Inspur DP1000G5 ユーザーマニュアル

タイプ
ユーザーマニュアル
The cabinet, chassis or guide rails may cause scratches, please be careful.
机柜或者服务器机箱、导轨可能造成划伤
When installing new servers into the rack in use, please be aware of electric shock.
在正在使用的机柜中安装新服务器时,请谨防触电
上架安装指南
V1.0
请注意!
Installation Guide
Warnings!
When installing 2U or bigger models, 2 people are needed at least.
安装2U或更大的机型时,至少需要2个人
During installation process, please don’t block the vents on the server, especially the vents
on the front and rear end of the server.
安装时请注意不要阻塞服务器上的通风孔,尤其是服务器前、后部的通风孔
Please remove the protective film on the server surface before using.
请在使用之前将服务器壳上的保护膜撕去
Please leave 15cm minimum of clearance on the front and rear sides of the server for proper
ventilation.
服务器的前、后部需至留出15厘米空间,以便于系统散热
Please install air baffles for the position without device installed, to make sure that the server
can get enough air flow, and to avoid air turbulence in the server room.
没有安装设备的机柜位,请始终安装挡风盲板,以确保服务器获足够的气,并避免机房气
紊乱
Servers are high-power electrical appliances, and they should be installed into the dedicated
cabinets with vents or professional water-cooled cabinets, to prevent system failures caused
by overheating.
服务器是高功耗电器,能安装在带有通风孔的专用机柜,或者专水冷机柜,以免过热造成
统失效
If it needs to install more than one devices, please load from the bottom up, and load the
heaviest items first.
如果要安装多台设备,先从机柜靠下的空位开始,并将较重的设安装在机下部
Please note the cabinets bearing capacity, power supply capacity and heat dissipation
capacity, be sure not to install devices beyond the cabinet’s bearing capacity.
请注意机柜的承重、供及散热能力,切勿安装超出机柜承载能力设备
For the convenience of using the front and rear ports of the server and cabling, leave 70mm
minimum of clearance between the front end of the server and the inner side of the cabinets
front door, and leave 150mm minimum of clearance between the rear end of the server and
the inner side of the cabinets rear door.
为了便于使用服务器前后部的接口,并便于布线,服务器前部与柜前门内之间至少留出70
毫米、后部与机柜后门内侧之间至少留出150毫米距离
If the device is more than 15kg, 2 people are needed at least.
安装超过15千克的设备时,至少需2个人
If the device is more than 30kg, 3 people are needed at least.
安装超过30千克的设备时,至少需3个人
If the device is more than 50kg, 4 people are needed at least.
安装超过50千克的设备时,至少需4个人
.
.
Please keep this document for checking in the future.
请保留本文档,以便于日后查阅
15kg
30kg
50kg
上架安装指南 V1.0
上架所需部件
安装导轨
1
1
3
2
2
4
3
5
4
Align the rail stand off on each side of the system and lower them into the slots on
the rail. Put the system downward until all the rail standoffs are seated in the
slots.
抬起服务器将其两侧各三个铆钉与导轨同一侧的三个铆钉槽位对齐,然后把服务器
向后倾斜 5°左右,将服务器后、中、前铆钉依次卡到导轨的铆钉槽位中。
Press the side-release lock buttons on both
rails and slide the system into the rack.
按压图中 所示的导轨两侧卡扣,将服务
器按照图中 箭头所示的方向推入机柜。
6
Locate and tighten the screws
under each handle on the system.
服务器推入机柜后,将服务器左右
把手的螺丝固定牢固。
Identifying the Rail Kit Contents
Rail Kit is assembled by inner rail, middle rail and outer rail.
导轨由内轨,中轨和外轨组成。
Installing Rails
卸除导轨
Removing Rails
Position the rear bracket and align each pins with the rack holes. Pull the latch
release button on the rear bracket. Push the rail into the rack until the square
pins or round pins fully seat on the rack holes and the latch clicks into place.
在机柜上确定好导轨后支架的安装位置,将导轨后支架上的方形锁扣和圆形按钮
对准机柜角轨上的孔位,参照图中 按压后托卡勾,再依图中 箭头所示方向推
导轨,直到方形锁扣完全卡入角轨孔位。
Pull up the latch release part on the front bracket Push the rail into the rack
until the square pins fully seat on the rack holes and the latch clicks into place.
将前固定件的释放件参照图中 箭头拉开,再依图 箭头将导轨推入,直到方形
锁扣完全卡入角轨孔位。
Notice: Keep the front and rear bracket on the same level.
注意:一定要保持导轨的前后固定箭处于同一水平线。
Repeat 1 and 2 steps to install the other side. And pull the inner rails out of the
rack until they lock into place.
重复1和2步骤完成另一侧导轨的安装。然后按照图中箭头所示的方向将内轨完全
打开。
Notice: Keep the left and right rail on the same level.
注意:务必保证两侧导轨在同一水平线。
Remove the screws from left and right handle on the system.
将服务器左右把手的螺丝卸除。
Pull out the system and press the side-release lock buttons on both rails, and lift
the system up and away from rails.
依图中 箭头所示将服务器拉出。拉压图中 所示的导轨两侧卡扣,将服务器向上
倾斜 左右,将服务器前、中、后铆钉依次抬出导轨的铆钉槽位。
Press the side-release lock buttons on both rails and slide the rails
into the rack.
按压图中 将内、中轨依箭头方向收回。
Removing the rails as the same steps with installing.
依组装步骤拆卸导轨。
Installation Guide
outerrail
Middlerail
Innerrail
Rearbracket
Frontbracket
  • Page 1 1
  • Page 2 2

Inspur DP1000G5 ユーザーマニュアル

タイプ
ユーザーマニュアル

他の言語で