Korenix JetNet 3005G Quick Installation Manual

カテゴリー
ネットワークスイッチ
タイプ
Quick Installation Manual
Power Inputs
V-
Relay Output,
24V/1A
V+ V-V+
Wiring the Relay Output
e relay output alarm contacts are in the middle
of the terminal block connector as shown in the
gure. By inserting the wires and set the DIP
switch of Port Alarm to "ON", relay output alarm
Wiring the Power Inputs
JetNet 3005G supports DC 10~60V redundant
power input.
1. Insert the positive and negative wires into the V+
and V- contact on the terminal block connector.
2. Tighten the wire-clamp screws to prevent the DC wires from being loosened.
Notes: e recommended working voltage is DC24V (DC10~60V).
5 Years Warranty
Each of Korenix’s product line is designed, produced, and tested with high industrial
standard. Korenix warrants that the Product(s) shall be free from defects in materials and
workmanship for a period of ve (5) years from the date of delivery provided that the Product
was properly installed and used.
Support
is warranty is voided if defects, malfunctions or failures of the warranted Product are
caused by damage resulting from force measure (such as oods, re, etc.), other external forces
such as power disturbances, over spec power input, or incorrect cabling; or the warranted
Product is misused, abused, or operated, altered and repaired in an unauthorized or improper
way.
Attention! To avoid system damage caused by sparks, please DO NOT plug in power
connector when power is on.
e product is in compliance with Directive 2002/95/EC and 2011/65/EU of the European
Parliament and of the Council of 27 January 2003 on the restriction of the use of certain
hazardous substances in electrical and electronics equipment(RoHS Directives & RoHS 2.0)
Korenix Customer Service
KoreCARE is Korenix Technology's global service center, where our professional stas are
ready to solve your problems at any time Korenix global service center's e-mail is
For more information and documents download please visit our website:
http://www.korenix.com/downloads.htm
Grounding JetNet Switch
ere is one grounding screw on the bottom
side of JetNet 3005G. Connect the frame
grounding of switch to the grounding surface to
ensure safety and prevent noise to interfere
communication.
Connecting to Network
Connecting the Ethernet Ports: Connect one end of an Ethernet cable into the UTP port of
JetNet 3005G, while the other end is connected to the attached networking device. All UTP
ports support auto MDI/MDIX function. e LNK / ACT LED will turn Amber on for
1000Mbps Ethernet or Amber o for 10/100Mbps Ethernet.
will detect any port failures, and form a short circuit. e alarm relay output is
"Normal Open".
P6
P1 to P5
(Pin1 ~5)
Pin No. # Status Description
To enable port link down alarm at this portON
Off To disable port link down alarm at this port
To enable power failure alarmON
Off To disable power failure alarm
NO
1 2 5 643
Alarm Switch
DIP Switch Settings for Alarm Relay Output
DIP Switch Settings for Alarm Relay Output
Package Check List
JetNet 3005G Switch
Quick Installation Guide
JetNet 3005G Industrial 5-port Full Gigabit Ethernet Switch
Quick Installation Guide V1.1
JetNet 3005G Industrial 5-port Full Gigabit Ethernet Switch support 5 10/100/1000Baes-T
Ethernet port and adopts slim industrial design to save space for compact system requirement.
JetNet 3005G also provides one relay output to alarm port break events, which is enabled/
disabled by the dip switch. JetNet 3005G is recommended to be powered by DC24V
(10~60V) from the 6-pin terminal block.
Overview
A Beijer Electronics Group Company
Installation
Mount the unit
Din-Rail mount: Mount the din-rail clip screwed
on the rear of JetNet on the DIN rail
Package Check List
JetNet 3005G Switch
Quick Installation Guide
JetNet 3005G Industrial 5-port Full Gigabit Ethernet Switch
Quick Installation Guide V1.0
JetNet 3005G Industrial 5-port Full Gigabit Ethernet Switch supports 5 10/100/1000Baes-T
Ethernet port and adopts slim industrial design to save space for compact system requirement.
JetNet 3005G also provides one relay output to alarm port break events, which is enabled/
disabled by the dip switch. JetNet 3005G is recommended to be powered by DC24V
(10~60V) from the 6-pin terminal block.
Overview
A Beijer Electronics Group Company
Installation
Mount the unit
Din-Rail mount: Mount the din-rail clip screwed
on the rear of JetNet on the DIN rail
Package Check List
JetNet 3008/3008f Switch
Quick Installation Guide
A Beijer Electronics Group Company
JetNet 3008/3008f Series Industrial Ethernet Switch
Quick Installation Guide V1.5
JetNet 3008/3008f Industrial Ethernet Switch, supports 8 10/100Base TX (JetNet 3008) or
6 10/100TX plus two 100FX Fast Ethernet ber ports in either multi-mode type (JetNet
3008f-m) or single-mode type (JetNet 3008f-s). e JetNet3008/3008f adopts rugged metal
case design to operate in harsh environments (-40~75oC JetNet 3008-w/3008f-w); It also
provides IP-30 standard protection. It features one relay output to alarm users if a port link
fails or with the power fails. Alarms can be enabled/disabled by a 9-pin dip switch. JetNet
3008/3008f is recommended to be powered by DC 12V or 24V with 10~60V range from
the 6-pin removable terminal block.
Overview
Power Inputs
V- V-V+ V+
产品清单
JetNet 3005G全千兆工业级以太网交换机
快速安装向导
Patent No. (Taiwan):
Granted Invention: I 313547
Granted Invention: I 321415
Granted Invention: I 344766
Granted Invention: I 346480
Granted Invention: I 356616
Granted Invention: I 364684
Granted Invention: I 376118
Granted Invention: I 393317
Granted Invention: I 398066
Granted Invention: I 398125
Utility Model: M 339841
Utility Model: M 339840
Korenix
售后服务
KoreCARE 是科洛理思科技全球服务中心,我们专业的技术人员随时准备解答您的
疑问。科洛理思全球服务中心 EMAIL: [email protected]
详细说明及文件请至网站下载: http://www.korenix.com.cn/support_downloads.htm
业务服务: [email protected]
官网: www.korenix.com.cn
客户服务
5
年质保
所有科洛理思产品的设计、制造及测试都是采用较高的工业标准。科洛理思保证自
产品出货日起提供最高5年之免费保修服务,保修期间如因零件损坏或制程不良而
导致产品故障,我们将提供免费维修服务。
然而,自然外力(火、水、雷灾)所造成的产品故障,或其它外部因素如电源干扰、
不当电源输入、不当接线等造成的损坏,不列入产品保固范围;此外,产品被误用
、未经授权的修理及修改等行为将造成保固条款失效。
注意! 请勿于电源开启时插拔接线端子,以避免产生火花造成系统损坏。
此产品保证完全符合欧盟2003127日电气和电子设备危害物质限制委员会所提
出的限用指令2002/95/EC(ROHS禁令)2011/65/EU(RoHS 2.0)
Tel:+886-2-89111000
Fax:+886-2-29123328
Business service:[email protected]
Customer service:[email protected]
www.korenix.com
CPQ000N3005001
Korenix Technology Co., Ltd.
(A Beijer Electronics Group Company)
JetNet 3005G全千兆工业级以太网交换机,提供510/100/1000Base-TX端口並採用
纤薄的工业设计,节省空间以符合系统的要求。
JetNet 3005G还提供端口断线继电器报警输出功能,透过底部的DIP拨码开关,启动
或关闭报警系统。JetNet 3005G建议供电范围︰透过 6-pin terminal block 为设备供给
DC24V (10~60V)
导言
安装配件
导轨安装: 将
JetNet 3005G
后面的导轨夹卡上导轨
安装
地线连接
JetNet 3005G底部有一个地线连接螺丝。
JetNet地线螺丝接地,可以确保设备使用
安全,并可防干扰。设备未接地,因自然
因素造成损害,将不予以修复。
电源线连接
JetNet 3005G支持DC10~60V冗余电源输入。
1. 将电源线正负极插入产品底部接线端子的V+
V- 接脚。
2. 将线夹拧紧,防止DC电源线脱落。
备注: 建议供电范围DC24V (DC10~60V)
电源线连接
继电器输出触点在产品底部接线端子的中间,
如右图所示。使用该界面连接报警系统,并将
DIP拨码开关置"ON",继电器报警输出系统就
可以监视任意端口的断线情况,一旦发现断线
,自动形成一个闭合环路。正常情况下报警系
统是开路。
网络连接
连接以太口: 双绞线的一端连接JetNet 3005G UTP口,另一段连接网络设备。所有
UTP口自适应MDI/MDIX1000M连接时LNK / ACT指示灯显示黄色,10/100M
接时黄色指示灯熄灭。
DIP 拨码开关设置继电器报警
Relay Output,
24V/1A
P1 to P5
(Pin1 ~5)
Pin No. # 状态 描述
启动该端口断线报警ON
Off 关闭该端口断线报警
启动供电断线报警ON
Off 关闭供电断线报警
NO
1 2 5 643
Alarm Switch
P6
Package Check List
JetNet 3005G Switch
Quick Installation Guide
JetNet 3005G Industrial 5-port Full Gigabit Ethernet Switch
Quick Installation Guide V1.0
JetNet 3005G Industrial 5-port Full Gigabit Ethernet Switch supports 5 10/100/1000Baes-T
Ethernet port and adopts slim industrial design to save space for compact system requirement.
JetNet 3005G also provides one relay output to alarm port break events, which is enabled/
disabled by the dip switch. JetNet 3005G is recommended to be powered by DC24V
(10~60V) from the 6-pin terminal block.
Overview
A Beijer Electronics Group Company
Installation
Mount the unit
Din-Rail mount: Mount the din-rail clip screwed
on the rear of JetNet on the DIN rail
Package Check List
JetNet 3008/3008f Switch
Quick Installation Guide
A Beijer Electronics Group Company
JetNet 3008/3008f Series Industrial Ethernet Switch
Quick Installation Guide V1.5
JetNet 3008/3008f Industrial Ethernet Switch, supports 8 10/100Base TX (JetNet 3008) or
6 10/100TX plus two 100FX Fast Ethernet ber ports in either multi-mode type (JetNet
3008f-m) or single-mode type (JetNet 3008f-s). e JetNet3008/3008f adopts rugged metal
case design to operate in harsh environments (-40~75oC JetNet 3008-w/3008f-w); It also
provides IP-30 standard protection. It features one relay output to alarm users if a port link
fails or with the power fails. Alarms can be enabled/disabled by a 9-pin dip switch. JetNet
3008/3008f is recommended to be powered by DC 12V or 24V with 10~60V range from
the 6-pin removable terminal block.
Overview
  • Page 1 1
  • Page 2 2

Korenix JetNet 3005G Quick Installation Manual

カテゴリー
ネットワークスイッチ
タイプ
Quick Installation Manual

他の言語で