Korenix JetCon 2301 V2 Series Quick Installation Manual

タイプ
Quick Installation Manual
JetCon 2301 V2 Series
Industrial Fast Ethernet to Fiber Media Converter
Quick Installation Guide
www.korenix.com
V1.0
Introduction
JetCon 2301 V2 is a single port Fast Ethernet to Fiber media converter, supporting 4 types of
forwarding modes – Store and Forward, Modied Cut-through, Pure Converter and Converter
with auto-change modes. The JetCon 2301 V2 adopts rugged aluminum case with IP31
grade enclosure and 1.5KV Hi-Pot isolation protection to operate in harsh environments with
severe electromagnetic interference and -25~70°C (JetCon 2301 V2) or -40~75°C (JetCon
2301 V2-w). It features Link Loss Forwarding to forward link status changes for alerting
remote or central management systems when a remote fault occurs. It also adopts one relay
output to alarm users if a port link fails or if the power fails. Alarms can be enabled/ disabled
by dip switch.
JetCon 2301 V2 has redundant power inputs with wide range DC10~60V through the 6-pin
removable terminal block. The ber port supports Single-mode or Multi-mode for providing
up to 30KM extended distance transmission.
Package Checklist
Unpack the box and you will nd
4JetCon 2301 V2 Industrial Media Converter
4Quick Installation Guide
Mounting the Unit
Din-Rail mount: Mount the din-rail clip on the rear of
JetCon 2301 V2 on the DIN rail.
For information about the DIN Rail installation, please refer to
user’s manual.The user manual can be downloaded from the
Korenix Web site as below: http://www.korenix.com/downloads.htm
Grounding JetCon 2301 V2
There is one grounding screw on the bottom side of
JetCon 2301 V2 . Connect the frame grounding of JetCon
2301 V2 to the grounding surface to ensure safety and
prevent noise for communication interference.
Chassis connects
to the Earth Ground
JetNet 2301 V2 Series
Industrial Fast Ethernet to Fiber Rail Media Converter
Quick Installation Guide
www.korenix.com
V1.0
Wiring the Power Inputs
Wiring the Relay Output
1. Insert the positive and negative wires into the V+ and V- contact on the terminal block
connector.
The relay output contacts are in the middle of the terminal block connector as shown in
gure-3. By inserting the wires and by setting the DIP switch of the respective alarm function
to “ON”, relay output alarm will detect port or power fault, and form a short circuit. The alarm
relay output is “Normal Open”. See, Figure-3. For detailed information, please refer to
chapter 2-5 of the User’s Manual.
2. Tighten the wire-clamp screws to prevent the power wires from being loosened.
Note: The recommended working voltage is DC 24V (Input range: DC10~ 60 V)
Accept 24AWG wire. JetCon 2301
V2 provides auto-polarity reverse
Note: The relay contact supports only 1A current,
DC 24V. It is not recommended to apply higher
voltage and current higher than this specication.
Maximum 1A Current / DC 24V
Alarm System
Extra Power
System
Connecting to Network
1. Connecting the Ethernet Port: Connect one end of an Ethernet cable into the UTP port of
JetCon 2301 V2, while the other end is connected to the attached networking device. UTP
port supports auto MDI/MDIX function. The LNK / ACT LED will turn on and start ashing to
indicate RJ-45 port links and the packets received and transmitted from RJ-45.
2. Connecting the Fiber Port: Connect the ber port of your JetCon 2301 V2 to another Fiber
Ethernet device, by following the gure below. Wrong connection or wrong ber cable type
will cause the ber port not working properly.
3. For different link distances, the JetCon 2301 V2 provides JetCon 2301 V2-m” for multi-
mode ber and “JetCon 2301 V2-s” for single-mode ber.
4. The table below illustrates ber transceiver specication.
xPwr(Min):Minimum Launch Power TxPwr(Max):Maximum Launch Power
RxPwr(Min):Maximum Receive Sensitivity RxPwr(Max):Minimum Receive Sensitivity
Link Budget=Minimum Launch Power –Maximum Receive Sensitivity
Note: To ensure your ber converter can transmit/receive data between the 2 nodes, the
attenuation of the optical ber cable should be smaller than the ber converter’s Link Budget.
This is a Class 1 Laser/LED product.
Don't stare into the Laser/LED Beam.
ATTENTION
RX
TX
RX
TX
RX A TX B
TX A RX B
Cable Wiring(SC to SC)
JetCon
2301 V2-m
JetCon
2301 V2-s
30km
2KM
Modul Fiber (um) ConnecterWavelength(um)
TXPwr
(Min)
TxPwr
(Max)
RxPwr
(Min)
RxPwr
(Max)
LinkBudg(dBm) Distance(km)
Single-Mode
8-10/125
SC 1310nm -15dBm-8dBm-34dBm 8dBm 19dBm
Multi-Mode
50~62.5/125
SC 1310nm -20dBm-14dBm-31dBm 0dBm11dBm
JetCon 2301 V2 DIP Switch Setting
Korenix Customer Service
Description
Enable Link Loss Forwarding function.
Disable Link Loss Forwarding function (Default)
Set TX port in 10 Mbps Half Duplex mode
Set TX port in Auto-Negotiation mode.(Default)
Enable power alarm
Disable power alarm (default)
Enable port alarm
Disable port alarm (default)
Disable Flow control
Enable Flow control (default)
Store and Forward forwarding mode (default mode)
Pure Converter forwarding mode
Modify Cut-Through forwarding mode
Converter mode with Auto-Change forwarding mode
Status
On
Off
On
Off
On
Off
On
Off
On
Off
DIP 3
Off
Off
On
On
DIP 4
Off
On
Off
On
Pin No. #
DIP 1
DIP 2
DIP 5
DIP 6
DIP 7
4
NO
123 5674
NO
123 567
Note: After adjusting the DIP-switch, please reboot the unit to activate the new settings.
KoreCARE is Korenix Technology’s global service center, where our professional staffs are
ready to answer your questions at any time.
Korenix global service center’s e-mail is [email protected]
概述
JetCon 2301 V2一款单口快速光电信号转换器,支4转发模式:存储转发,修改直,
纯转换和转换模式。JetCon 2301 V2备铝合金外壳,可适应-25~70°C劣工作环境,并提
-40~75°C温版本可选,而且可以抵御严重的电磁干扰影响。它满IP-31工业防护等级,
支持1.5KV Hi-Pot高压隔离保护。JetCon 2301 V2支持LLF(Link Loss Forwarding)远程故障检
测技术,一旦远程发生断线就会触发报警,此外,它还装备有一路继电器报警输出,可针对断
线断电事件进行报警。继电器报警可以通过DIP拨码开关启动或关闭。
JetCon 2301 V2DC10~60V宽范围冗余电源输入,配6-pin可拆卸接线槽。光口支持
模或多模两种机型满足不同传输距离的要求,最大传输距离可达30KM
设备安装
JetCon 2301 V2设备接地
导轨安装:将导轨夹固定在JetCon 2301 V2的背
面,然后卡上导轨。更多导轨安装信息,请参考用
户操作手册。
您可以登录Korenix网站到如下地址下载用户手册:
http://www.korenix.com/downloads.htm
JetCon 2301 V2的底部有一个接地螺母。
JetCon 2301 V2的接地螺母接地,
确保设备安全,防止电气干扰。
Chassis connects
to the Earth Ground
包装清单
打开包装,核对产品清单
4JetCon 2301 V2工业信号转换器
4快速安装向导
JetNet 2301 V2 Series
Industrial Fast Ethernet to Fiber Rail Media Converter
Quick Installation Guide
www.korenix.com
V1.0
电源连接
继电器报警连线
1. 将电源的正负极分别接入设备底部接线槽的V+ V- 接口。
如图3所示,继电器报警触点位于电源接线槽的中间位置。将报警线路接入固定,并将DIP
码开关置“ON”启动报警功能,继电器报警系统会自动检测端口及电源断连情况并组成一个
闭合回路。继电器报警线路默认是开路。欲了解更多信息,请参看用户手册chapter 2-5
2. 拧紧电源接线螺丝,防止电源线脱落。
备注: 建议工作电压为DC 24V (供电范围: DC10~ 60 V)
接线槽支持12~24AWG 电源线。
JetCon 2301 V2支持电源正负
极性反接保护
备注:继电器报警触点仅支持1A 电流,DC 24V
压。不建议在此线路中使用更高电压和电流。
Maximum 1A Current / DC 24V
Alarm System
Extra Power
System
网络连接
1. 网口连线: UTP双绞线的一端连接到JetCon 2301 V2的电口,另一端连接到相关网络设
备。UTP端口自适应MDI/MDIXLNK / ACT LED指示灯会亮起并闪烁,表RJ-45端口已连
接并正在收发数据。
2. 光口连线: 如图所示,将光纤的一端连接到JetCon 2301 V2,另一端连接到相关设备,进行
交叉互连。错误的连线会导致光口无法工作。
3. 针对不同传输距离,JetCon 2301 V2提供“JetCon 2301 V2-m”多模光口机型和
JetCon 2301 V2-s”单模光口机型。
4. 以下图表为光收发器规格
TxPwr(Min):最小发射功率 TxPwr(Max):最大发射功率
RxPwr(Min):最小接收灵敏度 RxPwr(Max):最大接收灵敏度
Link Budget=最小发射功率最大接收灵敏度
备注: 了确保光电转换器在2点间能够正常收发数据,光纤线材的衰减值一定要低于转换
器的Link Budget值。
此为Class 1 Laser/LED光口产品,
切勿直视激光束
传输距离(km)
波长(um)接头机型
RX
TX
RX
TX
RX A TX B
TX A RX B
Cable Wiring(SC to SC)
JetCon
2301 V2-m
JetCon
2301 V2-s
30km
2KM
Fiber (um)
TXPwr
(Min)
TxPwr
(Max)
RxPwr
(Min)
RxPwr
(Max)
LinkBudg(dBm)
Single-Mode
8-10/125
SC -15dBm-8dBm-34dBm 8dBm 19dBm
Multi-Mode
50~62.5/125
SC
1310nm
1310nm -20dBm-14dBm-31dBm 0dBm11dBm
备注
JetCon 2301 V2 DIP拨码开关设定
科洛理思售后服务
描述
启动LLF(Link Loss Forwarding)功能.
关闭LLF(Link Loss Forwarding)功能 (默认)
TX端口设置为10 Mbps半双工模式
TX端口设置为自动协商模式(默认)
启动电源报警
关闭电源报警 (默认)
启动端口报警
关闭端口报警 (默认)
关闭流控制
启动流控制(默认)
存储转发模式(默认模式)
纯转换模式
Modify Cut-Through转发模式
转换Auto-Change模式
状态
On
Off
On
Off
On
Off
On
Off
On
Off
DIP 3
Off
Off
On
On
DIP 4
Off
On
Off
On
Pin No. #
DIP 1
DIP 2
DIP 5
DIP 6
DIP 7
4
NO
123 5674
NO
123 567
备注: 更改DIP拨码开关设置以后,请重启设备让新设置生效。
KoreCARE 是科洛理思网络科技全球服务中心,我们专业的技术人员随时准备解答您的疑问。
台灣專利
發明第 I 321415
發明第 I 313547
新型第 M 339841
新型第 M 339840
Patent No. (Taiwan):
Granted Invention: I 321415
Granted Invention: I 313547
Utility Model: M339840
Utility Model: M339841
Tel:+886-2-89111000
Fax:+886-2-29123328
Business service:[email protected]
Customer service:[email protected]
CPQ000V2301000
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Korenix JetCon 2301 V2 Series Quick Installation Manual

タイプ
Quick Installation Manual

他の言語で