Gigabyte R121-340 インストールガイド

タイプ
インストールガイド
Motherboard Components
No. Code Descripon
1 SW_ID ID buon with LED
2 USB3_1 USB 3.0 port #1
3 USB3_2 USB 3.0 port #2
4 MLAN Server managemnt LAN port
5 LAN1_2 GbE LAN port #1 /#2
6 COM1_VGA Serial port (top) / VGA port (boom)
7 PMBUS PMBus connector
8 P2 2x4 pin power connector (for CPU)
9 CASE_OPEN Case open intrusion alert header
10 P1 2x12 pin main power connector
11 CPU0 Intel LGA1151 Socket H4
12 BAT Baery socket
13 SATA_0_1 SATA 3 6Gb/s connectors
14 SATA_2_3 SATA 3 6Gb/s connectors
15 SATA_DOM1 SATA port 4 DOM power connector
16 SATA4 SATA 3 6Gb/s connectors (Supports SATA DOM)
17 SATA5 SATA 3 6Gb/s connectors (Supports SATA DOM)
18 SATA_DOM2 SATA port 5 DOM power connector
19 SATA_SGP1 SATA SGPIO header
20 F_USB3_1 USB 3.0 header
21 IPMB IPMB connector
22 BP_1 HDD back plane board header
23 FP_1 Front panel header
24 RISER_1_2 PCIe riser slot (for Gigabyte CRS1022 Only)
25 TPM TPM connector
26 PCIE_2 PCIe x8 slot
27 RISER_1_1 PCIe riser slot (for Gigabyte CRS1022 Only)
28 LED_BMC1 BMC firmware readiness LED
1 2 3 4 5 6
7
8
9
1011
13
14
15
1617
18
19
20
21
22
23
28
24 25
12
26
27
Default Enable
123
Default Enable
123
ME
Force
Update
ME_UPDATE
BIOS
Recovery
BIOS_RCVR
Enable
Default
3
2
1
Enable
ME
Recovery
BIOS_RCVR Default
3
2
1
Default Enable
123
Password
Clear
BIOS_PWD
Clear
CMOS
CLR_CMOS
S3
Power On
Select
S3_MASK
Default
Enable
3
2
1
System Components
No Descripon
1 HDD bays
2 Front panel buons and LEDs
3 System fan #3 (FAN3)
4 System fan #5 (FAN5)
5 System fan #7 (FAN7)
6 Fan duct
7 Memory slots
8 Power supply module
9 PCIe riser bracket
10 PCIe riser bracket
CAUTION!
Before you remove or install the system cover:
Make sure the system is not turned on or
connected to AC power.
注意!
在卸下或安装系统机盖之前,请注意
下列事项:
确保系统未开启且未连接到交流电源。
1
2
5
3
78
6
9
10
4
Front Panel Header
No. Pin Define
1 Power LED+
3 No Pin
5 Power LED-
7 HDD LED+
9 HDD LED-
11 Power Buon+
13 GND
15 Reset Buon+
17 GND
19 ID Switch+
21 ID Switch-
23 NMI Switch-
No. Pin Define
2 5V Standby
4 ID LED+
6 ID LED-
8 System Status LED+
10 System Status LED-
12 LAN1 Acve LED+
14 LAN1 Link LED-
16 SMBus Data
18 SMBus Clock
20 Case Open
22 LAN2 Acve LED+
24 LAN2 Link LED-
1
2423
2
HDD Back Plane Board Header
1 2
25 26
No. Pin Define
1 BP_SGP_CLK
3 BP_SGP_LOAD
5 BP_SGP_DOUT
7 Key Pin
9 GND
11 BP_LED_G_N
13 BP_SGP_DIN
15 GND
17 GND
19 P_3V3_AUX
21 P_3V3_AUX
23 GND
25 BP_PRESENSE
No. Pin Define
2 No Connect
4 FAN_SGP_Gate
6 GND
8 Reset
10 BP_LED_A_N
12 GND
14 No Connect
16 SMB_BP_DATA
18 SMB_BP_CLK
20 BMC_ACK
22 BMC_REQ
24 Key Pin
26 GND
System Cover
1
2
3
Fan Duct
1
2
Heat Sink
1
2
WARNING!
Please make sure the CPU heat sink installon orientaon.
Failure to observe the warning could result in damage to the equipment.
Memory Populaon Configuraon
Type
Ranks Per
DIMM and
Data Width
Speed (MT/s);
Slot Per Channel (SPC) and
DIMM Per Channel (DPC)
UDIMM
Unbuffered
DDR4 ECC
UDIMM
Unbuffered
DDR4 non-ECC
SR 1.2V
1.2V
2133 2133
Supported
Voltage
DR 2133 2133
2 Slot Per Channel
1DPC 2DPC
All channels in system run at the fastest common frequency.
Mixing ECC and non-ECC UDIMMs anywhere on the plaorm is not
supported.
1 and 2 DPC is supported at 2133MHz.
所有通道模式以最快的频率速度运行。
此主板不支持ECC与非ECC内存模组混合使用。
1 2 DPC 2133MHz
System Fan
CAUTION!
Before you remove or install the system fan:
Make sure the system is not turned on or
connected to the AC power.
Disconnect all necessary cable connecons.
Failure to observe these
warnings could result in personal injury or
damage to the equipment.
注意!
确保系统未开机且未连接到交流电源。
断开所有必要的线缆连接。若不遵循这些
警告,可能造成人员伤害或设备损坏。
21
No Descripon
1 HDD#3
2 HDD#2
3 HDD#1
4 HDD#0
5 SGPIO header
6 Fan connector#13
7 Fan connector#14
8 Fan connector#11
9 Fan connector#12
10 ODD power connector
11 Fan connector#9
HDD Backplane Board Components
No Descripon
12 Fan connector#10
13 Fan connector#7
14 Fan connector#8
15 Fan connector#5
16 Fan connector#6
17 Fan connector#3
18 Fan connector#4
19 Fan connector#1
20 Fan connector#2
21 Fan connector#15
22 Fan connector#16
Hard Disk Drive and Back Plane Board
5
1
234
6 7 8 9
10
11 12 13 14 15 16 17 18 19 20 21 22
1
2
3
System Front View
System Rear View
No Descripon
1 HDD bay #1
2 HDD bay #2
3 HDD bay #3
4 HDD bay #4
No Descripon
1 Power supply module cord socket
2 VGA port
3 Serial port
4 GbE LAN port
5 10/100/1000 Server management LAN port
6 USB 3.0 ports
7 Full-height riser card bay
8 Low-profile riser card bay
Front & Rear
Power buon/LED:
Green On
Off
Description
System is powered on
System is powered off
State
Speed LED Link/Acvity
LED
Off
State Description
Yellow On 1Gbps data rate
Green On 100Mbps data rate
10Mbps data rate
10/100/1000 LAN LED:
1 2 34
7 6 5
No Descripon
5 Power buon with LED
6 ID buon with LED
7 USB 3.0 ports
12 3
4 5 6
7 8
PCI Express Card
注意!
在安装扩展卡前,请注意下列事项:
确保系统未开启且未连接到交流电源。
CAUTION!
Before you remove or install the PCI express card:
Make sure the system is not turned on or connected to AC power.
2
3
2
3
11
1
45
6
45
6
注意!
在替换或安装电源前,请注意下列事项:
确保系统未开启且未连接到交流电源。
CAUTION!
Before you remove or install the power supplies:
Make sure the system is not turned on or connected to AC power.
Power Supply
1
1
3
3
4
2
Front Panel LED and Buons
6复位按钮 按此按钮启动系统。
2按下按钮启动系统识别功能。ID按钮
1系统处于开机状态。
系统处于ACPI S1状态(睡眠模式)。
系统未开机或处于ACPIS5状态(关机状态)。
系统处于ACPI S4状态(休眠模式)。
电源按钮和LED 绿色
绿色
恒亮
闪烁
5恒亮
闪烁
系统和网络之间的链接
网络访问
断开连接/待机
绿色
绿色
LAN1/LAN2活动LED
4硬盘驱动器定位
硬盘驱动器访问
硬盘驱动器故障
硬盘重建
无硬盘驱动器访问
绿色
橙色
绿色/橙色
闪烁
硬盘驱动器LED
闪烁
编号 名称 颜色 状态 说明
3
橙色
绿色
系统状态LED 恒亮
恒亮
闪烁
严重情形,可能为下列状况:
电源模块故障
系统风扇故障
电源电压问题
系统温度/电压问题
非严重情形,可能为下列状况:
冗余电源模块故障
系统温度/电压问题
机箱侵入
系统未正常运行,可能为下列状况:
POST错误
NMI错误
处理器或终结器缺失
No. Name Color Status Description
6Reset Button Press the button to reset the system.
2 Press the button to activate system identifcation.ID Button
1 System is powered on.
System is in ACPI S1 state (sleep mode).
System is not powered on or in ACPI S5 state (power off).
System is in ACPI S4 state (hibernate mode).
Power Button and LED Green
Green
Solid On
Blink
4HDD locate
HDD access
HDD fault
HDD rebuild
No HDD access or no HDD fault.
Green
Amber
Green/Amber
On
Blink
On
Blink
HDD Status LED
5Link between system and network or no access.
Data transmission or receiving is occurring.
No data transmission or receiving is occurring.
Solid On
Blink
Green
Green
LAN1/2 Active/Link LEDs
3 System is operating normally.System Status LED Green
Amber
Solid On
Critical condition, may indicates:
Power module failure
System fan failure
Power supply voltage issue
System temperature
Solid On
Non-critical condition, may indicates:
Redundant power module failure
Temperature and voltage issue
Chassis intrusion
System is not ready, may indicates:
POST error
NMI error
Processor or terminator missing
Blink
--
-- -- --
-- --
-- --
-- --
--
--
-- --
-- --
1236 45
R121-340 Quick Installaon Guide/ 快速安装手册
Regulatory Noces
Connect With Us
WEEE Symbol Statement
For more informaon, visit our website at:
hp://b2b.gigabyte.com
You are a professional?
Get access to our complete source of sales & markeng materials at:
hp://reseller.b2b.gigabyte.com
hps://www.facebook.com/gigabyteserver
The symbol shown below is on the product or on its packaging, which indicates that this product must not be disposed of with other
waste. Instead, the device should be taken to the waste collecon centers for acvaon of the treatment, collecon, recycling and
disposal procedure. The separate collecon and recycling of your waste equipment at the me of disposal will help to conserve
natural resources and ensure that it is recycled in a manner that protects human health and the environment.
For more informaon about where you can drop off your waste equipment for recycling, please contact your local government
office, your household waste disposal service or where you purchased the product for details of environmentally safe recycling.
When your electrical or electronic equipment is no longer useful to you, "take it back" to your local or regional waste
collecon administraon for recycling.
If you need further assistance in recycling, reusing in your "end of life" product, you may contact us at the Customer Care
number listed in your product's user's manual and we will be glad to help you with your effort.
GIGABYTE产品未故意添加和使用有害物质(Cd、Pb、Hg、Cr+6、PBDE和PBB)。所有部件和元件均经过严格挑选,符合RoHS要求。此
外,我们GIGABYTE一直致力于开发不使用国际上禁止的有毒化学品的产品。
GIGABYTE products have not intended to add and safe from hazardous substances (Cd, Pb, Hg, Cr+6, PBDE and PBB). The parts and components
have been carefully selected to meet RoHS requirement. Moreover, we at GIGABYTE are connuing our efforts to develop products that do not use
internaonally banned toxic chemicals.
Restricon of Hazardous Substances (RoHS) Direcve Statement
This server is intended for installaon only in restricted access locaons where .
Access can only be gained by SERVICE PERSONS who have been instructed about the reasons for the restricons applied to the
locaon and about any precauons that shall be taken.
Access is through the use of a TOOL or lock and key, or other means of security, and is controlled by the authority responsible for the locaon.
The following or similar rack-mount instrucons are included with the installaon instrucons:
A) Elevated Operang Ambient - If installed in a closed or mul-unit rack assembly, the operang ambient temperature of the rack environment
may be greater than room ambient. Therefore, consideraon should be given to installing the equipment in an environment compable with the
maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installaon of the equipment in a rack should be such that the amount of air flow required for safe operaon of the
equipment is not compromised.
C) Mechanical Loading - Mounng of the equipment in the rack should be such that a hazardous condion is not achieved due to uneven mechani-
cal loading.
D) Circuit Overloading - Consideraon should be given to the connecon of the equipment to the supply circuit and the effect that overloading of
the circuits might have on overcurrent protecon and supply wiring. Appropriate consideraon of equipment nameplate rangs should be used
when addressing this concern.
E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Parcular aenon should be given to supply connec-
ons other than direct connecons to the branch circuit (e.g. use of power strips)."
Disconnect 2 power supply cords before servicing
This device complies with Part 15 of the FCC Rules.
Operaon is subject to the following two condions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired operaon.
FCC Statement
This equipment should not be operated above an ambient operaon temperature of 35 degrees cengrade.
Ambient Operaon
CAUTION: The power supplies in your system may produce high voltages and energyhazards, which can cause bodily harms. Unless you are
instructed otherwise, only trained service technicians are authorized to remove the covers and access any of the components inside the system.
Power Supply
CAUTION: Do not connect of disconnect any cables or perform installaon, maintenance, or reconfiguraon of this server during an electrical storm
CAUTION: Connect all power cords to a properly wired and grounded electrical outlet.
Reliable Earthing:
CAUTION: This server contains hazardous moving fan blades, keep fingers and other bodyparts away.
Disconnect all power supply cords before servicing. Connect power supply cord only aer all the covers are properly installed.
Hazardous FAN
CAUTION: This server contains hazardous energy over 240VA on the backplane. To prevent accidental short circuit, always insert the
HDD trays aer servicing.
Hazardous Energy
Restricted Access Locaon
The system may have more than one power supply cable. To reduce the risk of electrical shock, a trained service technician may need to disconnect
all power supply cables before servicing the system.
Rack Mount Instrucons
CAN ICES-3 (A)/NMB-3(A)
CAUTION: Slider/rail mounted equipment is not to be
used as a shelf or a work space.
CAUTION: Whenever you need to li the system, get others to assist you.
To avoid injury, do not aempt to li the system by yourself.
限制使用有害物质 (RoHS) 指令声明
California Proposion 65 Warning
WARNING:
This product contains a chemicals , including lead, known to the State of California to cause cancer and birth defects or other reproducve harm.
For more informaon, please visit: hp://www.p65warnings.ca.gov/
Baery Warning:
Incorrectly installing a baery or using incompable baery may increase the risk of ifre explosion. Replace the baery only with
the same or equivalent type.
Do not disassemble, crush, punchture baeries.
Do not store or place your baery pack next to or in a heat source such as a fire, heatgenerang appliance, can or exhaust
vent. Heang baery cells to temperatures above 65oC (149oF) can cause explosion or fire.
Do not aempt to open or service baeries. Do not dispose of baeries in a fire or with household waste.
电池警告:
电池安装不当或使用不兼容的电池会增加火灾爆炸风险。更换电池时,只可使用相同或同等类型的电池。
请勿拆解、挤压、刺破电池。
请勿将电池存放或放置在热源中或旁边,如火源、产生热的设备、罐体或排气口。电池温度升至65oC (149oF)以上
可能导致爆炸或火灾。
请勿尝试打开或维修电池。电池废弃时,请勿投入火中或者作为家庭废弃物进行处理。
依照中华人民共和国的有毒有害物质的限制要求(China RoHS)提供以下的表格:
中华人民共和国电子信息产品中有毒有害物质或元素的名称及含量标识格式
  • Page 1 1
  • Page 2 2

Gigabyte R121-340 インストールガイド

タイプ
インストールガイド

他の言語で