Avent SCF303/01 ユーザーマニュアル

カテゴリー
搾乳器
タイプ
ユーザーマニュアル
SCF303
使用产品前请仔细阅读本使用说明书
保留备用
EN User manual 2 ZH-CN
用户手册
24
3
English
10 Ordering accessories 20
11 Recycling 21
12 Guarantee and service 21
13 Troubleshooting 22
Table of Contents
1 Important 4
Electromagnetic Fields (EMF) 6
2 Introduction 6
Overview 7
Control panel 8
3 Cleaning and sterilising 9
4 Assembling 10
5 Using your pump 12
Before using the pump 12
To begin pumping 12
To pause pumping 16
Storing your breast milk 16
Feeding your baby with
expressed breast milk 17
Keeping your breast pump
sterile for travel 18
6 Hints to help you succeed 18
7 When to express milk 19
Right times of the day to
express your milk 19
8 Storage 20
9 Compatibility 20
4
English
The power cord is irreplaceable.
Discard it if is damaged,
including the power adapter.
Only use accessories
recommended by Philips Avent.
Only use the power adapter
supplied with the product.
Make sure the breast pump,
including the power adapter, is
not exposed to extreme heat or
placed in direct sunlight.
Do not use the breast pump
outdoors.
There are no user serviceable
parts inside the pump. Do not
attempt to open, service, or
repair the breast pump yourself.
The parts of the pump which
come directly into contact with
milk are personal care items,
and should not be shared
between mothers.
Do not attempt to remove the
pump body from the breast
while under vacuum. Switch
the breast pump o, and break
the seal between your breast
and the pump funnel with your
nger, then remove the pump
from your breast. You can also
pull o the silicone tube from
the motor or the cap to release
the vacuum.
Never use while pregnant as
pumping can induce labor.
Never use when sleepy or
drowsy.
This appliances can be used by
persons with reduced physical,
sensory or mental capabilities
or lack of experience and
knowledge if they have
1 Important
Read this user manual carefully
before using your Philips Avent
twin electronic breast pump, and
save the user manual for future
reference. You can also nd this
user manual at Philips website:
www.philips.com/support.
Warning
Always unplug from the power
socket immediately after use.
Do not use the breast pump
while bathing.
Do not place or store the breast
pump where it can fall or be
pulled into a bath or sink.
Do not place or drop the pump
motor, silicone tube, and power
adapter into water or other
liquids.
Do not reach for a product
that has fallen into water.
Unplug from the power socket
immediately.
Children should be supervised
to ensure that they do not play
with the appliance. Place the
appliance where children or
pets is not reachable.
Before each use, check the
breast pump, including the
power adapter for signs of
damage. Never operate the
breast pump if it has a damaged
plug, not working properly, has
been dropped or damaged, or
has been submerged in water.
5
English
corresponds to the local power
voltage.
Wash, rinse, and sterilise the
appropriate pump parts before
each use.
Do not use antibacterial,
abrasive cleaners, or detergents
when cleaning breast pump
parts.
Never put the breast pump
motor in water or steriliser,
as you can cause permanent
damage to the pump.
If the vacuum generated is
uncomfortable or cause pain,
switch o the breast pump,
break the seal between the
breast and the pump funnel
with your nger, and then
remove the pump from your
breast. You can also pull o the
silicone tube from the motor or
the cap to release the vacuum.
Do not continue pumping for
more than ve minutes at a time
if no result is achieved.
Never use any accessories or
parts from other manufacturers
or that Philips Avent does not
specically recommend. If
you use such accessories or
parts, your guarantee becomes
invalid.
Do not use the breast pump if
the silicone diaphragm appears
to be damaged or broken.
Replace the silicone diaphragm.
See chapter “Guarantee and
service” for information on how
to obtain replacement parts.
been given supervision or
instruction concerning use of
the appliance in a safe way and
if they understand the hazards
involved.
This appliance shall not be used
by children.
If expressing becomes
painful, stop and consult
your breastfeeding advisor or
healthcare professional.
Do not use the breast pump
in the presence of ammable
anaesthetic mixtures with air,
with oxygen, or with nitrous
oxide.
Although the breast pump
is compliant with applicable
EMC directives, it may still
be susceptible to excessive
emissions and/or may interfere
with more sensitive equipment.
Make sure not put any products
on the pump motor, like pillow,
blanket etc. Please make
sure pump motor work in well
ventilation and heat dissipation
condition.
Caution
The product should not be left
unattended when plugged into
a power socket.
Never drop or insert any foreign
object into any opening or the
silicone tube.
Do not shorten the silicone
tube.
Before you connect the breast
pump to the power, make sure
that the voltage of the product
6
English
2 Introduction
Congratulations on your purchase
and welcome to Philips Avent!
To fully benet from the support
that Philips Avent oers, register
your product at www.philips.com/
welcome.
The philips Avent breast pump
provides comfort, convenience
for eective expression. Rhythmic
Wave mimics the fast/shallow &
slow/deep way a baby suckles for
faster let down and continuous milk
ow with closer to natural sucking
pacing. It also has a soft massage
cushion, Alternating suction
especially for twin and an intuitive
design to make whole expression
more comfortable and convenient.
Doctors recommend that breast
milk is the best nutrition for babies
during the rst year, combined with
solid food after the rst six months,
Your milk is specially adapted to
your baby’s needs and contains
antibodies which help protect your
baby against infection and allergies.
Your twin electric breast pump will
help you breast-feed longer. You
can express and store your milk so
that - whether you are out for a few
hours, taking a well deserved rest,
or back at work - your baby can still
enjoy the benets of your breast
milk, even if you cannot be there to
give it yourself. As the pump is easy
to assemble, silent and discreet,
you can take it with you anywhere,
allowing you to express milk at your
own convenience and maintain
your milk supply.
Never use feeding teats as
dummies, paciers, or soothers.
Make sure that the teething
baby does not bite the teat
too long. The continuous and
prolonged bite will damage
the teat. For hygiene reasons,
replace teats after three
months of use. Use only
Philips Avent teats and bottles
together.
Batteries
This appliance can use both 1.5V
AA non-chargeable batteries and
rechargeable batteries.
For instructions on how to replace
the batteries see chapter ‘Preparing
for use’.
Dierent types of batteries or
new and used batteries are not
to be mixed.
Batteries are to be inserted
with the correct polarity.
Exhausted batteries are to be
removed from the appliance
and safely disposed of.
If the appliance is to be stored
unused for a long period, the
batteries should be removed.
The supply terminals are not to
be short-circuited.
Electromagnetic Fields
(EMF)
This Philips appliance complies
with all applicable standards and
regulations regarding exposure to
electromagnetic elds.
7
English
Overview
b a
r
e df
h
i
g
qp
c
j
l
k
m
n o
a Silicone tube j Teat (x2) (0m+)
b Cap (x2) k Sealing disc (x2)
c Silicone diaphragm (x3) (one for
back up)
l Breast pad
d Pump body (x2) m Bottle (x2) (125ml)
e Massage Cushion (x2) n Travel cover (x2)
f Pump cover (x2) o Pump motor
g Valve (x3) (one for back up) p Sling
h Dormal cap (x2) q Travel bag
i Screw ring (x2) r Power adapter
8
English
Control panel
s
t
u
v
w
x
~
}
|
{
z
y
s Timer counting indicator z Level up button
t Stimulation indicator { Pause/play button
u Level 2 indicator | Level 4 indicator
v Level 1 indicator } Level 3 indicator
w Mode selection button (selecting
the stimulation and expression
mode)
~ Expression indicator
x Level down button Battery indicator
y Power button
Note
The battery indicator ashes only when in low battery. We recomend you
to change the battery as soon as possible.
9
English
Caution
Take care when cleaning
the valve and the silicone
diaphragm. If it gets damaged,
your breast pump will not
function properly.
To clean the valve, rub it gently
between your ngers in warm
soapy water. Do not insert
objects as this may cause
damage.
3 Cleaning and
sterilising
Before you use your breast pump
for the rst time and for every time,
you must disassemble, wash, and
sterilise all the breast pump parts
that come into contact with your
breast milk. (see
c
,
d
,
e
,
f
,
g
,
m
,
n
in Overview chapter)
Before you use the bottle and its
parts for the rst time and for every
time,you must also disassemble,
wash and sterilise. (see
h
,
i
,
j
,
k
in Overview chapter)
Caution
Never wash or sterilise the pump
motor, the silicone tube, the cap,
and the power adapter. These
components do not come into
contact with your breast milk.
You can wipe those parts clean
with a soft cloth.
You can also use the dishwasher
(top rack only) or hand wash in
warm, soapy water, and then rinse
thoroughly. We recommend you
to sterilise all the parts contacting
with breast milk in our Philips Avent
steam steriliser, or by boiling for 5
minutes.
10
English
2 Put the bottle onto the pump
body and turn it anticlockwise
to x it. Do not over-tighten
when assembling the bottle to
the pump body.
3 Insert the Massage Cushion
into the pump funnel and press
the rim to ensure a perfect seal.
4 Put the silicone diaphragm onto
the pump body and press the
rim to make sure a perfect seal.
Tip
You may nd it easier to
assemble while it is wet.
4 Assembling
To assemble the pump, follow the
steps below.
Note
Make sure that you clean and
sterilise the pump as instructed
in this user manual.
Make sure that you assemble
the pump correctly as instructed
in this user manual.
To avoid leakage, remove the
residue around the rim before
assembling. Put the bottle onto
the pump body, and do not
over-tighten.
Wash your hand thoroughly
before you take sterilised
components.
1 Insert the valve into the pump
body from underneath.
11
English
8 Connect the power adapter
to the pump motor, and then
insert the power plug to the
power socket.
Note
Only use the adapter provided
with this product. Do not use
other adapter.
Tip
For battery operation, open
the rear cover of the motor unit
in the direction indicated by
the marks. Insert four new 1.5V
AA alkaline batteries into the
battery housing.Reattach the
rear cover to the motor unit.
We recommend you to use
rechargeable batteries for long
time use.
5 Firmly push the cap onto the
silicone diaphragm, so that it
sites securely on top of the
silicone diaphragm.
6 Repeat above steps 1-5 for
another pump body.
7 Connect the silicone tube to the
cap and the motor rmly.
12
English
5 Using your pump
Before using the pump
Wash your hands thoroughly, and
make sure your breasts are clean.
Gently squeeze a little milk from
each nipple to make sure that milk
ducts are not blocked.
Make sure you follow the steps
in “Cleaning and sterilising” and
“Assembling” chapters to clean,
sterilise, and assemble the breast
pump.
Relax in a comfortable chair,
leaning slightly forward (use
cushions to support your back).
Make sure that you have a glass
of water nearby.
To begin pumping
1 Press the assembled pump
bodies against your breasts.
Make sure that your nipples are
centered, so that the massage
cushion creates an airtight seal.
Make sure that no air escapes;
otherwise there is no suction.
Note
If you have inserted batteries in
the battery housing of the pump
motor and plug in the adapter,
the breast pump will run from
the main power supply. The
batteries cannot be charged in
the unit.
13
English
3 You can choose your desired
stimulation level to stimulate
milk by pressing the level up
( ) and level down ( )
buttons. You can press the
level up button to deeper
the suction. Press the level
down button to lower the
suction.There are altogether 4
stimulation levels.
4 Once your milk starts owing,
you can press the mode
selection button ( ) to switch
to the expression mode.
2 Press the power button ( ) to
switch on your pump.
» The display panel lights up
for 1 second. The breast
pump automatically starts up
in stimulation level 1 mode
in the rst time usage, and
the stimulation indicator
lights up. The appliance
has the memory function
to remember the levels for
your both stimulation and
expression in your latest
usage.
» You begin to feel the suction
on your breast.
Note
The timer starts when the
appliance is power on. The timer
indicator displays 01 after the
appliance has been power on
for 1 minute. The unit is minute.
The timer will show total breast
pumping time, pause time does
not count in.
If the timer displays over 99
minutes (when it comes to 100
minutes), the machine will shut
down automatically.
14
English
6 During expression, you can
switch between the stimulation
mode and expression mode
by pressing the mode
selection button ( ) for better
expression.
Note
You do not need to use all
stimulation/expression levels,
only use the levels that are
comfortable for you.
Place the pump motor on a
stable and at surface, or hang
up steadily with the included
sling, to avoid any accidental
drops when in use. If not, this
may pull the pump body o
from the breast and cause injury.
7 The twin electric breast pump
enables you to express milk
from both breasts at the same
time. However, you can also
use the appliance to express
from one breast. To express
from one breast, you need to
disconnect one silicone tube
from the cap, and insert it into
the connecting hole, or you can
take the pump from one breast.
5 After switching to the
expression mode, you can
choose your desired expression
level by pressing the level up
( ) and level down ( )
buttons. You can press the
level up button to deeper
the suction. Press the level
down button to lower the
suction.There are altogether 4
expression levels.
» The expression indicator
lights up instead of the
stimulation indicator.
Note
Do not worry if your milk does
not ow immediately. Relax and
continue pumping. The rst few
times you use the breast pump,
you may need to use a higher
expression mode to get your
milk owing.
Stimulation and expression
levels match to the number of
the owers lighting up. That is,
1 ower lighting up means level 1,
and 2 owers lighting up means
level 2.
When needed, you can also
use stimulation mode to do
expression.
15
English
Tip
After switching o the breast
pump, break the seal between
the breast and the pump funnel
with your nger, and then
remove the pump from your
breast.
9 Disconnect the the power plug
to the power socket, and then
disconnect the power adapter
from the pump motor.
Tip
In order to protect the appliance,
please always shut down the
appliance by pressing the power
button instead of plugging o.
10 Unscrew the bottles from the
pump bodies ready for feeding/
storage. Clean the other used
parts of the breast pump
according to the instructions
in chapter ‘Cleaning and
sterilising’.
Other operations are just in the
same way.
Note
If you regularly express more
than 125ml per session on each
breast, you can use a 260ml/9
oz Philips Avent bottle to
prevent overlling and spillage.
If there is no operation on
this appliance (such as pause,
change stimulation level
and expression level) for 30
minutes (including in pause),
the appliance will shut down
automatically.
8 When you have nished
expressing, press the power
button ( ) to switch o the
breast pump and carefully
remove the pump body from
your breast.
16
English
Caution
Do not continue pumping
for more than 5 minutes at a
time if you do not succeed
in expressing any milk. Try to
express at another time during
the day.
If the process becomes very
uncomfortable or painful, stop
using the pump and consult
your breastfeeding advisor.
Never tilt the breast pump
when the milk has reached the
maximum line on the bottle.
Replace with a new bottle
before re-pumping to avoid
spillage.
After expression, please take
o the bottle from pump body
immediately, then store the
bottle with sealing disc.
To pause pumping
This breast pump has a pause
function, and you can press the
pause button ( ) to pause pumping
if at any time the suction becomes
uncomfortable, there is a need to
change the bottle, reposition the
pump on the breast, or a short rest.
1 When the breast pump is in
a particular stimulation or
expression mode, press pause
button ( ) will pause the
pumping.
» The timer indicator, level
indicator, and stimulation/
expression indicator will ash
to remind you of the pausing
status.
Note
When the breast pump is
in pause, level down/level
up button and stimulation/
expression switch mode button
will lose their functions. Only
pausing button and power
button still work.
2 Press the pause button ( )
again to continue the pumping
with the stimulation or
expression mode selected
before pausing
Storing your breast milk
Caution
Never refreeze breast milk.
Do not mix fresh breast milk to
already frozen milk.
Always discard any left over milk
at the end of a feed.
17
English
Advanced anti-colic valve.
Innovative twin valve design
reduces colic and discomfort by
venting air into the bottle and not
baby's tummy.
Feeding your baby with
expressed breast milk
If you use Philips Avent bottle
to store breast milk, make sure
to remove the sealing disc and
assemble the Philips Avent teat
for feeding.
Place the frozen breast milk in the
refrigerator to defrost overnight.
In case of an emergency, you
can defrost the milk in a bowl of
hot water. Use up the defrosted
breast milk within 24 hours after
defrosting.
About heating up the breast milk:
Heat the bottle with in a bowl of
hot water, or using Philips Avent
bottle and baby food warmer to
safely heat up the milk.
Note
Only store breast milk collected
with a sterile pump.
1 After you have expressed your
milk, unscrew the pump bodies
from the Philips Avent bottles.
2 Store expressed milk in cleaned
and sterilised Philips Avent
bottles tted with sealing
discs. Put them in the fridge or
freezer immediately
You can store expressed
breast milk in the refrigerator
for up to 48 hours (not in the
door) or in the freezer for up
to 3 months.
Label the bottles with date
and time.
Use up the older milk rst.
Philips Avent Natural Bottle
provides:
Natural latch on. The wide breast
shaped teat makes it easy for
your baby to combine breast and
bottle feeding.
Unique comfort petals. Petals
inside the teat increase softness
and exibility without teat
collapse.
18
English
6 Hints to help you
succeed
The twin electronic breast pump is
easy to use. Take some practice,
and you will soon get used to
expressing milk.
Choose a time when you are not
rushed nor interrupted easily.
Having your baby or a photograph
of your baby nearby can help
encourage your milk to ow.
Before expressing milk, place a
warm towel onto your breast, and
lightly massage for a few minutes.
This encourages milk ow, and
ease the pain of your breast.
Warmth and relaxation can
encourage milk ow. Try
expressing after a warm bath or
shower.
Try expressing from one breast
while your baby is feeding from
the other, or continue expressing
just after a feed.
Repositioning the pump on the
breast from time to time can help
stimulate your milk ow.
Tip
Practice with your pump to nd
the best pumping techniques
for you. If the process becomes
painful, stop and consult your
breast-feeding advisor.
We recommand you to use the
breast pad to keep your bra
clean.
Caution
Remember! Always check milk
or food temperature before
feeding.
Never heat breast milk in
a microwave as this may
destroy valuable nutrients and
antibodies. In addition, the
uneven heating may cause hot
spots in the liquid which could
cause burns to the throat.
Never immerse a frozen bottle
in boiling water to avoid crack or
split.
Keeping your breast
pump sterile for travel
After sterilzing all parts, please
refer to steps in "Assembling"
to assemble the valve, Massage
Cushion, diaphragm and diaphragm
cap on the pump body, then put on
the pump cover and screw on the
travel cover, which can keep your
breast pump sterile for travel.
19
English
7 When to express
milk
If possible, wait until your milk
supply and breast-feeding schedule
are well established, unless told
otherwise by your doctor or breast-
feeding advisor.
The exceptions are:
If you are expressing milk for your
baby to be given in hospital.
If your breasts are engorged
(painful or swollen). You can
express a small amount of milk
before or between feeds to ease
the pain, and to help your baby
latch on more easily.
If you have sore or cracked nipples
and you may wish to express your
milk until they are healed.
If you are separated from your
baby and wish to continue
to breast-feed when you are
reunited. You should express your
milk regularly to stimulate your
milk supply.
Right times of the day to
express your milk
Early in the morning when you
breasts are full, just before or after
your baby’s rst feed.
After a feed, if your baby has not
emptied both breasts.
Between feeds or in a break if you
have returned to work.
1 Open the package and take out
the breast pad.
2 Remove the sticker and put
breast pad in the bra as picture
showed, sticked it on bra to
avoid movement.
20
English
10 Ordering
accessories
To purchase accessories for this
appliance, please visit our online
shop at www.shop.philips.com/
service. If the online shop is not
available in your country, go to
your Philips dealer or a Philips
service centre. If you have any
diculties obtaining accessories
for your appliance, please contact
the Philips Consumer Care Centre
in your country. You nd its contact
details in the worldwide guarantee
leaet.
8 Storage
Keep the breast pump out of
direct sunlight as prolonged
exposure may cause
discolouration.
Store the breast pump and its
accessories in a safe and dry
place.
9 Compatibility
The Philips Avent electric breast
pump is compatible with Philips
Avent bottles in our range. When
you use other Philips Avent bottles,
use the same type of teat that was
supplied with that bottle. For details
on how to assemble the teat and
general cleaning instructions, refer
to the user manual on our website,
www.philips.com/support.
1 / 1

Avent SCF303/01 ユーザーマニュアル

カテゴリー
搾乳器
タイプ
ユーザーマニュアル

他の言語で