MP30-AR0/MP30-AR1 Quick Reference Guide/ 快速测试参考指南
No. Code Descripon
1 LED_STA System status LED
2 USB2_MLAN KVM Server Management 10/100/1000 LAN port (top)/USB 2.0 ports (boom)
3 VGA1_COM1 Serial port (top)/VGA port (boom)
4 SFP+_1_2 SFP+ LAN port #1/#2
5 LAN1_2 GbE LAN port #1/#2
6 SW_PWR Power/Reset buon with LED
7 SW_ID ID switch buon with LED
8 CPU_FAN CPU fan connector
9 DIMM_P0_A0 Channel 1 slot 0
10 DIMM_P0_A1 Channel 1 slot 1
11 DIMM_P0_B0 Channel 2 slot 0
12 DIMM_P0_B1 Channel 2 slot 1
13 CPU0 AppliedMicro® X-Gene 1 processor
14 P12V_AUX 14 pin power connector
15 ATX1 24 pin main power connector
16 SYS_FAN1 System fan connector#2
17 FP_1 Front panel header (for Server system)
18 SYS_FAN2 System fan connector#3
19 PMBUS PMBus header
20 CLR_CMOS Clear CMOS jumper
No. Code Descripon
21 SYS_FAN3 System fan connector#3
22 BP_1 HDD back plane board header
23 CASE_OPEN Case open intrusion alert header
24 IPMB IPMB connector
25 SYS_FAN4 System fan connector#4
26 SATA_DOM0 SATA port 1 DOM support jumper
27 SATA1 SATA 3 6Gb/s connector
28 SATA0 SATA 3 6Gb/s connector
29 SATA3 SATA 3 6Gb/s connector
30 SATA2 SATA 3 6Gb/s connector
31 PCIE_2 PCI Express x16 slot (PCIe x8 Signal)
32 BAT Baery socket
33 PCIE_1 PCI Express x16 slot (PCIe x8 Signal)
34 LED_BMC BMC firmware readiness LED
35 DIMM_P0_C0 Channel 3 slot 0
36 DIMM_P0_C1 Channel 3 slot 1
37 DIMM_P0_D0 Channel 4 slot 0
38 DIMM_P0_D1 Channel 4 slot 1
1 2 3 4 5 67
8
9
12
13
14
151617181920
21
22
23
24
25
26
28
29
30
27
31
32
33
34
35
36
37
38
11
10
2
1
Front Panel Header/ HDD Back Plane Board Header/ 硬盤背板排針
1
24
23
2
No. Pin Define
1 Power LED+
3 No Pin
5 Power LED-
7 HDD LED+
9 HDD LED-
11 Power Buon
13 GND
15 Reset Buon
17 GND
19 ID Buon
21 GND
23 NMI Switch-
No. Pin Define
2 5V Standby
4 ID LED+
6 ID LED-
8 System Status LED+
10 System Status LED-
12 LAN1 Acve LED+
14 LAN1 Acve LED-
16 SMBus Data
18 SMBus Clock
20 Case Open
22 LAN2 Acve LED
24 LAN2 Acve LED-
1 2
25 26
No. Pin Define
1 BP_SGP_CLK
3 BP_SGP_LOAD
5 BP_SGP_DOUT
7 Key Pin
9 GND
11 BP_LED_G_N
13 BP_SGP_DIN
15 GND
17 GND
19 P_3V3_AUX
21 P_3V3_AUX
23 GND
25 PRESENCE
No. Pin Define
2 No Connect
4 FAN_Gate
6 GND
8 Reset
10 BP_LED_A_N
12 GND
14 No Connect
16 SMB_BP_DATA
18 SMB_BP_CLK
20 BMC_ACK
22 BMC_REQ
24 Key Pin
26 GND
ATX Power/
No. Pin Define
1 3.3V
2 3.3V
3 GND
4 +5V
5 GND
6 +5V
7 GND
8 Power Good
9 5VSB
10 +12V
11 +12V
12 3.3V
No. Pin Define
1 GND
2 GND
No. Pin Define
13 3.3V
14 -12V
15 GND
16 PS_ON
17 GND
18 GND
19 GND
20 -5V
21 +5V
22 +5V
23 +5V
24 GND
21
43 No. Pin Define
3 +12V
4 +12V
1
13
12
24
1
5
No Pin Define
1 SMB CLK
2 SMB DATA
3 SMB ALERT
PMBUS
No Pin Define
4 GND
5 3.3V
Memory Populaon Configuraon/ 安装内存
1 Slot
1DPC 1DPC 2DPC
A0 or C0
8 Slot
2DPC
Insert Full
A0+B0
or
A0+C0
1DPC
A0+B0
and
C0+D0
2DPC
A0+A1+B0+B1
or
A0+A1+C0+D0
A0+A1
or
C0+C1
2 Slot 4 Slot
Single DIMM per channel(1DPC) or Dual DIMMs per channel(2DPC) setting
Rear I/O Connector/后面板接口
Off
State Description
Yellow On 1Gbps data arte
Green On 100Mbps data arte
10Mbps data arte
10/100/1000 LAN LED:
State Description
Green On
Green Blink
Yellow On
Yellow Blink
Off
10 Gbps data rate
Identify 10 Gbps data rate
1 Gbps data rate
Identify 1 Gbps data rate
100 Mbps data rate
SFP+ LAN LED:
State Description
Green On System is operating normally.
Green Blink
Degrade condition, may indicates the following:
CPU failure
DIMM killed
Amber On
Critical condition, may indicates the following:
Power module failure
System fan failure
Power supply voltage issue
System temperature/voltage issue
Amber Blink
Non-critical condition, may indicates the following:
Redundant power module failure
Temperature and voltage issue
Chassis intrusion
N/A
System is not ready. May indicates the following:
POST error
NMI error
Processor or terminator missing
System Status LED:
Speed LED Link/Acvity
LED
Speed LED Link/Acvity
LED
Speed LED Link/Acvity
LED
No. Desripon
1 GbE LAN ports
2 SFP+ LAN ports
3 Serial port
4 VGA port
5 KVM Server Management 10/100/1000 LAN port (Dedicated LAN port)
6 USB 2.0 ports
7 System Status LED
系统状态LED:
绿色恒亮
绿色闪烁
橙色恒亮
橙色闪烁
颜色/状态 说明
。
无亮灯
效能降低情形,可能为下列状况:
处理器问题
内存问题
严重情形,可能为下列状况:
电源模块故障
系统风扇故障
电源电压问题
系统温度/电压问题
非严重情形,可能为下列状况:
冗余电源模块故障
系统温度/电压问题
机箱侵入
系统未正常运行,可能为下列状况:
POST错误
NMI错误
处理器或终结器缺失
SATA Connector/SATA 接口
No. Pin Define
1 GND
2 TXP
3 TXN
4 GND
7
1
No. Pin Define
5 RXN
6 RXP
7 GND
BMC Firmware Readiness LED
State Descripon
On BMC firmware is inial
Blink BMC firmware is ready
Off AC loss
BMC Firmware Readiness LED (LED_BMC):
CPU/System FAN/
14
4
1
No. Pin Define
1 GND
2 +12V
3 Sense
4 Speed Control
IPMB
No. Pin Define
1 Clock
2 GND
3 Data
31
Jumper Sengs/ 跳线设置
No. Desripon
1 Clear CMOS Jumper
1-2 Close: Normal operaon (Default seng)
2-3 Close: Clear CMOS data.
2 SATA Port 1 DOM Support Jumper Jumper
1-2 Close: Enable SATA port DOM support funon.
2-3 Close: Normal Operaon. (Default seng)
If a SATA type hard drive is connected to the
motherboard, please ensure the jumper is
closed and set to 2-3 pins (Default seng),
in order to reduce any risk of hard disk
damage.
1
2
Definition
P5V
SATA1 Pin7
3GND
Pin No.
Open: Normal operaon.
Closed: Acve chassis intruson alert.
Chassis Intrusion Alert Header
1
1
2 2
3
4
7
6
5
PN