2257392-0A
② ①
③ ④
(1) Do not use in following ambience.
①Direct sunlight, rain, snow, and waterdrop.
②Chemicals, especially solvents and acids.
③Corrosive gas, erosive gas.
(2) Please note that this sensor might malfunction when using it
near the ultrasonic cleansing apparatus that generates the high
frequency electric field, the high frequency generation device,
the transceiver, the cellular phone, and the inverter, etc.
Please refer to Sensor General Catalogue for typical measures.
(3) Plumbing into the same pipe or duct with high-voltage line or
power line may cause a malfunction, or destruction because
of induction.
(4) Do not use thinner may dissolve the surface of products.
Table 2 (mm)
(Shielded) (Non Shielded)
Table 1 (mm)
When installing two or more proximity sensors face to face or side by
side, ensure that the minimum distances given in the Table2 maintained.
Table 4 (mm)
Size
FG
M8
M12
M18
M30
8.5
12.5
18.5
30.5
13
17
24
36
When mounting the proximity sensor within a metal panel, ensure that
the clearances given in the Table1 are maintained. Failure to maintain
these distance may cause deterioration in the performance of the sensor.
M8
Size
Type
Model E2B-( )
M12
0
8
0
4.5
12
Table 3
Size
M8
M12
M18
M30
M1:
Thank you for selecting OMRON product.This sheet pri-
marily describes precautions required in installing and
operating the product.
Before operating the product,read the sheet thoroughly to
acquire sufficient knowledge of the product.For your con-
venience,keep the sheet at your disposal.
The following notice applies only to products that carry the CE mark:
Notice:
This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take adequate
measures to reduce interference.
Manufacturer:
Omron Corporation,
Shiokoji Horikawa, Shimogyo-ku,
Kyoto 600-8530 JAPAN
Shanghai Factory
No.789 Jinji Road,
Jinqiao Export Processing District,
Pudong New Area,Shanghai,201206 CHINA
TRACEABILITY INFORMATION:
Representative in EU:
Omron Europe B.V.
Wegalaan 67-69
2132 JD Hoofddorp,
The Netherlands
M18 M30
0
12
0
8
18
0
18
0
20
27
0
30
0
40
45
0
8
0
4.5
12
2.4
18
2.4
12
18
3.6
27
3.6
24
27
6
45
6
45
45
Torque
7N·m
12N·m
30N·m
50N·m
Keep following item to secure from danger.
(1) Do not use in ambience of flammable, voltatile gas.
(2) Do not decompose, repair, and modify.
(3)
The product may explode or be damaged with following misusages.
①To apply excess voltage as the power source.
②To short-circuit the load.
③To reverse polarity, or to miss-wire.
④To connect power source without load.
(4) Please process it as industrial waste.
Indicates a potentially hazardous situation
which,if not avoided, will result in minor or
moderate injury or may result in serious
injury or death.Additionally there may be
significant property damage.
main
circuit
①
10 to 30VDC
NO/NC type:④
Brown
Black
Blue
E2B-S08□-MC-B/C□
load
E2B-□-□-B□
④
① ③
MC:
Power supply voltage 10 to 30 VDC (including 10% ripple(p-p))
Current consumption 10mA max.
Load current 200mA max. ※
Residual voltage 2V max.(under load current of 200mA with cable length of 2m)
Operation mode -B1/-C1 models: NO ; -B2/-C2 models: NC
Indicator Operation indicator yellow LED
Ambient air temperature Operation & Storage: -25 to 70℃(with no icing or condensation)
Ambient humidity Operation & Storage: 35% to 95%RH
Standard and listing IP67
Non Shielded
Shielded
1.5mm
0 to 1.2mm
□8×1mm
2,000Hz
M8 M12
Size
Type
Model E2B-( )
Sensing
distance(±10%)
Setting
distance
Differential
travel
Standard target
(Iron)
Response
frequency
2.0mm
0 to 1.6mm
□8×1mm
1,500Hz
2.0mm
0 to 1.6mm
□8×1mm
1,000Hz
4.0mm
0 to 3.2mm
□12×1mm
1,000Hz
2.0mm
0 to 1.6mm
□12×1mm
1,500Hz
4.0mm
0 to 3.2mm
□12×1mm
1,000Hz
5.0mm
0 to 4mm
□15×1mm
800Hz
8.0mm
0 to 6.4mm
□24×1mm
800Hz
Non Shielded
Shielded
10% max. of sensing distance
Non Shielded
Shielded
5.0mm
0 to 4mm
□18×1mm
600Hz
M18 M30
8.0mm
0 to 6.4mm
□24×1mm
500Hz
10.0mm
0 to 8mm
□30×1mm
400Hz
16.0mm
0 to 12.8mm
□48×1mm
400Hz
10.0mm
0 to 8mm
□30×1mm
400Hz
15.0mm
0 to 11.25mm
□45×1mm
250Hz
20.0mm
0 to 16mm
□60×1mm
100Hz
30.0mm
0 to 22.5mm
□90×1mm
100Hz
Non Shielded
Shielded
main
circuit
Brown
Black
Blue
①
10 to 30VDC
③
S08□S01
Shielded
S08□N02 M12□S02 M18□S05 M30□S10
S08□S02 M12□S04 M18□S08 M30□S15
M12□N05 M18□N10 M30□N20
S08□N04 M12□N08 M18□N16 M30□N30
S08□S01 S08□S02 S08□N02 S08□N04 M12□S02 M12□S04 M12□N05 M12□N08 M18□S05 M18□N10 M18□N16 M30□S10 M30□S15 M30□N20 M30□N30
※
※
M18□S08
④or②
E2B-□-□-C□※
④or②
Non Shielded Shielded Non Shielded
6
24
6
8
24
12
24
12
8
24
15
40
15
20
36
15
40
15
20
40
Shielded Non Shielded
22
55
22
40
54
25
70
25
48
70
30
90
30
70
90
45
140
45
90
140
Shielded Non Shielded
Do not tighten the sensor mounting nuts with excessive force.
M8
Size
Type
Model E2B-( )
M12
20
15
M18 M30
30
20
50
35
100
70
80
60
120
100
60
35
110
90
S08□S01
Shielded
S08□N02 M12□S02 M18□S05 M30□S10
S08□S02 M12□S04 M18□S08 M30□S15
M12□N05 M18□N10 M30□N20
S08□N04 M12□N08 M18□N16 M30□N30
Non Shielded Shielded Non Shielded
20
15
80
60
30
20
120
100
Shielded Non Shielded
200
110
200
120
300
200
350
300
Shielded Non Shielded
A
B
load
E2B-M12□-M1-B/C□
E2B-M18□-M1-B/C□
E2B-M30□-M1-B/C□
※
NO type:④
NC type:②
Alert statements
Risk of explosion.
Do not connect sensor to AC power supply.
d
D
m
n
※Size M8 type 60 to 70℃:100mA max.