Hitachi RD-110EX ユーザーマニュアル

カテゴリー
除湿機
タイプ
ユーザーマニュアル
Thank you very much for your purchasing of the Hitachi
Dehumidifier. Please read this Instruction Manual well
to use the dehumidifier correctly and keep this Instruc-
tion Manual at a certain place for future reference.
,。
,。
,。
CONTENTS
BEFORE YOU BEGIN .................................................2
USEFUL IN THE FOLLOWING CASES.....................2
CAUTIONS FOR SAFETY ..........................................3
• CAUTIONS ON INSTALLATION ........................3~4
CAUTIONS ON USE .............................................4~6
• CAUTIONS FOR REPAIR .........................................6
INDISPENSABLE KNOWLEDGE FOR
DEHUMIDIFIER.............................................7~8
NAME AND FUNCTION OF EACH PART ................8
OPERATION PANEL ....................................................9
HOW TO OPERATE .............................................10~13
EFFICIENT USE OF DEHUMIDIFIER .....................13
ADDITIONAL CAUTIONS ........................................14
MAINTENANCE AND INSPECTION ................15~17
STORING DEHUMIDIFIER ......................................17
WHEN REQUIRING REPAIR SERVICE ............18~19
SPECIFICATIONS ......................................................20
OPTIONAL ACCESSORIES ......................................20
• DRAINING DEHUMIDIFIED WATER
CONTINUOUSLY ...................................................21
• CAUTIONS IN THE USE OF THE DEHUMIDIFIER
IN CONTINUOUS DRAINAGE .............................21
Thoroughly read this instruction manual to ensure correct use, and keep the manual in a handy place for future reference.
RD-110EX
01
,。,。
................................................................................2
.........................................................................2
.................................................................3
..................................................3~4
..................................................4~6
.....................................................6
...................................................................7~8
......................................................8
........................................................................9
.............................................................10~13
...........................................................13
.......................................................................14
............................................................15~17
............................................................17
.............................................................18~19
................................................................................20
........................................................................20
.........................................................21
.....................................21
INSTRUCTION MANUAL FOR THE HITACHI DEHUMIDIFIER RD-110EX
HOW TO USE
BEFORE YOU BEGIN
USEFUL IN THE FOLLOWING CASES:
Use the dehumidifier effectively.
This dehumidifier is for general household use: Do not use it for such purposes as storing food, precision equipment, art
objects, medicines, etc.
。,,,。
Carpet is damp.
Faster drying of clothes in a
room.
Drawers of wardrobe are
difficult to pull out because
contents are damp.
Moisture adheres to ceiling or
walls, or they are moldy.
Clothes and leather goods are
moldy or stained.
,,
Sound from piano is distorted
or its keys are heavy.
To keep CDs, books, cameras,
etc. dry.
,,
,。
,,。
CAUTIONS FOR SAFETY
Read the following thoroughly before starting operation for correct use.
Be sure to observe the following cautions that are critical for safety.
The indications and meanings of cautions shown here are as follows:
The icons have the following meanings:
After reading, be sure to keep the manual in a place where you can refer to it anytime.
,。
CAUTIONS ON INSTALLATION
indicates a potentially very hazardous situation, which could result in death or serious injury.
indicates a potentially hazardous situation, which could result in minor or moderate injury, or
damage to device.
WARNING
CAUTION
Indicates prohibition.
Be sure to unplug the power cord from AC outlet.
Do not splash water on dehumidifier or get it wet.
,。
Instructions to be observed strictly.
,,。
,。
Use only on a horizontal and stable spot:
If the dehumidifier falls during use, the water
inside will leak and wet household goods: At
worst, it could result in electric shock or fire
caused by a short-circuit.
Do not use in a narrow space, such as in
closet or between pieces of furniture:
Doing so will deteriorate air ventilation, which
could cause heat generation or fire.
Do not use in a place where water is likely
to splash:
This could cause electric shock or fire as a result
of short-circuit.
Do not install the dehumidifier in a place
where oil or inflammable gas could leak:
If oil or gas leaks and accumulates around the
dehumidifier, it could cause fire or explosion.
,。
,,。
Closet and its contents are
damp.
32
Less than 5mm
5mm
Strictly observed
Strictly observed
Prohibited
Prohibited
Prohibited
Prohibited
CAUTION
CAUTION
Prohibited
Prohibited
CAUTIONS ON INSTALLATION (CONTINUED)
Do not place a container with water, such
as a vase, on dehumidifier:
If it falls and water enters the dehumidifier,
the electrical insulation will deteriorate, which
could cause electric shock or fire as a result of
short-circuit.
Do not hold the power plug with wet hand:
Doing so could cause electric shock.
Be sure to use the dehumidifier with the
rated voltage (single-phase 220V):
Using with a voltage other than the rated one
could result in electric shock or fire.
Do not bend the power cord forcibly:
Doing so could cause electric shock or fire as a
result of short-circuit.
Do not insert your finger or rod into the
air outlet or inlet:
This could result in injury since the fan inside
rotates at high speed.
Do not place the dehumidifier near any
heating appliance:
Doing so could deform the plastic parts or ignite
a fire.
Do not hold the cord when pulling out
the power cord:
Doing so could disconnect part of core wires,
which could result in heat generation or fire
ignition.
When cleaning the dehumidifier, be sure
to stop it and pull out the power cord
from the AC outlet:
Neglecting this could cause injury since the fan
inside rotates at high speed.
If you do not use the dehumidifier for a
long period of time, unplug the power
cord from the AC outlet for safety:
Neglecting this could result in electric shock or
fire as a result of short-circuit.
Do not place any heating appliance
where the air from the dehumidifier
blows directly:
Doing so could cause incomplete combustion
of the heater, resulting in gas or oil fumes.
Do not block the air inlet or outlet with a
cloth, etc.:
Doing so will deteriorate ventilation, and could
cause heat generation or fire ignition.
,,
Do not mount the dehumidifier or sit on it:
Falling or stumbling could cause injury.
,。
Make sure that no dust adheres to the
power plug, and securely insert plug up
to the roots of prongs:
Dust or incomplete connection could cause
electric shock or fire.
Do not damage or modify the power cord
in any way: Doing so could cause electric
shock, heat generation or fire.
Do not place any heavy object on the power
cord, or subject it to heat or stretch it: Doing so
will damage the cord.
Do not start or stop the dehumidifier by
plugging in or unplugging the power cord:
Doing so could cause electric shock or fire.
The dehumidifiers exclusively for indoor
use. Do not use it in a place which is
exposed to direct sunlight, rain or wind:
This could cause electric shock or fire as a
result of short-circuit.
Do not use the dehumidifier for special
purposes such as keeping art objects,
scientific materials, etc. dry:
Doing so could deteriorate the quality of the
stored goods.
When performing continuous drainage,
do not make ambient temperature of the
drain hose drop below freezing point.
Water inside the drain hose freezes and water
inside the dehumidifier can spill in the room and
wet the property such as furniture.
For continuous drainage, attach a hose
for secure drainage, taking care with
bending of hose or drops in water level:
Neglecting this could allow the water in
dehumidifier to leak and wet household goods.
WARNING
CAUTION
,。
,,。
,。
CAUTIONS ON USE
CAUTIONS ON USE (CONTINUED)
54
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Prohibited
Strictly observed
Strictly observed
Strictly observed
Strictly observed
Strictly observed
Strictly observed
Unplug
Unplug
Unplug
Unplug
220 V/
Prohibited
Prohibited
Prohibited
CAUTIONS ON USE (CONTINUED)
CAUTIONS FOR REPAIR
Do not wash the dehumidifier with water:
Doing so could cause electric shock.
When moving the dehumidifier, be sure
to stop it completely and dispose of the
water in water receptacle:
If disposal of water is neglected, water will leak
either inside the dehumidifier or outside, which
could wet household goods, cause electric shock
or fire as a result of short-circuit.
When using the dehumidifier without any-
one attendant, inspect it periodically:
Neglecting inspection could result in heat gen-
eration or water leak.
If the ambient temperature of dehumidifier
drops below zero, do not leave the water
in water receptacle as is:
Neglecting disposal will allow the water to freeze,
which could crack the receptacle, causing water leak.
If any abnormality occurs in the dehu-
midifier (smelling scorch, etc.), imme-
diately turn it off, unplug the power cord,
and consult your dealer:
Continuing operation with abnormality left as
is could cause electric shock or fire.
Do not attempt to repair the dehumidifier
yourself:
Be sure to ask your dealer for repair.
WARNING
INDISPENSABLE KNOWLEDGE FOR DEHUMIDIFIER
Read the following items carefully and avoid using the dehumidifier outside the specified available range.
The dehumidifier does not have any cooling function. On the contrary, it generates heat during operation:
the room temperature will rise by 1-2°C.
Install the dehumidifier at least 1 m away from your TV, radio, and radio antenna, to prevent image distortion
or interference.
A protection device may act at high
temperature, stopping operation
to prevent excessive strain.
This dehumidifier is not suitable
for maintaining humidity at less
than 50%.
This dehumidifier removes moisture that
is a bother in everyday life (damage due
to dampness, discomfort, etc.)
The dehumidification level also varies
depending on the room temperature.
The lower the temperature, the less the
dehumidification amount, as shown in
the diagram.
Do not pull the power cord during the
operation.
Children should be supervised to ensure
that they do not play with the appliance.
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless
they have been given supervision or
instruction concerning use of the appliance
by a person responsible for their safety.
Prohibited
Do not pull the power cord when the
dehumidifier is moved.
Improper use may cause fire due to electric
shock or heat generation.
Prohibited
Prohibited
Strictly observed
Strictly observed
Make sure to pull the power plug by
holiding the plug, not cord.
Strictly observed
Strictly observed
Strictly observed
Strictly observed
Unplug
Prohibited
Refer to the table on the right for
the floor space required for the
dehumidifier to be used.
The room space where the dehumidifier
can be used differs depending on the
structure of house etc.: Use the table on
the right for reference.
Dehumidification amount (l/d)
5
0
10
11.5L
10
15 20 25 30
2.5
7.5
11.5
The compressor stops during
defrosting.
If the temperature drops to about 13
°C
or lower, since frost forms on the cooler,
the compressor is stopped for defrosting.
Frequency of defrosting varies depend-
ing on the temperature and humidity at
that time.
,。
76
0
10
-10
-20
20
30
40
50
Frost
Compressor stops /
Frost
20 40
Adequete
humidity
Low humidity
(
less than 50%
)
High
humidity
Restored from
power failure.
NAME AND FUNCTION OF EACH PART
If 2 units of dehumidifier operate in the
same room at the same time, dehumidi-
fying amount differs from each other.
The dehumidifier of which humidity sensor
has lower function has priority to operate
over the other dehumidifier. Thus,
dehumidifying amount will differ from
each other after certain time has elapsed.
In Case of Power Failure while
Using the Dehumidifier...
When restored from power failure, operation
mode automatically returns to the one which
was set prior to the power failure.
When restored from power failure
while OFF timer is set, the OFF timer
and swing remain set.
FRONT PANEL /
REAR PANEL /
REAR OF WATER RECEPTACLE /
Air outlet
Dehumidified dry air is released.
Air filter (Page 15)
Air inlet opening
Humid air is drawn into the inlet opening.
Drain outlet
Dehumidified water is drained from the
drain outlet.
Handle
The handle is used to move the dehumidifier or
to move it down steps or stairs. (
Page 13)
,。
Water receptacle
Dehumidified water is contained in the water
receptacle. The operation is automatically stopped
once the receptacle is full. Amount of dehumidified
water can be known at a glance. (
Page 12)
,。
Operation panel (Page 9)
OPERATION PANEL
Continuous dehumidifying lamp (Page 10)
DEFROST lamp (Page 12)
The lamp is turned on during the defrost operation.
POWER Switch (Page 10)
The dehumidifier is turned on/off.
FULL WATER lamp (Page 12)
The lamp is turned on when the water receptacle is full.
Humidity setting lamp (40%, 50% or 60%)
(Page 10)
The lamps are turned on when the humidity mode is set.
TIMER Switch (Page 11)
OFF timer can be set at 2, 4, or 6 hours.
HUMIDITY Switch (Page 10)
Target humidity can be set (40%, 50% or 60%).
In continuous dehumidifying mode, dehumidifying is operated
continuously.
POWER lamp (Page 10)
The lamp is turned on during the operation.
1
9
2
3
4
5
6
7
8
12389 4567
Louver (Page 10)
Handle of water receptacle
The handle is pulled out to remove the
water receptacle.
Lid of water receptacle
The lid is removed when the dehumidified
water is drained. (
Page 14)
TIMER lamp (Page 11)
The lamps are turned on when OFF timer is set.
Float
Water level is detected. (
Page 14)
98
→ →
No light
(Timer is cancelled)
No light
(Operation is stopped)
→ →
Air for front direction Air for upper direction When the operation is stopped.
HOW TO OPERATE
ABOUT DEHUMIDIFYING /
Insert the power plug into an outlet.
Hear beep sound three times. This is Standby Mode.
Press the POWER Switch.
The POWER lamp is turned on and operation is started.
Choose the desired operation mode.
The operation mode can be switched by pressing the
HUMIDITY Switch.
Every time the switch is pressed, the operation is
changed in this sequence:
,。
,。
,。
,。
PROHIBITED
Do not close the louver and operate the dehumidifier.
If FULL WATER lamp is turned on the operation panel when plugged in, empty water in the water receptacle
and reattach the receptacle.
When the water receptacle is full or removed from the dehumidifier, the operation stops automatically and FULL WATER
lamp is turned on. In this situation, the setting time is counted continuously.
During the operation, when the POWER Switch is pressed or the dehumidifier is unplugged, OFF timer is cancelled.
When the OFF timer is set, the setting time moves forward even while the FULL WATER lamp is turned on. If the setting
time comes and operation is stopped, the FULL WATER lamp is turned off as well.
,,。,
,,,。
,,。
,。
ABOUT OFF TIMER OPERATION /
Press the TIMER Switch.
TIMER lamp is turned on and OFF timer is set.
Every time the switch is pressed, the TIMER lamp and
setting time are changed in this sequence. When the
TIMER lamp is turned off, OFF timer is cancelled.
The TIMER lamp and OFF timer are changed in this
sequence according to the setting time left.
The setting time can be changed after setting the OFF
Timer. To change the setting time, press the TIMER
Switch.
OFF TIMER can be set in any operation.
,。
。,
,。
,。
Open the louver up.
The direction of louver can be adjusted in 2 ways.
When you want to change the air direction, adjust the louver.
Do not close the louver during the operation. It may lower
the efficiency of dehumidifying or stop the operation in high
temperature and humidity.
When you want to stop the operation, press the
POWER switch. The POWER lamp is turned off and
operation is stopped.
,。
,。
<40%, 50% and 60%>
The target indoor humidity can be set. When indoor
humidity is below the set humidity, the dehumidfying
operation is stopped. (motor fan is just operated). When
indoor humidity is above the set humidity, dehumidify-
ing operation is restarted.
<Continuous dehumidifying mode>
The dehumidifying is operated continuously regardless
of indoor humidity.
,,。
,。
During the operation, OFF timer can be set. When the set time comes, the dehumidifier is turned off automatically.
。,。
1110
HOW TO OPERATE (CONTINUED)
The operation is same as before the receptacle is full.
The compressor will stop during defrosting and the noise may vary. This change is due to the automatic defrosting operation
to defrost the inside of the unit, and it is not a malfunction. Please wait for a while.
,。
,。
ABOUT DEFROSTING /
When room temperature is low, frost may be generated inside the dehumidifier. In that case, DEFROST
lamp is turned on and the dehumidifier automatically starts to defrost.
During the defrost operation, dehumidifying is stopped and motor fan is just operated.
When the defrost operation is finished, the DEFROST lamp is turned off and dehumidifying is restarted.
,。,,。
,,。
,,。
If any abnormality occurs in the dehumidifier, the operation is
stopped and each lamp blinks.
The abnormal status is as the right table.
If the abnormalities occur, immediately turn off the dehumidifier
and consult your dealer.
ABOUT FULL WATER /
HOW TO DRAIN WATER IN THE WATER RECEPTACLE /
When the water receptacle is full or removed from the dehumidifier, the operation stops automatically
and FULL WATER lamp is turned on, hear beep sound 10 times.
When the receptacle is re-installed after the water is drained again, the operation automatically starts and
FULL WATER lamp is turned off. The operation is same as before the receptacle is full.
ABOUT ABNORMAL CONDITIONS /
HOW TO MOVE DEHUMIDIFIER /
Blinking lamp /
Object part/
POWER lamp /
Defrost sensor /
Temperature-humidity sensor /
Temperature-humidity sensor /
Radiator /
Continuous
dehumidifying lamp
/
DEFROST lamp /
All lamps /
Make sure to attach the lid of water receptacle correctly. Dehumidified water may not flow to the
water receptacle without the lid. If the lid is not attached correctly, water may spill and wet the floor.
If the water receptacle is not attached correctly, the dehumidifier does not operate.
Drain water in the water receptacle regularly. If water remains in the water receptacle, odor may be generated.
Holding the dehumidifier with one hand, hold
the handle of water receptacle then slowly
pull the water receptacle toward the front
with another hand so water does not spill.
Remove the lid of water receptacle by
pulling it upward.
Tilt the water receptacle to drain water.
Reattach the lid of water receptacle. Holding
the dehumidifier with one hand, hold the
handle of water receptacle with another hand
then reattach the water receptacle.
CAUTIONCAUTION
Lift the handle up. Hold the handle and lift the dehumidifier to move.
Before the dehumidifier is moved, stop the operation, pull out the power cord, dr
ain water in the
water receptacle, and re
install the water receptacle. If the dehumidifier is moved with the container
full of water, water comes out of the water receptacle, and it may wet the floor.
If the dehumidifier tilts or moves, it may damage the floor. Also, water in the dehumidifier may spill
and wet the floor.
。,
WARNING
WARNING
EFFICIENT USE OF DEHUMIDIFIER
DEHUMIDIFYING ROOM:
Open and close windows and doors of
room no more often than necessary:
If external air enters the room, the dehumidify-
cation effect will be reduced.
ADDITIONAL DRYING OF CLOTHES:
U
se a dressing room beside bathroom,
etc. to operate the dehumidifier so
that air is blown onto clothes.
The smaller the room space, the faster drying
will finish. Fully squeeze dry laundry so that
no water droplet will fall on the dehumidifier.
At low temperature(lower than approx.20°C),
the laundry will be hard to dry out.
12 13
Rear >30cm
Float
Water receptacle
Side >30cm
Cloth
Cotton bud
Lever
Cover of drain outlet
Upside >50cm
HAVE SOME SPACE AROUND THE
DEHUMIDIFIER:
If the air outlet and the inlet opening
are blocked, it may cause malfunc-
tions because of overloading.
Have some space between the dehu-
midifier and two walls behind it, as
shown in the figure. Have open
spaces on the other sides.
Make sure that no water or foreign
object is in the float:
Do not run dehumidifier with water or
foreign material inside the float.
If water is left in the float after cleaning the
water receptacle with water, automatic stop
device to stop operation when the water is
full may not work properly. Wipe off the
water in the float completely. Never put any
foreign material in the float.
Be sure to clean the drain outlet and
hole of water receptacle lid at least
once every half a year.
Drain outlet
Remove the water receptacle.
,。
。,
,。
Lid of the water receptacle
Remove the water receptacle. Drained water
flows from the circled part to water
receptacle and it may get dirty.
Remove the lid and clean the circled part
with cloth.
Replace the lid and insert the water
receptacle.
ADDITIONAL CAUTIONS
MAINTENANCE AND INSPECTION
CLEANING AIR FILTER
If dust accumulates on the air filter, it will not
only take much more time than usual to lower
the humidity, but also cause a fault. Clean the
filter once every two weeks by the following
procedure:
Do not wash the air filter with hot water over 40°C
When drying the filter, do not expose it to direct sunlight, to prevent shrinkage.
After cleaning the air filter, do not forget to insert it.
If the dehumidifier is operated without the filter, dust will accumulate inside it, causing a fault.
Remove the air filter.
Dirt in the air filter can be washed out with
water or removed with a vacuum cleaner. If
it is washed with water, dry it in the shade.
Reattach the air filter to the main unit.
Clean the dehumidifier periodically to ensure long, trouble-free use.
Before cleaning, be sure to turn off the dehumidifier and unplug the power cord from the AC outlet.
CAUTION
CAUTION
Replace the cover and insert the water
receptacle.
Move the cover of drain outlet by
pushing the lever then clean the drain
outlet with object such as cotton bud.
14 15
Float
Water receptacle
Clean with soft
cloth
moistened with
clean water.
Completely wipe off all water from the float: If water
remains in the float, the auto stop mechanism may not
work normally when full water level is detected.
Water splashed on the dehumidifier will degrade insulation or cause rust.
Use a cloth tightly wrung out when cleaning the operation block (operation switch, etc.).
Do not use the following when cleaning. Using such an object will damage the plastic parts.
Thinner, benzene, alcohol, oil, soap powder, polishing powder, alkaline detergent, boiling water, acid
detergent, scrubbing brush.
When using chemical dust cloth, follow the instructions.
CLEANING EXTERIOR
CLEANING EXTERIOR
CLEANING WATER RECEPTACLE
CLEANING WATER RECEPTACLE
Use soft cloth moistened with lukewarm water or neutral
detergent to clean the case of dehumidifier.
After cleaning with neutral detergent, be sure to wipe
it off using cloth moistened with clean water.
Use dry cloth to wipe off any water drops from the case.
The water receptacle is a critical component in the dehumidifier: Full water level in it, and its presence or absence, will
always be detected.
Handle the receptacle with care so that it is not bent out of shape: If it is deformed, the dehumidifier may not work.
Use water to wash the float and water receptacle.
,。,。
CAUTION
CAUTION
PERIODIC CHECKS
Does power plug generate abnormal heat?
Is there any crack or scratch on power cord?
Is air filter torn or otherwise damaged?
Check the following once every half year to one year to
secure safe use. If you have any doubts, immediately
consult your dealer.
If the supply cord is damaged, it must be replaced by
the manufacturer or its service agent or a similarly
qualified person in order to avoid a hazard.
MAINTENANCE AND INSPECTION (CONTINUED)
Unplug the power cord from the AC outlet.
Dispose of all water in the receptacle.
Clean the air filter.
Dry the dehumidifier in a well-ventilated place which is
not exposed to direct sunlight for half a day.
Then cover
the dehumidifier with a vinyl bag and store it in the
upright state.
STORING DEHUMIDIFIER
If you do not use the dehumidifier for a long period of time, store it after performing the following procedure:
1716
Phenomena / Checking points /
Before calling service, check the following items.
Do not allow anyone other than qualified service personnel to repair the dehumidifier.
WHEN REQUIRING REPAIR SERVICE
The dehumidifier can
not be operated even if
the POWER Switch is
turned on.
The water receptacle is not installed correctly.
The dehumidifier is defrosting (DEFROST
lamp is turned on). (Refer page 12 for
details)
The power plug is not inserted securely into
the power outlet.
The breaker or fuse blown.
Power failure occur.
The water receptacle is full of water.
The air filter is clogged with dust.
Room temperature /humidity is low. (Refer
page 7 for details.)
The air suction port or air outlet is blocked.
Doors or windows has been opened
frequently.
There is a device which generates steam,
such as oil stove, etc.
Room is too large.
The floor is not steady.
The dehumidifier is not installed correctly
and is unstable.
If noise is heard from water receptacle,
remove it once, and then reinsert it securely.
Dry air does not strike washing.
Amount of washing is too much.
Room temperature is 20
°C
or less.
Room is too large.
Dehumidifying cannot
be done sufficiently.
Humidity not reduced
properly.
Noisy sound is heard.
Drying of washing is
slow.
19
18
If the following phenomena occur, immediately
consult your dealer.
If the following phenomena occur, immediately
turn off the dehumidifier and consult your
dealer.
When breaker and fuse blow frequently.
When foreign object or water enters the dehumidifier.
When power plug or power cord is abnormally hot.
Phenomena /
Checking points /
Checking points /
Clothes do not dry soon.
The following are not defects of the dehumidifier.
1 When the dehumidifier starts to operate, the
room air may smell dustly for a while.
Because the moisture comes out of the walls
and other parts of the room. This is not a
smell from the dehumidifier.
2 When the humidity is very high, condensed
water may adhere to the water receptacle.
This occurs due to cold water from
dehumidifying and is not a problem.
3 Some time, sound like water flowing is
heard. This is the sound that refrigerant flow
in the refrigerator.
The following do not indicate a fault:
After the dehumidifier is operated, the room smells moldy
for a while. This odor is caused by moisture derived from
wall, etc., and does not originate from dehumidifier.
If the humidity is too high, moisture may condense on the
water receptacle. This is because the dehumidified water is
cold, and does not indicate a fault.
A sound like water flowing is heard occasionally. The sound
is heard when refrigerant flows inside the dehumidifier.
If the dehumidifier remains defective after checking the
above and performing due corrective action, immediately
unplug and consult your dealer.
2120
OPTIONAL (SOLD SEPARATELY) ACCESSORIES
The following optional accessories are available. Order and purchase from your dealer.
Drain hose
(Service parts No: RD-110EX 024)
Drain hose for continuous drainage: Use this to drain
dehumidified water.
Air filter
(Service parts No: RD-110EX 001)
The standard effective lift of the air cleaning filter is about
1 year.
SPECIFICATIONS
Accessories
RD-110EX
Type
Quantity of
Dehumidified Water
11.5L/D (when the room air temp. is 30
°C
and the relative hum. 80%)
6.0L/D (when the room air temp. is 26.7
°C
and the relative hum. 60%)
Instruction manual.......1
.............
Outer Dimensions
Rated Voltage
Rated Frequency
Consumption Power
Length of Power Cord
Weight
478 mm (Height) x 290 mm (Width) x 190 mm (Depth)
Specification may be changed partially for improvement of the product.
This dehumidifier is provided with auto defroster.
220 V
50 Hz
190 W
1,790 mm
9.6 kg
Drain hose opening
DRAINING DEHUMIDIFIED WATER CONTINUOUSLY /
For continuous drainage, inquire at the
dealer about a drain hose (sold separately;
refer to “Optional Accessories” on page 20).
CAUTIONS IN THE USE OF THE DEHUMIDIFIER IN CONTINUOUS DRAINAGE
For the use of the dehumidifier in continuous drainage, inspect the filters for dirt, the clogging in the drain outlet, and so
on, once very two weeks, and confirm that there is no malfunction.
I
nstall the drain hose to slope downward. Make sure that water runs in the hose during the trial operation.
When installing the drain hose, avoid the end of the hose from going in water or causing winding hose.
Do not perform continuous drainage in an environment where the ambient temperature of drain hose
drops below freezing point.
If there is a difference in temperature between water in drain hose and ambient temperature, moisture
may condense on the surface of hose. Depending on the environment where the dehumidifier is being
used, use generally available insulation material to insulate the hose.
When stopping continuous drainage /
Remove the drain hose.
CAUTION
Insert the drain hose into the drain outlet.
When using a drain hose, put it on flat floor
and do not hold it. Otherwise water may not
flow out smoothly.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Hitachi RD-110EX ユーザーマニュアル

カテゴリー
除湿機
タイプ
ユーザーマニュアル

他の言語で