3.2 OPERATION METHOD
8
EN
In standby state, press the Timer key to set ON time. Press Up and Down keys to set
ON time (1~24H), and the timer indicator lamp lightsup.
Dehumidification mode
Timer mode
When the A/C enters cooling mode automatically or cooling mode is selected after
power ON, the cooling indicator lamp lights up.
Press Speed key to choose High/Mid/Low speed.
Fan mode
When pressing mode key or choosing Fan mode by pressing the remote controller,
the wind indicator lamp lights up.
Press Speed key to choose High/Mid/Low speed.
Temperature can’t be set.
Press Up/Down key to adjust setting temperature (16~30).
In ON state, pressure the timer key to set OFF time. Press Up and Down keys to set
OFF time (1~24H), and the timer indicator lamp lights up.
When pressing mode key or choosing dehumidification
mode by pressing the remote, the dehumidification
indicator lamp lights up.
Remove the dehumidification water wedge, insert water
manifold, place the other end of the water manifold
into the water vessel or drainage passage, as shown in
the right figure.
After entering the dehumidification mode, if room
tempearture≥17℃ (62℉) , the compressor is ON. Then
control as follows: when room temperature ≤15℃( 59℉)
the compressor is OFF; when temperature increases to room temperature≥17℃,
the compressor is started again (in order to protect the compressor, it will be
restarted 3min.later).
In dehumidification mode, the fan is defaulted to run at low speed, and wind speed
can’t be adjusted.
Temperature can’t be set. ( Note: when use dehumidify function, should remove
exit pipe components, otherwise, it will cause worse dehumidify performance
and appear “FL” water full alarm)