channel Measurements ... ........... ........... ... ... .. ... ... ... ........... ........ ... ... ... .. ... ... ... ........ .......... 15
Input C Measurements.... ... ... ... ... .............. ... .............. ... ... ... ... .. . .. ... ... ... ... .............. ... ............. 15
Sav
e an Instrument Setup ...................................................................................................... 16
Connectivity . .. . ... ... ... ... ... ... ... ... ... ................ ... ... ... ................... ... ... ... ... ... ... ... ... . .. . ... ... ... ... ........ 18
FCA3000, FCA3100, and MCA3000 Series Quick Start U ser Manual i
Table of Content
s
ii FCA3000, FCA3100, and MCA3000 Series Q uick Start User Manual
Important safet
y information
Important saf
ety information
This manual contains information and warnings that must be followed by the user for safe operation and to keep the
product in a safe condition.
To safely perform service on this product, additional information is provided at the end of this section. (See page v,
Service safety summary.)
General safety summary
Use the product only as specied. Review the following safety precautions to avoid injury and prevent damage to this product
or any products connected to it. Carefully read all instructions. Retain these instructions for future reference.
Comply with local and national safety codes.
For c orrect and safe operation of the product, it is essential that you follow generally accepted safety procedures in addition
to the safety precautions specied in this manual.
The product is designed to be used by trained personnel only.
Only qualied personnel who are aware of the hazards involved should remove the cover for repair, maintenance, or
adjustment.
Before use, always check the product with a known s ource to be sure it is operating correctly.
This product is not intended for detection of hazardous voltages.
Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.
While using this product, you may need to access other parts of a larger system. Read the safety sections of the other
component manuals for warnings and cautions related to operating the system.
When incorporating this equipment into a system, the safety of that system is the responsibility of the assembler of the system.
To avoid re or personal injury
Use proper power cord. Use only the power cord specied for this product and certied for the country of use.
Do not use the provided power cord for other products.
Ground the product. This product is grounded through the grounding conductor of the power cord. To avoid electric
shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output
terminals of the product, make sure that the product is properly grounded.
Do not disable the power cord grounding connection.
Power disconnect. The power cord disconnects the product from the power source. See instructions for the location.
Do not position the equipment so that it is difcult to access the power cord; it m ust remain accessible to the user at all
times to allow for quick disconnection if needed.
Connect and disconnect properly. Do not connect or disconnect probes or test leads while they are connected
to a voltage source.
Observe all terminal ratings. To avoid re or shock hazard, observe all ratings and markings on the product. Consult
the product manual for further ratings information before m aking connections to the product.
FCA3000, FCA3100, and MCA3000 Series Quick Start U ser Manual iii
Important safet
y information
Do not apply a potential to any terminal, i ncluding the common terminal, that exceeds the maximum rating of that terminal.
The measuring terminals on this product are not rated for connection to mains or Category II, III, or IV circuits.
Do not operate without covers. Do not operate this product w ith covers or panels removed, or with the case open.
Hazardous voltage exposure is possible.
Avoid expose
d circuitry.
Do not touch exposed connections and components when power is present.
Do not operate with suspected failures. If you suspect that there is damage to this product, have it inspected by
qualied service personnel.
Disable the product if it is damaged. Do not use the product if it is damaged or operates incorrectly. If in doubt about safety of
the product, turn it off and disconnect the power cord. Cl early mark the product to prevent its further operation.
Use only specied replacement parts.
Use proper fuse. Use only the fuse type and rating specied for this product.
Do not operate in wet/damp conditions. Be aware that condensation may occur if a unit is moved from a cold to a
warm environment.
Do not operate in an explosive atmosphere.
Keep product surfaces clean and dry.
Remove the input signals before you clean the product.
Provide proper ventilation. Refer to the installation instructions in the manual for details on installing the product
so it has proper ventilation.
Slots and openings are provided for ventilation and should nev er be covered or otherwise obstructed. Do not push objects
into any of the openings.
Provide a safe working environment. Always place the product in a location convenient for viewing the display
and indicators.
Be sure your work area meets applicable ergonomic standards. C onsult with an ergonomics professional to avoid stress
inju
ries.
iv FCA3000, FCA3100, and MCA3000 Series Q uick Start User Manual
Important safet
y information
Servicesafetysummary
The Service safety summary section contains additional information required to s afely perform service on the product. Only
qualied personnel should perform se rvice procedures. Read this Service safety summary and the General safety summary
before performing any service procedures.
To avoid electric shock. Do not touch exposed connections.
Do not service alone. Do not perform internal service or adjustments of this product unless another person capable of
rendering rst aid and resuscitation is present.
Disconnect power. To avoid electric shock, switch off the product power and disconnect the power cord from the mains
power before removing any covers or p
anels, or opening the case for servicing.
Use care when servicing with power on. Dangerous voltages or currents may exist in this product. Disconnect
power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing
components.
Verify safety after repair. Always recheck ground continuity and mains dielectric strength after performing a repair.
Terms in this manual
These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
Symbols and terms on the product
These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the marking.
WARNING indicates an injury hazard not immediately accessible as you read the m arking.
CAUTION i ndicates a hazard to property including the product.
When this symbol is marked on the product, be sure to consult the manual to nd out the nature of the
potential hazards and any actions which have to be taken to avoid them. (This symbol may also be used
to
refer the user to ratings in the manual.)
The following symbol(s) may appear on the product:
FCA3000, FCA3100, and MCA3000 Series Quick Start U ser Manual v
Compliance Info
rmation
Compliance In
formation
This section lists the EMC (electromagnetic compliance), safety, and environment al standards with which the instrument
complies.
EMC Compliance
EC Declarati
on of Conformity EMC
Meets intent of Directive 2004/108/EC for Electromagnetic Compatibility. Compliance was demonstrated to the following
specications as listed in the Ofcial Journal of the European Communities:
EN 61326-1, EN 61326-2-1. EMC requirements for electrical equipment for measurement, control, and laboratory use.
123
CISPR 11; IEC 61000-4-2: IEC 61000-4-3
4
; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6
4
; IEC 61000-4-11
5
EN 61000-
3-2, EN 61000-3-3.
European contact.
Tektronix UK, Ltd.
Western Peninsula
Western Road
Bracknell, RG12 1RF
1
This pro
duct is intended for use in nonresidential areas only. Use in residential areas may cause electromagnetic interference.
2
Emissions which exceed the levels required by this standard may occur when this equipment is connected to a test object.
3
For compliance with the EMC standards listed here, high quality shielded interface cables should be used.
4
With a 10 MHz 0.1 Vp-p sine wave signal applied to the A or B input channels, the instrument's frequency readout value can
typically vary up to ±1 Hz beyond the inherent base variance, when the instrument is subjected to the elds and signals as dened
in the IEC 61000-4-3 and IEC 61000-4-6 tests.
5
Performance Criterion C applied at the 70%/25 cycle Voltage-Dip and the 0%/250 cycle Voltage-Interruption test levels
(IEC 61000-4-11).
Australia / New Zealand Dec laration of Conformity EMC
Compl
ies with the EMC provision of the Radiocommunications Act per the following standard, in accordance with ACMA:
CISPR
11
Australia / New Zealand contact.
Baker & McKenzie
Level 27, AMP Centre
50 Bridge Street
Sydney NSW 2000, Australia
vi FCA3000, FCA3100, and MCA3000 Series Q uick Start User Manual
Compliance Info
rmation
Safety Compliance
This section lists the safety standards with which the product complies and other safety compliance information.
EU Declaration of Conformity Low Voltage
Compliance was demonstrated to the following specication as listed in the Ofcial Journal of the European Communities:
Low Voltage Directive 2006/95/EC.
EN 61010-1
U.S. Natio
nally R ecognized Testing Laboratory Listing
UL 61010-1
Canadian Certication
CAN/CSA
-C22.2 No. 61010-1
Additional Compliances
IEC 61010-1
Equipment type
Test and measuring equipment.
Safety class
Class 1 grounded product.
Pollution degree rating
Pollution Degree 2 (as dened in IEC 61010-1). R ated for indoor, dry location use only.
Ma
ins overvoltage category rating
Overvoltage category II (as dened in IEC 61010-1).
FCA3000, FCA3100, and MCA3000 Series Quick Start U ser Manual vii
Compliance Info
rmation
Environmental Considerations
This section provides information about the environmental impact of the product.
Product End-of-Life Handling
Observe the following guidelines when recycling an instrument or component:
Equipment recycling. Production of this equipment required the extraction and use of natural resources. The equipment
may contain s ubstances that could be harmful to the environment or human health if improperly handled at the product’s
end of life. To avoid release of such substances into the environment and to reduce the use of natural resources, we
encourage you to recycle this product in an appropriate syste m that will ensure that most of the materials are reused
or recycled appropriately.
This symbol indicates that this product complies with the applicable European Union requirements according
to Directives 2012/19/EU and 2006/66/EC on waste electrical and electronic equipment (WEEE) and
batteries. For information about recycling options, c heck the Support/Service section o f the Tektronix Web
site (www.tektronix.com).
Restriction of Hazardous Substances
This product is classied as an industrial monitoring and control instrument, and is not required to comply with the substance
restric
tions of the recast RoHS Directive 2011/65/EU until July 22, 2017.
viii FCA3000, FCA3100, and MCA3000 Series Quick Start User Manual
Preface
Preface
This manual describes the installation and basic operati ons of the FCA3000 Series, FCA3100 Series, and MCA 3000 Series
instruments. For more detailed information see the FCA3000 Series, F CA3100 Series, and MCA3000 Series User Manual
(provided as a PDF le on the product CD). This m anual supports the following instruments:
FCA3000 S eries: FCA3000, FCA3003, and FCA3020
FCA3100 S eries: FCA3100, FCA3103, and FCA3120
MCA3000 Series: MCA3027 and MCA3040
Key Features
Wide measu
rement frequency range to 40 GHz
Fastest mi
crowave counter on the market (25 ms acquisition time)
Industry’
s only frequency counter with a graphical display
High reso
lution down to 50 ps single shot (time), o r 12 digits/s (frequency)
Simultan
eous display of signal frequency and voltage parameters
Trigger s
ensitivity of 15 mVrms from DC to 200 MHz
Voltage
resolution to 1 mV
Fast USB
/GPIB bus transfer speeds, up to 15k measurements per second (block mode)
Zero-de
ad time frequency/period measurements
Best ov
en-controlled crystal oscillator (OCXO) time base options (1.5 E-8/year)
MCA300
0 S eries offers microwave CW frequency measurements and very short burst measurements down to 40 ns
Progra
mmable Pulse output from 0.5 H z to 50 MHz (FCA3100 Se ries)
10 MHz
reference output oscillator
Measu
rement Statistics Mode
Histo
gram Mode
Tend
Plot mode
Fron
t or rear input connection options
FCA3000, FCA3100, and MCA3000 Series Quick Start U ser Manual ix
Preface
Documentation
Review the following for the location of different types of information available for this product.
To read about Use these documents
Installation and Operation (overviews) Quick Start User Manual. Provides general operating information.
In-Depth Operation and User Interface Help User Manual (on the documentation browser disc). Provides detailed
instructions for using instrument functions.
Programmer Commands Programmer M anual (on the documentation browser disc). Includes GPIB
command syntax.
Analysis and Connectivity Tools National Instruments SignalView Express CD and the Connectivity
Installation Instructions (on the documentation browser disc).
Conventions Used in This Manual
The following icons are used throughout this manual.
Sequence
Step
Front pa
nel
power
Connect
power
USB
Sequential button pushes are separated with a > symbol. For example, Meas > Pulse > Width Positive > A means to push
the Meas button, the Pulse menu button, the Width Positive menu button, and then the A menu button
x FCA3000, FCA3100, and MCA3000 Series Quick Start User Manual
Installation
Installation
Unpacking the Instrument
Unpack the instrument and check that you received all items listed as Standard Accessories. C heck the Te ktronix Web site
(www.tektronix.com) for the most current information, recommended accessories, instrument options, and upgrades.
Standard Accessories
Accessory
Tektronix part
number
FCA3000 and FCA3100 Series Timer/Counter/Analyzer, MCA3000 Series Microwave
Counter/Analyzer Quick Start User Manual (English/S implied Chinese/Japanese)
071-2787-xx
Product documentation CD-ROM
063-4288-xx
NI LabV IEW SignalExpress CD-ROM
063-4253-xx
Power cord
Country-specic
Type-N male to BNC adapter (FCA3003, FCA3020, FCA3103, and FCA3120 only) N/A
Certicate of Calibration N/A
Operating Considerations
Pleas
e verify that the area in which you will use the instrument meets the following operating requirements:
Requirement Description
Clearance Top and bottom: 0 mm (0 in)
Left
and right side: 51 mm (2 in)
Rear: 51 mm (2 in)
Lin
ePower
100 240 VAC ±10%, CAT II: 50 400 Hz ±10%: 40 W
Tem
perature
Operating: 0 °C to +50 °C (32 °F to 122 °F)
Nonoperating: –40 °C to +71 °C (–40 °F to +160 °F)
Humidity
+1Cto+3C(5Fto8F):5%to95%
+3
0 °C to +40 °C (86 °F to 104 °F): 5% to 75%
+40 °C to +50 °C (104 °F to 122 °F): 5% to 45%
Altitude (maximum) 2000 m (6500 feet)
M
aximum input voltage without
damage, Input A and Input B
50 :12V
rms
,35V
peak
for duty factor less than 0.1%
1M, 1X attenuator: 350 V (DC + AC pk) to 440 Hz, falling to 12 V
rms
at 1 M Hz
1M, 10X attenuator: 350 V (DC + AC p k) to 440 Hz, falling to 12 V
rms
at 1 MHz
Maximum input level without
damage, Input C
FCA3003, FCA3103: +34 dBm (12 V
rms
)
FCA3020, FCA3120: +27 dBm (5 V
rms
)
MCA3027, MCA3040: +18 dBm (1.78 V
rms
)
FCA3000, FCA3100, and MCA3000 Series Quick Start U ser Manual 1
Installation
Powering the Instrument On and Off
This instrument operates from a single-phase power source with the neutral conductor at o r near earth ground. (See
page 1, Operating C onsiderations.) A protective ground connection through the grounding conductor in the power cord is
essential for safe operation.
Functional Check
1. Power on the instrument
2. Push User Opt > Test.
3. Push the Test Mode menu button and select All.
4. Push the Start test menu button. Verify that all tests pass.
5. Push the OK menu button to return to the previous measurements display.
6. Connect a 50 cable from the 10 MHz Output connector on the rear panel to the Input A connector on the front panel.
7. Push Input A and select 50 input impedance.
8. Push Meas > Freq > Freq > A . The instrument should read 10 MHz.
2 FCA3000, FCA3100, and MCA3000 Series Quick Start User Manual
Getting Acquain
tedwithYourInstrument
Getting Acqua
inted with Your Instrument
Front Panel
1. P ower button (See page 6, Power Button.)
2. Main screen (See page 9, Main Screen.)
3. Measurement buttons (See page 6, Measurement Buttons.)
4. Navigation buttons (See page 7, Navigation Buttons.)
5. Input connectors (See page 5, Input Connectors.)
6. K eypad buttons (See page 7, Keypad Buttons.)
FCA3000, FCA3100, and MCA3000 Series Quick Start U ser Manual 3
Getting Acquain
ted with Your Instrument
Rear Panel
1. Pulse Out
put connector (FCA3100 Series only). (See page 5, Preventing ESD.)
2. ID label,
including model, serial, installed options, and instrument electrical ratings.
3. Line pow
er connector.
4. USB 2.0 1
2 Mb/s port to connect to PC.
5. GPIB por
t to connect to controller.
6. Option
al input connectors (a factory-installed option that moves the front panel input connectors to the rear panel). Not
available for MCA3000 Series instruments. (See page 5, Preventing ESD.)
7. External Arm Input connector (for external arming (synchronization) of measurements). The main inputs A and B can
also be selected for measurement arming from the Settings Menu. (See page 5, Preventing ESD .)
8. External Reference Input connector (If the Measurement Reference is s et to Auto in the Settings Menu, this input is
autom
atically selected, provided a valid signal is present). (See page 5, Preventing ESD.)
9. 10 MHz
Output connector. Provides a reference signal derived from the active measurement reference (internal or
external reference). The measurement reference source is set in the Settings Menu. (See page 5, Preventing ESD.)
4 FCA3000, FCA3100, and MCA3000 Series Quick Start User Manual
/