E3C-LDAN Series
● Key Lock Function Disables all the button operations.
Preventing Malfunction
Enable/Cancel
(The same procedure)
● Zero Reset Function
Returning Received Light Intensity Display to "0"
● DPC Function
For Stable Detection Regardless of Received Light Intensity Changed due to Dust or Dirt
When smart tuning is in error / output 1 is Area Detection Mode /
Detection Function is changed / power tuning adjustment
is turned OFF, the DPC function is disabled.
When the DPC function is disabled from the enabled state,
perform the tuning again or reset the threshold.
Use of the DPC function with regressive reflection model is recommended.
The zero reset is cancelled when smart tuning
is executed. Do not enable the DPC function
in the zero reset state.
● Area Detection Mode
For Output When Received Light Intensity is Within the Area
1. Select [Setting Mode] - [OUT1 Mode] -
[Area Detection Mode].
Pressing the [MODE] button for 3 seconds or longer
exits the [SET mode].
2. Press the [MODE] button in [Measurement Mode] to
display "OUT1 HIGH" and "OUT1 LOW".
Green digital indicator shows HIGH and LOW.
3. Provide Smart Tuning to each of HIGH/LOW
thresholds by pressing the [S.TUNE] button.
In tuning by percent, the thresholds are set as follows:
HIGH: Received light intensity in 3. + Received light intensity in 3. × Absolute value of percent tuning level
LOW: Received light intensity in 3. - Received light intensity in 3. × Absolute value of percent tuning level
Set HIGH/LOW thresholds HIGH > LOW.
The threshold also changes accordingly.
The lower threshold limit is -1999.
The DPC indicator turns ON
when the DPC function is effective.
Convenient Setting Features
3
2
Refer to " Settings".
Maintenance
4
Problem Cause
Nothing is shown
on the indication.
The OUT indicator
blinking
Sensing / Detection
not possible despite
the minimum
threshold level
Remedy
● Troubleshooting
No power supplied or the
cable broken
Mutual interference
or other reason.
Check the wiring, connector connection, power supply
voltage and power supply capacity again.
Check the Amplifier Units mounted in a group
and turn ON the power again.
Incident light level
displayed in a
negative value.
The zero reset function is
enabled.
The light intensity
level does not
change
Laser light flashes
The sensor head cable
may be disconnected or
broken.
Lost tracking of
the settings made.
Cancel the zero reset function.
Check the sensor head connection.
Reset the settings.
Laser is not emitted.
[ ] appears in
the display.
The sensor head is not
properly connected. The
external input is
short-circuited in “emission
OFF” condition.
Check the wiring and external input settings.
Wipe off any dirt on the light emitting/receiving
surface of the sensor head.
Dust or dirt influences.
Error Name / Display Cause
DPC Error *
Lock ON
EEPROM Error
* Represents a number
Remedy
● Error Display
The incident light level
has deteriorated due
to dust or dirt.
The key lock
function enabled
Wipe the dust off the sensor head detection surface
or other relevant areas and recover the original
incident light level. Then, perform Smart Tuning.
Cancel the key lock function.
Load short circuit detection error
* The DPC indicator blinks.
Overcurrent is carried
to the control output. Check wiring and connector connection again.
Turn ON the power again. Reset the settings if the
error is not corrected. If the problem still remains,
replace the amplifier unit; this is memory
malfunction such as rewritable time exceedance.
Failed internal data
read/out.
Refer to "1-2 Input/Output Circuit Diagram"
Refer to "2-6 Smart Tuning "
Refer to " Convenient Setting Features"
Refer to " Detailed Settings".
Refer to "1-3 Mounting Amplifier Unit"
Refer to " Convenient Setting Features"
Refer to "1-2 Input/Output Circuit Diagram"
and "4-2 Ratings and Specifications"
Refer to " Convenient Setting Features"
Refer to "1-4 Mounting the sensor head"
Refer to "1-2 Input/Output Circuit Diagram"
---
Troubleshooting
4-1
5
Refer to " Detailed Settings".
5
3
3
3
Refer to " Convenient Setting Features"
3
A
B
Hold button for 3 seconds or longer to enter SET mode.
1. Function Selection Enabling 6 to 16
10. External Input A type of external input is changed. (Only the model with External Input type)
11. Digital Display
Changing Digital Display in RUN Mode for Specific Purpose
12. Inverted Display Mounting Amplifier in Inverted Direction
13. Hysteresis width
14. Writing to EEPROM of External Input (Only the model with External Input type)
2.
Detection Function
Changing Incident Light Level and Response Time
3. DPC Function Stable Detection Regardless of Incident Light Level Change
4. Timer Function Setting Output Timer (Two outputs are displayed for the two-output type)
5. Power Tuning Level Changing the Target Incident Light Level (Power Tuning Level)
7. Percentage Tuning
Detecting Transparent or Small Workpiece (Two outputs are displayed for the two-output type)
6. Power Tuning ON/OFF Setting To Turn ON/OFF the Light Amount Adjustment at Tuning
8. Output 1 Mode Output mode for the output 1 is changed.
9. Output 2 Mode Output mode for the output 2 is changed. (Only the model with two-output type)
Detection function
HSSTND GIGA SHS
Response time
250 μs1 ms 4 ms 80 μs
A
(Two outputs are displayed for the two-output type)
Detailed Settings
5
● Setting Reset Initialize all settings to the factory-set defaults.
Initializing Settings
* Press either of [UP] / [DOWN].
Contact input (Relay or switch)
ON: Short circuit to 0V (Outflow current: 1 mA max.)
OFF: Open or short circuit to Vcc
ON: Short circuit to Vcc (Sink current: 3mA max.)
OFF: Open or short circuit to 0V
NPN output
PNP output
ON: 1.5 V max. (Outflow current: 1 mA max.)
OFF: Vcc-1.5 V to Vcc (Leakage current: 0.1 mA max.)
ON: Vcc-1.5 V to Vcc (Sink current: 3 mA max.)
OFF: 1.5 V max. (Leakage current: 0.1 mA max.)
ON: 9 ms min.
OFF: 20 ms min.
Non-contact input (Transistor) Input time *1-1
*1. Details on external inputs are as follows:
*1-1 Input time is 25 ms or more for both ON/OFF only when tuning (tUnE) is selected in the external input.
*2.
Separately purchase the E3X-CN21 Master Connector (4-conductor) when using this product as a single unit or as
a master unit, or the E3X-CN22 Slave Connector (2-conductor) when using as a slave unit. Either Connector can be used.
*3. Even if tuning is implemented, the number of units will not change.
In standard mode and giga mode, set the threshold level to 400 or more.
Surrounding air
Temperature range
Ratings and Specifications
4-2
Model
Control output
External input *1
Connection method *2
Power supply voltage
Power consumption
Control output
Protection circuit
Maximum connectable Units
Ambient humidity range
Altitude
Installation environment
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Weight (packed state/sensor)
Materials
Applicable sensor head
NPN output
PNP output
Super-high-speed
mode (SHS)
High-speed mode (HS)
Standard mode (Stnd)
Giga mode (GIGA)
E3C-LDA21N
E3C-LDA51N
E3C-LDA6N
E3C-LDA8N
E3C-LN
E3C-LDA7N
E3C-LDA9N
2
1
Pre-wired type
12 to 24 VDC ±10%, ripple (p-p) 10% max.
Power consumption: 1080 mW max.
(when the power supply voltage is 24 V, the current consumption is 45 mA max.)
Load power supply voltage: 26.4 VDC, open collector output type (depends on the NPN/PNP output)
Load current: 100 mA max. for 1 to 3 units use, 20 mA max. for 4 or more units joined.
Residual voltage: Load current less than 10 mA: 1 V max., load current 10 to 100 mA: 2 V max.
Off-state current: 0.1 mA max.
Power supply reverse polarity protection, output short-circuit protection and
output incorrect connection protection
16 units
0 (The communication and mutual interference prevention functions are disabled
if the SHS mode is selected for detection function.)
10 units
10 units
10 units
Operating: 1 to 2 amplifiers connected: -25℃ to 55℃, 3 to 10 amplifiers connected: -25℃ to 50℃,
11 to 16 amplifiers connected: -25℃ to 45℃
Storage: -30℃ to 70℃ (with no icing or condensation)
Operating and storage: 35 to 85% (with no condensation) within the surrounding
air temperature range shown above
2000m max.
Pollution degree 3 (as per IEC60947-1)
20 MΩ min. (at 500 VDC)
1,000 VAC, 50/60 Hz, 1 minute
10 to 55 Hz with a 1.5mm double amplitude for 2 hrs each in X, Y and Z directions
500 m/s2, for 3 times each in X, Y and Z directions
Approx. 115 g/Approx. 75 g
Case and cover: Polycarbonate (PC), Cable covering: PVC
2
0
Wire-saving connector type
1
1
Number of
units for mutual
interference
prevention *3
Approx. 60 g/Approx. 20 g
*1, *2, *3
3
Refer to " Convenient Setting Features
● DPC Function".
Hi
Lo
ON
OFF
ON
OFF
Control output
for Light-on
Control output
for Dark-on
Hold both for 3 sec. or longer
Time
Internal Incident Light Level
Incident Light
Level
Threshold
Level
Stabilizes the displayed
incident level by
correcting internal
incident level changes.
Displayed Incident
Light Level
Smart Tuning SET mode
Run Select
DPC Function
ON
0
2000
Hold both for 3 sec.
or longer Hold both for 3 sec.
or longer
60004000
Enable Cancel
Hold both for 3 sec. or longer
2000
4000
e-st
e-me
*
MODE
hs
func
2000
UP/DOWN
UP/DOWN
(Incident Light Level Example)
dflt
MODE
MODE
MODE
MODE
MODE
STND Standard
Mode shs
2000
SHS Super High-speed Mode
2000
GIGA Giga Mode HS High-speed Mode
Basic setting
Detailed setting
The OUT Selection Indicators show items
for Output1/Output 2 individually for each output.
func
Off-delay Timer
Holds the output ON for
detection by PLC when
the detection time is too
short.
On-delay Timer
Delays the output ON
after detection.
(a)
(b)
One-shot Timer
Keeps the output ON for
a specified time regardless
of the workpiece size
variations.
(c)
dpc
%n
dpc
%ff
----
2000
per
%ff
per
%n
UP/DOWN
UP/DOWN
UP/DOWN
%n-d
Function Selection: [ ]
Function Selection: [ ]
(a)Off-delay Timer
Time Off
(b)On-delay Timer (c)One shot
DPC ON
DPC OFF
ptun
%n
ptun
%ff
UP/DOWN
Power tuning adjustment OFF
Power tuning
adjustment ON
Percentage tuning ON
Percentage tuning
OFF
std
UP/DOWN
Normal detection
mode
std
alrm
UP/DOWN
Alarm output mode
err
Error output mode
Normal detection
mode
fd
f
UP/DOWN
Use button to set the power tuning level.
(100 to 9999 in 1 steps; the initial value: 2000)
UP/DOWN
use button to set the power tuning level.
(1 to 9999ms in 1ms steps; the initial value: 10ms)
Press button in [ ] menu, then use
button to set the percentage tuning level.
(-99% to 99% in 1% steps; the initial value: -6%)
MODE
UP/DOWN
When output 2 is set to alarm or error
output mode, the output 2 cannot be
selected in measurement mode.
area
Area detection mode
Alarm Output Mode: After pressing the button,
press the button to set alarm output level.
(0 to 100p in 1p steps; the initial value: 50p)
On-delay of 300 ms is applied.
When smart tuning is performed,
the power tuning level is the reference value.
When smart tuning is not performed,
received light intensity 9999 is the reference value.
Error output mode: Output when a DPC error
or EEPROM error occurs.
MODE
UP/DOWN
MODE
After pressing the button,
h
%ff
UP/DOWN
husr
79
79
UP/DOWN
Move to Detection Mode by holding the button for 3 seconds or longer.
std
p-b bar
UP/DOWN
hstd
Threshold/Receiving
light amount
Normal
Reverse
Standard
setting
User setting
(a)To see the reserve of the light
intensity level for the threshold
(b)To set the threshold with a
microscopic object or fast-moving object
(c)To see the intuitive and
easy to follow display
(d)To adjust the beam
(e)To know the CH number when two
or more units connected
tune ptun
UP/DOWN
Input OFF
Tuning Power tuning Emission OFF Zero reset
0rst
%ff
150p
3000
3500
3000
2000
8000
per
The display reverses.
Threshold and light intensity are displayed on
green digital and white digital respectively.
%n
UP/DOWN
ON
OFF
The settings that have been changed by an external input
with "oFF" will not be overwritten to prevent EEPROM
from reaching its lifespan (100,000 writings).
(a)
(b)
(c)
(d)
(e)
(Reference value)
ch
2000
Be sure to check the stability of outputs
as there is a possibility of chattering.
MODE
UP/DOWN
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
The hysteresis width can be set by pressing the button in the menu
of "husr" and then pressing the button. (0 to 9999, increments of 1)
Point 1
Less than 3 sec.
3 sec. or longer
2-point tuning
Full Auto Tuning
Point 2
Less than 3 sec.
-
External input setting: Tuning starts with the signal input time of 25 ms or more during power tuning.
Threshold
Received light intensity ratio
Peak receiving light amount Bottom receiving light amount
Threshold
120% 100% 80%
Peak receiving light amount Receiving light amount
CH number
Receiving light amount
B
A
*1. The signal input time is as follows:
*2. When performing a percentage tuning on the external input, turn it ON as described in “7. Percentage Tuning Setting”
*3. When changing the type of external input, release the external input signal before changing it.
SET mode provides the following function settings. The initial display
shown after transition from one function to another represents the
factory default.
T
T
No Incident Light
Incident Light
ON
OFF
ON
OFF
L-ON
D-ON
T
T
No Incident Light
Incident Light
ON
OFF
ON
OFF
L-ON
D-ON
No Incident Light
Incident Light
T
T
ON
OFF
ON
OFF
L-ON
D-ON
Set the hysteresis width by initial value. Hysteresis width is provided for threshold to
prevent the judgment output from becoming unstable near the boundaries.
External input setting: tuning
External input setting: At the time of zero reset
External input setting: Operation starts with the signal input time of 25 ms
or more with emitter OFF, and stops by releasing the signal.
MODE
[ ]
UP/DOWN
n t n% %
[ ]
yes
stnd
2000
Zero reset Enable Cancel
3s or longer
Less than 3s
· Signal input time when tuning(in tUnE)
is selected is the same as the button input time.
· Enable / Cancel of Zero reset is the timing
when input is turned off.
Suitability for Use
t
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer’s application or use of the Product. At Buyer’s request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND
THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED
FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR
SYSTEM.
Jun, 2019
D
OMRON Corporation Industrial Automation Company
Contact: www.ia.omron.com
Kyoto, JAPAN
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
Regional Headquarters