OPTEX FA D2SA-SN ユーザーマニュアル

タイプ
ユーザーマニュアル

このマニュアルも適しています

Digital Amplifier Detachable Photoelectronic Sensor
DS Series
* Thank you for purchasing the DS Series. We hope you are fully satisfied with this product and enjoy
its performance.
* Carefully read this instruction manual and keep it for future reference.
Instruction Manual
Safety Precautions
Accessories and others
Precautions for using laser Specifications DIMENSIONAL DRAWING
Operating Precautions
Carefully read and understand the safety precautions before operation.
The important information is provided to protect your health and property.
Do not apply any other installing or operating procedure other than that described in
this manual.
Confirmation of laser emission is available with the laser emission warning light.
It starts lighting after turning the power on and keeps lighting while the laser is being
radiated. It is also possible to confirm with the exclusive amplifier unit.
When exporting this machine to the US, the US laser control, FDA (Food and Drug
Administration) is applied. This product has been already reported to CDRH (Center
for Devices and Radiological Health). For details, contact our Customer Service.
When using DSTA-200 or DSTA-200-M8 for length measurement, follow the
instructions below.
Precautions in using DSTA-200 / DSTA-200-M8
Installing the attachment to DSR-800DSR-5000 allows two types of beam shape: Line
beam and area beam. Attach the beam-shape lens and the optical axis to use together.
* The beam form may depend on the individual products.
* Do not use for DSD-100. Uninstallable to DSTA-200, DSTA-200-M8, nor DSTA-S.
Instruction for use
1. When cleaning, blow off or lightly wipe with a soft cloth.
Do not use thinner, benzene or kerosene.
2. Avoid strong push of the reflecting surface or direct impact.
Doing so may result in damaging the prism and deteriorating the performance.
3. Avoid using outside or under the environment where oil or water scatters.
Installation procedure
Refer to the figure below and use in the correct direction.
Improper installation may cause malfunction.
MP-45 Reflector (attached to DSR-800DSR-5000)
Indicates a possible hazard that may result in
personal injury or property damage if the product is
used without observing the stated instructions.
Indicates a possible hazard that may result in
death, serious injury, or serious property damage
if the product is used without observing the stated
instructions.
This product cannot be used as a safety device to
protect human body.
Emitter is applied to gray cable and Receiver is applied to black one.
Install the sensor so that the sensor of flood beam is positioned in the center of the
light receiving part. (Install so that the indication value of amplifier unit is
maximum.)
Install the flooding/receiving device in the same direction.
Refer to each label or indicator light as a standard.
* 1 DSD-100 : With white paper (90 %) of 200 x 200 mm
DSR-800 : With the reflector MP-45 (accessory)
DSR-5000 : With the reflector P250F (accessory)
* 2 Defined with center strength 1/e2 (13.5%). There may be leak light other than the specified spot size. The sensor
may be damaged when there is a highly reflective object around the targets
* 3 Right angle to sensing axis.(to 2m)
* 4 The weights of DSTC-200 and DSTA-200 include the emitter and the ditector.
Mandatory Requirements
Line beam
Area beam
Approx. 40 x 1 mm
(Distance: 300 mm)
Approx. 35 x 35 mm
(Distance: 300 mm)
Beam shape
• DSTA-200 DSR-800
DSR-5000
DSD-100
DSTC-200
DSTA-200-M8
MP-45
DSTC-200-M8
P250F
2- 3.2
16.1
21.
34.6
13.4
13
6
34.6
28.1
6.5
2.8 20.9
26.5
18.6 (Optical center)
10.6
11.2
18.5
6
16.1
12.35
19.1 12.7
3 4 core cable Standard length 0.15m (Black) Tip: M8 Plug
3 2 core cable Standard length 0.15m (Ash) Tip: M8 Plug
3 4core cable Standard length 2m (Black) Tip: M8 Jack
3 2core cable Standard length 2m (Ash) Tip: M8 Jack
2
3
4
1
R2.6
R2.6
2- 3.2
2
0.2
4.5
23
7.4
7.4
29
14.5
44.8
23
37
2-R3.7
4-R1.2
2- 3.2
4-C3
FDA warning /
Laser open label (2)(3)
Certification label (1)
FDA warning / Laser open
/ Certification label (4)
Indicator light
Indicator light
Indicator light
Line beam lens
Area beam lens
( 1 )
( 2 )
( 3 )
( 4 )
(DSR-800/DSR-5000
DSD-100/DSTC-D
DSTC-S) (DSTA-D/DSTA-S)
(unit : mm)
Head office:
Mitsui Seimei Kyoto Yamashina BLDG 6F, 46-1
Takehanadounomae-cho, Yamashina-ku, Kyoto
607-8085 Japan
TEL: +81-(0)75-594-8123
FAX: +81-(0)75-594-8124
13
13.4
2- 3.2
2.7
52.9
36.6
31.65
Laser emission indicator light Output indicator light
10.6
23.5 (Optical center)
16.1
6
37.4
9.9
12.35
18.5
8.2
34
46.4
52.9
25.9
47
41.4
3 2 core cable Standard length 2m (Ash)
3 4 core cable Standard length 2m (Black)
2-R2.6
2- 3.2
Mounting hole
2.8
2
3
4
1
23.5 (Optical center)
9.9
37.4
6
16.1
31.65
36.6
52.9 2.7
13.4
13
10.6
Output indicator light
Laser emission indicator light
2- 3.2
3 4 core cable Standard length 0.15m (Black) Tip: M8 Plug
3 2 core cable Standard length 0.15m (Ash) Tip: M8 Plug
2- 3.2
2.8 41.4
47
34
8.2
25.9
52.9
46.4
2-R2.6
6
18.5
12.35
1
4
3
2
3 4core cable Standard length 2m (Black) Tip: M8 Jack
3 2core cable Standard length 2m (Ash) Tip: M8 Jack
Meanings of Safety Symbols
WARNING
CAUTION
WARNING
CAUTION
This product is not an explosion-proof construction. Do
not use the product under flammable, explosive gas or
liquid environment.
Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous
radiation exposure.
The light source of this product applies the visible light
semiconductor laser.
Do not disassemble or modify the product since it is not
designed to automatically stop the laser emission when
open. Disassembling or modifying at customer's end may
cause personal injury, fire or electric shock.
Do not stare into the laser beam directly, install at eye-
level of the people around, nor expose the beam to the
human body intentionally.
Use the exclusive amplifier unit to connect the product.
Not doing so may result in an accident or product damage.
Wiring or disconnecting with the power ON is danger.
Never fail to turn OFF the power supply.
Installing in the following places may result in malfunction:
1. A dusty or steamy place
2. A place generating corrosive gas
3. A place directly receiving scattering water or oil
4. A place suffered from heavy vibration or impact
Do not use the sensor outside nor expose the detection
surfacedirectly to ambient light (laser light, incandescent
light and sunlight).
Do not use the sensor in transient state after power on
approx. 100 ms).
The sensor performance may depend on the individual
units.
Wipe off dirt on the emitting/receiving parts to maintain
correct detection. Also, avoid direct impact on the
product.
Laser emission warning light
Laser label
Japan
Other countries (except US)
US
Lens attachment (Model BL-W130L-1:Optional)
Website http://www.optex-fa.com
Laser Type Sensor Head DSR -800 DSTC-200-M8
DSR -5000 DSTA-200-M8
DSD -100
DSTC-200
DSTA-200
This product is classified as a Class 2 (II) Laser Product by JIS C6802 / IEC / FDA Laser
Safety Standard as this radiates the visible laser beam. The warning label and the
description label in English are attached on the side face of the sensor head indicating the
CLASS 2/Class II.
*
The emitters DSTC-D/DSTA-
D and DSTC-S/DSTA-S of DST-200/M8 and DSTA-200/-M8 are rated
as Class II by the FDA standard (when exportin
g to the US). However, the class 1 is applied for the
JIS/IEC standard.
Exchange the label enclosed with the product.
Mounting hole
Mounting hole
Mounting hole
0536692
Laser radiation warning light
(Green)
(DSTA-D/DSTA-S)
(DSR-800/DSR-5000
DSD-100/DSTC-D
DSTC-S)
The product specification may change without notice for improvement.
For any inquiry, please contact the manufacture/vendor below.
Retro
reflection type
Diffuse
reflection type
Through beam
type
Model
Through beam/
Length measurement type
800
DSR
-
5000
DSD-100
DSTC-200 DSTA-200
DSA-M /DSA-M -M8 / DSA-S
Adaptable amplifier unit
Visible light semiconductor laser 650nmLight source
Emitter: DSTC-D Emitter: DSTA-D
Cable
Detector: DSTC-200 Detector: DSTA-200
-
-DSTC-200-M8
DSTA-200-M8
M8 Relay-type
- - DSTC-S DSTA-S
Emitter M8
- - DSTC-R DSTA-R
Detector M8
Standard
Fast
Long
CLASS 2IEC/JIS CLASS CLASS 1
max. 3mWOutput max. 390 W
Class IIFDA CLASS
8 m
1 m
2 m
5 m
0.7 m
2 m
Length measurement mode: 0.5 m
2 m
0.550 m
0.335 m
0.120 m
0.25 m
(Only Long and Standard)
Approx. 2 mm
Beam size   
 
*2 Approx. 1 mm Approx. 2 mm
Approx. 30 x 2.5 mm
45g 90g 115g
(Distance: 2 m) (Distance: 1 m) (Distance: 2 m) (Distance: 2 m)
0.2 mm 0.2 mm 0.2 mm 0.3 mm
Laser radiation indictor light: Green Output indicator light: OrangeIndicator light
Repeat accuracy *3
-10 to +55°C/35 to 85 %RH (No condensation or freezing)
Operating temperature/humidity
-25 to +70°C/35 to 85 %RH (No condensation or freezing)
Store temperature/humidity
3,000 lx (Incandescent light) 10,000 lx (Sunlight)Ambient light
10 to 55 Hz Double-amplitude 1.5 mm 2 hours at each direction of X, Y and Z
Shock resistance
IP67
Protection category
PC (Case, Cover) PMMA / Glass (Front glass)Material
Weight (including the codes)*4
Detection
distance
*1
13
13.4
34.6
21.
16.1
Output indicator light
Laser emission indicator light
Output indicator light
Laser emission indicator light
2- 3.2
16.1
6
11.2
10.6
18.6 (Optical center)
R2.6
R2.6
2- 3.2
12.719.1
12.35
18.5
26.5
20.9
2.8
28.1
34.6
3 4 core cable Standard length 2m (Black)
DSTC : 3 2 core cable Standard length 2m (Ash)
DSR/DSD : 3 4 core cable Standard length 2m
1
4
3
2
6.5
ヘッド取説.indd 1 2006/01/24 14:32:55
CAUTION
WARNING
Digital Amplifier Detachable Photoelectronic Sensor
D2SA Series
Laser Type Amplifier Unit D2SA-M D2SA-M 3
D2SA-S D2SA-S 1
D2SA-M -M8 D2SA-S -M8
Instruction Manual
Safety Precautions
Operational Precautions
Carefully read and understand the safety precautions before operation.
The important information is provided to protect your health and property.
Do not apply any other installing or operating procedure other than that described in
this manual.
Meaning of Safety Symbols
Indicates a possible hazard that may result in
personal injury or property damage if the product is
used without observing the stated instructions.
Indicates a possible hazard that may result in death,
serious injury, or serious property damage if the
product is used without observing the stated
instructions.
This product is not an explosion-proof construction.
Do not use the product under flammable, explosive gas
or liquid environment.
Do not use the product in water.
Do not disassemble, repair, or convert the product.
Failure to do this may cause failure, fire, or electric
shock.
Operate within the rated range.
This product cannot be used as a safety device to
protect human body.
Mandatory Requirements
Specification Each Part
Adjustment
Input/Output Schematic
NPN PNP
D2SA-MN / DSA-SN D2SA-MP / D2SA-SP
D2SA-MN-M8 / D2SA-SN-M8 D2SA-MP-M8 / D2SA-SP-M8
D2SA-MN3 / DSA-SN1 D2SA-MP3 / D2SA-SP1
Auto Teaching
Zone Teaching
Two Points Teaching Teaching Transparent Object
Teaching Length Measurement
SET
R
UN
Switch to SET.
SET
R
UN
Switch to RUN.
Select the one-point teaching.
Press the teaching button.
T
The threshold flashes and the
display returns to normal.
Transmission Type (In length
measurement)
SET: Press the teaching button when
there is no object with the flood light
and the light receiver facing each
other.
IN: Press the teaching button when
there is an object.
Reflection, Transmission, Regressive
Reflection Type
Start and End: Perform adjustment
while the object is passing.
Reflection type: Perform adjustment
with the background without object,
and when there is an object.
Set the zone (detection range) to ±10 %
against the amount of received light.
Set the threshold at the center between
the 1st and the 2nd points.
2nd: Perform adjustment with the
background without object.
Reflection type
1st: Perform adjustment when there is
an object.
Rotating reflection type: Perform when
there is no object.
SET
R
UN
Switch to SET.
SET
R
UN
Switch to RUN.
Select the one point teaching.
Press the teaching button.
T
The threshold flashes and the
display returns to normal.
SET
R
UN
Switch to SET.
SET
R
UN
Switch to RUN.
Select the auto teaching.
End: Press the teaching button.
Start: Press the teaching button.
The threshold flashes and the
display returns to normal.
Base unit Handset Base unit
Model
Handset
D2SA-M(N/P)
D2SA-S(N/P)
D2SA-M(N/P)3 D2SA-S(N/P)1
DS Series
Adaptable sensor head
12 - 24 V DC ± 10 % including a ripple
Power source, voltage
Cable type
-
-
D2SA-M(N/P)-M8 D2SA-S(N/P)-M8
M8 connector type
60µs/500µs/2ms (Fast/Standard/Long)Response time
45 mA or less / 24 VConsumption current
Load current: 100 mA or less Residual voltage:1.8 V or less
Control output
Laser emission indicator light: Green, Output Indicator light: Orange (1·2CH)
Teaching indicator light: Red Channel indicator light: Green (1·2CH)
7 segment 8 digit display
Digital display
Timer function
10 to 55 Hz Double amplitude 1.5 mm 2 hours for each direction of X, Y, and Z
OFF, On delay, Off delay, One-shot
1 ms - 9 sTimer time
Yes: Up to 4 machines
Mutual interference
prevention function
Light on / Dark on Switching type in the function
Output method
Current output:4 - 20 mA -Analog output
External input setting
(teaching, synchronizing input,
floodlight off, counter reset)
Output setting
(
2CH output + Alarm output
)
External input setting
(teaching, synchronizing input,
floodlight off, counter reset)
Setting input/output
-25 to +55°C / 35 to 85 % RH (No freezing)
Operating temperature/humidity *1
-40 to +70°C / 35 to 85 % RH (No condensation)
Store temperature/humidity
IP50Protective category
Shock resistance
Indicator light
*1 Operating temperature may differ according to the number of connection.
See as follows:
1 - 3 machine(s): -25 to +55°C
4 - 8 machines: -25 to +50°C * When not using analog output.
* Base units and handsets of the advanced or standard models can be connected with any
combination.
However, some combination may be restricted. For details, contact our Customer
Service.
Advanced Model (2CH) Standard Model (1CH)
PC: Case and coverMaterial
Cable type: 65 g M8 connector type: 30 g
Weight (including the codes)
NPN / PNP Open collector
* Settable only with D2SA-M -M8
Pin layout
D2SA-M -M8
DSA-S -M8
1
24
3
External input
12 to 24 V DC
Control output
0 V
Setting Maximum Sensitivity
One Point Teaching
Transmission type
Regressive Reflection type: Perform
adjustment when there is an object.
Reflection type: Perform adjustment
when there is no object.
Reflection type: Perform adjustment
with the background without object.
Set the threshold to + % against the amount
of received light.
(Depends on the response speed setting.)
Threshold
Threshold
Upper limit
Lower limit
10%
10%
Zone
Near
Far
Valid only when the length measurement function is set. Allows to
determine the size or the length of object.
* Not displayed on the teaching mode menu unless the application of length
measurement is selected in the detection mode setting.
* Teaching length measurement or length measurement mode does not measure the
actual length of object accurately.
Manual Adjustment
Pressing the UP/DOWN button in the RUN mode flashes the threshold. It
indicates that adjustment is possible. Adjust to any value using the
UP/DOWN button.
When using the zone teaching, the threshold of upper/lower limit can be set
individually.
The available teaching depends on "5.3 Detection Mode setting." Refer to
below:
Error Display in Teaching
An error message is displayed in the event of error during adjustment.
Refer to the table below for readjustment.
* No operation state for 5 seconds during setting automatically returns the display to
normal as well.
SET
R
UN
Switch to SET.
SET
R
UN
Switch to RUN.
Select the two points teaching.
2nd point: Press the teaching button.
T
1st point: Press the teaching button.
T
T
T
The threshold flashes and the
display returns to normal.
SET
UN
Switch to SET.
SET
R
UN
Switch to RUN.
IN: Press the teaching button.
SET: Press the teaching button.
T
T
The upper limit flashes and
the display returns to normal.
SET
R
UN
Switch to SET.
SET
R
UN
Switch to RUN.
Press the teaching button.
T
The threshold flashes and the
display returns to normal.
SET
R
UN
Switch to SET.
SET
R
UN
Switch to RUN.
Select the zone teaching.
Press the teaching button.
T
The threshold flashes and the
display returns to normal.
Normal
Automatically returns to
the normal display 5
seconds after completion of
the setting (no operation).
When using zone teaching
Setting Lower Limit (Far)
Automatically returns to the normal display 5
seconds after completion of the setting
(no operation).
Indicates shortage of light intensity or no difference
of light intensity.
Indicates a sampling error in teaching of a moving object.
Indicates a calculation error.
Indicates that the teaching is interrupted.
Setting Upper Limit (Near)
Thank you for purchasing DSA Series. We hope you are fully satisfied with this product and enjoy its
performance.
Carefully read this instruction manual and keep it for future reference.
WARNING
CAUTION Use the specified sensor head to connect this product.
Any use other than specified will cause accident or
product damage.
It is dangerous to wire or attach/remove the connector
with the power on. Make sure to turn off the power
before operation.
Make sure to use the product with the protective cover
attached and closed.
Installing in the following places may result in
malfunction:
1. A dusty or steamy place
2. A place generating corrosive gas
3. A place directly receiving scattering water or oil.
4. A place suffered from heavy vibration or impact.
The product is not designed for outdoor use.
Do not use the sensor in transient state after power on
(approx. 100 ms).
Do not wire with the high voltage cable or the power line.
Failure to do this will cause malfunction by induction or
damage.
The sensor performance or digital display values may depend
on the individual units or the condition of detected product.
* D2SA-S / D2SA-S 1 of the handset do not have power wires (brown, blue) as they receive the power
supply from the base unit.
NameNo. Function
Laser emission indicator light
Turns on while the amplifier is powered.
1 CH output indicator light
Turns on when the output of 1 CH is ON.
2 CH output indicator light
Turns on when the output of 2 CH is ON.
Main monitor (Red)
Displays light intensity, function, and the number of counts.
Sub monitor (Green)
Displays the threshold, function selection, and the number of counts.
Teaching mode indicator light
Turns on in the Teaching mode.
Valid channel indicator light
(1 CH)
Keeps turning ON when the monitor display value,
adjustment, and the function setting are valid to 1 CH.
Valid channel indicator light
(2 CH)
Keeps turning ON when the monitor display value,
adjustment, and the function setting are valid to 2 CH.
UP button RUN mode: Displays or changes the threshold.
DOWN button
Function mode: Selects the function or changes the numerical values.
Mode button RUN mode: Switches to the Function mode. (0.5 s
)
Function mode: Fix the selection.
Teaching button RUN mode: Switches the channel.
Function mode: Returns to RUN mode or performs scaling.
Set mode: Run the teaching.
SET/RUN selection switch
Switches between Teaching mode and RUN mode.
* The button function varies in each mode: RUN mode, Function mode, and SET mode.
* As D2SA-M 3/D2SA-S 1/D2SA-M -M8/D2SA-S -M8 are 1 output (1 CH) type,
and do not turn on.The channel switching of also becomes invalid.
Main circuit
Protective
circuit Protective
circuit
Load
Load
Black and
white
Gray
Blue
White
Black
Brown
Analog output
0 V
Analog GND
External
input
Control output
1 CH
12 to
24 V DC
Control output
2 CH
Main circuit
Protective
circuit Protective
circuit
Load
Load
Black and
white
Gray
Blue
White
Black
Brown
Analog output
0 V
Analog GND
External
input
Control output
1 CH
12 to
24 V DC
Control output
2 CH
Main circuit
Protective
circuit
Load
Gray
Blue
Black
Brown 12 to
24 V DC
Control output
1 CH
External
input
0 V
1
4
2
3
Main circuit
Protective
circuit
Load
12 to
24 V DC
Control output
1 CH
External
input
0 V
Gray
Blue
Black
Brown1
4
2
3
Main circuit
Protective
circuit
Load
12 to
24 V DC
Control output
1 CH
0 V
Brown 1
Black 4
Blue 3
Main circuit
Protective
circuit
Load
12 to
24 V DC
Control output
1 CH
0 V
Brown 1
Black 4
Blue 3
/
Long +1%
Stnd +5%
FaSt +15%Threshold
2nd
1st
Threshold
Set the threshold to -10 % against the
amount of received light.
-10%
Threshold
Reflection side
of reflector
(Standard detection) All teachings are valid.
(Edge detection) No teaching are valid.
(Differential detection) Only one point teaching is valid.
Function Setting Connecting Sensor Head
Dimensional drawing
Options
Setting Amplifier Unit
Switching Channel
Pressing the button during the RUN mode allows switching. At the same time
the channel indicator light switches.
Precautions for Function Setting
TOP
Select a display method of normal main sub monitor.
Select by using and fix by .
The screen returns to the TOP of Display
setting.
Displayed in bar display.
Displayed in numeric display.
Displayed in percent (%) display.
Displayed in normal count display.
Displayed in total count display.
No display.
B
C
A
5.2 Display setting
TOP
Set the displayed value on the main monitor to "0."
Select by using and fix by .
The screen returns to the TOP of Zero reset
setting.
Turn on Zero reset.
Turn off Zero reset.
5.1 Zero-reset setting
TOP
Select a detection method from the list below:
Select by using and fix by .
The screen returns to the TOP of Detection
mode setting.
Sets to the rising edge detection.
Sets to the normal detection.
Sets to the trailing edge detection.
Sets to the differential detection.
Detects for length measurement.
5.3 Detection mode setting
TOP
Select a response speed.
Select by using and fix by .
The screen returns to the TOP of Response
speed setting.
Standard setting 500 µs
High accuracy setting 2 ms
Fastest setting 60 µs
2. Response speed setting
TOP
Select an operation mode.
* The timer can be set individually for 1CH and 2CH.
Select by using and fix by .
The screen returns to the TOP of Operation setting.
ON when light is blocked.
ON when light comes in.
1. Operation setting
TOP
Select a timer and the time.
Timer Time Setting 1-9000 (1 ms - 9 s)
Select by using and fix by .
OFF moves to the TOP of Timer setting and
others move to the Timer setting.
is for time changing, is for digit
change, and is to fix. Then the screen
returns to Timer setting TOP.
Off delay timer
Timer off
On delay timer
One shot timer
3. Timer setting
TOP
Correct to the optimal value when sensitivity is
not enough.
Tune on using . The progressing status is
displayed in bar chart. After the end, the
screen returns to the TOP of Sensitivity
correction.
Tune off the sensitivity correction.
Tune on the sensitivity correction.
4. Sensitivity correction
setting
TOP
Initialize all settings.
Select by using and fix by .
The screen returns to the TOP of Initialization
setting.
Initialize
Not initialize
6. Initialization setting
(Initial reset)
7. End of setting
TOP
5. Detailed setting
(Expert mode)
T
Returning to Normal Display with One Button
Pressing the button for 2 seconds or more in setting each function enables to
return to the normal display (RUN mode) without using Eit (Exit).
* Invalid while setting the timer time, number of count, or span slant.
Attaching and Removing to/from DIN rail
Expansion of Amplifier Unit
As many as 8 units can be combined with the
relay connector.
Slide and hook up each amplifier units to DIN rail.
And fix it with End units from the both sides.
Key Lock
Cancels all the operations. Useful to prevent accidental operation.
Hold down the buttons for 2 seconds or more simultaneously in the RUN
mode. Operate in the same way to cancel as well.
During key lock, no command such as all teaching/copy is accepted from other sensors.
T
TIP
BEF-BE01-W190 (2 pcs)
End Unit
Open the protective cover and plug the connector into the amplifier unit with the
lock lever facing up.
Make sure that it clicks.
When removing, hold down the lock lever and pull out the connector.
Do not attach any sensor head other than the specified one (DS Series).
When removing the connector, do not pull on the cable.
Failure to do so will break the cable or damage the product.
(Unit: mm)
D2SA-M
D2SA-M 3
D2SA-S
D2SA-S 1
D2SA-M-M8
D2SA-S-M8
Press the mode button.
* The timer can be set individually for 1CH and 2CH.
* Parallel use of On delay timer and Off delay timer in the
same channel same channel is not possible.
Number of count setting 0 - 9999999
is for count change, is for digit
change, and is to fix. The screen returns
to the Timer Setting TOP.
Slant setting
is for slant change, is for digit
change, and is to fix. The screen returns
to the TOP of Span setting.
* Settings are only for tuning on (ON) or tuning off
(OFF).
Initializing changes all settings to the factory default.
A
Moves to the Detailed setting menu.
D
*External teaching can be available in several teachings
which are chosen by appropriate adjusting methods.
Moves to the analog function setting
detail menu.
Returns to the normal display.
* Make sure to connect two amplifier units before
differential detection.
Valid only for DSTA-200/DSTA-200-M8.
"cnt" or "tcnt" can be select only when the counter
function is valid.
TOP
Set the slant of output.
Select by using and fix by .
The screen moves to each detail setting.
Set 20 mA.
Set 4 mA.
D
5.7.2 Span setting
TOP
Select either read out or turn off the analog output.
Select by using and fix by .
The screen returns to the TOP of Analog
output setting.
Reads out.
Turns off.
5.7.1 Analog output setting
TOP
Select a measurement value state when
measurement is impossible.
Select by using and fix by .
The screen returns to the TOP of Output
clamp hold setting.
Hold just before measurement
becomes impossible.
Set the output to approx. 24 mA.
5.7.3 Output clamp hold
setting
TOP
Select a number of times of sampling.
Select by using and fix by .
The screen returns to the TOP of Average
counter setting.
Set.
Average counter
1/4/8/16/32/64/128/256/
512/ 1024/2048
5.7.4 Average counter setting
TOP
A single unit operates the teaching of all connected
amplifier units.
Select by using and fix by .
The screen returns to the TOP of All one-
point teaching setting.
Performs all one point teaching.
Does not perform teaching.
B
C
5.10 All one point teaching
setting
TOP
Set the displayed value on the main monitor of
connected amplifier units to 0.
Select by using and fix by .
The screen returns to the TOP of All zero-reset setting.
Performs all zero-reset.
Does not perform Zero-reset.
5.9 All zero-reset setting
TOP
Select counter function ON/OFF and a increasing/
decreasing direction of value.
Select by using and fix by .
OFF moves to the TOP of Counter setting,
and the others to number of count setting.
Sets the count value to the increasing direction.
Counter off
Sets the count value to the decreasing direction.
5.4 Counter setting
TOP
Select an assignment of external input.
Select by using and fix by .
The screen returns to the TOP of External
input setting.
Sets to the laser off input.
Sets to the hold reset input.
Sets to the external teaching input.
Sets to the synchro input.
(available only in use of length measurement function)
Sets to the counter value reset
input.
5.6 External input setting
TOP
5.7 Analog function setting
*D2SA-M 3/D2SA-S 1/D2SA-S -M8 do not allow
these settings.
TOP
Select a hold state.
Select by using and fix by .
The screen returns to the TOP of Hold setting.
Peak hold
Normal measurement
Bottom hold
Peak to Peak hold
5.7.5 Hold setting
5.7.6 End of Analog function
setting
TOP
Select an output method of 1CH and 2CH.
Select by using and fix by .
The screen returns to the TOP of Output setting.
1CH: Control output,
2CH: Alarm output
1, 2CH: Control output
5.5 Output setting
TOP
Copy the setting to the connected amplifier units.
Select by using and fix by .
The screen returns to the TOP of All copy setting.
Makes copy.
Does not copy.
5.8 All copy setting
The key-locked amplifier unit setting is not
modified.
TIP
The key-locked amplifier unit is not reset.
TIP
The key-locked amplifier unit does not perform
teaching.
TIP
TOP
Select a width of flood line of sensor head.
Select by using and fix by .
The screen returns to the TOP of Length
measurement standard value setting.
Sets to 3000.
Turns off the setting.
5.11 Length measurement
standard value setting
5.12 End of Detail Setting
(Expert mode)
Returns to the TOP of Detail Setting (Expert mode).
Returns to the TOP of Analog function setting.
* Full scale of the default is as follows:
Transmission, Regressive reflection, or Reflection type:
0 - 4000 (Amount of received light)
Transmission type and in setting length measurement:
0 - 3000 (Received light = Line width)
T
In locking When cancelled
T
T
T
After end of 4A setting, the screen moves to 20A setting.
*
Some function settings automatically delete the invalid settings or settings, of which
concomitant use is not allowed, from the displayed items. This does not indicate any failure.
* Some functions are not incorporated or not settable to D2SA-M 3 /D2SA-S
1 /D2SA-M -M8 /D2SA-S -M8.
*
Hold down the operation button for approx. 0.3 seconds if not especially specified.
* Analog output and Analog setting is available when response time setting is
"Long" or "Standard".
* The sub monitor starts flashing when each setting selection becomes available.
* The monitor in use of the counter function displays "U" when the up-counter
is selected, and displays "d" when the down-counter is selected.
* For functions other than Operation setting and Timer setting, both settings of 1
CH and 2 CH are changed when the setting of each function is modified.
* The "all setting" described in 5.8 to 5.10 is reflcted only on the amplifier unit
connected to the right side from the cable connector of operated amplifier unit.
* D2SA-M 3/D2SA-S 1/D2SA-M -M8/D2SA-S -
M8 do not allow these settings.
* D2SA-M 3/D2SA-S 1/D2SA-M -M8/D2SA-S -M8 cannot be switched as they have a
single output (1CH).
Attachment of Amplifier Unit
Hook the claw on the connecting side of
sensor head to the DIN rail. Then press
down the hook until it locks.
Removal of Amplifier Unit
Pushing the unit to the direction of , hold
up the connecting side of sensor head and
remove the unit.
* Make sure to turn off the power before operation.
* Make sure to use the DIN rail and the end unit (BEF-BE01-W190) in
expanding the amplifier unit.
* After expansion, make sure to check the operating temperature
(See "Specification").
* To avoid short of connecting terminal, protection cover
need to be attached to ones which are not in use.
* Do not remove the combined units all together from DIN rail.
CAUTION
CAUTION
Webs ite http://www.optex-fa.com
The product specification may change without notice for improvement.
For any inquiry, please contact the manufacture/vendor below.
End unit
Lock Lever
Reset "Peak/ Bottom hold"
Peak/Bottom hold can be reset by operating with amplifier itself at the time of
analog output.
SET
R
UN
Confirm the position of "SET/RUN" switch is snapped to "RUN" side.
Move the position to "SET" side and return to "Run" side again.
    ②
Connector
Base unit
Handset
Protection
Cover
Head office:
Mitsui Seimei Kyoto Yamashina BLDG 6F, 46-1
Takehanadounomae-cho, Yamashina-ku, Kyoto
607-8085 Japan
TEL: +81-(0)75-594-8123
FAX: +81-(0)75-594-8124
CAUTION
WARNING
Digital Amplifier Detachable Photoelectronic Sensor
D2SA Series
Laser Type Amplifier Unit D2SA-MS
D2SA-M3S
D2SA-MS-M8
Instruction Manual
Safety Precautions
Operational Precautions
Carefully read and understand the safety precautions before operation.
The important information is provided to protect your health and property.
Do not apply any other installing or operating procedure other than that described in
this manual.
Meaning of Safety Symbols
Indicates a possible hazard that may result in
personal injury or property damage if the product is
used without observing the stated instructions.
Indicates a possible hazard that may result in death,
serious injury, or serious property damage if the
product is used without observing the stated
instructions.
This product is not an explosion-proof construction.
Do not use the product under flammable, explosive gas
or liquid environment.
Do not use the product in water.
Do not disassemble, repair, or convert the product.
Failure to do this may cause failure, fire, or electric
shock.
Operate within the rated range.
This product cannot be used as a safety device to
protect human body.
Mandatory Requirements
Specification Each Part
Adjustment
Input/Output Schematic
NPN PNP
D2SA-MNS D2SA-MPS
D2SA-MNS-M8 D2SA-MPS-M8
D2SA-MN3S D2SA-MP3S
Auto Teaching
Zone Teaching
Two Points Teaching Teaching Transparent Object
Teaching Length Measurement
SET
R
UN
Switch to SET.
SET
R
UN
Switch to RUN.
Select the one-point teaching.
Press the teaching button.
T
The threshold flashes and the
display returns to normal.
Transmission Type (In length
measurement)
SET: Press the teaching button when
there is no object with the flood light
and the light receiver facing each
other.
IN: Press the teaching button when
there is an object.
Reflection, Transmission, Regressive
Reflection Type
Start and End: Perform adjustment
while the object is passing.
Reflection type: Perform adjustment
with the background without object,
and when there is an object.
Set the zone (detection range) to ±10 %
against the amount of received light.
Set the threshold at the center between
the 1st and the 2nd points.
2nd: Perform adjustment with the
background without object.
Reflection type
1st: Perform adjustment when there is
an object.
Rotating reflection type: Perform when
there is no object.
SET
R
UN
Switch to SET.
SET
R
UN
Switch to RUN.
Select the one point teaching.
Press the teaching button.
T
The threshold flashes and the
display returns to normal.
SET
R
UN
Switch to SET.
SET
R
UN
Switch to RUN.
Select the auto teaching.
End: Press the teaching button.
Start: Press the teaching button.
The threshold flashes and the
display returns to normal.
Model
D2SA-M(N/P)S
DS Series
Adaptable sensor head
12 - 24 V DC ± 10 % including a ripple
Power source, voltage
Cable type
- D2SA-M(N/P)S-M8
D2SA-M(N/P)3S
M8 connector type
60µs/500µs/2ms (Fast/Standard/Long)Response time
45 mA or less / 24 VConsumption current
Load current: 100 mA or less Residual voltage:1.8 V or less
Control output
Laser emission indicator light: Green, Output Indicator light: Orange (1·2CH)
Teaching indicator light: Red Channel indicator light: Green (1·2CH)
7 segment 8 digit display
Digital display
Timer function
10 to 55 Hz Double amplitude 1.5 mm 2 hours for each direction of X, Y, and Z
OFF, On delay, Off delay, One-shot
1 ms - 9 sTimer time
Light on / Dark on Switching type in the function
Output method
Current output:4 - 20 mA -Analog output
External input setting
(teaching, synchronizing input,
floodlight off, counter reset)
Output setting
(
2CH output + Alarm output
)
External input setting
(teaching, synchronizing input,
floodlight off, counter reset)
Setting input/output
-25 to +55°C / 35 to 85 % RH (No freezing)
Operating temperature/humidity
-40 to +70°C / 35 to 85 % RH (No condensation)
Store temperature/humidity
IP50Protective category
Shock resistance
Indicator light
Advanced Model (2CH) Standard Model (1CH)
PC: Case and coverMaterial
Cable type: 65 g M8 connector type: 30 g
Weight (including the codes)
NPN / PNP Open collector
* Settable only with DSA-M S-M8
Pin layout
D2SA-M -M8
1
24
3
External input
12 to 24 V DC
Control output
0 V
Setting Maximum Sensitivity
One Point Teaching
Transmission type
Regressive Reflection type: Perform
adjustment when there is an object.
Reflection type: Perform adjustment
when there is no object.
Reflection type: Perform adjustment
with the background without object.
Set the threshold to + % against the amount
of received light.
(Depends on the response speed setting.)
Threshold
Threshold
Upper limit
Lower limit
10%
10%
Zone
Near
Far
Valid only when the length measurement function is set. Allows to
determine the size or the length of object.
* Not displayed on the teaching mode menu unless the application of length
measurement is selected in the detection mode setting.
* Teaching length measurement or length measurement mode does not measure the
actual length of object accurately.
Manual Adjustment
Pressing the UP/DOWN button in the RUN mode flashes the threshold. It
indicates that adjustment is possible. Adjust to any value using the
UP/DOWN button.
When using the zone teaching, the threshold of upper/lower limit can be set
individually.
The available teaching depends on "5.3 Detection Mode setting." Refer to
below:
Error Display in Teaching
An error message is displayed in the event of error during adjustment.
Refer to the table below for readjustment.
* No operation state for 5 seconds during setting automatically returns the display to
normal as well.
SET
R
UN
Switch to SET.
SET
R
UN
Switch to RUN.
Select the two points teaching.
2nd point: Press the teaching button.
T
1st point: Press the teaching button.
T
T
T
The threshold flashes and the
display returns to normal.
SET
R
UN
Switch to SET.
SET
UN
Switch to RUN.
IN: Press the teaching button.
SET: Press the teaching button.
T
T
The upper limit flashes and
the display returns to normal.
SET
R
UN
Switch to SET.
SET
R
UN
Switch to RUN.
Press the teaching button.
T
The threshold flashes and the
display returns to normal.
SET
R
UN
Switch to SET.
SET
R
UN
Switch to RUN.
Select the zone teaching.
Press the teaching button.
T
The threshold flashes and the
display returns to normal.
Normal
Automatically returns to
the normal display 5
seconds after completion of
the setting (no operation).
When using zone teaching
Setting Lower Limit (Far)
Automatically returns to the normal display 5
seconds after completion of the setting
(no operation).
Indicates shortage of light intensity or no difference
of light intensity.
Indicates a sampling error in teaching of a moving object.
Indicates a calculation error.
Indicates that the teaching is interrupted.
Setting Upper Limit (Near)
Thank you for purchasing DSA Series. We hope you are fully satisfied with this product and enjoy its
performance.
Carefully read this instruction manual and keep it for future reference.
WARNING
CAUTION Use the specified sensor head to connect this product.
Any use other than specified will cause accident or
product damage.
It is dangerous to wire or attach/remove the connector
with the power on. Make sure to turn off the power
before operation.
Make sure to use the product with the protective cover
attached and closed.
Installing in the following places may result in
malfunction:
1. A dusty or steamy place
2. A place generating corrosive gas
3. A place directly receiving scattering water or oil.
4. A place suffered from heavy vibration or impact.
The product is not designed for outdoor use.
Do not use the sensor in transient state after power on
(approx. 100 ms).
Do not wire with the high voltage cable or the power line.
Failure to do this will cause malfunction by induction or
damage.
The sensor performance or digital display values may depend
on the individual units or the condition of detected product.
NameNo. Function
Laser emission indicator light
Turns on while the amplifier is powered.
1 CH output indicator light
Turns on when the output of 1 CH is ON.
2 CH output indicator light
Turns on when the output of 2 CH is ON.
Main monitor (Red)
Displays light intensity, function, and the number of counts.
Sub monitor (Green)
Displays the threshold, function selection, and the number of counts.
Teaching mode indicator light
Turns on in the Teaching mode.
Valid channel indicator light
(1 CH)
Keeps turning ON when the monitor display value,
adjustment, and the function setting are valid to 1 CH.
Valid channel indicator light
(2 CH)
Keeps turning ON when the monitor display value,
adjustment, and the function setting are valid to 2 CH.
UP button RUN mode: Displays or changes the threshold.
DOWN button
Function mode: Selects the function or changes the numerical values.
Mode button RUN mode: Switches to the Function mode. (0.5 s
)
Function mode: Fix the selection.
Teaching button RUN mode: Switches the channel.
Function mode: Returns to RUN mode or performs scaling.
Set mode: Run the teaching.
SET/RUN selection switch
Switches between Teaching mode and RUN mode.
* The button function varies in each mode: RUN mode, Function mode, and SET mode.
* D2SA-M 3S/D2SA-M S-M8 are 1 output (1 CH) type, and do not turn on.The
channel switching of also becomes invalid.
Main circuit
Protective
circuit Protective
circuit
Load
Load
Black and
white
Gray
Blue
White
Black
Brown
Analog
output
0 V
Analog
GND
External
input
Control output
1 CH
12 to 24V
DC
Control output
2 CH
Main circuit
Protective
circuit Protective
circuit
Load
Load
Black and
white
Gray
Blue
White
Black
Brown
Analog
output
0 V
Analog
GND
External
input
Control output
1 CH
12 to 24 V
DC
Control output
2 CH
Main circuit
Protective
circuit
Load
Gray
Blue
Black
Brown
12 to 24 V
DC
Control output
1 CH
External
input
0 V
1
4
2
3
Main circuit
Protective
circuit
Load
12 to 24 V
DC
Control output
1 CH
External
input
0 V
Gray
Blue
Black
Brown
1
4
2
3
Main circuit
Protective
circuit
Load
12 to 24 V
DC
Control output
1 CH
0 V
Brown
1
Black
4
Blue 3
Main circuit
Protective
circuit
Load
12 to 24 V
DC
Control output
1 CH
0 V
Brown
1
Black
4
Blue 3
/
Long +1%
Stnd +5%
FaSt +15%Threshold
2nd
1st
Threshold
Set the threshold to -10 % against the
amount of received light.
-10%
Threshold
Reflection side
of reflector
(Standard detection) All teachings are valid.
(Edge detection) No teaching are valid.
(Differential detection) Only one point teaching is valid.
Function Setting
Connecting Sensor Head
Dimensional drawing
Options
Setting Amplifier Unit
Switching Channel
Pressing the button during the RUN mode allows switching. At the same time
the channel indicator light switches.
Precautions for Function Setting
TOP
Select a display method of normal main sub monitor.
Select by using and fix by .
The screen returns to the TOP of Display
setting.
Displayed in bar display.
Displayed in numeric display.
Displayed in percent (%) display.
Displayed in normal count display.
Displayed in total count display.
No display.
B
C
A
5.2 Display setting
TOP
Set the displayed value on the main monitor to "0."
Select by using and fix by .
The screen returns to the TOP of Zero reset
setting.
Turn on Zero reset.
Turn off Zero reset.
5.1 Zero-reset setting
TOP
Select a detection method from the list below:
Select by using and fix by .
The screen returns to the TOP of Detection
mode setting.
Sets to the rising edge detection.
Sets to the normal detection.
Sets to the trailing edge detection.
Detects for length measurement.
5.3 Detection mode setting
TOP
Select a response speed.
Select by using and fix by .
The screen returns to the TOP of Response
speed setting.
Standard setting 500 µs
High accuracy setting 2 ms
Fastest setting 60 µs
2. Response speed setting
TOP
Select an operation mode.
* The timer can be set individually for 1CH and 2CH.
Select by using and fix by .
The screen returns to the TOP of Operation setting.
ON when light is blocked.
ON when light comes in.
1. Operation setting
TOP
Select a timer and the time.
Timer Time Setting 1-9000 (1 ms - 9 s)
Select by using and fix by .
OFF moves to the TOP of Timer setting and
others move to the Timer setting.
is for time changing, is for digit
change, and is to fix. Then the screen
returns to Timer setting TOP.
Off delay timer
Timer off
On delay timer
One shot timer
3. Timer setting
TOP
Correct to the optimal value when sensitivity is
not enough.
Tune on using . The progressing status is
displayed in bar chart. After the end, the
screen returns to the TOP of Sensitivity
correction.
Tune off the sensitivity correction.
Tune on the sensitivity correction.
4. Sensitivity correction
setting
TOP
Initialize all settings.
Select by using and fix by .
The screen returns to the TOP of Initialization
setting.
Initialize
Not initialize
6. Initialization setting
(Initial reset)
7. End of setting
TOP
5. Detailed setting
(Expert mode)
T
Returning to Normal Display with One Button
Pressing the button for 2 seconds or more in setting each function enables to
return to the normal display (RUN mode) without using Eit (Exit).
* Invalid while setting the timer time, number of count, or span slant.
Attaching and Removing to/from DIN rail
Key Lock
Cancels all the operations. Useful to prevent accidental operation.
Hold down the buttons for 2 seconds or more simultaneously in the RUN
mode. Operate in the same way to cancel as well.
T
BEF-BE01-W190 (2 pcs)
End Unit
Open the protective cover and plug the connector into the amplifier unit with the
lock lever facing up.
Make sure that it clicks.
When removing, hold down the lock lever and pull out the connector.
Do not attach any sensor head other than the specified one (DS Series).
When removing the connector, do not pull on the cable.
Failure to do so will break the cable or damage the product.
(Unit: mm)
D2SA-M S
D2SA-M 3S
Press the mode button.
* The timer can be set individually for 1CH and 2CH.
* Parallel use of On delay timer and Off delay timer in the
same channel same channel is not possible.
Number of count setting 0 - 9999999
is for count change, is for digit
change, and is to fix. The screen returns
to the Timer Setting TOP.
Slant setting
is for slant change, is for digit
change, and is to fix. The screen returns
to the TOP of Span setting.
* Settings are only for tuning on (ON) or tuning off
(OFF).
Initializing changes all settings to the factory default.
A
Moves to the Detailed setting menu.
D
Moves to the analog function setting
detail menu.
Returns to the normal display.
Valid only for DSTA-200/DSTA-200-M8.
"cnt" or "tcnt" can be select only when the counter
function is valid.
TOP
Set the slant of output.
Select by using and fix by .
The screen moves to each detail setting.
Set 20 mA.
Set 4 mA.
D
5.7.2 Span setting
TOP
Select either read out or turn off the analog output.
Select by using and fix by .
The screen returns to the TOP of Analog
output setting.
Reads out.
Turns off.
5.7.1 Analog output setting
TOP
Select a measurement value state when
measurement is impossible.
Select by using and fix by .
The screen returns to the TOP of Output
clamp hold setting.
Hold just before measurement
becomes impossible.
Set the output to approx. 24 mA.
5.7.3 Output clamp hold
setting
TOP
Select a number of times of sampling.
Select by using and fix by .
The screen returns to the TOP of Average
counter setting.
Set.
Average counter
1/4/8/16/32/64/128/256/
512/ 1024/2048
5.7.4 Average counter setting
B
C
TOP
Select counter function ON/OFF and a increasing/
decreasing direction of value.
Select by using and fix by .
OFF moves to the TOP of Counter setting,
and the others to number of count setting.
Sets the count value to the increasing direction.
Counter off
Sets the count value to the decreasing direction.
5.4 Counter setting
TOP
Select an assignment of external input.
Select by using and fix by .
The screen returns to the TOP of External
input setting.
Sets to the laser off input.
Sets to the external teaching input.
Sets to the synchro input.
(available only in use of length measurement function)
Sets to the counter value reset
input.
5.6 External input setting
TOP
5.7 Analog function setting
* D2SA-M 3S 1 do not allow these settings.
TOP
Select a hold state.
Select by using and fix by .
The screen returns to the TOP of Hold setting.
Peak hold
Normal measurement
Bottom hold
Peak to Peak hold
5.7.5 Hold setting
5.7.6 End of Analog function
setting
TOP
Select an output method of 1CH and 2CH.
Select by using and fix by .
The screen returns to the TOP of Output setting.
1CH: Control output,
2CH: Alarm output
1, 2CH: Control output
5.5 Output setting
TOP
Select a width of flood line of sensor head.
Select by using and fix by .
The screen returns to the TOP of Length
measurement standard value setting.
Sets to 3000.
Turns off the setting.
5.11 Length measurement
standard value setting
5.12 End of Detail Setting
(Expert mode)
Returns to the TOP of Detail Setting (Expert mode).
Returns to the TOP of Analog function setting.
* Full scale of the default is as follows:
Transmission, Regressive reflection, or Reflection type:
0 - 4000 (Amount of received light)
Transmission type and in setting length measurement:
0 - 3000 (Received light = Line width)
T
In locking When cancelled
T
T
T
After end of 4A setting, the screen moves to 20A setting.
*
Some function settings automatically delete the invalid settings or settings, of which
concomitant use is not allowed, from the displayed items. This does not indicate any failure.
*
Some functions are not incorporated or not settable to D2SA-M 3S /D2SA-M
S
-M8.
*
Hold down the operation button for approx. 0.3 seconds if not especially specified.
* Analog output and Analog setting is available when response time setting is
"Long" or "Standard".
* The sub monitor starts flashing when each setting selection becomes available.
* The monitor in use of the counter function displays "U" when the up-counter
is selected, and displays "d" when the down-counter is selected.
* For functions other than Operation setting and Timer setting, both settings of 1
CH and 2 CH are changed when the setting of each function is modified.
* D2SA-M 3S/D2SA-M S-M8 do not allow these
settings.
* D2SA-M 3S/D2SA-M S-M8 cannot be switched as they have a single output (1CH).
Attachment of Amplifier Unit
Hook the claw on the connecting side of
sensor head to the DIN rail. Then press
down the hook until it locks.
Removal of Amplifier Unit
Pushing the unit to the direction of , hold
up the connecting side of sensor head and
remove the unit.
CAUTION
Website http://www.optex-fa.com
The product specification may change without notice for improvement.
For any inquiry, please contact the manufacture/vendor below.
Maximum aperture 180˚
Lock Lever
D2SA-M S-M8
Sets to the hold reset input.
Reset "Peak/ Bottom hold"
Peak/Bottom hold can be reset by operating with amplifier itself at the time of
analog output.
SET
R
UN
Confirm the position of "SET/RUN" switch is snapped to "RUN" side.
Move the position to "SET" side and return to "Run" side again.
    ②
* External teaching can be available in several teachings
which are chosen by appropriate adjusting methods.
Head office:
Mitsui Seimei Kyoto Yamashina BLDG 6F, 46-1
Takehanadounomae-cho, Yamashina-ku, Kyoto
607-8085 Japan
TEL: +81-(0)75-594-8123
FAX: +81-(0)75-594-8124
デジタルアンプ分離型光電センサ
DSシリーズ
レーザタイプセンサヘッド  DSR ‑800  DSTC‑200‑M8
DSR ‑5000  DSTA‑200‑M8
  DSD ‑100
  DSTC‑200
  DSTA‑200
● 
お買い上げいただきありがとうございます、ご希望どおりの製品であることをご確認して下さい。
● 取扱い説明書は、ご使用前によくお読みいただき大切に保管して下さい。
取扱い説明書
安全にご使用いただくために
付属品・その他
レーザ使用に関する注意事項 仕様 外形寸法図
使用上の注意
取扱い説明書に記載されている注意事項をよくお読みになり、内容を理解され
るまではお使いにならないでください。
取扱い説明書には、お客様の健康や財産を守るための注意事項が記載されてい
ますので記載の無い据付け・操作方法ではご使用にならないで下さい。
レーザ放射がされていることをレーザ放射警告灯で確認していただけます、電
源を入れたあと点灯し、放射されている間常時点灯します。また、専用アンプ
ユニット側でも確認できます。
■記号表記について
■レーザ放射警告灯
この商品は可視光レーザビームを放射しており、JIS C6802 / IEC / FDAレーザ 
安全規格のクラス2(Ⅱ)に相当します、センサヘッド側にはCLASS2/ClassⅡ 
を示す警告、説明ラベル(英文)をそれぞれ貼付済みです。
*DSTC‑200/‑M8・/DSTA‑200/‑M8の投光器DSTC‑D/DSTA‑D及びDSTC‑S/DSTA‑SはFDA規格(米国
へ輸出される場合)ではクラスⅡですがJIS/IEC規格ではクラス1が適用されますので 
同梱されているラベルを張り替えて使用してください。
機器搭載して米国へ輸出する場合、米国のレーザ規制FDA  (Food  and  Drug 
Administration)を受けます。この商品はCDRH  (Center  for  Devices  and 
Radiological  Health) に届出済みです。詳細は別途お問い合わせください。
■レーザラベルについて
DSTA‑200・‑M8を測長用途で使用される場合は次のことに注意して下さい。
■DSTA‑200/DSTA‑200‑M8使用時の注意
DSR‑800・DSR‑5000  にアタッチメントを取り付けて、ラインビーム・エリアビ
ームの2種で検出が可能です、ご使用になるビーム形状レンズと光軸をあわせ
て取り付けてください。
*製品個々のばらつきによりビーム形状に違いが生じることがあります。
*DSD‑100には適しません、またDSTA‑200・M8/DSTA‑Sに
 取り付けることはできません。
■レンズアタッチメント(型式 BL‑W130L‑1:オプション)
●使用上の注意
1. 
清掃される場合はエアで吹き飛ばすかやわらかい布で軽くふき取ってください
  シンナー、ベンジン、灯油類は使用しないでください。
2. 反射面を強く押したり、直接衝撃を与えたりしますと、プリズムが破損し
性能の低下が起こる恐れがあります。
3. 屋外や油・水が飛散する環境下での使用は避けてください。
●取り付け方法
取り付けは下図を参考に正しい方向で使用してください、誤った取り付けを行
うと誤動作の原因となります。
■MP‑45リフレクタ(DSR‑800・DSR‑5000に付属)
この表示を無視して誤った取り扱いをすると、人が負傷
する可能性が想定される内容、および物的損害の発生
想定される内容を示します。
この表示を無視して誤った取り扱いをすると、人が死亡
または重症を負う可能性が想定される内容を示します。
また、重大な物的損害を受ける恐れがあります。
●この商品は防爆構造ではありませんので、引火性または爆
発性ガス、液体の環境下では使用しないで下さい。
●この商品の光源は可視光半導体レーザを使用しています。
●この商品は分解したときに自動的にレーザ放射を停止する
機能を備えておりませんので、分解・改造をしないで下 
さい。
  人体への障害・火災・感電の原因になります。
●レーザビームを直接覗き込んだり、周囲の人の目線高さに 
設置・故意に人体にけて射するなどはしない下さい。
●この商品の接続には用アプユニットを使用し下さい、
  他のものを接続しまと事・商品破損の原因とります。
●電源が入ったままの線作・コネクタの脱着は険です、
  必ず電源を切ってから行ってください。
●次のような場所への設置は誤動作の原因となる事がありま
すのでご注意ください。
1. ホコリ・蒸気等の多い場所。
2. 腐食性ガスの発生する場所。
3. 水・油等が直接飛散する場所。
4. 振動・衝撃等の激しい場所。
●屋外・強い外乱光(レーザ光・太陽光・白熱ランプ)が 
直接受光面にあたる場所での使用は避けて下さい。
●電源投入時(約100ms)の過度状態でのご使用は避けて下 
さい。
●商品個々のばらつきや、対象物の状態によって検出特性に
違いが生じることがあります。
●投受光面にゴミ・ほこり等の汚れがありますと正しく検出
できない場合があります、また直接衝撃を与えないで下 
さい。
この商品は人体保護を目的とした安全機器としては
ご使用いただけません。
●日本国内
●諸外国(米国を除く)
●米国
●投光器は灰色ケーブル、受光器は黒色ケーブルに対応しています。
●センサの取付けは、投光ビーム中心が受光部中心に来るように設置してくだ
さい。 
(アンプユニットの表示値が最大になるように設置してください。)
●投・受光器の設置は同一方向になるようにしてください。各ラベルや表示灯
を基準にしてください。
同軸回帰反射型 同軸反射型 透過型
型式
透過/測長型
800 5000
DSR‑
DSD‑100
DSTC‑200 DSTA‑200
DSA‑M□□  /DSA‑M□‑M8 /  DSA‑S□□
適合アンプユニット
可視光半導体レーザ 650nm光源
投光器:DSTC‑D 投光器:DSTA‑D
ケーブル
受光器:DSTC‑200 受光器:DSTA‑200
DSTC‑200‑M8 DSTA‑200‑M8
M8中継型
DSTC‑S DSTA‑S
投光器M8
DSTC‑R DSTA‑R
受光器M8
Standard
Fast
Long
CLASS 2IEC/JIS CLASS CLASS 1
最大出力 3mW出力 最大出力 390μW
Class ⅡFDA CLASS
8m
1m
2m
5m
0.7m
2m
測長モード;0.5m
2m
0.5…50m
0.3…35m
0.1…20m 0.25m
(Long ,Standardのみ)
約φ2mm
ビームサイズ    *2 約φ1mm
約φ2mm 約30x2.5mm
45g 90g 115g
(距離2m)
(距離1m)
(距離2m) (距離2m)
0.2mm 0.2mm 0.2mm 0.3mm
レーザ放射表示灯:緑色  出力表示灯:橙色表示灯
繰り返し精度
  
*3
‑10~+55℃/35~85%RH (氷結・結露しないこと)
使用周囲温度・湿度
‑25~+70℃/35~85%RH (氷結・結露しないこと)
保管周囲温度・湿度
3,000 lx (白熱ランプ)       10,000 lx (太陽光)使用周囲照度
10~55Hz  複振幅1.5mm  X,Y,Z各方向2時間耐振動
IP67保護構造
PC (ケース,カバー)   PMMA / ガラス(前面窓)材質
質量(コード含む)*4
検出距離
*1
*1 DSD‑100 :200x200mm 白紙(90%)にて 
  DSR‑800 :MP‑45リフレクタ(付属)にて
  DSR‑5000 :P250Fリフレクタ(付属)にて
*2 中心強度の1/e2(13.5%)で定義しています。規定のスポットサイズ以外にも漏れ光が 
あり対象物の周囲に反射率の高いものがある場合その影響を受ける場合があります。
*3 検出軸に直角方向(2mまで)
*4 DSTC‑200・DSTA‑200は投・受光器込みの質量です。
*  M8中継型は投光器・受光器のみの交換が可能です。
安全上必ずお守りください
ラインビーム
エリアビーム
約40 x 1mm
(距離300mm)
約35 x 35mm
(距離300mm)
ビーム形状
・DSTA‑200 ・DSR‑800
・DSR‑5000
・DSD‑100
・DSTC‑200
・DSTA‑200‑M8
・MP‑45
・DSTC‑200‑M8
・P250F
● 製品の仕様は改良のため予告なく変更する事があります。
● 製品に関するお問い合わせ、御意見等は製造・発売元の下記まで御連絡下さい。
0536692
13
13.4
2‑φ3.2
2.7
52.9
36.6
31.65
レーザ放射表示灯 出力表示灯
10.6
23.5(光軸中心)
16.1
6
37.4
9.9
12.35
18.5
8.2
34
46.4
52.9
25.9
47
41.4
φ3 2芯 ケーブル 標準長 2m(灰)
φ3 4芯 ケーブル 標準長 2m(黒)
2‑R2.6
2‑φ3.2
取付け穴
2.8
2
3
4
1
23.5(光軸中心)
9.9
37.4
6
16.1
31.65
36.6
52.9 2.7
13.4
13
10.6
出力表示灯
レーザ放射表示灯
2‑φ3.2
φ3 4芯 ケーブル 標準長 0.15m(黒) 先端M8プラグ
φ3 2芯 ケーブル 標準長 0.15m(灰) 先端M8プラグ
取付け穴
2‑φ3.2
2.8 41.4
47
34
8.2
25.9
52.9
46.4
2‑R2.6
6
18.5
12.35
1
4
3
2
φ3 4芯 ケーブル 標準長 2m(黒) 先端M8ジャック
φ3 2芯 ケーブル 標準長 2m(灰) 先端M8ジャック
2
0.2
4.5
23
7.4
7.4
29
14.5
44.8
23
37
2‑R3.7
4‑R1.2
2‑φ3.2
4‑C3
レーザ放射警告灯
        (緑点灯)
FDA警告/
レーザ開口ラベル(2)(3)
証明ラベル(1)
FDA警告/レーザ開口
証明ラベル(4)
表示灯
表示灯
表示灯
ラインビーム
レンズ
エリアビーム
レンズ
(DSTA‑D/DSTA‑S)
(DSR‑800/DSR‑5000
 DSD‑100/DSTC‑D
 DSTC‑S) (DSTA‑D/DSTA‑S)
(単位:mm)
(DSR‑800/DSR‑5000
 DSD‑100/DSTC‑D/DSTC‑S)
オプテックス・エフエーホームページ
http://www.optex-fa.jp
(1)
(2) (4)
(3)
13
13.4
34.6
21.
16.1
出力表示灯
レーザ放射表示灯
2‑φ3.2
16.1
6
11.2
10.6
18.6(光軸中心)
R2.6
R2.6
2‑φ3.2
取付け穴
12.7
19.1
12.35
18.5
26.5
20.9
2.8
28.1
34.6
φ3 4芯 ケーブル 標準長 2m(黒)
DSTC    :φ3 2芯 ケーブル 標準長 2m(灰)
DSR/DSD :φ3 4芯 ケーブル 標準長 2m
1
4
3
2
6.5
2‑φ3.2
16.1
21.
34.6
13.4
13
レーザ放射表示灯 出力表示灯
6
34.6
28.1
6.5
2.8 20.9
26.5
18.6(光軸中心)
10.6
11.2
18.5
6
16.1
12.35
19.1 12.7
φ3 4芯 ケーブル 標準長 0.15m(黒) 先端M8プラグ
φ3 2芯 ケーブル 標準長 0.15m(灰) 先端M8プラグ
φ3 4芯 ケーブル 標準長 2m(黒) 先端M8ジャック
φ3 2芯 ケーブル 標準長 2m(灰) 先端M8ジャック
2
3
4
1
R2.6
R2.6
2‑φ3.2
取付け穴
ヘッド取説.indd 2 2006/01/24 14:33:06
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

OPTEX FA D2SA-SN ユーザーマニュアル

タイプ
ユーザーマニュアル
このマニュアルも適しています

他の言語で