Flexible Current Probe Meter
軟性電流探針表
软性电流探针表
フレキシブル電流プローブ
Гибкая токовая петля
Read First
!
!Safety Information
To ensure safe operation and service of the meter,
follow these instructions. Failure to observe warnings
can result in severe INJURY or DEATH.
WARNING identifies hazardous conditions and
actions that could cause bodily harm or death.
- If the equipment is used in a manner not specified
by the manufacturer, the protection provided by the
equipment may be impaired.
- Always use proper terminals and range for
measurements.
- Always use proper terminals, switch position, and
range for measurements.
- To reduce the risk of fire or electric shock, do not
use this product around explosive gas or in damp
locations.
- Verify the Meter operation by measuring a known
voltage. If in doubt, have the Meter serviced.
- Do not apply more than the rated voltage, as
marked on Meter, between terminals or between
any terminal and earth ground.
- To avoid false readings that can lead to electric
shock and injury, replace battery as soon as low
battery indicator appears.
- Avoid working alone so that assistance can be
rendered.
- Do not use the Meter if the Meter is not operating
properly or if it is wet.
- Individual protective device must be used if
hazardous live parts in the installation where the
measurement is to be carried out could be
accessible.
- When using test leads or probes, keep your fingers
behind the finger guards.
Warning
!
EN
sFLEX 18A
1
- Use caution with voltages above 30 Vac rms, 42 Vac
peak, or 60 Vdc. These voltages pose a shock hazard.
- Remove test lead from Meter before opening the
battery door or Meter case.
- DO NOT USE the test leads when the internal white
insulation layer is exposed.
- DO NOT USE the test leads above maximum ratings
of CAT. environment, voltage and current, that are
indicated on the probe and the probe tip guard cap.
- DO NOT USE the test leads without the probe tip
guard cap in CAT III and CAT IV environments.
- Probe assemblies to be used for MAINS measure
ments shall be RATED as appropriate for MEAS
UREMENT CATEGORY III or IV according to IEC
61010-031 and shall have a voltage
RATING of at least the voltage of the circuit to be
measured.
- Disconnect circuit power and discharge all high
voltage capacitors before testing resistance, continuity,
diodes, or capacitance.
- Do not use a flexible current sensor if the inner copper
wire of the insulation of the flexible cord is visible.
- De-energize the installation under test or wear suitable
protective clothing during fitting and removal of the
Flexible Current Probe.
- Do not apply around or remove from UNINSULATED
HAZARDOUS LIVE conductors, which may render
electric shock, electric burn, or arc flash.
!
Caution
CAUTION identifies conditions and actions that could
damage the Meter, the equipment under test, or cause
permanent loss of data.
- Remove the batteries if the Meter is not used for an
extended period of time, or if stored in temperatures
above 50 °C. If the batteries are not removed, battery
leakage can damage the Meter.
- Do not expose Meter to extremes in temperature of
high humidity.
EN
sFLEX 18A
2
Symbols on Meter and in this Manual
EN
sFLEX 18A
!
See instruction manual
WARNING. HAZARDOUS VOLTAGE.
Risk of electric shock.
Caution
Do not apply or remove clamp from
HAZARDOUS LIVE conductors
AC (Alternating Current or Voltage)
DC (Direct Current or Voltage)
Both AC and DC
CAT IV
CAT III
IEC Overvoltage Category
CAT III equipment is designed to protect
against transients in equipment in fixed
equipment installations, such as
distribution panels, feeders and short
branch circuits, and lighting systems in
large buildings.
CAT IV equipment is designed to protect
against transients from the primary
supply level, such as an electricity Meter
or an overhead or underground utility
service.
Earth ground
Equipment protected by double or
reinforced insulation.
Battery capacity
Wireless transmission
Conforms to European Union directives.
Do not discard this product or throw
away.
3
Meter Description
1. Clamp lock mechanism
2. LCD display
3. Function buttons
4. V-Ω input terminal
5. COM input terminal
EN
sFLEX 18A
4
LCD Description
Power On / Off
The Meter displays battery capacity when powering
up.Please replace the battery when 0% is shown.
1. Meter status symbols
2. Battery capacity symbols
3. Large scale LCD readout
4. Function unit symbols
5. Hold symbol
6. Sub LCD readout
EN
sFLEX 18A
5
Disable Auto Power Off
Press > 2Sec
Auto Power Off
If no any operation in Meter, it will auto power off after
20 minutes.
To disable APO, push and hold the Bluetooth button,
then turn the Meter power on.
EN
sFLEX 18A
6
AC Current Measurement
!
Warning
The barrier on the JAW is indicating the limit of safe
access of the hand held part, do not hold over the
barrier when in normal use.
!Barrier for
Hand Guard
Unlock / Lock Clamp Jaw
Turn the clamp lock counter-clockwise to release the
flexible clamp. Fully enclose only one conductor of the
device under test with the flexible clamp probe.
Re-secure the clamp lockafter clamping around a
single conductor.
EN
sFLEX 18A
7
Position Error
When measuring current, move a single cable in the
center of the flexible clamp jaw. It can make less the
position error.
Voltage & Resistance Measurement
• When connecting the test leads to the DUT (Device
Under Test) connect the common test leads before
connecting the live test leads; When removing the test
leads, remove the live test leads before removing the
common test leads.
• Do not use the LoZ mode to measure voltages in
circuits that could be damaged by this mode’s low
impedance (approx. 4kΩ).
EN
sFLEX 18A
8
Data Hold
EN
sFLEX 18A
9
The Meter uses low-power (BLE) v4.0 wireless
technology to transfer the real-time data. To use the
RF communication link on Android or iOS devices,
install App from the below QR code.
Backlight
The RF communication range: Open air up to 10 m
APPA Connect
on Apple App Store
APPA Connect
on Google Play
To turn On / Off the backlight, press the backlight
button once.
Worklight
To turn On / Off the worklight, push and hold the
backlight button
>1sec.
EN
sFLEX 18A
10
Battery Replacement
Maintenance
Verify the Meter’s operation by measuring a known
voltage. If in doubt, have the Meter serviced. Do not
attempt to repair this Meter. It contains no user
serviceable parts. Repair or servicing should only be
performed by qualified personnel. To maintain the best
accuracy, calibrate Meter once per year.
Cleaning
Periodically wipe the case with a dry cloth and
detergent do not use abrasives or solvents.
Storage
Remove the batteries if the Meter is not used for an
extended period of time, or if stored in temperatures
above 50 °C. If the batteries are not removed, battery
leakage can damage the Meter.
EN
sFLEX 18A
11
General Specifications
LCD display digits :
9,999 digit large scale LCD readout
Overload display : OL or -OL
Battery Type :
2 Batteries, IEC LR6, NEDA 15A, Alkaline (AA)
Battery Life : Alkaline 60 hours
Low Battery Voltage : 2.5V ± 0.2V
Auto Power Off :
The Meter automatically turns off if the buttons are
not pressed for 20 minutes.
Conductor Size : 18 inch
Environmental Conditions
Temperature Coefficient :
0.1 x (specified accuracy) / °C (<18 °C or >28 °C)
Operating Temperature :
-10°C to 30 °C (≤ 80% R.H.)
30°C to 40 °C (≤ 75% R.H.)
40°C to 50 °C (≤ 45% R.H.)
Storage Temperature :
-20°C to 60°C (≤ 80% R.H., no batteries)
Max. Operating Altitude : 2000m (6562 ft.)
Drop Protection :
4 feet drop to hardwood on concrete floor
Vibration :
Random Vibration per MIL-PRF-28800F Class 2
Calibration cycle : One year
Indoor Use
Safety Standards :
• IEC / EN 61010-1
• EN 61010-2-032
• EN 61010-2-033
CAT IV 600V, CAT. III 1000V,
Pollution Degree 2
EN
sFLEX 18A
12
Electromagnetic Compatibility Standards (EMC):
• EN 61326-1
Wireless Communications
• Bluetooth Low Energy (4.0)
• Radio Frequency: 2.4 GHz ISM Band
• Effective Ranges: Open air 10m
Electrical Specifications
Accuracy is given as ± (% of reading + counts of
least significant digit) at 23°C ± 5°C (≤ 80% R.H.)
AC Function
ACV and ACA specifications are ac coupled, true
RMS.
• For non-sinusoidal waveforms, Additional Accuracy
by Crest Factor (C.F.) :
Add 1.0% for C.F. 1.0 to 2.0
Add 2.5% for C.F. 2.0 to 2.5
Add 4.0% for C.F. 2.5 to 3.0
• Max. Crest Factor of Input Signal:
Frequency Response is specified for sine waveform.
Range Max. Crest Factor Limit
30A
300A
3000A
3.0
2.0
≤ 1500 counts
≤ 2250 counts
1000V
≤ 9999 counts
1.5
3.0
2.0
1.5
≤ 3000 counts
≤ 5000 counts
≤ 7500 counts
EN
sFLEX 18A
13
EN
sFLEX 18A
Range Resolution Accuracy
300A
30A *1 0.01A
0.1A
±(0.3% + 5D)
±(0.3% + 5D)
300A ±(0.3% + 5D)
1A
Position Error of Clamp
Voltage
*1 Minimum Reading is 3.0V
*2 Minimum Reading is +2.4V / -0.7V
AC Frequency Response : 45Hz to 500Hz
Input Impedance : >4kΩ for input voltage up to 30V,
impedance increases to >375kΩ when input voltage up
to 1000V.
Maximum Operation Time :
DT = 30sec for > 30V
Overload Protection: AC / DC 1000V
Model Distance from optimum Accuracy
sFLE
18A
1.4” (35mm) ±1.0%
2.0” (50mm) ±1.5%
2.4” (60mm) ±2.0%
AC Ampere
*1 Minimum Reading is 1.00A
Frequency Response : 45Hz to 500Hz
Overload Protection : 3000A
AC
DC
1000V *1
1000V *2
0.1V
0.1V
±(1.5%+5D)
±(0.7%+5D)
Function Range Resolution Accuracy
14
AC Frequency
Range Resolution Accuracy
1000Hz
0.1Hz ±(0.3%+3D)
1Hz ±(0.3%+3D)
0.01Hz ±(0.3%+3D)
100Hz *1
10kHz
*1 Minimum Reading is 10Hz
Minimum Sensitivity :
AC A: Reading > 3A at 40Hz to 1kHz, > 6A at
< 40Hz or > 1kHz
AC V: Reading > 10V at 40Hz to 1kHz, > 20V at
< 40Hz or > 1kHz
Resistance / Continuity
Continuity Indicator : Built-in buzzer sounds when
measured resistance is less than 20Ω and sounds off
when measured resistance is more than 200Ω,
between 20Ω to 200Ω the buzzer maybe sound or off
either.
Response Time of Buzzer : < 1ms
Maximum Output Voltage : 2.1V
Overload Protection : AC / DC 1000V
Measuring Rate & Response Time
Range Resolution Accuracy
10kΩ
±(0.9%+2D)
0.001kΩ ±(0.9%+2D)
1000Ω
Function Measuring Rate Response Time
A
2 sample(s) per sec 2 sec
1 sample(s) per sec 2 sec
3 sample(s) per sec 2 sec
V / Ω
Hz
EN
sFLEX 18A
15
Limited Warranty
This Meter is warranted to the original purchaser
against defects in material and workmanship for 3
years from the date of purchase. During this warranty
period, manufacturer will, at its option, replace or
repair the defective unit, subject to verification of the
defect or malfunction. This warranty does not cover
disposable batteries, or damage from abuse, neglect,
accident, unauthor-ized repair, alteration, contamina-
tion, or abnormal conditions of operation or handling.
Any implied warranties arising out of the sale of this
product, including but not limited to implied
warran-ties of merchantability and fitness for a
particular purpose, are limited to the above.
The manufacturer shall not be liable for loss of use
of the instrument or other incidental or consequen-tial
damages, expenses, or economic loss, or for any
claim or claims for such damage, expense or
economic loss. Some states or countries laws vary,
so the above limitations or exclusions may not apply
to you.
EN
sFLEX 18A
16
󱅞󸺥󰳅󹋂
!
!󲍨󱆔󲯫󷺴󷦼
󴇲󲵭󳴆󷲃󱖏󶜈󲑷󶤛󰴖󸆲󱁐󲎻󲽞󳾆󰳧󰱰󱓈󹀡󲳰󴆳󱙱󷙧󴢢
󱺞󰵕󷞰󸑳󱞊󳃘󲎌󰱰󱷛󰱰󳖢󲨌󰸴󵂬󷨅󱀕󼶳󱋟󷨅󱀕󳈡󰹡󰱰
󰻋󷳀󲯫󱍶󶜈󱖏󶜈󱕩󸾀
󷭃󰸴󵂬󱖮󸔸󰱰󵫹󲋺󱙱󵲘󱪡󸒡󷙧󴏯󸠉
󴢢󸽺󰷧󴠃󴠥󲽞󷦗󹃆󹎨󹀡󼶳󷭃󱐆󱫈󴬸󴢟󲯫󴃇󹟉󱘾󱪡󲽞󴘫
󴛤󱱚󲾧󰸴󵂬󳠘󵂤󱛂
󰸴󵂬󱋦󷭃󴏯󸠉󲠗󵕴󰱰󹃆󱵪󰵕󹛩󷱝󳷹󴏯󱃙󼴩󰱰󳽝󲡼󸓠
󷙧󱺞󳟘󵅏󲸢󼶳󷭃󸐞󰻥󳷹󴏯󼴩
󷭃󱐆󱫈󱃙󷚒󰰖󵫹󲋺󰱰󸹵󲽞󰵴󰷱󵫹󲋺󶥃󳇚󱫑󰱰󸹵󳖩󱍷
󷿄󸓪󹌰󲎌󰱰󹃆󱵪
󴢢󸕶󱅧󱖏󶜈󲑷󶤛󷦗󹃆󱙱󰴖󱛧󱁐󲎻󰱰󸪮󷫲󷳗󳔨󼶳󷭃󳖦󱉵
󴹰󰷧󹃆󸠉󹍧󵞑󳚈󵪰󱓋󳞭󳈷󹃆󴄣
󸕶󱅧󱠳󰴖󰷽󳯆󰵕󰺙󰴾󰴖󲣇󱎃
󱺞󳷹󴏯󼴩󸓠󰷽󵄠󲡼󲽞󴘫󴛤󼶳󷭃󱐆󰸴󵂬󳷹󴏯󼴩
󱺞󱃙󼴩󱖏󶜈󳇚󷦗󳻻󴏯󸠉󷝬󶏍󰱰󱓈󹀡󲡸󹃆󸘩󰵮󼶳󱋟󲭓󹋅
󰸴󵂬󴶑󵪰󵌴󰻋󷳀󷝬󶏍
󰸴󵂬󴏯󷩳󶄙󲽞󳇔󸠢󳚈󼶳󷭃󲑫󲿇󳃘󳓓󱫈󲿇󳃘󸽖󷳀󷝬󶏍󲫴
󷭃󴇲󲵭󰸴󵂬󹟗󳖦󽶵󽶲󽶶󽶴󲘊󰽭󲽞󽶸󽶲
󰱰󹃆󱵪󰰖󸏯󹃆󱵪󱖏󶜈󸑳󲽘󷦗󹃆
󲿓󸹨󹃆󴄣󶽏󲽞󱃙󷚒󱷛󴀐󰱰󱋦󼶳󷭃󲬎󱃙󷚒󰰖󱕨󰰗󷚒󵮜
󷭃󱐆󱫈󱆒󸘩󵌬󶩉󶀀󶄬󲓼󱷛󹄾󳚈󰸴󵂬󷚒󵮜
󷭃󱐆󰸴󵂬󷿄󸓪󳟅󱷼󹌰󲎌󰽭󰱰󴏯󷩳󶄙󴾬󱳠󹃆󱵪
󱙱󹃆󴉳󵮢󷺴󷦼󵌷󲠗󳖦󳇔󸠢󱙱󳇔󸠢󵫹󸘩󰻋󷳀󽨬󰰖󳴆󳘻
󷭃󱐆󱫈󱙱󴾬󱳠󰱉󰸴󵂬󴅰󳟘󳇔󸠢󰻋󷳀󽨬
󰱰󴏯󷩳󶄙
󵂬󳖦󴏯󸠉󰱰󳇔󸠢󵿟󰵮󲻖󵭟󱖮󽶸󽶳󽶲󽶳󽶲󽶲󽶵󽶳
󰱉󸔸󵂬󳖦󴏯󸠉󼳴󱊰󲽞󰱰󳴆󷨞󼶳󰰧󱆮󹌰󲎌󹃆󱵪󶤙
󲑾󲻖󵮢󳖦󲫩󴏯󹃆󸁠󵌴󹃆󱵪
󱫈󴏯󷩳󹃆󸽣󲑷󸑡󰳆󳯗󵱚󲽞󹃆󲏌󱋦󼶳󷭃󳖞󸹨󹃆󴒐󰰿󳓓
󹃆󲾧󳟘󹟗󱵪󹃆󲏌󼴩
󱺞󸈃󶄙󶀀󶄬󲓼󰱰󱆒󸘩󸥚󶄙󱷛󹄾󼶳󷭃󱐆󰸴󵂬󸈃󲯫󹃆󴉳󱁊
󲶋󼴩
󴇲󲵭
!
󷭃󸕘󲬢󰵕󰰗󷬁󳘻󰵕󵚮󰻋󱃙󼴩󰱰󲍨󱆔󳏪󰷽󶥃󶂶󰻥
󰰙󸕘󲍦󳠘󲿇󱇉󰱰󴇲󲵭󰳅󹋂󱖏󶜈󲑷󶤛󱨇󸠇󱁐󲎻󲽞󳾆󰳧
TC
sFLEX 18A
17
󱫈󲍨󷝬󱙱󳁸󱓓󸈃󲯫󹃆󴉳󳇔󸠢󳠀󸹵󼶳󷭃󲑫󷜉󴏯󷝬󶏍󳖞󹃆
󰰧󵧫󲾏󱖮󸔸󰱰󸽖󷳀󷚋󴯼
󷭃󱐆󲻖󳖦󲽞󵣱󸾞󳖦󳠕󶀀󶄬󵌴󱓈󹀡󲡸󹃆󲑷󹟉󱘾󱪡󼶳󳽞󱖏
󶜈󲑷󶤛󷦗󹃆󹃆󴠣󱁐󲽞󹃆󲨼󸹠󱅟
󱃙󼴩󱙱󳠘󲿇󱇉󰱉󰸴󵂬󰱰󳴆󷫀
!
󱕊󷣥󰸴󵂬󲿇󱇉
󷲝󱘕󽶬󱓈󹀡󹃆󱵪󷦗󹃆󹎨󹀡
󷲝󱘕
󷭃󱐆󰸴󵂬󲽞󵣱󸾞󳖦󱓈󹀡󲡸󹃆󲑷󹟉󰰖
󰳭󴉳󹃆󴉳󲽞󹃆󱵪
󵏣󴉳󹃆󴉳󲽞󹃆󱵪
󶥃
CAT IV
CAT III
󸓪󱵪󼳴󱊰
󷨅󱀕󳘀󱫈󸽖󳽜󱩿󲎌󷨅󱀕󲍨󷝬󰱉󰱰
󷨅󱀕󵌫󵂠󵔉󷳮󼶳󱺞󸛦󹃆󵏇󹔧󶄙󱙱󵖀󸁠
󱊈󳒻󹃆󸁠󰵕󱕗󱷼󱭕󲧨󵲤󴯼󰱰󴧩󳘻󵽎󶀶
󷨅󱀕󳘀󱫈󸽖󳽜󰹀󶤆󰱛󹃆󴒐󵾎󱊰󰱰
󵔉󷳮󼶳󱺞󹃆󸪽󲽞󳣡󵧞󲽞󱫑󰰗󲻖󵂬
󳇚󱫑
󱕩󹂂󲓼󲽞󱍷󲩜󶀀󶄬󰻋󷳀󰱰󷨅󱀕
󹃆󴄣󲏌󸠉
󴥝󶄙󸑿󶄙
󵭟󱖮󳼷󵎿󴒘󱋟
󷭃󱐆󰵴󲵭󰰷󳪑󳠘󵂤󱛂
󷲝󱘕
󷲝󱘕󷚒󵞑󱖏󶜈󳊈󱶂󱃙󼴩󷜉󴏯󷨅󱀕󲽞󲑷󶤛󷺴󳕣󴃨󰱧󲯫󸕨
󱸋󰱰󳩊󰵮󱙱󳏪󰷽
󱺞󱃙󼴩󲑫󸹐󳚈󸹵󷌊󳖦󲫩󵂬󴱼󲷞󼶳󲽞󲑫󲌈󳓓󳖦󽶷󽶲󰵕󰰖
󰱰󴒿󲤳󼶳󷭃󱕨󱉵󹃆󴄣󱺞󳠕󱕨󱉵󹃆󴄣󼶳󹃆󴄣󱖏󶜈󴖁󴌕󳊈
󱶂󱃙󷚒
󷭃󱐆󲑫󱃙󼴩󳜾󹄾󳖦󳯗󵫹󴒿󲤳󲽞󹟗󴛤󲤳󴾬󱳠
!
TC
sFLEX 18A
18
󱃙󼴩󳯯󸏯
󽶳󸤄󸭹󳶂󱋇
󽶴󹍧󵞑
󽶵󱍶󶜈󸬸
󽶶󸊘󱆎󵫹󲋺
󽶷󸊘󱆎󵫹󲋺
TC
sFLEX 18A
19
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78

APPA sFLEX 18A ユーザーマニュアル

カテゴリー
測定、テスト
タイプ
ユーザーマニュアル