Delta Electronics AS57BSTD クイックスタートガイド

タイプ
クイックスタートガイド

このマニュアルも適しています

English-1
Preface
Thank you for purchasing DELTAs DOP-A, AE and AS series. This quick start will be helpful in the installation,
wiring and inspection of Delta HMI. Before using the product, please read this quick start to ensure correct use.
You should thoroughly understand all safety precautions before proceeding with the installation, wiring and
operation. Place this quick start in a safe location for future reference. Please observe the following
precautions:
Install the product in a clean and dry location free from corrosive and inflammable gases or liquids.
Ensure that all wiring instructions and recommendations are followed.
Ensure that HMI is correctly connected to a ground. The grounding method must comply with the
electrical standard of the country.
Do not modify or remove wiring when power is applied to HMI.
Do not touch the power supply during operation. Otherwise, it may cause electric shock.
For the information of HMI software operation, software installation and hardware wiring, please
refer to the HMI software manual.
If you have any questions during operation, please contact our local distributors or Delta sales representative.
The content of this quick start may be revised without prior notice. Please consult our distributors or download
the most updated version at http://www.delta.com.tw/industrialautomation
.
Safety Precautions
Carefully note and observe the following safety precautions when receiving, inspecting, installing, operating,
maintaining and troubleshooting. The following words, DANGER, WARNING and STOP are used to mark
safety precautions when using the Delta’s HMI product. Failure to observe these precautions may void the
warranty!
Installation
¾ Comply with quick start for installation. Otherwise it may cause equipment damage.
¾ Do not install the product in a location that is outside the stated specification for the HMI. Failure to
observe this caution may result in electric shock, fire, or personal injury.
Wiring
¾ Connect the ground terminals to a class-3 ground (Ground resistance should not exceed 100).
Improper grounding may result in communication error, electric shock or fire.
Operation
¾ The users should use Delta Screen Editor software to perform editing in Delta's HMI product. To
perform editing and confirming HMI programs without using Delta Screen Editor software in Delta's
HMI product may result in abnormal operation.
¾ Do not modify wiring during operation. Otherwise it may result in electric shock or personal injury.
¾ Never use a hard or pointed object to hit or strike the screen as doing this may damage the screen
and let the screen has not respond at all, and then cause HMI to work abnormally..
English-2
Maintenance and Inspection
¾ Do not touch any internal or exposed parts of the HMI as electrical shock may result.
¾ Do not remove operation panel while power is on. Otherwise electrical shock may result.
¾ Wait at least 10 minutes after power has been removed before touching any HMI terminals or
performing any wiring and/or inspection as an electrical charge may still remain in the HMI with
hazardous voltages even after power has been removed.
¾ Turn the power off before changing backup battery and check system settings after finishing change.
(all data will be cleared after changing battery).
¾ Be sure the ventilation holes are not obstructed during operation. Otherwise malfunction may result
due to bad ventilation or overheating troubles.
Wiring Method
¾ Remove the terminal block from the HMI before wiring.
¾ Insert only one wire into one terminal on the terminal block.
¾ If the wiring is in error, perform the wiring again with proper tools. Never use force to remove the
terminals or wires. Otherwise, it may result in malfunction or damage.
¾ For the power line that forced to take out, ensure to check wiring again and restart.
Communication Wiring
¾ Comply with communication wiring specification for wiring.
¾ Wiring length should comply with the stated specification for the HMI.
¾ Proper grounding to avoid bad communication quality.
Installation and Storage Conditions
The product should be kept in the shipping carton before installation. In order to retain the warranty coverage,
the HMI should be stored properly when it is not to be used for an extended period of time. Some storage
suggestions are:
Store in a clean and dry location free from direct sunlight.
Store within an ambient temperature range of -20°C to +60°C (-4°F to 140°F).
Store within a relative humidity range of 10% to 90% and non-condensing.
Do not store the HMI in a place subjected to corrosive gases and liquids.
Correctly packaged and placed on a solid and durable surface.
Do not mount the HMI adjacent to heat-radiating elements or in direct sunlight.
Do not mount the HMI in a location subjected to corrosive gases, liquids, or airborne dust or metallic
particles.
Do not mount the HMI in a location where temperatures and humidity will exceed specification.
Do not mount the HMI in a location where vibration and shock will exceed specification.
Do not mount the HMI in a location where it will be subjected to high levels of electromagnetic
radiation.
Installation
Installation Note:
Improper installation will result in malfunction and greatly reduce the life of the HMI. Be sure to
follow the guidelines in this quick start when installing the HMI.
In order to ensure the HMI being well ventilated, make sure that the ventilation holes are not
obstructed and must provide sufficient free space around HMI.
For use on a flat surface of a Type 4X "Indoor Use Only" enclosure or equivalent.
English-3
Installation Method:
Step 1: Ensure to put waterproof gasket into HMI
and then insert the HMI into the panel cutout.
Step 2: Ensure to insert fasteners into the HMI’s
insertion slots and turn the screw till screws touch panel
cutout.
Step 3: Turn the screw with less than torque 0.7N.M to avoid damage to plastic box.
Torque: 6.17lb-inch(0.7N-M)
Power Line Installation
Recommended wiring is in the table below:
Type Wire Gauge (AWG) Stripped length Torque
Solid 28~12 7~8 mm 4.5 lb-in
Stranded 28~12 7~8 mm 4.5 lb-in
Be sure to plug power line into HMI according to following arrow direction.
DOP-AS38BSTD(-W) DOP-A(E)57G(B)(C)STD(-W)
English-4
Basic Inspection
Item Content
General Inspection
Periodically inspect the screws of the connection between the HMI and device.
Tighten screws as necessary as they may loosen due to vibration and varying
temperatures.
Ensure that oil, water, metallic particles or any foreign objects do not fall inside the
HMI, control panel or ventilation slots and holes. As these will cause damage.
Ensure the correct installation and the control panel. It should be free from
airborne dust, harmful gases or liquids.
Inspection before
operation (power is
not applied)
Ensure that all wiring terminals are correctly insulated.
Ensure that all wiring is correct or damage and or malfunction may result.
Visually check to ensure that there are not any unused screws, metal strips, any
conductive or inflammable materials inside HMI.
Ensure to lower electromagnetic interference when devices are influenced by it.
Ensure that the external applied voltage to HMI is correct and matched to the
controller.
Inspection before
operation (power is
applied)
Check if power LED lights.
Check if the communication among devices is normal.
Please contact your local Delta sales representative if there are any abnormal
conditions.
Pin Definition of Serial Communication
COM1 Port [A, AE and AS57BSTD Series]
Contact
COM Port PIN
RS-232
1
2 RXD
3 TXD
4
5 GND
6
7 RTS
8 CTS
9
Note: Blank = No Connection.
DOP-A80THTD1
DOP-AE80THTD
DOP-AE94BSTD
DOP-A(E)10THTD1
DOP-AS57BSTD
Pin
English-5
COM2 Port [A Series]
MODE1 MODE2 MODE3
COM Port PIN
RS-232 RS-422 RS-485
1 RXD- D-
2 RXD RXD+ D+
3 TXD TXD+ D+
4 TXD- D-
5 GND
6 RTS-
7 RTS RTS+
8 CTS CTS+
9 CTS-
Note 1: Blank = No Connection.
Note 2: When selecting Mode3 (for RS-485), D+ indicates that PIN 2 and PIN 3 is connected, and D-
indicates that PIN 1 and PIN 4 is connected.
COM2 and COM3 Port [AE, A80THTD1 and A10THTD1 Series]
MODE1 MODE2 MODE3 MODE4 MODE5 MODE6
COM Port PIN
RS-232 RS-422 RS-485 RS-232*2 RS-422*2 RS-485*2
1 RXD- D- RXD1- D1-
2 RXD RXD+ D+ RXD1 RXD1+ D1+
3 TXD TXD+ D+ TXD1 TXD1+ D1+
COM2
4 TXD- D- TXD1- D1-
5 GND
6 RTS- TXD2- D2-
7 RTS RTS+ TXD2 TXD2+ D2+
8 CTS CTS+ RXD2 RXD2+ D2+
COM3
9 CTS- RXD2- D2-
Note 1: Blank = No Connection.
Note 2: When selecting Mode3 (for RS-485), D+ indicates that PIN 2 and PIN 3 is connected, and D-
indicates that PIN 1 and PIN 4 is connected. When selecting Mode6 (for RS-485), D1+
indicates that PIN 2 and PIN 3 is connected, D1- indicates that PIN 1 and PIN 4 is connected,
D2+ indicates that PIN 7 and PIN 8 is connected, and D2- indicates that PIN 6 and PIN 9 is
connected.
COM1 and COM3 [AS38BSTD Series]
MODE1 MODE2
COM Port PIN
RS-232 RS-232*2
1
2 RXD RXD1
3 TXD TXD1
COM1
4
5 GND
6
7 RTS TXD2
8 CTS RXD2
COM3
9
Note: Blank = No Connection.
Pin
Pin
Pin
English-6
COM2 Port [AS38BSTD Series]
MODE1 MODE2
COM Port PIN
RS-422 RS-485
R- RXD- D-
R+ RXD+ D+
T- TXD- D-
T+ TXD+ D+
G GND
Note 1: When selecting Mode2 (for RS-485), D+ indicates that R+ and T+ is connected, and D-
indicates that R- and T- is connected.
COM2 and COM3 Port [AS57BSTD Series]
MODE1 MODE2
COM Port PIN
RS-422 RS-485
R- RXD- D-
R+ RXD+ D+
T- TXD-
T+ TXD+
G
GND
(for COM2 and COM3 both)
Note: Blank = No Connection.
Dimensions
DOP-AS38BSTD(-W)
118.8
+0.04+1
(4.68 )
140.8
104.8
0
0
(3.65 )
T=1.6mm(0.06in) ~
92.8
0
+1
3.0mm(0.12in)
NOTE:
0
+0.04
T
4-R3
36.7
R-
COM3
COM2
Units:mm
English-7
DOP-AS57BSTD
0.12in(3.0mm)
T=0.06in(1.6mm) ~
(5.21 )
+1
0
+0.04
0
(6.79 )
0
+1 +0.04
0
144.1(5.67)
184.1(7.25)
6.1(0.24)39.0(1.54)
172.4
132.4
4-R3(0.12)
T
NOTE:
DOP-A(E)57G(B)(C)STD(-W)
3.0mm(0.12in)
T=1.6mm(0.06in) ~
(5.21 )
+1
0
+0.04
0
(6.79 )
0
+1 +0.04
0
144.1(5.67)
184.1(7.25)
6.1(0.24)39.0(1.54)
172.4
132.4
4-R3(0.12)
T
NOTE:
DOP-A80THTD1 / DOP-AE80THTD
T=1.6mm(0.06in) ~
3.0mm(0.12in)
(1.75)
178.1(7.01)
243.1(9.57)
0
+1
231.4
0
(9.11 )
+0.04
+0.04
(6.55 )
0
+1
166.4
0
NOTE:
4
-
R
3
.
0
(
0
.
1
2
)
44.4
T
6.1(0.24)
Units:mm
Units:mm
Units:mm
English-8
DOP-AE94BSTD
(8.27 )
210.2
0
+1
+0.04
0
285.2
0
+1
(11.22 )
+0.04
0
4
-
R
3
.
0
NOTE:
T=1.6mm(0.06in) ~
3.0mm(0.12in)
T
DOP-A(E)10THTD1
3.0mm(0.12in)
+0.04
(11.22 )
+1
0
0
T=1.6mm(0.06in) ~
(8.27 )
+1
0
+0.04
0
210.2
285.2
4
-
R
3
.
0
(
0
.
1
2
)
NOTE:
T
297.1(11.70)
222.1(8.74)
43.1(1.70) 6.1(0.24)
Units:mm
Units:mm
English-9
Specifications
MODEL AS38BSTD(-W) AS57BSTD A(E)57BSTD(-W) A(E)57GSTD(-W)
Display Type
3.8” STN LCD
(8 shades of blue)
5.7” STN LCD
(8 shades of blue)
5.7” STN LCD
(8 shades of blue)
5.7” FSTN LCD
(16 shades of gray)
Resolution 320 x 240 pixels
Back Light
LED Back Light
(about 10 thousand
hours at 25
o
C)
CCFL Back Light (about 50 thousand hours at 25
o
C)
LCD MODULE
Display Size
3.8”
(76.8 x 57.6mm)
5.7” (115.17 x 86.37mm)
Operation System
Windows Base Real Time OS
MCU
32-bit RISC Micro-controller
NOR Flash ROM
NOR Flash ROM 2 Mbytes
(System: 1MB / User: 1MB
NOR Flash ROM 4 Mbytes
(System: 1MB / User: 3MB)
SDRAM
4 Mbytes 16Mbytes
Backup Memory
(Bytes)
128K
A: 256K
AE: 512K
SM Card
3 3
EXT.
Memory
USB Host
(Ver 1.1)
3 3
Extension Interface
3 (AE) 3 (AE)
USB for Download
[USB Client]
1 USB Client Ver 1.1
USB for Data
Storage / Printer
[USB Host]
3 3
COM1
RS-232
COM2
RS-422 / RS-485 RS-232 / RS-422 / RS-485
Serial
COM
Port
COM3
RS-232 RS-422 / RS-485 RS-232 / RS-422 / RS-485 (AE)
Function Key User defined key x 4 + System key x 1
Operation Voltage
DC +24V (-10% ~ +15%) (Please use isolated power supply)
(Note 2)
Backup Battery
3V lithium battery CR2032 x 1 / battery life: 5 years
Buzzer 85dB
Perpetual Calendar
(RTC)
Built-in
Cooling Method Natural air circulation
Safety Approval
(Waterproof for
front panel)
IP65 / NEMA4 / CE, UL
(Note 1)
Operation Temp.
0°C ~ 50°C
Storage Temp.
-20°C ~ +60°C
English-10
MODEL AS38BSTD(-W) AS57BSTD A(E)57BSTD(-W) A(E)57GSTD(-W)
Ambient Humidity
10% ~ 90% RH [0 ~ 40°C], 10% ~ 55% RH [41 ~ 50°C]
Pollution Degree 2
Vibration
Resistance
IEC 61131-2 Compliant
5Hzf9Hz = Continuous: 1.75mm / Occasional: 3.5mm
9Hzf150Hz = Continuous: 0.5g / Occasional: 1.0g
X, Y, Z directions for 10 times
Dimensions
(W) x (H) x (D) mm
140.8 x 104.8 x
44.8
184.1 x 144.1 x 47
Panel Cutout
(W) x (H) mm
118.8 x 92.8 172.4 x 132.4
Weight Approx. 310g Approx. 760g
NOTE
1) DOP-AE94BSTD this model is not UL recognized.
2) Users please use isolated power supply except DOP-A80THTD1, DOP-AE80THTD, DOP-AE94BSTD, and
DOP-A(E)10THTD1 these models.
3) Users can download the Screen Editor, the program editor of Delta HMI product and the user manual via the
following link: http://www.delta.com.tw/industrialautomation/.
4) The content of this quick start may be revised without prior notice. Please consult our distributors or download the
most updated version at http://www.delta.com.tw/industrialautomation/.
English-11
MODEL A(E)57CSTD(-W)
A80THTD1
AE80THTD
AE94BSTD A(E)10THTD1
Display Type
5.7” STN LCD
(256 colors)
8” TFT LCD
(65536 colors)
9.4” STN LCD
(8 shades of blue)
10.4” TFT LCD
(65536 colors)
Resolution 320 x 240 pixels 640 x 480 pixels
Back Light
CCFL Back Light
(about 50 thousand
hours at 25
o
C)
CCFL Back Light
(about 50 thousand
hours at 25
o
C)
CCFL Back Light
(about 30 thousand
hours at 25
o
C
CCFL Back Light
(about 30 thousand
hours at 25
o
C
LCD MODULE
Display Size
5.7” (115.17 x
86.37mm)
8” (162.2 x
121.7mm)
9.4” (192.0 x
144.0mm)
10.4” (211.2 x
158.4mm)
Operation System
Windows Base Real Time OS
MCU
32-bit RISC Micro-controller
NOR Flash ROM
NOR Flash ROM 4
Mbytes (System:
1MB / User: 3MB)
NOR Flash ROM 8 Mbytes (System: 1MB / User: 7MB)
SDRAM
16 Mbytes 32 Mbytes 16Mbytes 32 Mbytes
Backup Memory
(Bytes)
A: 256K
AE: 512K
512K 512K 512K
SM Card
3
3 (AE)
EXT.
Memory
USB Host
(Ver 1.1)
3 3 3
Extension Interface
3 (AE)
3 (AE)
3
3 (AE)
USB for Download
[USB Client]
1 USB Client Ver 1.1
USB for Data
Storage / Printer
[USB Host]
3 3 3
COM1
RS-232
COM2
RS-232 / RS-422 / RS-485
Serial
COM
Port
COM3
RS-232 / RS-422 /
RS-485 (AE)
RS-232 / RS-422 / RS-485
Function Key
User defined key x
4 + System key x 1
User defined key x
6 + System key x 1
User defined key x
11 + System key x
1
User defined key x
7 + System key x 1
Operation Voltage
DC +24V (-10% ~ +15%) (Please use isolated power supply)
(Note 2)
Backup Battery
3V lithium battery CR2032 x 1 / battery life: 5 years
Buzzer 85dB
Perpetual Calendar
(RTC)
Built-in
Cooling Method Natural air circulation
Safety Approval
(Waterproof for
front panel)
IP65 / NEMA4 / CE, UL
(Note 1)
Operation Temp.
0°C ~ 50°C
English-12
MODEL A(E)57CSTD(-W)
A80THTD1
AE80THTD
AE94BSTD A(E)10THTD1
Storage Temp.
-20°C ~ +60°C
Ambient Humidity
10% ~ 90% RH [0 ~ 40°C], 10% ~ 55% RH [41 ~ 50°C]
Pollution Degree 2
Vibration
Resistance
IEC 61131-2 Compliant
5Hzf9Hz = Continuous: 1.75mm / Occasional: 3.5mm
9Hzf150Hz = Continuous: 0.5g / Occasional: 1.0g
X, Y, Z directions for 10 times
Dimensions
(W) x (H) x (D) mm
184.1 x 144.1 x 47
243.1 x 178.1 x
52.4
297.1 x 222.1 x
50.9
297.1 x 222.1 x
51.1
Panel Cutout
(W) x (H) mm
172.4 x 132.4 231.4 x 166.4 285.2 x 210.2
Weight Approx. 760g Approx. 1140g Approx. 1700g Approx. 1735g
NOTE
1) DOP-AE94BSTD this model is not UL recognized.
2) Users please use isolated power supply except DOP-A80THTD1, DOP-AE80THTD, DOP-AE94BSTD, and
DOP-A(E)10THTD1 these models.
3) Users can download the Screen Editor, the program editor of Delta HMI product and the user manual via the
following link: http://www.delta.com.tw/industrialautomation/.
4) The content of this quick start may be revised without prior notice. Please consult our distributors or download the
most updated version at http://www.delta.com.tw/industrialautomation/.
繁中-1
序言
感謝您使用本產品本人機介面安裝手冊提供 DOP-AAEAS 系列人機介面的相關資訊在使用之前,
請您仔細詳讀本手冊以確保使用上的正確此外請妥善將其放置在明顯的地點以便隨時查閱下列事項
在您尚未讀完本手冊前,請務必遵守
安裝的環境必須沒有水氣,腐蝕性氣體及可燃性氣體。
接線時,請依接線圖說明施工。
接地工程必須確實實施。
在通電時,請勿拆解人機介面或更改配線。
在通電運作時,請勿接觸電源處,以免觸電。
如果您在使用上仍有問題請洽詢經銷商或者本公司客服中心。由於產品精益求精,當內容規格有所修正
時,請洽詢代理商或至台達網站(http://www.delta.com.tw/industrialautomation/)下載最新版本
安全注意事項
安裝、配線、操作、維護及檢查時,應隨時注意以下安全注意事項。
安裝注意
¾ 依照手冊指定的方式安裝人機介面,否則可能導致設備損壞。
¾ 禁止將本產品暴露在有水氣、腐蝕性氣體、可燃性氣體等物質的場所下使用,否則可
能會造成觸電或火災。
配線注意
¾ 請將接地端子連接到 class-3100 Ω以下)接地,接地不良可能會造成通訊異常、觸
電或火災。
操作注意
¾ 人機介面需配合編輯軟體規劃畫面,未經規劃或確認之人機介面可能會導致不正常運
轉結果。
¾ 不得在開啟電源情況下改變配線,否則可能造成觸電或人員受傷。
¾ 請勿以尖銳物品碰觸面板,否則可能導致面板凹陷,進而使人機介面無法正常運作。
保養及檢查
¾ 禁止接觸人機介面內部,否則可能會造成觸電。
¾ 電源啟動時,禁止拆下人機介面面板,否則可能會造成觸電。
¾ 電源關閉 10 分鐘內,不得接觸接線端子,殘餘電壓可能造成觸電。
¾ 更換備用電池時,應切斷電源再進行,並在更換後重新檢查系統設定值
¾ 人機介面在操作時,排氣孔不可封住,否則人機容易因為散熱不良而造成故障。
繁中-2
配線方法
¾ 配線時請將快速接頭從人機介面的本體上拆下來。
¾ 快速接頭的一個電線插入口,請僅插入一根電線。
¾ 對於錯誤強行拔出電線的動作,請重新檢查連接電線再啟動。
通訊電路的配線
¾ 請依標準規格採用通訊配線線材。
¾ 通訊線材長度需在符合規定內。
¾ 採用正確的接地迴路,以避免通訊不良。
安裝環境條件
本產品在安裝之前必須置於其包裝箱若暫時不使用為了使該產品能夠符合本公司的保固範圍及日後
的維護,儲存時務必注意下列事項:
必須置於無塵垢、乾燥之位置。
儲存位置的環境溫度必須在-20°C to +60°C-4°F to 140°F)範圍內。
儲存位置的相對溼度必須在 10% 90%範圍內,且無結露。
避免儲存於含有腐蝕性氣、液體之環境中。
最好適當包裝存放在架子或檯面。
本產品適合的安裝環境包括有:無發高熱裝置之場所;無水滴、蒸氣、灰塵及油性灰塵之場所;
無腐蝕、易燃性之氣、液體之場所;無漂浮性的塵埃及金屬微粒之場所堅固無振動、無電磁雜
訊干擾之場所。
安裝方向與空間
注意事項:
安裝方向必須依規定,否則會造成故障原因。
為了使冷卻循環效果良好,安裝人機介面時,其上下左右與相鄰的物品和擋板()必須保持足
的空間,否則會造成散熱不良。
使用於 Type 4X 室內用等級之外殼平面。
安裝示意圖:
步驟一 請確實將防水墊圈裝入然後再安裝人機
介面
步驟二 請確實將固定片螺絲組裝入內,然後下方鉤
住前蓋螺絲頭頂住控制箱內側
繁中-3
步驟三 請以 0.7N.M 扭力鎖緊,切記不可超過此扭力,否則將造成塑膠外殼的損壞。
扭力:6.17lb-inch0.7N-M
配線
建議配線材料如下
種類 電源配線(AWG 剝線長度
扭力
單芯線
28 ~ 12 7 ~ 8 mm 4.5 lb-in
多芯線
30 ~ 12 7 ~ 8 mm 4.5 lb-in
請確實依指示方向將快速接頭裝入
DOP-A80THTD1
DOP-AE80THTD
DOP-AE94BSTD
DOP-A(E)10THTD1
DOP-AS38BSTD(-W) DOP-A(E)57G(B)(C)STD(-W)
DOP-AS57BSTD
繁中-4
基本檢測
檢測項目 檢測內容
一般檢測
定期檢查人機介面與設備連接處的螺絲是否有鬆動。
排氣孔應避免油水或金屬粉等異物侵入且應防止電鑽的切削粉落入人機介
面內。
人機介面若設置於有害氣體或多粉塵的場所,應防止有害氣體與粉塵的侵入。
操作前檢測
(未供應控制電源
配線端子的接續部請實施絕緣處理。
通訊配線應正確,否則可能發生異常動作。
檢查螺絲或金屬片等導電性物體、可燃性物體是否存在人機介面內。
人機介面附近使用的電子儀器受到電磁干擾時請使用儀器調校以降低電磁干
擾。
請確定人機介面的供應電源電壓準位是否正確。
運轉前檢測
(已供應控制電源
電源指示燈是否顯示。
與各設備之間通訊動作是否正常。
人機介面若有異常現象,請與廠商聯絡。
通訊腳位定義
COM1 定義【適用 AAEAS57BSTD 系列】
說明
COM Port 示意圖 腳位
RS-232
1
2 RXD
3 TXD
4
5 GND
6
7 RTS
8 CTS
9
註:空白=不需連
COM2 定義【適用 A 系列】
MODE1 MODE2 MODE3
COM Port 示意圖 腳位
RS-232 RS-422 RS-485
1 RXD- D-
2 RXD RXD+ D+
3 TXD TXD+ D+
4 TXD- D-
5 GND
6 RTS-
7 RTS RTS+
8 CTS CTS+
9 CTS-
1:空白=不需連接
2:使用 Mode3 時,D+Pin2Pin3 短路,D-Pin1Pin4 短路
Pin
Pin
繁中-5
COM2COM3 定義【適用 AEA80THTD1A10THTD1 系列】
MODE1 MODE2 MODE3 MODE4 MODE5 MODE6
COM Port 示意圖
COM
Port
腳位
RS-232 RS-422 RS-485 RS-232*2 RS-422*2 RS-485*2
1 RXD- D- RXD1- D1-
2 RXD RXD+ D+ RXD1 RXD1+ D1+
3 TXD TXD+ D+ TXD1 TXD1+ D1+
COM2
4 TXD- D- TXD1- D1-
5 GND
6 RTS- TXD2- D2-
7 RTS RTS+ TXD2 TXD2+ D2+
8 CTS CTS+ RXD2 RXD2+ D2+
COM3
9 CTS- RXD2- D2-
1:空白=不需連接
2:使用 Mode3 時,D+Pin2Pin3 短路,D-Pin1Pin4 短路
使用 Mode6 時,D1+Pin2Pin3 短路,D1-Pin1Pin4 短路,D2+Pin7Pin8 短路,D2-
Pin6Pin9 短路
COM1COM3 定義【適用 AS38BSTD 系列】
MODE1 MODE2
COM Port 示意圖
COM Port
腳位
RS-232 RS-232*2
1
2 RXD RXD1
3 TXD TXD1
COM1
4
5 GND
6
7 RTS TXD2
8 CTS RXD2
COM3
9
註:空白=不需連
COM2 定義【適用 AS38BSTD 系列】
MODE1 MODE2
COM Port 示意圖
腳位
RS-422 RS-485
R- RXD- D-
R+ RXD+ D+
T- TXD- D-
T+ TXD+ D+
G GND
1:使用 Mode2 時,D+R+T+短路,D-R-T-短路
Pin
R-
Pin
繁中-6
COM2COM3 定義【適用 AS57BSTD 系列】
MODE1 MODE2
COM Port 示意圖 腳位
RS-422 RS-485
R- RXD- D-
R+ RXD+ D+
T- TXD-
T+ TXD+
G
GND
(COM2COM3 共用)
註:空白=不需連
尺寸規格
DOP-AS38BSTD(-W)
118.8
+0.04+1
(4.68 )
140.8
104.8
0
0
(3.65 )
T=1.6mm(0.06in) ~
92.8
0
+1
3.0mm(0.12in)
NOTE:
0
+0.04
T
4-R3
36.7
COM3
COM2
單位mm
繁中-7
DOP-AS57BSTD
0.12in(3.0mm)
T=0.06in(1.6mm) ~
(5.21 )
+1
0
+0.04
0
(6.79 )
0
+1 +0.04
0
144.1(5.67)
184.1(7.25)
6.1(0.24)39.0(1.54)
172.4
132.4
4-R3(0.12)
T
NOTE:
DOP-A(E)57G(B)(C)STD(-W)
3.0mm(0.12in)
T=1.6mm(0.06in) ~
(5.21 )
+1
0
+0.04
0
(6.79 )
0
+1 +0.04
0
144.1(5.67)
184.1(7.25)
6.1(0.24)39.0(1.54)
172.4
132.4
4-R3(0.12)
T
NOTE:
DOP-A80THTD1DOP-AE80THTD
T=1.6mm(0.06in) ~
3.0mm(0.12in)
(1.75)
178.1(7.01)
243.1(9.57)
0
+1
231.4
0
(9.11 )
+0.04
+0.04
(6.55 )
0
+1
166.4
0
NOTE:
4
-
R
3
.
0
(
0
.
1
2
)
44.4
T
6.1(0.24)
單位mm
單位mm
單位mm
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37

Delta Electronics AS57BSTD クイックスタートガイド

タイプ
クイックスタートガイド
このマニュアルも適しています