Read this owner's manual thoroughly before operating the
appliance and keep it handy for reference at all times.
www.lg.com
Copyright © 2020 LG Electronics Inc. All Rights Reserved.
MODELS
W3NQ08UNNP1
*MFL71143113*
粵語
2
TABLE OF CONTENTS
TABLE OF CONTENTS
3 SAFETY INSTRUCTIONS
4 IMPORTANT SAFETY INSTRUCTIONS
8 PRODUCT OVERVIEW
8 Exterior Parts
8 Interior Parts
9 INSTALLATION
9 Circuit Breaker Installation
9 Installation Overview
10 How to Install the Unit
10 Drainage (Optional)
12 OPERATION
12 Control Panel and Remote Control
13 Using the Light Off Function
13 Using the Auto Clean Function
14 Wireless Remote Control
15 Air Direction
15 Slinger Fan
11 Installation of the Unit
11 Space for Outside Air Flow
18 MAINTENANCE
18 Air Filter
19 TROUBLESHOOTING
19 Before Calling for Service
19 Normal Sounds You May Hear
16 SMART FUNCTIONS
16 LG ThinQ Application
SAFETY INSTRUCTIONS
SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always
read and follow all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or injure you and others.
All safety messages will follow the safety alert symbol and either the word WARNING or
CAUTION.
These words mean:
WARNING
You may be killed or seriously injured if you do not follow instructions.
CAUTION
You may be injured or cause damage to the product if you do not follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce
the chance of injury, and tell you what may happen if the instructions are not followed.
The following symbols are displayed on units.
This symbol indicates that this appliance uses a flammable refrigerant. If the refrigerant is
is leaked and exposure to an external ignition source, there is a risk of fire.
This symbol indicates that the Operation Manual should be read carefully.
This symbol indicates that a service personnel should be handling this equipment with
reference to the Installation Manual.
This symbol indicates that information is available such as the Operating Manual or
Installation Manual.
3
EN
4
SAFETY INSTRUCTIONS
When the power cord is to be replaced, replacement work shall be performed by authorized
personnel only using only genuine replacement parts.
and authorized personnel only.
Installation work must be performed in accordance with the National Electric Code by qualified
Connect to a properly rated, protected, and sized power circuit to avoid electrical overload.
Always plug into a grounded outlet.
Do not under any circumstances, cut or remove the third (ground) prong from the power cord.
When installing or moving the appliance, be careful not to pinch, crush, or damage the power
cord.
Plug in the power plug properly.
Do not modify or extend the power cord.
Do not start/stop operation by plugging/unplugging the power cord.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified person in order to avoid a hazard.
Do not turn on the circuit breaker or power under condition that front grille, cabinet, control box
are removed or opened. Otherwise, it may cause fire, electric shock, explosion or death.
Use a dedicated circuit.
Do not disassemble or modify the product.
Adhere to all industry recommended safety procedures including the use of long-sleeved gloves
and safety glasses.
Use care when unpacking and installing. The edges of the product may be sharp.
Disconnect the power cord or circuit breaker before installing or servicing the appliance.
Keep packaging materials out of the reach of children. These materials can pose a suffocation
risk to children.
Store and install the product where it will not be exposed to temperatures below freezing or
exposed to outdoor weather conditions.
other appliance.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
IMPORTANT SAFETY INSTRUCTIONS
WARNING
injury to persons when using this product, follow basic precautions,
To reduce the risk of explosion, fire, death, electric shock, scalding or
including the following:
INSTALLATION
Before use, the appliance must be properly installed as described in this manual.
Contact the authorized service technician for repair or maintenance of this unit.
Contact the installer for installation of this unit.
The air conditioner is not intended for use by young children or invalids without supervision.
Keep any required ventilation openings clear of obstruction.
Compliance with national gas regulations shall be observed.
If water enters the product, turn off the power at the main circuit, then unplug the product and call
for service.
If the product has been submerged, contact the LG Electronics Customer Information Center for
instructions before resuming use.
Unplug the product when unused for long periods.
Unplug the product before cleaning.
In the event of a gas leak (propane gas, etc.) do not operate this or any other appliance. Open a
window or door to ventilate the area immediately.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning the use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the appliance.
The interior of the product must only be cleaned by a LG Electronics Customer Information
Center or a dealer.
Do not use solvent-based detergent on the product. Doing so can cause corrosion or damage,
product failure, electrical shock, or fire.
GROUNDING INSTRUCTIONS
The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this with
a standard three-slot (grounding) wall power outlet to minimize the hazard of electric shock. The
sure the receptacle is properly grounded.
customer should have the wall receptacle and circuit checked by a qualified electrician to make
DO NOT CUT OR REMOVE THE THIRD (GROUND)
PRONG FROM THE POWER PLUG.
Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the
appliance unless the cover screw is metal, and not insulated, and the wall receptacle is grounded
to make sure the receptacle is properly grounded.
through the house wiring. The customer should have the circuit checked by a qualified electrician
Disconnect the power cord from the adapter, using one hand on each. Otherwise, the adapter
ground terminal might break. Do not use the appliance with a broken adapter plug.
-
situations. Unplugging the power cord frequently can lead to an eventual breakage of the
Situations when the appliance will be disconnected often; Do not use an adapter plug in these
ground terminal. The wall power outlet should be replaced by a three-slot (grounding) outlet
instead.
-
hazards, we strongly discourage the use of an adapter plug.
Situations when the appliance will be disconnected occasionally; Because of potential safety
OPERATION
Use this appliance only for its intended purpose.
Never attempt to operate this appliance if it is damaged, malfunctioning, partially disassembled,
or has missing or broken parts, including a damaged cord or plug.
Repair or immediately replace all power cords that have become frayed or otherwise damaged.
Do not use a cord that shows cracks or abrasion damage along its length or at either end.
Do not run cord under carpets or mats where it could be stepped on and damaged.
Keep the cord out from under heavy objects like tables or chairs.
Do not place the power cord near a heat source.
Do not use an adaptor or plug the product into a shared outlet.
Do not tamper with controls.
If you detect a strange sound, a chemical or burning smell, or smoke coming from the appliance,
unplug it immediately, and contact an LG Electronics Customer Information Center.
straight out from the outlet.
Never unplug the appliance by pulling on the power cord. Always grip the plug firmly and pull
Do not grasp the power cord or touch the appliance controls with wet hands.
SAFETY INSTRUCTIONS
5
EN
6
SAFETY INSTRUCTIONS
CAUTION
To reduce the risk of minor or moderate injury to persons, malfunction, or
damage to the product or property when using this product, follow basic
precautions, including the following:
INSTALLATION
Take care when installing the product that exhaust or condensation does not damage nearby
property.
Follow installation instructions exactly to avoid excessive vibration or water leakage.
OPERATION
This appliance is not intended for use as a precision refrigeration system. Do not use it for special
purposes such as maintaining pets, food, precision machinery, or art objects.
When installing or moving the appliance, be careful not to pinch, crush, or damage the power
cord.
Make sure the air inlet and outlet are free from obstructions.
Use a soft cloth to clean the appliance. Do not use waxes, thinners, or harsh detergents.
Do not step on or place heavy objects on top of the appliance.
Do not drink water drained from the appliance.
Do not operate the appliance without the filter securely installed.
are used simultaneously.
Being exposed to direct airflow for an extended period of time could be hazardous to your health.
Be sure to ventilate sufficiently when the air conditioner and a heating appliance such as a heater
Remove the batteries if the remote control is not to be used for an extended period of time.
Never mix different types of batteries, or old and new batteries for the remote control.
Stop using the remote control if there is a fluid leak in the battery. If your clothes or skin are
exposed to the leaking battery fluid, wash off with clean water.
If the leaking battery fluid has been swallowed, rinse the inside of the mouth thoroughly and
consult a doctor.
Do not recharge or disassemble the batteries.
MAINTENANCE
Never use strong cleaning agents or solvents when cleaning the air conditioner or spray water.
Clean the filter every two weeks.
Never touch the metal parts of the air conditioner when removing the air filter.
Use a smooth cloth.
Do not install the appliance in an area where it is directly exposed to sea air (salt spray).
− Saline conditions are a cause of corrosion. (Particularly, corrosion of the condenser and
Set up windbreak in front of the outdoor unit if installing it in coastal areas.
− Avoid direct exposure to salt winds.
− Install a firm and stiff concrete-wind shield that can withstand salt winds.
evaporator can damage the appliance or impair its performance.)
REFRIGERANT (FOR R32 ONLY)
WARNING
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating open flames (for example
Servicing shall only be performed as recommended by the equipment manufacturer.
The appliance shall be stored so as to prevent mechanical damage from occurring.
an operating gas appliance) and ignition sources (for example an operating electric heater).
Do not pierce or burn. Be aware that flammable refrigerants may not contain an odor.
The appliance shall be stored in a well-ventilated area where the room size corresponds to the
room area as specified for operation.
As the minimum installation height is 75cm. Please be aware the requirement of installation
height.
Based on IEC 60335-2-40, there is no restriction for the minimum installation floor area since the
refrigerant charges is less than 1.224 kg.
current valid certificate from an industry-accredited assessment authority, which authorises their
Technical Safety
Any person who is involved with working on or breaking into a refrigerant circuit should hold a
competence to handle refrigerants safely in accordance with an industry recognised assessment
specification.
Maintenance and repair requiring the assistance of other skilled personnel shall be carried out
under the supervision of the person competent in the use of flammable refrigerants.
SAFETY INSTRUCTIONS
7
EN
8
PRODUCT OVERVIEW
PRODUCT OVERVIEW
Exterior Parts Interior Parts
4 35
7
8
1
2
9
1
Evaporator
2
Air Guide
3
Control Box
4
Condenser
5
Compressor
6
Base Pan
7
Power Cord
1
Control Panel
2
Remote Control
3
Air Inlet
Air Filter
Vertical Air Deflector (Horizontal Louver)
Horizontal Air Deflector (Vertical Louver)
4
5
6
7
Front Grille
8
Cabinet
9
Air Outlet
1
2
3
5
4
6
7
6
Circuit Breaker Installation
Installation Overview
Foam
Tools Needed
INSTALLATION
Phillips-head
screwdriver
Flat-blade screwdriver LevelPencil
Tape measure Cutting knife Scissors
Main Power source
Circuit Breaker
Use a circuit breaker
or time delay fuse.
Read thoroughly and follow all directions provided.
A circuit breaker must be installed between the power source and the unit if the plug is not used
(see illustration below).
NOTE
Use 15 A circuit breaker.
INSTALLATION
Drain pipe
9 EN
10
INSTALLATION
How to Install the Unit
1
Measure the space for installation to assure
a good fit. The air conditioner must be
2
Avoid exposure to direct sunlight.
installed firmly into place to prevent vibration
and noise.
There must be at least 50 cm (20 in.) of
cleared space around the rear of the unit.
Obstacles restricting the airflow may reduce
the cooling efficiency of the unit.
3
Remove all obstacles from the rear of the unit.
towards the outside to allow condensed water
to drain. (About 10~15 mm or 1/4 bubble with
Level)
4
The unit should be installed with a slight tilt
Fence
Awning
Heat
radiation
Cooled air
CAUTION
The external grille must be exposed outside
for air discharge.
As the minimum installation height is 75cm.
Please be aware the requirement of
installation height.
CAUTION
Take care when inserting the drain pipe.
Push away from the sharp edge to avoid
slipping and injuring yourself.
10~15 mm
Over 50 cm
Foam
Th
ermos
tat
6
4
8
9
5
1
2
3
7
C
O
O
L
E
R
Level
1/4 Bubble
1
Remove the rubber cap from the hole under
the base-pan.
and pushing.
2
Press the drain pipe into the hole by hanging
on the bottom of the drain pipe. (You can
3
Connect the drain hose to the outlet located
satisfy your particular needs. Drain hose is not
supplied)
purchase the drain hose or tubing locally to
Drainage (Optional)
To drain the excess water, remove the drain cap
The base-pan may overflow due to high humidity.
from the base pan of the unit and secure the drain
pipe.
2
1
(Minimum
75-150cm
height is 75cm)
installation
INSTALLATION
Installation of the Unit
Space for Outside Air Flow
NOTE
bottom of the unit is well supported,
the top has minimum clearace and the
air inlet louveres have clearance as
shown. Holes from the outside through
to the cavity should be sealed. The
unit should slope down towards
the rear by about 10~15 mm to allow
water formed during operation to drain.
1
Prepare the hole in the wall so that the
Ensure the foam seals are not damaged.
Flash, seal or fill gaps around the inside
and outside to provide satisfactory
appearance and protection against the
weather, insects and rodents.
2
Install the unit into the wall and secure.
Unit may be supported by a solid frame from
below or by a hanger from a solid overhead
support.
FLASH OR SEAL AROUND EXTERNAL
WALL FRAME OR ARCHITRAVE
STURDY TIMBER
FRAME ALL ROUND
UNIT
DRAIN PIPE
EXTERNAL SUPPORT
FRAME AT BALANCE
POINT OF RAC
Preferred method of installation into
a timber framed wall, partition or window.
ALTERNATIVELY, BRACKETS
AS ILLUSTRATED BELOW
MAY BE USED.
TIMBER FRAMED
WALL OR PARTITION
100 mm minimum
AIR IN
AIR IN
AIR OUT
OPTION A
The Foam
(Around the unit)
CAUTION
Use an assistant to help lift the unit and set
it in place. Lifting and maneuvering the unit
by yourself could result injury.
100 mm
100 mm
110~180 mm
LOUVRE
FRONT
45° BRICK CUT AWAY
TO CLEAR LOUVRES
45° BRICK CUT AWAY
TO CLEAR LOUVRES
BRICK
WALL
AIR INAIR IN
BRICK
WALL
AIR OUT
TOP VIEW
OPTION B
11 EN
OPERATION
Control Panel and Remote Control
12
OPERATION
Remote Control
1
Power
Press to turn the air conditioner ON or OFF.
2
Sleep Mode
This mode keeps operating noise to a
minimum and turns the air conditioner off
after a set time. The timer can be set from
1 to 7 hours.
3
Delay ON/OFF Timer
Delay ON - When the air conditioner is off,
set it to automatically turn on from 1 to 24
hours later, at its previous mode and fan
settings.
Delay OFF - When the air conditioner is off,
set it to automatically turn off from 1 to 24
hours later.
NOTE
Each press of the Timer button advances
the timer by 1 hour. After the last press
the display returns to the temperature
setting.
4
Operation Mode
Press the Mode button to cycle between
4 types of air conditioner operation: Energy
Saver / Cool / Fan / Dry.
Cool - This mode is ideal on hot days to
cool and dehumidify the room quickly. Use
the Temp
buttons to set the desired
room temperature and use the Fan Speed
button to set the desired fan circulation
speed.
Energy Saver - In this mode the
compressor and fan turn off when the set
temperature is achieved. Approximately
every 3 minutes the fan turns on to allow
the unit sensor to accurately determine if
more cooling is needed.
Fan - In this mode the fan circulates air
but the compressor does not run. Use the
Fan Speed button to set fan speed to High,
Medium or Low. In this mode, you cannot
adjust the set temperature.
Dry - This mode is ideal for rainy and
damp days to dehumidify the room rather
than cooling it significantly. Humidity is
removed from the room by the combination
of compressor operation and the fan speed
off once the set temperature is reached.
Fan speed cannot be adjusted in Dry mode.
fixed at Low. The compressor and fan turn
In the Cool, Energy Saver, Dry Mode, the
setting temperature increases by 1 °C
after 30 minutes and additional 1 °C
The setting temperature increases up to
2 °C from the preset temperature.
after another 30 minutes for a more
comfortable sleep.
4 3 2 1
5 76
8
5
Wi-Fi
Enables connection of the air conditioner to
● Wi-Fi Pairing : Mode + Fan Speed
● Wi-Fi Off : Power + Fan Speed
the home Wi-Fi.
1
4
3
10
2
7
8
9
Auto Clean(3 s)
Light Off(3 s)
NOTE
The feature may be changed according to the type of model.
OPERATION
6
Clean Filter
Using the Light Off Function
The Clean Filter LED lights up to notify you
that the filter needs to be cleaned. After
cleaning the filter, press
You can set the brightness of the control panel.
7
Fan Speed
Press to set the fan speed to Low (F1),
Medium (F2), or High (F3).
8
Temperature Control
The thermostat monitors room temperature
to maintain the desired temperature. The
thermostat can be set between 16 °C–30 °C
(60 °F–86 °F). Press
9
Energy Saver
In this mode the compressor and fan turn
off when the set temperature is achieved.
Approximately every 3 minutes the fan turns
on to allow the unit sensor to accurately
determine if more cooling is needed.
10
Clear
Cancel Sleep and Timer settings. Also set
the Diagnosis if held for 5 seconds.
NOTE
Auto Restart: If the air conditioner turns off due
to a power outage, it will restart automatically
once the power is restored, with the same
settings as were set before the unit turned off.
Energy Saver: The unit defaults to the Energy
Saver mode each time the unit is switched on
except in Fan mode or when power is restored
after an electrical power outage.
The remote control will not function properly if
the AC infrared sensor is exposed to direct light
or if there are obstacles between the remote
controller and the air conditioner.
Temp
and
together on the control panel to turn off the
Clean Filter light.
NOTE
control panel, not the remote control.
The filter reset must be done using the
filter for more efficient operation. The LED
This feature is a reminder to clean the air
light turns on after 250 hours of operation.
or arrows to
increase or decrease temperature setting.
NOTE
This function is available with Cooling
Mode.
NOTE
Turn on/off the control panel.
Press Mode button on the remote control for
3 seconds, or
Press Mode and Sleep button together on the
control panel.
Using the Auto Clean Function
In the Cooling and Dry Mode, Moisture is
removes such moisture.
generated inside the indoor unit. This function
NOTE
If you turn off the unit, the fan continues to run
for 10 minutes and cleans the inside of the
indoor unit.
Press Energy Saver button on the remote
control for 3 seconds.
is displayed on the remote control.
13 EN
14
OPERATION
Wireless Remote Control
Inserting Batteries
If the display screen of the remote control begins
to fade, replace the batteries. Insert AAA (1.5 V)
batteries before using the remote control.
1
Remove the cover on the back of the
remote control.
2
Insert the new batteries and make sure that
the + and - terminals of the batteries are
installed correctly.
NOTE
New batteries are supplied with the air
conditioner for use in the remote control.
Do not use a rechargeable battery. Make sure
that the battery is new.
In order to prevent discharge, remove the
battery from the remote control if the air
conditioner is not going to be used for an
extended period of time.
Keep the remote control away from extremely
hot or humid places.
To maintain optimal operation of the remote
control, the remote sensor should not be
exposed to direct sunlight.
OPERATION
Air Direction
Adjusting Horizontal Airflow
Adjusting Vertical Airflow
of the air conditioner’s louvers.
Airflow can be adjusted by changing the direction
The horizontal airflow is adjusted by moving the
Touch the horizontal louvers to adjust the airflow
Direction
levers of the vertical louvers to the left or right.
Direction
up or down.
NOTE
When the weather is extremely hot, the unit
may turn off automatically to protect the
compressor.
Slinger Fan
This air conditioner is equipped with a slinger
fan. (See drawing.)
The fan’s outer ring picks up the condensed
water from the base pan if the water level gets
high enough. The water is then picked up by the
fan and expelled through the condenser, making
the air conditioner more efficient.
Ring
15 EN
SMART FUNCTIONS
16
SMART FUNCTIONS
The LG ThinQ application allows you to
communicate with the appliance using a
smartphone.
Communicate with the appliance from a
smartphone using the convenient smart features.
the or ThinQ logo
1
Check the distance between the appliance
and the wireless router (Wi-Fi network).
If the distance between the appliance and
the wireless router is too far, the signal
strength becomes weak. It may take a
long time to register or installation may
fail.
2
Turn off the Mobile data or Cellular Data
on your smartphone.
3
Connect your smartphone to the wireless
router.
NOTE
To verify the Wi-Fi connection, check that
icon on the control panel is lit.
The appliance supports 2.4 GHz Wi-Fi
networks only. To check your network
frequency, contact your Internet service
provider or refer to your wireless router
manual.
LG ThinQ is not responsible for any network
connection problems or any faults,
malfunctions, or errors caused by network
connection.
If the appliance is having trouble connecting to
the Wi-Fi network, it may be too far from the
router. Purchase a Wi-Fi repeater (range
extender) to improve the Wi-Fi signal strength.
The Wi-Fi connection may not connect or may
be interrupted because of the home network
environment.
The network connection may not work
properly depending on the Internet service
provider.
The surrounding wireless environment can
make the wireless network service run slowly.
The appliance cannot be registered due to
problems with the wireless signal
transmission. Unplug the appliance and wait
about a minute before trying again.
If the firewall on your wireless router is
enabled, disable the firewall or add an
exception to it.
The wireless network name (SSID) should be
a combination of English letters and numbers.
(Do not use special characters.)
Smartphone user interface (UI) may vary
depending on the mobile operating system
(OS) and the
manufacturer.
If the security protocol of the router is set to
WEP, you may fail to set up the network.
Please change it to other security protocols
(WPA2 is recommended) and register the
product again.
LG ThinQ Application
This feature is only available on models with
LG ThinQ Application Features
If you experience a problem while using the
appliance,this smart diagnosis feature will help
you diagnose the problem.
Smart Diagnosis
Allows you to set various options on the
appliance and in the application.
Settings
Before Using LG ThinQ Application
TM
NOTE
If you change your wireless router, internet
service provider, or password, delete the
registered appliance from the LG ThinQ
application and register it again.
The application is subject to change for
appliance improvement purposes without
notice to users.
Functions may vary by model.
SMART FUNCTIONS
17 EN
Using Audible Diagnosis to
Diagnose Issues
Follow the instructions below to use the audible
diagnosis method.
Installing the LG ThinQ
Application
Search for the LG ThinQ application from
the Google Play Store or Apple App Store on a
smartphone. Follow instructions to download
and install the application.
Open Source Software Notice
Information
To obtain the source code under GPL, LGPL, MPL,
and other open source licenses, that is contained
in this product, please visit http://opensource.lge.
com.
In addition to the source code, all referred license
terms, warranty disclaimers and copyright notices
are available for download.
LG Electronics will also provide open source code
to you on CD-ROM for a charge covering the cost
of performing such distribution (such as the cost of
media, shipping, and handling) upon email request
to [email protected]. This offer is valid for a
period of three years after our last shipment of this
product. This offer is valid to anyone in receipt of
this information.
Smart Diagnosis
This feature is only available on models with the
or logo.
Use this feature to help you diagnose and solve
problems with your appliance.
NOTE
TM
For reasons not attributable to LGE’s
negligence, the service may not operate due to
external factors such as, but not limited to, Wi-Fi
unavailability, Wi-Fi disconnection, local app
store policy, or app unavailability.
Launch the LG ThinQ application and select the
Smart Diagnosis feature in the menu. Follow
the instructions for audible diagnosis provided in
the LG ThinQ application.
NOTE
For best results, do not move the phone while the
tones are being transmitted.
The feature may be subject to change without
prior notice and may have a different form
depending on where you are located.
Be sure to keep ambient noise to a minimum or
the phone may not correctly receive the buzzer
beeps from the indoor unit.
Using LG ThinQ to Diagnose
Issues
If you experience a problem with your Wi-Fi
equipped appliance, it can transmit troubleshooting
data to a smartphone using the LG ThinQ
application.
Launch the LG ThinQ application and select
the Smart Diagnosis feature in the menu.
Follow the instructions provided in the LG
ThinQ application.
TM
1
Plug the power plug in the outlet properly.
4
After the data transfer is complete, the diagnosis
will be displayed in the application.
3
Press and hold the DIAGNOSIS [5 s] button for
5 seconds or longer while holding the smartphone
mouthpiece to the logo until the data transfer is
complete.
2
Place the mouthpiece of your smartphone close
to the
Keep the smartphone in place until the data
transfer has finished. Time remaining for data
transfer is displayed.
or logo.
TM
18
MAINTENANCE
2
40 °C (104 °F).
Wash the filter using lukewarm water below
3
Gently shake the excess water from the
filter.
4
Dry the filter in the shade.
5
Insert the filter into the Front grille.
Cleaning the Air Conditioner
Wipe the front grille and inlet grille with a cloth
dampened in a mild detergent solution.
Wash the cabinet with mild soap or detergent
and lukewarm water, then polish using liquid
appliance wax.
NOTE
condenser coils (outside of unit) should be
To ensure continued peak efficiency, the
checked periodically and cleaned if clogged
with soot or dirt from outside air.
For repair and maintenance, contact a LG
Electronics Customer Service Hotline. Have
your model number and serial number
available.
MAINTENANCE
WARNING
Before cleaning or performing maintenance,
disconnect the power supply and wait until
the fan stops.
Air Filter
if cleaning is necessary. Trapped particles in the
filter can build up and block the airflow, reducing
Check the air filter at least twice a month to see
cooling capacity and causing an accumulation of
frost on the evaporator.
Remove the air filter from the front grille by
pulling the filter forward and then up slightly.
Cleaning the Air Filter
1
TROUBLESHOOTING
TROUBLESHOOTING
Before Calling for Service
The appliance is equipped with an automatic error-monitoring system to detect and diagnose problems
at an early stage. If the appliance does not function properly or does not function at all, check the
following before you call for service.
Normal Sounds You May Hear
1
2
3
4
5
1
High Pitched Chatter
2
Sound of Rushing Air
At the front of the unit, you may hear the sound of rushing air being moved by the fan.
3
Gurgle/Hiss
Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during
normal operation.
4
Vibration
Unit may vibrate and make noise because of poor wall or window construction or incorrect
installation.
5
Pinging or Swishing
Droplets of water hitting condenser during normal operation may cause pinging or swishing
sounds.
19 EN
Today's high efficiency compressors may have a high pitched chatter during the cooling cycle.
Problem Possible Causes & Corrective Action
Air conditioner does
not start.
The air conditioner is unplugged.
Make sure the air conditioner plug is pushed completely into the outlet.
The fuse is blown/circuit breaker is tripped.
Check the house fuse/circuit breaker box and replace the fuse or reset
the breaker.
Power failure.
If power failure occurs, turn the mode control to off. When power is
restored, wait 3 minutes to restart the air conditioner to prevent ng of the
compressor overload.
Air conditioner does
not cool as it should.
Airflow is restricted.
Make sure there are no curtains, blinds, or furniture blocking the front of
the air conditioner.
The temp control may not be set correctly.
Set the desired temperature to a level lower than the current temperature.
The air filter is dirty.
Clean the filter at least every 2 weeks. See the 'MAINTENANCE
(Cleaning the Air Filter)' section.
The room may have been hot.
When the air conditioner is first turned on, you need to allow time for the
room to cool down.
Cold air is escaping.
Check for open fumace floor registers and cold air returns.
Cooling coils have iced up.
See 'Air conditioner freezing up' below.
Air conditioner freez-
ing up.
The cooling coils are iced over.
Ice may block the air flow and obstruct the air conditioner from properly
cooling the room. Set the Fan Speed High at Fan or Cool mode.
Water drips outside.
Hot, humid weather.
This is normal.
20
TROUBLESHOOTING
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

LG W3NQ08UNNP1 取扱説明書

カテゴリー
スプリットシステムエアコン
タイプ
取扱説明書
このマニュアルも適しています

他の言語で