CommScope BSAMNT Series インストールガイド

タイプ
インストールガイド
Pre-assembly of Downtilt Brackets
Middle Mount Installation
• Bracket edges parallel to each other.
(fully collapsed position)
Part Lists
14
M10 bolt
M12 bolt
ATTENTION: Insert M12 bolts and M12
flat washers into bracket with tabs
prior to attaching bracket to antenna.
7
3
4
5
two hole plate
M8 bolt
6
M10 bolt
CRITICAL: For initial installation
to pipe, downtilt brackets must
be configured in pre-assembly
position (fully collapsed).
10
12
13
11
1
2
98
98
ITEM NO.
DESCRIPTION
QTY
U/M
1
PIPECLAMP BRACKET, NO FLANGE
1 EA
2
PIPECLAMP BRACKET, SHORT FLANGES
1 EA
3
NOTCHED BRACKET
1 EA
4
BRACKET
1 EA
5
SCR,HH,HEX,M8X25,SST,PASS
4 EA
6
WSHR,LK,SPLT,M8,STL,GALV
4 EA
7
TWO HOLE PLATE, 8mm X 1.25 PITCH
2 EA
8
NUT,HEX,M10,STL,GALV
8 EA
9
WSHR,LK,SPLT,M10,STL,GALV
4 EA
10
SCR,HCS,HEX,M10X40,STL,GALV
4 EA
11
NUT,HEX,M12,STL,GALV
4 EA
12
WSHR,FLT,M12,13X28X2.5,STL,GALV
2 EA
13
WSHR,LK,SPLT,M12,STL,GALV
2 EA
14
BOLT,CARRIAGE,M12 X 200,STL,GALV
2 EA
MAXIMUM TORQUE
M8
15N.m (11ft.lbs)
M10
37N.m (27ft.lbs)
M12
58N.m (43ft.lbs)
Installation Instructions
Mounting Kits For Wide Panel Antennas
BSAMNT Series: Mounting systems for
cylindrical pipe
installations (60-115mm pipe diameter) for heavy duty applications
Bulletin 639834 • Revision A • December 2014 • Page 1 of 2
CommScope Infrastructure Academy offers installation training.
BSAMNT Mounting Kit
Bulletin 639834 • Revision A • December 2014 Page 2 of 2
use inclinometer to
adjust antenna angle
Adjusting Antenna Tilt
(Continued from page 1)
Loosen pivot bolts . (do
not remove)
• Remove adjuster bolts.
• Adjust antenna angle.
(use inclinometer)
• Reinstall adjuster bolts.
Middle Bracket First
• Retighten all bolts.
M10 pivot bolt
(loosen only)
M10 pivot bolt
(loosen only)
SAFETY NOTICE
The installation, maintenance, or removal of an antenna
requires qualified, experienced personnel. CommScope
installation instructions are written for such installation
personnel. Antenna systems should be inspected once a
year by qualified personnel to verify proper installation,
maintenance, and condition of equipment.
CommScope disclaims any liability or responsibility for the
results of improper or unsafe installation practices.
It is recommended that transmit power be turned off
when the field installation is performed. Follow all
applicable safety precautions as shown on this page.
Do not install on a wet or windy
day or when lightning or thunder
is in the area. Do not use metal
ladder.
Do not install near power lines.
Power lines, telephone lines,
and guy wires look the same.
Assume any wire or line can
electrocute you.
Wear shoes with rubber soles and
heels. Wear protective clothing
including a long-sleeved shirt and
rubber gloves.
M8 adjuster bolt
perimeter location
(remove to adjust tilt)
DETAIL A
M10 pivot bolt
(loosen only)
A
M10 pivot bolt
(loosen only)
(BSAMNT-1)
(BSAMNT-M)
(BSAMNT-1)
CommScope
Customer Service 24 hours
1100 CommScope Place SE P.O. Box 339, Hickory, NC 28603-0339 North America: +1-800-255-1479 (toll free)
(828) 324-2200 (800) 982-1708 Any country: +1-779-435-6500
www.commscope.com/andrew email: [email protected]
Notice: CommScope disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance, or removal practices.
Aviso: CommScope no acepta ninguna obligación ni responsabilidad como resultado de prácticas incorrectas o peligrosas de instalación, inspección, mantenimiento o retiro.
Avis : CommScope décline toute responsabilité pour les conséquences de procédures d’installation, d’inspection, d’entretien ou de retrait incorrectes ou dangereuses.
Hinweis: CommScope lehnt jede Haftung oder Verantwortung für Schäden ab, die aufgrund unsachgemäßer Installation, Überprüfung, Wartung oder Demontage auftreten.
Atenção: A CommScope abdica do direito de toda responsabilidade pelos resultados de práticas inadequadas e sem segurança de instalação, inspeção, manutenção ou remoção.
Avvertenza: CommScope declina eventuali responsabilità derivanti dell’esecuzione di procedure di installazione, ispezione, manutenzione e smontaggio improprie o poco sicure.
注意: CommScope 公司申明对于不恰当或不安全的安装、检验、维修或拆卸操作所导致的后果不负任何义务和责任。
© 2014 CommScope Bulletin 639834
M8 pivot bolt
center location
(loosen only)
MAXIMUM TORQUE
M8
15N.m (11ft.lbs)
M10
37N.m (27ft.lbs)
M12
58N.m (43ft.lbs)
预安装的下倾安装架
• 安装架的上下面互相平行。
(完全折叠状态)
零件清单
5
M8螺栓
7
3
4
10
14
注意:在将安装架安装到天线上之前,先将
M12螺栓及平垫圈插入带凸耳式安装架。
M10螺栓
M10螺栓
M12螺栓
中部支架安装
两孔螺纹板
6
关键
:在将安装架安装到抱杆前,
确认安装架在预安装状态
(完全折叠)。
1
2
11
13
12
1098
98
序号 描述 数量 单位
1 抱杆安装支架 1
2 抱杆安装支架 1
3 下倾安装支架 1
4 下倾安装支架 1
5 M8X25六角螺栓,不锈钢 4
6 M8弹垫,热镀锌碳钢 4
7 两孔螺纹板M8X1.25 2
8 M10六角螺母,热镀锌碳钢 8
9 M10弹垫,热镀锌碳钢 4
10 M10X40六角螺栓,热镀锌碳钢 4
11 M12六角螺母,热镀锌碳钢 4
12 M12平垫,13X28X2.5热镀锌碳钢 2
13 M12弹垫,热镀锌碳钢 2
14 M12X200马车螺栓,热镀锌碳钢 2
最大扭力
M8
15N.m (11ft.lbs)
M10
37N.m (27ft.lbs)
M12
58N.m (43ft.lbs)
BSAMNT系列安装架适用于
圆柱抱杆(直径为60-115mm)应用于重型天线
安装说明
安德鲁培训学院提供安装培训
公告
639834 • 修订版 A • 2014 年 12 月 • 第 1 页 共 2 页
平板宽天线安装架
使用倾角罗盘调节天线角度
调节天线倾角
旋松枢轴螺栓
(不要移除)。
移除调节螺栓。
调节天线角度
(用倾角罗盘)。
重新安装调节螺栓。
先安中间的支架
重新旋紧所有螺栓。
BSAMNT 安装架
(接第1页)
公告 639834
• 修订版 A • 2014 年 12 月 • 第 2 页 共 2 页
安全事项
天线的安装、维护或拆卸都需要由经验丰富的合格技术人员进行
操作。康普(CommScope)安装说明是专为这些安装人员编写的。
天线系统应由合格人员每年检查一次,以确定设备的安装、维护
和状况良好。
对于因不当或不安全安装导致的任何后果,康普概不负责。
在现场安装时,务必关掉发射设备。遵从此页所显示的所有适用
的安全措施。
请勿安装在电源线附件。电源
线、电话线和拉线外观相同,
任何导线度可能致人触电身亡。
请勿在有雨、有风或者所在
区域有闪电或雷声时安装,
请勿使用金属梯子。
请穿上有橡胶鞋底和橡胶跟的鞋
子。请穿有长袖衬衫和橡胶手套
的防护服。
M10枢轴螺栓
(仅旋松)
细节 A
M10枢轴螺栓
(仅旋松)
M10枢轴螺栓
(仅旋松)
M8调节螺栓
外周位置
(移除后调节倾角)
M10枢轴螺栓
(仅旋松)
A
(BSAMNT-1)
(BSAMNT-M)
(BSAMNT-1)
M8枢轴螺栓
中间位置
(仅旋松)
CommScope
24小时客户支持
1100 CommScope Place SE P.O. Box 339, Hickory, NC 28603-0339
北美:
: +1-800-255-1479 (免服务费)
(828) 324-2200 (800) 982-1708 其他国家:: +1-779-435-6500
www.commscope.com/andrew
电子邮件
注意: CommScope 公司申明对于不恰当或不安全的安装、检验、维修或拆卸操作所导致的后果不负任何义务和责任。
© 2014 CommScope Bulletin 639834
最大扭力
M8
15N.m (11ft.lbs)
M10
37N.m (27ft.lbs)
M12
58N.m (43ft.lbs)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

CommScope BSAMNT Series インストールガイド

タイプ
インストールガイド