VI.IX.C1.02
2 | © Danfoss | DHS-SRMT/SI | 2017.07
oss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
vided that such alterations can be made without subsequential changes being necessary eady agreed.
All trademarks in this material are property of the respec
tive companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
VFH-WG/VFH-WH
EN
When installing, leave the butterfly valve partly open. Make sure there is
enough distance between pipeline flanges to place the valve. Don’t add
sealing gaskets between the flange and the valve.
Insert bolts into flange and tighten opposing nuts sequentially. Make sure
that valve is aligned with the flange.
Fully open the valve. Make sure that the disc is centered and there is no
jam between the valve and the disc.
CN
安装阀门时,蝶板应处于接近全关的位置。确定管道法兰间有足够的距离
将阀门插入法兰中间。蝶阀安装时无须再加密封垫,蝶阀端面自带软密封
面 。
将螺栓穿入法兰盘,用手或扳手对称轮流预紧螺栓,以法兰盘端面凸台或
外圆及阀体外圆为相互参照物,确认阀门是否与法兰盘对中。
谨慎地,轻轻地将阀门开启到全开位置,检查阀板是否对中,检查阀板与
法兰内孔有无磕碰现象。