Pioneer CA500セットの最新アップデート後 取扱説明書

タイプ
取扱説明書

このマニュアルは次のような方にも適しています

EN
DE
FR
IT
ES
EN
DE
FR
NL
IT
ES
JP
Please read the "Important Information for the User" in the product box
for product warnings and other important safety information.
User's Manual
Pedaling Monitor Sensor
SGY-PM910ZW
SGY-PM910ZLW
SGY-PM910ZRW
ペダリングニターセをご使用にる前に、 必ずをおみくだい。
みになったあと に保管しくださ
ペダリングモニターセンサー
取扱説明書
2
EN
Introduction
Table of Contents
Introduction
Features ..................................................................................... 3
Compatibility .............................................................................. 6
Getting Started
Product Conguration ................................................................ 7
Installing and Removing the Batteries......................................12
Switching to the pedaling monitor mode ..................................15
Switch to dual power meter mode ...............................................19
Switch to single power meter mode ........................................ 23
Pairing /Calibration
Pairing with the Cyclocomputer ............................................... 24
Calibrating the sensors (zero point calibration) ....................... 26
Specifications and support
Troubleshooting ....................................................................... 28
Specications ...........................................................................31
Care, Maintenance, and Storage ............................................ 32
This product is ANT+™ certied.
Visit http://www.thisisant.com/directory/
for a list of compatible products and apps.
3
EN
Introduction
Features
This product is a sensor system that analyzes the pedaling of a bicycle in real
time. It calculates the direction and intensity of the force acting on the pedals
and calculates pedaling efciency.
Description of components
Strain gauge unit :
Detects the strain on the crank and calculates the direction and intensity of the
force on the crank.
Magnet:
Used to detect the angle of rotation.
Transmitters:
Send information from the strain gauge unit and the magnet to the
Cyclocomputer.
Product mode
When using SGX-CA500, the rmware version is required to be 20150501.02.43 or
higher.
Pedaling monitor mode:
When paired with Cyclocomputer SGX-CA500, the pedaling efciency and
cadence and other such properties can be measured. You can make maximum
use of the functions of this product.
Dual power meter mode:
Left and right sensors are required. The actual power values of the left and right
sensors can be totaled and displayed and the cadence can be measured. Can be
used with SGX-CA500 or with a Cyclocomputer that supports ANT+ from another
manufacturer.
Single power meter mode:
The power value of the left or right sensors can be doubled and displayed quickly
and the cadence can be measured. Can be used with SGX-CA500 or with a
Cyclocomputer that supports ANT+ from another manufacturer.
4
EN
Introduction
Switching modes
When using SGX-CA500, the rmware version is required to be 20150501.02.43 or
higher.
Pedaling monitor mode (Page 15)
Can be switched with SGX-CA500. Cannot be switched with cyclocomputers from
other manufacturers. When the mode is switched to pedaling mode, the LEDs on the
sensors light green for 10 seconds.
Current mode
Method 1
(Right sensor push switch)
M
ethod 2
(
SGX-CA500)
LED
lighting
method
Dual power meter Cannot be switched
The LEDs light
green for 10
seconds
Single power meter Cannot be switched
Dual power meter mode (Page 19)
The mode can be switched on SGX-CA500 or by operating the right sensor push
switch. When using with another manufacturer’s Cyclocomputer, switch using
method 1. When the mode is switched to powermeter mode, the LEDs light orange
for 10 seconds.
Current mode
Method 1
(Right sensor push switch)
M
ethod 2
(
SGX-CA500)
LED
lighting
method
Pedaling monitor Cannot be switched
The LEDs light
orange for 10
seconds
Single power meter
5
EN
Introduction
Single power meter mode (Page 23)
SGX-CA500 is required to switch from pedaling monitor mode. Cannot be switched
with cyclocomputers from other manufacturers. To switch from the dual power meter
mode, use SGX-CA500 or press the push switch of the right sensor. When the mode
is switched, the LEDs on the sensors blink orange for 10 seconds.
Current mode
Method 1
(Right sensor push switch)
M
ethod 2
(
SGX-CA500)
LED
lighting
method
Pedaling monitor Cannot be switched
The LEDs blink
orange for 10
seconds
Dual power meter
Manuals
The product’s manuals consist of this User’s Manual, Support Pages, and
Important Information for the User.
User’s Manual (this document)
Explains how to switch the modes of the product, and how to pair the product
with the Cyclocomputer and calibrate the sensors.
Support pages (WEB site)
http://pioneer-cyclesports.com/us-en/support/products/
Explains details about handling methods. How to detach the product (for
dealers) is also descr bed in the references.
Important Information for the User
Important Information for the User provides detailed information related to
safety.
6
EN
Introduction
Compatibility
Crank set
This product supports the following crank sets.
Crank set (left/right)
Remarks
SHIMANO FC-R8000
Supports 165 / 170 / 172.5 / 175 mm crank length and 50-34T / 52-36T /
53-39T crank sets.
When replacing the chain ring, be careful not to disconnect the junction cable of the right
pedaling monitor sensor. See the video on how to remove the chain ring rst on
http://pioneer-cyclesports.com/us-en/support/products/ to conrm the procedure.
Special skills and tools are needed for the installation and calibration of the
product. To install and calibrate, always ask the shop from where you bought the
product to do it.
Since the product is attached to the crank set with an adhesive, it cannot be
removed without destroying the sensor.
SHIMANO FC-R9100
Supports 165 / 167.5 / 170 / 172.5 / 175 / 177 5 / 180 mm crank leng h,
and 50-34T / 52-36T / 53-39T / 54-42T / 55-42T crank sets.
7
EN
Getting Started
SGY-PM910ZW
This product contains the following parts.
Pedaling monitor sensor (left side)
Pedaling monitor sensor (right side)
Product Conguration
Left transmitter
Strain gauge unit
LED
Device Number
Pedaling monitor sensor part (left side)
Right transmitter
Junction cable
Strain gauge unit
Junction box
Device Number
(Described on the back)
Pedaling monitor sensor part (right side)
8
EN
Getting Started
Product Conguration
Magnet
Patch type x 2
Others
For FC-R9100
For FC-R8000
Strain gauge unit cover x 1
for each type
Chain ring Adapter
For FC-R9100
Warranty Card
Batteries (CR2032) x 2 (preinstalled in the sensors)
Right transmitter cover (metallic red)
Hex screws (M2.6 x 8 mm) x 3 (for the right transmitter x 3)
Hex screws (M2.6 x 5 mm) x 3 (spare for the right transmitter cover x 3)
Patch type magnet base × 2
Tape for installing the chain ring adapter
, FC-R8000
9
EN
Getting Started
Product Conguration
SGY-PM910ZLW
This product contains the following parts.
Pedaling monitor sensor (left side)
Magnet
Patch type
Others
Warranty Card
Batteries (CR2032) (preinstalled in the sensor)
Patch type magnet base
Left transmitter
Strain gauge unit
LED
Device Number
Pedaling monitor sensor part (left side)
10
EN
Getting Started
Product Conguration
SGY-PM910ZRW
This product contains the following parts.
Pedaling monitor sensor (right side)
For FC-R9100
For FC-R8000
Strain gauge unit cover x 1
for each type
Right transmitter
Junction cable
Strain gauge unit
Junction box
Device Number
(Described on the back)
Pedaling monitor sensor part (right side)
11
EN
Getting Started
Product Conguration
Magnet
Patch type
Others
Warranty Card
Batteries (CR2032) (preinstalled in the sensor)
Right transmitter cover (metallic red)
Hex screws (M2.6 x 8 mm) x 3 (for the right transmitter x 3)
Hex screws (M2.6 x 5 mm) x 3 (spare for the right transmitter cover x 3)
Patch type magnet base
Tape for installing the chain ring adapter
Chain ring Adapter
For FC-R9100
, FC-R8000
12
EN
Getting Started
Installing and Removing the Batteries
The batteries are pre-installed to this product. If the batteries are almost
empty (see Page 28 for how to conrm), replace the batteries with new ones
by the following procedure.
Replace the batteries of both the left and right sensors at the same time.
1. Remove the cover.
Be careful not to drop or lose the
battery when removing the cover.
Right transmitter (screws: 3 x)
Use a hex wrench (2 mm) to loosen
the screw and remove the cover.
Be careful not to lose the removed
screw.
Do not lose the water-proof packing.
Left transmitter
Turn the cover to the left so the
triangular arrow points to [OPEN]
and remove it.
13
EN
Getting Started
Installing and Removing the Batteries
2. Remove the old battery.
Right transmitter
Left transmitter
3. Install the new battery
(CR2032).
Right transmitter
Left transmitter
After installing the battery, place
the cover with the triangular arrow
pointing to [OPEN], and turn it with
coin to [CLOSE].
Be careful not to drop or lose the
battery when installing it.
Do not lose the water-proof packing.
Do not use batteries other than
CR2032. It can cause malfunction.
Install the cover rmly to ensure
water resistant performance.
Use a dry cotton swab to wipe the
battery terminal in the transmitter
taking care not to deform the
terminal. Clean the terminal regularly
to ensure that the transmitter
operates steadily.
14
EN
Getting Started
Installing and Removing the Batteries
4. Check the LED display.
The transmitter starts when the
batteries are installed. The LEDs of the
transmitters light as follows depending
on the actual sensor mode.
When it is in pedaling monitor
mode:
The LEDs light green for 10
seconds
When it is in dual power meter
mode:
The LEDs light orange for 10
seconds
When it is in single power meter
mode:
The LEDs blink orange for 10
seconds
If the LEDs do not light for more
than 5 seconds after installing the
batteries, remove the batteries
once, and after more than 1 minute,
install them again. If the LEDs still
do not light, the battery may be
almost empty. Replace the battery
with a new one. Dispose of useless
batteries as instructed by the local
government.
5. Install the right transmitter
cover and tighten the screws
to x it in place.
While tightening the screws, do not
use excessive force or over-tighten
them. The plastic cover can crack if
you do so. Use a tool that can measure
the torque to tighten the screws.
Tightening torque: 30 cN·m
Install the transmitter cover and
screw the screws in rmly to ensure
water resistant performance.
Push switch
LED
Water-proof
packing
15
EN
Getting Started
Switching to the pedaling monitor mode
1. Press the menu button on
the CycloMeter screen of
SGX-CA500.
2. Tap [Option] - [Pedaling
settings] - [Mode Switch] in
this order.
The mode switching screen opens.
If the device number is already
displayed, conrm that it is the same
as the device number of the sensor
you want to use. If it is the same, the
input operation is not required.
If the device number is different from
the sensor you want to use, enter the
new number.
Remove the check from the sensors
whose mode is not to be switched.
3. Tap on the device number
display part.
The sensor device number input
screen opens.
Cyclocomputer SGX-CA500 is required to switch to the pedaling monitor mode. The
mode cannot be switched with cyclocomputers from other manufacturers.
The rmware version of SGX-CA500 needs to be 20150501.02.43 or higher. If it is of
a different version, update the rmware. Refer to the User's Guide (For WEB) of SGX-
CA500 regarding how to update or any other operation method.
http://pioneer-cyclesports.com/us-en/support/products/
16
EN
Getting Started
Switching to the pedaling monitor mode
4. Enter the device number and
tap [ ].
The device numbers are printed on
the right junction box and on the side
of the left sensor. (Page 7)
5. Rotate the bicycle’s crank
set more than three rotations
to start the left and right
transmitters.
Pair with the Cyclocomputer within
5 minutes after the transmitters are
activated.
6. Tap [Pedaling Monitor].
The search for the sensor starts. A
[Please wait.] message appears.
It may take more than 1 minute to to
pair with the sensor.
The mode switching completion
screen opens. Tap OK if you want to
add in the sensor list.
17
EN
Getting Started
Switching to the pedaling monitor mode
[Success]
Mode is switched.
[Timeout]
Sensor is not found.
[Cancel]
Cancel is pressed.
[Low Battery]
The battery is almost empty.
Timeout: Communication status is
likely to be poor. Sensor information
cannot be received properly. Make
sure that the sensor you are pairing
is activated, then bring the SGX-
CA500 closer to the sensor and
perform the pairing operation again.
Pairing with the sensor may not be
possible due to interference in the
same frequency band. If “Timeout
is displayed even by operating
after moving SGX-CA500 closer to
the sensor and pairing with it, try
again someplace where there is no
interference from microwaves, radio
waves, or wireless equipment.
Low Battery: The battery is almost
empty. Remove the battery and
replace with a new one. For how
to install/remove batteries, refer to
Page 12.
If you do not add the sensor in the
sensor list, the SGX-CA500 will not
pair with the sensor.
You can add the sensor in the sensor
list later, using the [Sensors] menu.
When the mode is switched, the
LEDs of the sensors light green for 10
seconds.
Add in the sensor list of SGX-
CA500
When it is added in the sensor list,
it pairs with SGX-CA500. Hereafter,
whenever the sensor is started, it will
automatically pair with SGX-CA500.
To conrm the sensor list, press the
menu button on the left of the product
on the main screen of the CycloMeter
and tap [Sensors]. The display on the
mode switching completion screen is
as follows depending on the status.
18
EN
Getting Started
Switching to the pedaling monitor mode
Copy pedal
Copy pedal is enabled only in pedaling
monitor mode.
If only the sensor on one side is
operating, you can copy the data on
the other side also to display it for
both sides on the Cyclocomputer and
record it in the log. You can select
copy pedal of the current bike and set
the balance.
1. Press the menu button on
the CycloMeter screen.
2. Tap [Option] then [Pedaling
settings] and then [Pedaling
Copy].
3. Tap [Pedaling Copy], and
select the copy method.
4. To change the balance, tap
[L:R Balance].
5. Tap [+], [-] and change the
numerical value and tap [OK].
If you set left and right incorrectly,
note that the correct power will not
be displayed.
19
EN
Getting Started
Switch to dual power meter mode
Both the left and right sensors are required in this mode. Cyclocomputer SGX-CA500 is
required when the sensor changes to the pedaling monitor mode. It cannot be switched
by using cyclocomputers from other manufacturers.
The rmware version of SGX-CA500 needs to be 20150501.02.43 or higher. If it is of
a different version, update the rmware. Refer to the User's Guide (For WEB) of SGX-
CA500 regarding how to update.
http://pioneer-cyclesports.com/us-en/support/products/
The mode can be switched in two ways.
[Method 1] Switch by pushing the
push switch in the right transmitter
When using a Cyclocomputer from
another manufacturer, switch with
this method.
1. Loosen the screws on the
right transmitter cover and
remove the cover.
Refer to Page 12 to remove the right
transmitter cover.
2. Replacing the batteries of the
left and right transmitters.
Refer to Page 12 regarding how to
install/remove batteries.
The operation is enabled for 5
minutes after the batteries are
installed. Switch within 5 minutes.
If more than 5 minutes elapse, re-
install the batteries of the left and
right sensors.
3. Conrmation of the actual
sensor mode.
When the batteries are installed, the
LEDs on the left and right transmitters
light as follows depending on the
actual sensor mode.
When it is in pedaling monitor
mode:
The LEDs light green for 10
seconds
When it is in dual power meter
mode:
The LEDs light orange for 10
seconds
When it is in single power meter
mode:
The LEDs blink orange for 10
seconds
20
EN
Getting Started
Switch to dual power meter mode
4. Switch the sensor mode.
Before switching the mode, conrm
that there is no other pedaling
monitor near by. If this is not done at
a sufcient distance away from other
sensors, the other sensors are likely
to malfunction.
Push switch
LED
Water-proof
packing
Push for more than
3 seconds
The LEDs blink green
Push for more than
3 seconds
Move away
The LEDs blink orange
rapidly
Conrm that the LEDs
on left and right
transmitters are blinking
The LEDs blink red
The LEDs light orange
Finished
Failure
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234

Pioneer CA500セットの最新アップデート後 取扱説明書

タイプ
取扱説明書
このマニュアルは次のような方にも適しています