Omron E3C-LDA N Series ユーザーマニュアル

カテゴリー
オーディオアンプ
タイプ
ユーザーマニュアル
E3C-LDAN Series
©
OMRON Corporation 2022 All Rights Reserved.
Photoelectric Sensors
with Separate Digital Amplifiers
Laser-type Amplifier Units
Dimensions in parentheses ( ) indicates the ones with related components.
The cover could come off if it is tilted by 170 degrees or more.
• Amplifier Unit: 1 • Instruction Sheet, Compliance sheet
Warning Indications
Indicates a potentially hazardous situation which, if not avoided,
will result in minor or moderate injury, or may result in serious injury
or death. Additionally there may be significant property damage.
PRECAUTIONS FOR SAFE USE
Checking the Package Content
The following precautions must be observed to ensure safe operation of the product. Doing so may cause
damage or fire.
· Do not install the product in the following locations.
(1) Locations subject to direct sunlight (2) Locations subject to condensation due to high humidity
(3) Locations subject to corrosive gas (4) Locations subject to vibration or mechanical shocks exceeding the rated values
(5) Locations subject to exposure to water, oil, chemicals (6) Locations subject to steam
(7) Locations subjected to strong magnetic field or electric field
· Do not use the product in environments subject to flammable or explosive gases.
· Do not use the product in any atmosphere or environment that exceeds the ratings.
·
To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power devices.
· High-Voltage lines and power lines must be wired separately from this product. Wiring them together or
placing them in the same duct may cause induction, resulting in malfunction or damage.
· Do not apply any load exceeding the ratings. Otherwise damage or fire may result.
· Do not short the load. Otherwise damage or fire may result.
· Connect the load correctly.
· Do not use the product if the case is damaged.
· Burn injury may occur. The product surface temperature rises depending on application conditions, such as the
ambient temperature and the power supply voltage. Attention must be paid during operation or cleaning.
· When setting the sensor, be sure to check safety such as by stopping the equipment.
· Be sure to turn off the power supply before connecting or disconnecting wires.
· Do not attempt to disassemble, repair, or modify the product in any way.
· When disposing of the product, treat it as industrial waste.
· Do not use the Sensor in water, rainfall, or outdoors.
· When joining the product, ensure to connect them to the same power supply and turn the power on at the same
time. The joined unit may not function fully if a separate power supply is used.
· If you notice an abnormal condition such as a strange odor, extreme heating of the unit, or smoke, immediately
stop using the product, turn off the power, and consult your dealer.
· Sensor heads other than E3C-LDA@@N are not usable. If other models are connected, there is a risk of damage.
INSTRUCTION SHEET
Thank you for selecting an OMRON product. This sheet
primarily describes precautions
required in installing and operating the product.
• A specialist who has the knowledge of electricity must
treat the product.
• Please read this manual carefully, and use it correctly
after thoroughly understanding the product.
• Please keep this manual properly for future reference
whenever it is necessary.
The following notice applies only to products that carry the CE mark:
NOTICE
In a residential environment, this product may cause radio interference,
in which case the user may be required to take adequate measures.
WARNING
WARNING
This product is not designed or rated for ensuring safety of persons
either directly or indirectly. Do not use it for such purpose.
Do not use the product with voltage in excess of the rated voltage.
Excess voltage may result in malfunction or fire.
Never use the product with an AC power supply. Otherwise,
explosion may result.
PRECAUTIONS FOR CORRECT USE
· Do not miswire such as the polarity of the power supply.
· Be sure to mount the unit to the DIN track until it clicks.
· When using a connector type product, place a protective label (provided with the
E3X-CN series) on the power supply connecting terminals that are not used, to
prevent electric shock or short circuit.
· The length for the cable extension must be 30 m or less.
Be sure to use a cable of at least 0.3 mm² for extension.
· Do not apply the forces on the cord exceeding the following limits:
Pull: 40 N; torque: 0.1 N·m; pressure: 20 N; bending: 29.4 N
· Do not apply excessive force such as tension, compression or torsion to the connector of the sensor head that is
fixed to the amplifier unit.
· Always keep the protective cover in place when using the product. Not doing so may cause malfunction.
· It may take time until the received light intensity and measured value become stable immediately after the
power is turned on depending on use environment.
· The product is ready to operate 300 ms after the power supply is turned ON.
· The Mobile Console E3X-MC11, E3X-MC11-SV2 and E3X-MC11-S cannot be connected.
· The mutual interference prevention function operates for E3C-LDA@@N. For other models, the product results
in mutual interference.
· Optical communication cannot be performed with a model other than E3C-LDA@@N. If other models are
connected and used, the product may malfunction.
· If the unit receives excessive sensor light, the mutual interference prevention function may not work properly,
resulting in malfunction of the unit. In such case, increase the threshold.
· The Communication Unit E3X-DRT21-S, E3X-CRT, E3X-ECT and E3NW cannot be connected.
· Do not use thinner, benzine, acetone, and lamp oil for cleaning.
· The amplifier unit uses EEPROM memory to save the configuration information. If the memory rewritable time
exceeds its limit (100,000 times), the memory error will be displayed and the amplifier unit needs to be
replaced. Memory data is rewritten, for each operation, three times when tuning, processing zero reset, and
changing the hysteresis width, and ten times when initializing the settings.
· If a crossed out wheelie bin symbol is labeled on the amplifier unit, dispose in accordance with
applicable regulations.
E3C-LDANSeries
Installation
1
Dimensions
1-1
Input / Output Circuit Diagram
1-2
*1. E3C-LDA21N only *2. E3C-LDA51N only
1. Let the hook on the Amplifier Unit's Sensor Head
connection side catch the track.
2. Push the unit until the hook clicks into place.
Mounting on DIN Track
1. Push the unit in the direction 1.
2. Lift the unit in the direction of arrow 2 while performing step (1).
Removing from DIN Track
Joining Amplifier Units
DIN track (PFP-N) is sold separately.
1. Open the protection cover.
2. Insert the sensor head, with the lock lever on its
connector area facing upward, all the way into the
connector port.
To remove it, press and hold the lock lever then pull the
sensor head out.
Mounting the Amplifier Unit
1-3
Mounting the sensor head
1-4
1. Push short the [MODE] button in [Measurement Mode].
2. OUT Selection Indicators (Output 1/Output 2) switch.
Settings
2
3
Sensor Head Display
2-2
2-6
Channel switching
(2-output type:E3C-LDA21N, E3C-LDA51N, E3C-LDA6N, E3C-LDA8N)
2-5
Minute Adjustment of Threshold Level
2-4
Smart Tuning Error
Error / Display Cause Remedy
Near Error
Over Error
Low Error Incident light level
is too low.
The light level
difference between
Points 1 and 2 are
extremely small.
Threshold set by
the tuning is too
high.
• Lower the power tuning level or the percentage
tuning level.
• Move the Sensor Head closer to the sensing
object.
• Increase the percentage tuning level.
2-point Tuning Received light intensity setting: Adjust the higher one out of Point 1 and Point 2 to the power tuning level.
Threshold setting: Set to the middle between Point 1 and Point 2 received light intensity values.
Received light intensity setting: Adjust the maximum received light amount when the button is pressed to the power tuning level.
Threshold setting: Set to the middle between the maximum and minimum received light amount values when the button is pressed.
Received light intensity setting: Adjust the received light amount without workpiece to the power tuning level.
Threshold setting: Light intensity level that has been set according to the setting above x (1 + Percentage tuning level)
Received light intensity setting: Adjust the received light amount when the button is pressed to the power tuning level.
Threshold setting: Not changed.
Full Auto Tuning
Percentage Tuning
Power Tuning
Basic Setting
Adjusting with a Passing Workpiece
Detecting a Transparent or Microscopic Object (Setting a Threshold with Received Light Intensity Ratio)
Restoring the Received Light Intensity Weakened due to Dust or Dirt / Restoring the Saturated Received Light Intensity
Execution can be done even if the order of workpiece
exists/not exist is reversed.
When percent tuning setting is ON, only power tuning can
be performed.
Other tunings cannot be performed.
L/D switching can be performed on Output 2 as well. (Refer to 2-3)
In the case of a 2-output type, the operation indicator on Sensor Head
Display turns ON when Output, whose OUT Selection Indicator is lit up,
is ON. (Refer to 2-5)
Hold the key for high-speed level
adjustment.
Blocking ON or Unblocking ON can be set on output 1 and 2 individually.
+: Press both
Refer to " Convenient
Setting Features".
Press button.
L/D
Set to "Light ON" to turn the output ON with a workpiece in the detection area.
[L/D Indicator] turns ON.
Set to "Dark ON" to turn ON the output without a sensing object
[L/D Indicator] turns ON.
Press button to adjust
the threshold level.
UP/DOWN
OUT Selection Indicator switches to switch the settings.
Setting and Display Overview
2-1 Output switching
2-3
Smart Tuning [Easy Sensitivity Setting]
Diffuse reflection: Perform tuning with the presence of a
sensing object.
Regressive reflection: Perform tuning without the
presence of a sensing object.
• Change the detection function to the mode of
slower response time.
• Move the Sensor Head closer to the sensing
object.
Refer to " Detailed Settings".
5
Protective Label
Power Supply
Connecting Terminal
DIN Track
Tighten the screw
while pressing
the End Plate.
Sensor Head Connection Side Hook
3
A
B
45
1
2
Lock Lever
Connector cover:
Transparent
1
2
err
err
err
Workpiece is present
Setting is Completed
Setting is Completed
Setting is Completed
Setting is Completed
2000
Hold for 3 seconds or longer
Workpiece is absent
Workpiece is absent
Percentage tuning setting
ON per
Hold both for 1 sec. or longer
1pnt
2000
2000
1500
1500
2pnt
Workpiece
Release the button when the workpiece passed through.
+
Moving the finger off the button displays "2Pnt".
Workpiece is
present
Hold for 1 seconds or longer
OUT Selection Indicator (Output 1)
[Output 1]
OUT Selection Indicator
(Output 2) Push short the [MODE] button in
[Measurement Mode].
[Output 2]
L/D
MODE
UP/DOWN
UP
Workpiece
ON
OFF
ON
OFF
Output
for Light-on
Output
for Dark-on
The threshold level
becomes higher. The threshold level
becomes lower.
The green digital
value changes.
Switches between SET mode and
RUN mode by a long press (3 seconds
or longer) of the key. If Push short,
OUT is switched (2 outputs)
A single press
switches between
Light ON/Dark ON.
[L/D] Indicator changes.
Performs tuning and
[ST Indicator] turns ON.
Threshold
Level
Green Digital
Display
Incident Light
Level
White Digital
Display
Sensitivity Setting
[S.TUNE] Button Minute Threshold
Adjustment
[UP/DOWN] Button
Mode/OUT Switch
[MODE] Button Output Switch
[L/D] Button
Setting
Reset
Zero Reset
Key Lock
[LD ON Indicator: Green]
Illuminates when the laser emission is ON.
[Operation Indicator: Orange]
Turns ON when Output is ON.
[OUT Selection Indicators: Orange]
E3C-LDA21N, E3C-LDA51N,
E3C-LDA6N, E3C-LDA8N
[OUT Indicator: Orange]
Turns ON when Output is ON.
[OUT Indicator:
Orange]
[DPC Indicator: Green]
Turns ON when Dynamic Power
Control is effective.
[ST Indicator: Blue]
Lit up when the smart tuning function is performed.
Put out when the detection function is changed
or the settings are initialized.
[L/D Indicator: Orange]
Displays Light ON/Dark ON setting.
E3C-LDA21N/LDA6N (NPN) E3C-LDA51N/LDA8N (PNP)
E3C-LDA7N (NPN) E3C-LDA9N (PNP)
12 to 24 VDC
0V
Brown
Pink *1
Blue
Black:
Control Output 1
Orange:
Control Output 2
12 to 24 VDC
0V
Brown
Pink *2
Blue
Black:
Control Output 1
Orange:
Control
Output 2
12 to 24 VDC
0V
External Input
External Input
External
Input
Brown
Orange
Blue
Black:
Control Output
External
Input
12 to 24 VDC
0V
Brown
Orange
Blue
Black:
Control Output
Sensor Main Circuit Sensor Main Circuit
Overcurrent Protection Circuit
Sensor Main Circuit Sensor Main Circuit
Overcurrent Protection Circuit Overcurrent Protection Circuit
Overcurrent Protection Circuit
Load
Load Load
Load
Load Load
<Wire-saving Connector Type>
<Pre-wired Type>
Optical
communication
position
Mounting bracket
E39-L143 (sold separately)
167.8 (Max. with the protective cover open)
114 (Max. with the protective cover open)
2.6
3.9
5
30.2
13
10
27.8
4.2
10
(13)
12.7
3.4
33.5
(37)
(20.5)
16
32.1
(9.4)
(49.5) 83.4
4.3
4 dia.
19.2
5.2
170°(Max. with the protective cover open)
Unit: mm
Up to 16 Amplifier Units can be joined. Under environments
such as vibration, use an End Plate even with a single amplifier
unit. If mounting the product without joining the amplifier unit,
seal the side optical communication part with lightproof tape.
• Do not touch the emitter and receiver areas of the
sensor head. A fingerprint may prevent proper
measurement.
If you accidentally touch it, use a soft cloth to wipe
it out.
• Fix the connector area so that it should not be
affected by oscillation and impact.
1. Mount the Amplifier Units one at a time onto the DIN track.
2. When using a wire-saving connector, mount the master
connector to A and slave connector to B.
3. Slide the Amplifier Unit until the Amplifier Unit is closely
attached.(Arrow 3) (For the wire-saving connector type, be sure
that a master connector and a slave connector, or a slave
connector and a slave connector are connected.)
4. Use End Plates (PFP-M: separately sold) at the both ends of the
grouped Amplifier Units to prevent them from separating due to
vibration or other cause.(Arrow 4)
5. Tighten the screw on the End Plates using a driver.(Arrow 5)
During or directly after the following operation, tuning cannot be executed.
Wait for a while before executing tuning.
Operation disabling tuning: tuning, setting initialization, emission OFF
For Output 2, light intensity is not adjusted during tuning. To adjust light intensity to the power tuning level, switch to Output 1. (Only the model with two-output type)
E3C-LDAN Series
Key Lock Function Disables all the button operations.
Preventing Malfunction
Enable/Cancel
(The same procedure)
Zero Reset Function
Returning Received Light Intensity Display to "0"
DPC Function
For Stable Detection Regardless of Received Light Intensity Changed due to Dust or Dirt
When smart tuning is in error / output 1 is Area Detection Mode /
Detection Function is changed / power tuning adjustment
is turned OFF, the DPC function is disabled.
When the DPC function is disabled from the enabled state,
perform the tuning again or reset the threshold.
Use of the DPC function with regressive reflection model is recommended.
The zero reset is cancelled when smart tuning
is executed. Do not enable the DPC function
in the zero reset state.
Area Detection Mode
For Output When Received Light Intensity is Within the Area
1. Select [Setting Mode] - [OUT1 Mode] -
[Area Detection Mode].
Pressing the [MODE] button for 3 seconds or longer
exits the [SET mode].
2. Press the [MODE] button in [Measurement Mode] to
display "OUT1 HIGH" and "OUT1 LOW".
Green digital indicator shows HIGH and LOW.
3. Provide Smart Tuning to each of HIGH/LOW
thresholds by pressing the [S.TUNE] button.
In tuning by percent, the thresholds are set as follows:
HIGH: Received light intensity in 3. + Received light intensity in 3. × Absolute value of percent tuning level
LOW: Received light intensity in 3. - Received light intensity in 3. × Absolute value of percent tuning level
Set HIGH/LOW thresholds HIGH > LOW.
The threshold also changes accordingly.
The lower threshold limit is -1999.
The DPC indicator turns ON
when the DPC function is effective.
Convenient Setting Features
3
2
Refer to " Settings".
Maintenance
4
Problem Cause
Nothing is shown
on the indication.
The OUT indicator
blinking
Sensing / Detection
not possible despite
the minimum
threshold level
Remedy
Troubleshooting
No power supplied or the
cable broken
Mutual interference
or other reason.
Check the wiring, connector connection, power supply
voltage and power supply capacity again.
Check the Amplifier Units mounted in a group
and turn ON the power again.
Incident light level
displayed in a
negative value.
The zero reset function is
enabled.
The light intensity
level does not
change
Laser light flashes
The sensor head cable
may be disconnected or
broken.
Lost tracking of
the settings made.
Cancel the zero reset function.
Check the sensor head connection.
Reset the settings.
Laser is not emitted.
[ ] appears in
the display.
The sensor head is not
properly connected. The
external input is
short-circuited in “emission
OFF” condition.
Check the wiring and external input settings.
Wipe off any dirt on the light emitting/receiving
surface of the sensor head.
Dust or dirt influences.
Error Name / Display Cause
DPC Error *
Lock ON
EEPROM Error
* Represents a number
Remedy
Error Display
The incident light level
has deteriorated due
to dust or dirt.
The key lock
function enabled
Wipe the dust off the sensor head detection surface
or other relevant areas and recover the original
incident light level. Then, perform Smart Tuning.
Cancel the key lock function.
Load short circuit detection error
* The DPC indicator blinks.
Overcurrent is carried
to the control output. Check wiring and connector connection again.
Turn ON the power again. Reset the settings if the
error is not corrected. If the problem still remains,
replace the amplifier unit; this is memory
malfunction such as rewritable time exceedance.
Failed internal data
read/out.
Refer to "1-2 Input/Output Circuit Diagram"
Refer to "2-6 Smart Tuning "
Refer to " Convenient Setting Features"
Refer to " Detailed Settings".
Refer to "1-3 Mounting Amplifier Unit"
Refer to " Convenient Setting Features"
Refer to "1-2 Input/Output Circuit Diagram"
and "4-2 Ratings and Specifications"
Refer to " Convenient Setting Features"
Refer to "1-4 Mounting the sensor head"
Refer to "1-2 Input/Output Circuit Diagram"
---
Troubleshooting
4-1
5
Refer to " Detailed Settings".
5
3
3
3
Refer to " Convenient Setting Features"
3
A
B
Hold button for 3 seconds or longer to enter SET mode.
1. Function Selection Enabling 6 to 16
10. External Input A type of external input is changed. (Only the model with External Input type)
11. Digital Display
Changing Digital Display in RUN Mode for Specific Purpose
12. Inverted Display Mounting Amplifier in Inverted Direction
13. Hysteresis width
14. Writing to EEPROM of External Input (Only the model with External Input type)
2.
Detection Function
Changing Incident Light Level and Response Time
3. DPC Function Stable Detection Regardless of Incident Light Level Change
4. Timer Function Setting Output Timer (Two outputs are displayed for the two-output type)
5. Power Tuning Level Changing the Target Incident Light Level (Power Tuning Level)
7. Percentage Tuning
Detecting Transparent or Small Workpiece (Two outputs are displayed for the two-output type)
6. Power Tuning ON/OFF Setting To Turn ON/OFF the Light Amount Adjustment at Tuning
8. Output 1 Mode Output mode for the output 1 is changed.
9. Output 2 Mode Output mode for the output 2 is changed. (Only the model with two-output type)
Detection function
HSSTND GIGA SHS
Response time
250 μs1 ms 4 ms 80 μs
A
(Two outputs are displayed for the two-output type)
Detailed Settings
5
Setting Reset Initialize all settings to the factory-set defaults.
Initializing Settings
* Press either of [UP] / [DOWN].
Contact input (Relay or switch)
ON: Short circuit to 0V (Outflow current: 1 mA max.)
OFF: Open or short circuit to Vcc
ON: Short circuit to Vcc (Sink current: 3mA max.)
OFF: Open or short circuit to 0V
NPN output
PNP output
ON: 1.5 V max. (Outflow current: 1 mA max.)
OFF: Vcc-1.5 V to Vcc (Leakage current: 0.1 mA max.)
ON: Vcc-1.5 V to Vcc (Sink current: 3 mA max.)
OFF: 1.5 V max. (Leakage current: 0.1 mA max.)
ON: 9 ms min.
OFF: 20 ms min.
Non-contact input (Transistor) Input time *1-1
*1. Details on external inputs are as follows:
*1-1 Input time is 25 ms or more for both ON/OFF only when tuning (tUnE) is selected in the external input.
*2.
Separately purchase the E3X-CN21 Master Connector (4-conductor) when using this product as a single unit or as
a master unit, or the E3X-CN22 Slave Connector (2-conductor) when using as a slave unit. Either Connector can be used.
*3. Even if tuning is implemented, the number of units will not change.
In standard mode and giga mode, set the threshold level to 400 or more.
Surrounding air
Temperature range
Ratings and Specifications
4-2
Model
Control output
External input *1
Connection method *2
Power supply voltage
Power consumption
Control output
Protection circuit
Maximum connectable Units
Ambient humidity range
Altitude
Installation environment
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Weight (packed state/sensor)
Materials
Applicable sensor head
NPN output
PNP output
Super-high-speed
mode (SHS)
High-speed mode (HS)
Standard mode (Stnd)
Giga mode (GIGA)
E3C-LDA21N
E3C-LDA51N
E3C-LDA6N
E3C-LDA8N
E3C-LN
E3C-LDA7N
E3C-LDA9N
2
1
Pre-wired type
12 to 24 VDC ±10%, ripple (p-p) 10% max.
Power consumption: 1080 mW max.
(when the power supply voltage is 24 V, the current consumption is 45 mA max.)
Load power supply voltage: 26.4 VDC, open collector output type (depends on the NPN/PNP output)
Load current: 100 mA max. for 1 to 3 units use, 20 mA max. for 4 or more units joined.
Residual voltage: Load current less than 10 mA: 1 V max., load current 10 to 100 mA: 2 V max.
Off-state current: 0.1 mA max.
Power supply reverse polarity protection, output short-circuit protection and
output incorrect connection protection
16 units
0 (The communication and mutual interference prevention functions are disabled
if the SHS mode is selected for detection function.)
10 units
10 units
10 units
Operating: 1 to 2 amplifiers connected: -25℃ to 55℃, 3 to 10 amplifiers connected: -25℃ to 50℃,
11 to 16 amplifiers connected: -25℃ to 45℃
Storage: -30℃ to 70℃ (with no icing or condensation)
Operating and storage: 35 to 85% (with no condensation) within the surrounding
air temperature range shown above
2000m max.
Pollution degree 3 (as per IEC60947-1)
20 MΩ min. (at 500 VDC)
1,000 VAC, 50/60 Hz, 1 minute
10 to 55 Hz with a 1.5mm double amplitude for 2 hrs each in X, Y and Z directions
500 m/s2, for 3 times each in X, Y and Z directions
Approx. 115 g/Approx. 75 g
Case and cover: Polycarbonate (PC), Cable covering: PVC
2
0
Wire-saving connector type
1
1
Number of
units for mutual
interference
prevention *3
Approx. 60 g/Approx. 20 g
*1, *2, *3
3
Refer to " Convenient Setting Features
DPC Function".
Hi
Lo
ON
OFF
ON
OFF
Control output
for Light-on
Control output
for Dark-on
Hold both for 3 sec. or longer
Time
Internal Incident Light Level
Incident Light
Level
Threshold
Level
Stabilizes the displayed
incident level by
correcting internal
incident level changes.
Displayed Incident
Light Level
Smart Tuning SET mode
Run Select
DPC Function
ON
0
2000
Hold both for 3 sec.
or longer Hold both for 3 sec.
or longer
60004000
Enable Cancel
Hold both for 3 sec. or longer
2000
4000
e-st
e-me
*
MODE
hs
func
2000
UP/DOWN
UP/DOWN
(Incident Light Level Example)
dflt
MODE
MODE
MODE
MODE
MODE
STND Standard
Mode shs
2000
SHS Super High-speed Mode
2000
GIGA Giga Mode HS High-speed Mode
Basic setting
Detailed setting
The OUT Selection Indicators show items
for Output1/Output 2 individually for each output.
func
Off-delay Timer
Holds the output ON for
detection by PLC when
the detection time is too
short.
On-delay Timer
Delays the output ON
after detection.
(a)
(b)
One-shot Timer
Keeps the output ON for
a specified time regardless
of the workpiece size
variations.
(c)
dpc
%n
dpc
%ff
----
2000
per
%ff
per
%n
UP/DOWN
UP/DOWN
UP/DOWN
%n-d
Function Selection: [ ]
Function Selection: [ ]
(a)Off-delay Timer
Time Off
(b)On-delay Timer (c)One shot
DPC ON
DPC OFF
ptun
%n
ptun
%ff
UP/DOWN
Power tuning adjustment OFF
Power tuning
adjustment ON
Percentage tuning ON
Percentage tuning
OFF
std
UP/DOWN
Normal detection
mode
std
alrm
UP/DOWN
Alarm output mode
err
Error output mode
Normal detection
mode
fd
f
UP/DOWN
Use button to set the power tuning level.
(100 to 9999 in 1 steps; the initial value: 2000)
UP/DOWN
use button to set the power tuning level.
(1 to 9999ms in 1ms steps; the initial value: 10ms)
Press button in [ ] menu, then use
button to set the percentage tuning level.
(-99% to 99% in 1% steps; the initial value: -6%)
MODE
UP/DOWN
When output 2 is set to alarm or error
output mode, the output 2 cannot be
selected in measurement mode.
area
Area detection mode
Alarm Output Mode: After pressing the button,
press the button to set alarm output level.
(0 to 100p in 1p steps; the initial value: 50p)
On-delay of 300 ms is applied.
When smart tuning is performed,
the power tuning level is the reference value.
When smart tuning is not performed,
received light intensity 9999 is the reference value.
Error output mode: Output when a DPC error
or EEPROM error occurs.
MODE
UP/DOWN
MODE
After pressing the button,
h
%ff
UP/DOWN
husr
79
79
UP/DOWN
Move to Detection Mode by holding the button for 3 seconds or longer.
std
p-b bar
UP/DOWN
hstd
Threshold/Receiving
light amount
Normal
Reverse
Standard
setting
User setting
(a)To see the reserve of the light
intensity level for the threshold
(b)To set the threshold with a
microscopic object or fast-moving object
(c)To see the intuitive and
easy to follow display
(d)To adjust the beam
(e)To know the CH number when two
or more units connected
tune ptun
UP/DOWN
Input OFF
Tuning Power tuning Emission OFF Zero reset
0rst
%ff
150p
3000
3500
3000
2000
8000
per
The display reverses.
Threshold and light intensity are displayed on
green digital and white digital respectively.
%n
UP/DOWN
ON
OFF
The settings that have been changed by an external input
with "oFF" will not be overwritten to prevent EEPROM
from reaching its lifespan (100,000 writings).
(a)
(b)
(c)
(d)
(e)
(Reference value)
ch
2000
Be sure to check the stability of outputs
as there is a possibility of chattering.
MODE
UP/DOWN
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
The hysteresis width can be set by pressing the button in the menu
of "husr" and then pressing the button. (0 to 9999, increments of 1)
Point 1
Less than 3 sec.
3 sec. or longer
2-point tuning
Full Auto Tuning
Point 2
Less than 3 sec.
-
External input setting: Tuning starts with the signal input time of 25 ms or more during power tuning.
Threshold
Received light intensity ratio
Peak receiving light amount Bottom receiving light amount
Threshold
120% 100% 80%
Peak receiving light amount Receiving light amount
CH number
Receiving light amount
B
A
*1. The signal input time is as follows:
*2. When performing a percentage tuning on the external input, turn it ON as described in “7. Percentage Tuning Setting”
*3. When changing the type of external input, release the external input signal before changing it.
SET mode provides the following function settings. The initial display
shown after transition from one function to another represents the
factory default.
T
T
No Incident Light
Incident Light
ON
OFF
ON
OFF
L-ON
D-ON
T
T
No Incident Light
Incident Light
ON
OFF
ON
OFF
L-ON
D-ON
No Incident Light
Incident Light
T
T
ON
OFF
ON
OFF
L-ON
D-ON
Set the hysteresis width by initial value. Hysteresis width is provided for threshold to
prevent the judgment output from becoming unstable near the boundaries.
External input setting: tuning
External input setting: At the time of zero reset
External input setting: Operation starts with the signal input time of 25 ms
or more with emitter OFF, and stops by releasing the signal.
MODE
[ ]
UP/DOWN
n t n% %
[ ]
yes
stnd
2000
Zero reset Enable Cancel
3s or longer
Less than 3s
· Signal input time when tuning(in tUnE)
is selected is the same as the button input time.
· Enable / Cancel of Zero reset is the timing
when input is turned off.
Suitability for Use
t
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer’s application or use of the Product. At Buyer’s request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND
THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED
FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR
SYSTEM.
Jun, 2019
D
OMRON Corporation Industrial Automation Company
Contact: www.ia.omron.com
Kyoto, JAPAN
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
Regional Headquarters
E3C-LDA N
©
OMRON Corporation 2022 All Rights Reserved.
E3C-LDA N
1
1-1
1-2
1-3
1-4
2
2-32-1
2-2
2-6
2-5
2-4
L/D
UP/DOWN
err
err
err
2000
per
1pnt
2000
2000
1500
1500
2pnt
L/D
MODE
UP/DOWN
UP
E3C-LDA N
4
4-24-1
53
2000
4000
e-st
e-me
MODE
hs
func
2000
UP/DOWN
UP/DOWN
dflt
MODE
MODE
MODE
MODE
MODE
stnd
shs
2000
2000
2000
func
dpc
%n
dpc
%ff
----
2000
per
%ff
per
%n
UP/DOWN
UP/DOWN
UP/DOWN
%n-d
ptun
%n
ptun
%ff
UP/DOWN
std
UP/DOWN
std
alrm
UP/DOWN
err
fd
f
UP/DOWN 100 9999 2000
UP/DOWN 1 9999 10
MODE
UP/DOWN
area
MODE
UP/DOWN
MODE
h
%ff
UP/DOWN
husr
79
79
UP/DOWN
std
p-b bar
UP/DOWN
hstd
tune ptun
UP/DOWN
0rst
%ff
150p
3000
3500
3000
2000
8000
per
%n
UP/DOWN
ch
2000
MODE
UP/DOWN
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
husr
0
2000 60004000
MODE
UP/DOWN
n t n% %
yes
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4