Tascam SB-16D 取扱説明書

  • こんにちは!TASCAM SB-16D Danteステージボックスの取扱説明書を読みました。16チャンネルのアナログ入出力、Danteネットワーク対応、冗長電源など、このデバイスの機能についてご質問があれば、お気軽にお尋ねください。喜んでお手伝いさせていただきます。
  • SB-16Dの電源はどのように接続しますか?
    ファンタム電源はどのようにオン/オフしますか?
    Danteネットワークへの接続方法は?
    サンプリング周波数とビット深度はどのように変更しますか?
    工場出荷時の設定に戻すにはどうすればよいですか?
D01393500B
16in/16out Dante Stage Box
SB-16D
AD/DA Converter
OWNER’S MANUAL
MODE D’EMPLOI
MANUAL DEL USUARIO
BEDIENUNGSANLEITUNG
MANUALE DI ISTRUZIONI
取扱説明書
ENGLISHFRANÇAISESPAÑOLDEUTSCHITALIANO

oTASCAM is a registered trademark of TEAC Corporation.
oAudinate®, the Audinate logo and Dante are trademarks of
Audinate Pty Ltd.
www.audinate.com/patents
oOther company names, product names and logos in this
document are the trademarks or registered trademarks of
their respective owners.
2 TASCAM SB-16D
IMPORTANT SAFETY INSTRUCTIONS
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightning ash with arrowhead symbol, within equilateral triangle, is intended to alert the
user to the presence of uninsulated dangerous voltage within the product’s enclosure that may
be of sucient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence
of important operating and maintenance (servicing) instructions in the literature accompanying
the appliance.
CAUTION: Risk of electric shock. To completely cut o the power supply to the unit, always
disconnect all power sources.
ATTENTION: Risque d’électrocution. Pour couper complètement l’alimentation de l’unité,
débranchez toujours toutes les sources d’alimentation.
WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT
EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
For U.S.A.
Supplier's Declaration of Conformity
Model Number: SB-16D
Trade Name: TASCAM
Responsible party: TEAC AMERICA, INC.
Address: 10410 Pioneer Blvd., Unit #1, Santa
Fe Springs, California 90670, U.S.A
Telephone number: 1-323-726-0303
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may
cause undesired operation.
INFORMATION TO THE USER
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by
turning the equipment o and on, the user is encouraged to
try to correct the interference by one or more of the following
measures.
a) Reorient or relocate the receiving antenna.
b) Increase the separation between the equipment and
receiver.
c) Connect the equipment into an outlet on a circuit dierent
from that to which the receiver is connected.
d) Consult the dealer or an experienced radio/TV technician
for help.
CAUTION
Changes or modications to this equipment not expressly
approved by TEAC CORPORATION for compliance could void
the users authority to operate this equipment.
IN USA/CANADA, USE ONLY ON 120 V SUPPLY.
For Canada
THIS CLASS B DIGITAL APPARATUS COMPLIES WITH CANADIAN
ICES-003.
CET APPAREIL NUMERIQUE DE LA CLASSE B EST CONFORME A
LA NORME NMB-003 DU CANADA.
This product complies with the European
Directives request and the other Commission
Regulations.
This product complies with applicable UK
regulations.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance
with the manufacturers instructions.
8. Do not install near any heat sources such as radiators, heat
registers, stoves, or other apparatus (including ampliers)
that produce heat.
9. Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades with
one wider than the other. A grounding type plug has two
blades and a third grounding prong. The wide blade or the
third prong are provided for your safety. If the provided
plug does not t into your outlet, consult an electrician for
replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched
particularly at plugs, convenience receptacles, and the
point where they exit from the apparatus.
ENGLISH
TASCAM SB-16D 3
OWNER’S MANUAL
11. Only use attachments/accessories specied by the
manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table
specied by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/
apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when
unused for long periods of time.
14. Refer all servicing to qualied service personnel. Servicing
isrequired when the apparatus has been damaged in any
way, such as power-supply cord or plug is damaged, liquid
has been spilled or objects have fallen into the apparatus,
the apparatus has been exposed to rain or moisture, does
not operate normally, or has been dropped.
i The apparatus draws nominal non-operating power from the
AC outlet with its POWER or STANDBY/ON switch not in the
ON position.
i The mains plug is used as the disconnect device, the
disconnect device shall remain readily operable.
i If you are experiencing problems with this product, contact
TEAC for a service referral. Do not use the product until it has
been repaired.
WARNING
i Products with Class 1 construction are equipped with a
power supply cord that has a grounding plug. The cord of
such a product must be plugged into an AC outlet that has
a protective grounding connection.
CAUTION
i Do not expose this apparatus to drips or splashes.
i Do not place any objects lled with liquids, such as vases,
on the apparatus.
i Do not install this apparatus in a conned space such as a
book case or similar unit.
i The apparatus should be located close enough to the AC
outlet so that you can easily grasp the power cord plug at
any time.
i If the product uses batteries (including a battery pack
or installed batteries), they should not be exposed to
sunshine, re or excessive heat.
i CAUTION for products that use replaceable lithium
batteries: there is danger of explosion if a battery is
replaced with an incorrect type of battery. Replace only
with the same or equivalent type.
CAUTION
i DO NOT REMOVE THE EXTERNAL CASES OR CABINETS TO
EXPOSE THE ELECTRONICS. NO USER SERVICEABLE PARTS
ARE INSIDE.
i IF YOU ARE EXPERIENCING PROBLEMS WITH THIS PRODUCT,
CONTACT THE STORE WHERE YOU PURCHASED THE UNIT FOR
A SERVICE REFERRAL. DO NOT USE THE PRODUCT UNTIL IT
HAS BEEN REPAIRED.
i USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF
PROCEDURES OTHER THAN THOSE SPECIFIED HEREIN MAY
RESULT IN HAZARDOUS RADIATION EXPOSURE.
The nameplate is located on the top of the unit as shown below.
Front side
Nameplate
RACK-MOUNTING THE UNIT
Use the supplied rack-mounting kit to mount the unit in a
standard 19-inch rack, as shown below.
Remove the feet of the unit before mounting.
ATTENTION
iLeave 1U of space above the unit for ventilation.
iAllow at least 10 cm (4 in) at the rear of the unit for
ventilation.
4 TASCAM SB-16D
For European Customers
Disposal of electrical and electronic equipment and
batteries and/or accumulators
(a) All electrical/electronic equipment and waste batteries/
accumulators should be disposed of separately from the
municipal waste stream via collection facilities designated
by the government or local authorities.
(b) By disposing of electrical/electronic equipment and
waste batteries/accumulators correctly, you will help save
valuable resources and prevent any potential negative
eects on human health and the environment.
(c) Improper disposal of waste electrical/electronic equipment
and batteries/accumulators can have serious eects on the
environment and human health because of the presence
of hazardous substances in the equipment.
(d) The Waste Electrical and Electronic Equipment
(WEEE) symbols, which show wheeled bins that
have been crossed out, indicate that electrical/
electronic equipment and batteries/accumulators
must be collected and disposed of separately
from household waste.
If a battery or accumulator contains more than
the specied values of lead (Pb), mercury (Hg),
and/or cadmium (Cd) as dened in the Battery
Directive (2006/66/EC, 2013/56/EU), then the
chemical symbols for those elements will be
indicated beneath the WEEE symbol.
Pb, Hg, Cd
(e) Return and collection systems are available to end users.
For more detailed information about the disposal of old
electrical/electronic equipment and waste batteries/
accumulators, please contact your city oce, waste
disposal service or the shop where you purchased the
equipment.
For China
“仅适用于海拔2000m以下地区安全使用”
“仅适用于非熱帯气候条件下安全使用”
“环境保护使用年限”
产品有毒有害物质或元素的名称及含量
机种: SB-16D 有毒有害物质或元素
品名
(Pb)
(Hg)
(Cd)
六价铬
(Cr6+)
多溴联苯
(PBB)
多溴二苯醚
(PBDE)
1 CHASSIS部分 ○ ○ ○ ○ ○
2 FRONT PANEL部分
3 螺丝部分 ○ ○ ○ ○ ○
4 线材部分 ○ ○ ○ ○ ○
5 PCB Assy部分 ×
6 电源部分 × ○ ○ ○ ○
7 附属品部分 × ○ ○ ○ ○
8 LABEL部分 ○ ○ ○ ○ ○
9 包装部分 ○ ○ ○ ○ ○
表示该有毒有害物质在该部件所有均质材料中的含有量均在 GB/T26572 标准规定的限量要求以下。
× 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 GB/T26572标准规定的限量要求。
(针对现在代替技术困难的电子部品及合金中的铅)
ENGLISH
TASCAM SB-16D 5
Introduction
Thank you very much for purchasing the TASCAM SB-16D
16in/16out Dante Stage Box.
Before using this unit, read this Owners Manual carefully so that
you will be able to use it correctly and enjoy working with it for
many years. After you have nished reading this manual, please
keep it in a safe place for future reference.
You can also download this Owners Manual from the TASCAM
website.
SB-16D
https://tascam.jp/int/product/sb-16d/docs
Features
o Supports 16 channels of analog line/mic inputs
o Supports 16 channels of analog line/mic outputs
o Supports remote control using the dedicated TASCAM IO
CONTROL application
i Gain control
i Phantom power on/o
i PAD on/o
i Other functions
o Dante included as a standard feature with support for
redundancy
o AES67 is also supported, so connection is possible with
Ravenna and other compatible network audio technologies
o Flexible routing is possible using Dante Controller
o Support for sampling frequencies and bit lengths up to
96kHz and 32-bit
o Inputs have phantom power, signal and overload LEDs
o Outputs have signal LEDs
o Supports redundant power input with AC and DC power
supplies
o Reference level can be set
o 3U rackmount size
Contente
IMPORTANT SAFETY INSTRUCTIONS ..................................... 3
Introduction ............................................................................. 6
Features .................................................................................... 6
Included items ......................................................................... 7
Conventions used in this manual ........................................... 7
Precautions for placement and use ........................................ 7
Notes about power supplies ................................................... 7
Beware of condensation ......................................................... 7
Cleaning the unit ..................................................................... 7
About TASCAM customer support service ............................. 7
Names and functions of parts ................................................ 8
Front panel ...............................................................................................8
Rear panel .................................................................................................9
Left side panel .........................................................................................9
Attaching the rackmount ears ..............................................10
Connecting the power ...........................................................11
Starting up when operating with only DC power supply..... 11
Notes about the DC POWER indicator ......................................... 11
Application overview ............................................................11
Overview of settings .............................................................11
Setting mic/line inputs ...................................................................... 11
Setting phantom power ................................................................... 11
Setting the reference level ............................................................... 11
Device ID settings .................................................................. 12
Checking the device ID ..................................................................... 12
Changing the device ID .................................................................... 12
Restoring factory default settings ....................................... 13
Using as a Sonicview extension ............................................13
Notes about Dante ................................................................13
Connecting to a Dante network ...........................................13
Switched (daisy chain) connection ............................................... 13
Redundant connection ..................................................................... 14
Using Dante Controller .........................................................14
Dante Controller overview ............................................................... 14
Audio routing settings ...................................................................... 14
Changing sampling frequencies and bit depths with Dante
Controller ............................................................................................... 15
Control parameters ............................................................... 16
Parameter list ........................................................................................ 16
GPIO connector overview ................................................................ 16
Specications and rated values ............................................17
Audio performance ............................................................................ 17
Inputs and outputs ............................................................................. 17
Other ........................................................................................................ 17
Dimensional drawings ..........................................................98
Software Licensing ................................................................ 99
6 TASCAM SB-16D
Included items
This product includes the following items.
Take care when opening the package to avoid damaging the
items. Keep the packing materials for transportation in the
future.
Please contact the store where you purchased this unit if any
of these items are missing or have been damaged during
transportation.
o Main unit ................................................................................................x 1
o Power cords (for Japan/USA, Europe and Oceania) ................x 3
o Rackmount ear (with installation screws) set ...........................x 1
o Rackmount screw kit .......................................................................... x 1
o TASCAM ID registration guide ........................................................x 1
o Owners Manual (this document) including warranty ...........x 1
Conventions used in this manual
In this manual, we use the following conventions:
o Additional information is introduced in the styles below
when needed:
TIP
These are tips about how to use the unit.
NOTE
These provide additional explanations and describe special
cases.
ATTENTION
Failure to follow these instructions could result in damage to
equipment or lost data, for example.
VCAUTION
Failure to follow these instructions could result in injury.
Precautions for placement and use
o The operating temperature range of this unit is 0 - 40 °C.
o Do not install this unit in the following types of locations.
Doing so could make the sound quality worse or cause
malfunction.
Places with signicant vibrations
Next to a window or in another location exposed to direct
sunlight
Near heaters or other extremely hot places
Extremely cold places
Very humid or poorly ventilated places
Very dusty places
o Do not block the ventilation ports, which dissipate heat, on
the back and sides of the unit.
o To enable good heat dissipation, do not place anything on
top of the unit.
o Do not place the unit on top of a power amplier or other
device that generates heat.
Notes about power supplies
o Insert the included power cord all the way into the AC IN
connector.
o Only connect a power supply that is AC100-240V (50/60Hz)
to the AC IN connector.
o Only connect a power supply that is DC 11V–27V to the EXT
DC IN connector. Use a power supply that has a 11V–27V
Limited Power Source (LPS) rating for output voltage with the
EXT DC IN connector.
o Hold the power cord by its plug when connecting or
disconnecting it.
ATTENTION
If you want to completely cut o the power supply to the
stagebox, always remember to disconnect it from both
power sources.
NOTE
This product includes 3 types of power cords. Use the power
cord that matches the type of power outlet being used.
Beware of condensation
Condensation could occur if the unit is moved from a cold place
to a warm place, it is used immediately after a cold room has
been heated or it is otherwise exposed to a sudden temperature
change.
To prevent this, or if this occurs, let the unit sit for one or two
hours at the new room temperature before using it.
Cleaning the unit
Use a dry soft cloth to wipe the unit clean. Do not wipe
with chemical cleaning cloths, thinner, alcohol or other
chemical agents. Doing so could damage the surface or cause
discoloration.
About TASCAM customer support
service
TASCAM products are supported and warrantied only in their
country/region of purchase.
To receive support after purchase, on the TASCAM Distributors
list page of the TEAC Global Site (https:// teac-global.com/),
search for the local company or representative for the
region where you purchased the product and contact that
organization.
When making inquiries, the address (URL) of the shop or
web shop where it was purchased and the purchase date are
required.
Moreover, the warranty card and proof of purchase might also
be necessary.
ENGLISH
TASCAM SB-16D 7
Names and functions of parts
Front panel
1Analog input connectors
These analog inputs are balanced XLR jacks.
i XLR (1: GND, 2: HOT, 3: COLD)
2INPUT SIG indicators
48V Indicators
These light when phantom power is on.
INPUT SIG indicators
These light when sound is being input through the
analog inputs.
Input is judged to have occurred when the signal level
exceeds -40 dBFS.
OL indicators
These light when analog input signals overload.
3OUTPUT SIG indicators
These light when sound is being output through the analog
outputs.
Output is judged to have occurred when the signal level
exceeds -40 dBFS.
4Analog output connectors
These analog outputs are XLR jacks.
i XLR (1: GND, 2: HOT, 3: COLD)
5DC POWER indicator
i This indicator will light when a DC power supply is
connected.
i This will blink to show that voltage is low when it
approaches the threshold voltage value set in advance on
the Sonicview 16/24 or using the TASCAM IO CONTROL
app.
See “Connecting the power” on page 11 for details.
6DC POWER button
i When operating only with DC power, press and hold this
button to turn the power on/o.
i Using this button is unnecessary when operating with AC
power because it will start up automatically.
See “Connecting the power” on page 11 for details.
7STATUS indicator
The STATUS indicator shows the state of the unit by lighting
blue or red or staying unlit.
See “STATUS indicator lighting status details” on page 8
for details.
8ID button
The device ID setting of this unit can be checked and
changed.
See “Device ID settings” on page 12 for setting procedures.
9SAMPLE RATE indicators
The lighting of the two SAMPLE RATE indicators (48 kHz/96
kHz) shows the sampling frequency state of the unit.
0PRIMARY/SECONDARY indicators
These light to show the Dante network status.
Communication is at 1 Gbps when lit and at 100 Mbps when
blinking.
STATUS indicator lighting status details
STATUS indicator Note
Ordinary operation Lit blue The unit is operating normally.
Malfunctioning (Dante) Rapidly ashing red (four times per second) The Dante module is malfunctioning.
Muted Lit red
The indicator lights red when the clock is stabilizing
after the unit starts up and when the sampling
frequency or other Dante setting has been changed,
for example.
Dante network error Flashing red (twice per second) The Dante network is not connected.
Dante redundancy error Blinking blue (once per second) The Dante PRIMARY connector is disconnected or
another error with redundant connection has occurred.
8 TASCAM SB-16D
STATUS indicator Note
Update mode Blinking blue/red (once per second) The unit rmware is being updated.
Checking device ID
STATUS/SAMPLE RATE indicators and, according
to device ID number, OUTPUT channel LEDs blink
(once per second)
This is the state when the device ID set in the unit is
being shown.
Changing device ID
STATUS/SAMPLE RATE indicators and, according
to device ID number, OUTPUT channel LEDs blink
(twice per second)
This is the state when the device ID set in the unit is
being changed.
Safe mode STATUS/SAMPLE RATE/PRIMARY/SECONDARY LEDs
blink (once per second) The unit is in safe mode.
Rear panel
qRESET button
Pressing the RESET button while the unit is powered and
operating will restore network address settings and all other
unit settings to their factory defaults. (see “Restoring factory
default settings” on page 13)
wGPIO connector
This is a 25-pin D-sub Parallel control input/output
connector.
Use this to connect an external controller. (see “Dante
Controller overview on page 14)
Left side panel
eAC IN connector
Connect the included power cord here.
rEXT DC IN connector
Connect external DC power here.
Use a power supply that has a 11V -27V Limited Power
Source (LPS) rating for output voltage with the EXT DC IN
connector.
The connector is XLR-4-32 equivalent (1: –, 2: NC, 3: NC, 4: +).
tPRIMARY connector
This is the main etherCON Cat5e-compatible Dante
transmission connector.
Use this to connect to a Dante network all the time.
ySECONDARY connector
This is the secondary etherCON Cat5e-compatible Dante
transmission connector. The use changes depending on the
mode.
When in redundant mode, this connects to the secondary
Dante network.
When in switched (daisy chain) mode, use to connect
another Dante device in the chain.
ENGLISH
TASCAM SB-16D 9
Attaching the rackmount ears
Before mounting this unit in a 19 inch rack, you must replace the
feet with the included rackmount ears. Follow these procedures
to attach the rackmount ears. (Prepare a Phillips screwdriver in
advance.)
1. Remove the 4 attached screws as shown in the illustration
below, and remove the 4 feet from the ends of the unit.
2. Attach the included rackmount ears to the unit using the
included rackmount ear installation screws.
NOTE
iReverse these procedures to reinstall the feet that were
originally attached to the unit.
iBy changing the attachment positions of the rackmount
ears, the unit can be mounted in a rack with its front panel
recessed by 20, 40 or 60 mm.
Furthermore, the rackmount ears can be attached
backwards.
10 TASCAM SB-16D
Connecting the power
This unit has AC IN and EXT DC IN connectors, enabling
redundant power connection.
When both AC and DC power supplies are connected, the unit
will switch to the DC power supply if the AC power supply is cut,
preventing sound from being interrupted.
To use power supplies, connect them to the AC IN and EXT DC
IN jacks.
The unit can be used with power supplied to just one connector
or to both connectors simultaneously.
Starting up when operating with only DC
power supply
When operating with only DC power supply, the unit will not
start up just by supplying the power.
Press and hold the DC POWER (6) button for 5 seconds to start
the unit. To turn the unit o, press and hold the DC POWER (6)
button for 5 seconds.
NOTE
The unit will stay on when AC power is supplied. Moreover,
pressing and holding the DC POWER (6) button for 5
seconds will not shut down the unit.
Notes about the DC POWER indicator
o The DC POWER indicator (5) lights when the unit is on and
DC power is being supplied.
o This will become unlit when the DC power supply is less than
the set stop voltage. This will also be unlit when the unit is o.
o This will blink when below the set alert voltage.
o The stop voltage can be set between 11.0 V and 27 V in 0.1V
intervals. Set the stop voltage to the specications of the battery
that is supplying DC power. Set the stop voltage to 11.0 V when
the stop voltage specication is unknown or when using power
supplies other than batteries (including AC adapters).
o The alert voltage is set by default to a value that is 0.5 V
higher than the stop voltage. Adjust this setting as necessary
if the alert is shown too quickly or too late. The alert can also
be turned o.
o The stop voltage and alert voltage settings can be made
using external control by remote protocol, from the
Sonicview unit or from the TASCAM IO CONTROL app. Refer
to the following documents for details.
i SB-16D remote control specications
i Sonicview Series Reference Manual
i TASCAM IO CONTROL app operation manual
Application overview
Using the TASCAM IO CONTROL application, the unit can be
operated and its functions can be set remotely.
For details about the application, please see its Owners Manual.
The TASCAM IO CONTROL application and its operation manual
can be downloaded from the TEAC Global Site (https://teac-
global.com/).
For details about function that can be set, see “Parameter list” on
page 16.
Overview of settings
Make various settings as necessary according to the connected
equipment.
The following settings can all be made using the TASCAM IO
CONTROL application. In addition, when used together with a
Sonicview, various settings can be made from the Sonicview.
See “Using as a Sonicview extension on page 13 for details.
Setting mic/line inputs
Mic and line input settings can be made.
Gain, pad and trim settings can also be made in these input
settings.
Setting phantom power
Phantom power can be turned on when an external mic that
requires it is connected to the unit.
This can be turned on/o independently for each channel.
ATTENTION
iBefore connecting condenser mics, turn this unit and all
equipment to be connected o (standby).
iDo not connect or disconnect mics while phantom power
is on. Doing so could cause a loud noise and might damage
this unit and connected equipment.
iTurn phantom power ON only when using a condenser
microphone that requires phantom power. Turning phantom
power on when a dynamic mic or other mic that does not
require it is connected could damage this unit and connected
equipment.
iSupplying phantom power to some ribbon mics could break
them. If unsure about a ribbon mic, conrm with the mic
manufacturer or do not supply phantom power to it.
Setting the reference level
You can set the analog input and output headroom (dierence
between the maximum and reference levels).
ENGLISH
TASCAM SB-16D 11
Device ID settings
When using an SB-16D with a Sonicview 16/24, the device ID must be set to enable identication of the unit.
Follow the procedures below to check or change the device ID.
Checking the device ID
Press the ID (8) button.
The unit will enter device ID checking mode, and the STATUS and SAMPLE RATE indicators will blink.
INPUT SIG indicators and OUTPUT SIG indicators will light at the same time according to the device ID number.
The device ID is assigned by pairing the numbers of the input and output channel indicators.
For example, indicators will light for the following ID numbers as shown in the tables.
Device ID: #3-4
Channel number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
INPUT SIG indicators 0
OUTPUT SIG indicators 0
Device ID: #15-8
Channel number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
INPUT SIG indicators 0
OUTPUT SIG indicators 0
i Indicators that light when in device ID conrmation mode
Changing the device ID
Follow the procedures below to change the device ID.
ATTENTION
Be careful to set the device ID for this unit so that it is not the same as another SB-16D connected to the same network.
1. Press and hold the ID (8) button for 10 seconds.
The STATUS and SAMPLE RATE indicators will light simultaneously along with OUTPUT SIG indicators according to the device ID
number (twice per second).
2. When in device ID changing mode, press the ID (8) button to change the device ID.
The blinking OUTPUT SIG indicator will change.
3. Press and hold the ID (8) button for 2 seconds to conrm.
After entering device ID changing mode, each time the ID (8) button is pressed, the device ID will be increased by one (+1). The
blinking OUTPUT SIG indicator will also change in order according to the device ID number.
After the OUTPUT SIG indicator reaches 16, pressing the ID (8) button again will return to OUTPUT SIG indicator 1.
ATTENTION
When changing the device ID with this unit, changes with OUTPUT SIG indicators 1–16 are possible.
To change INPUT SIG indicators, do so from a Sonicview 16/24 or using the TASCAM IO CONTROL application.
12 TASCAM SB-16D
Restoring factory default settings
Pressing the RESET (q) button while the unit is powered and
operating will reset network address settings and all other unit
settings to their factory defaults.
Resetting Dante settings
Press and hold the RESET (q) button for 5 seconds.
The STATUS indicator will blink 2 times and the network address
and other settings for Dante will be restored to their default
values.
Resetting all settings made in the unit
Press and hold the RESET (q) button for 10 seconds.
The STATUS indicator will blink 3 times and all settings made in
the unit will be restored to their default values.
Launching the unit in safe mode
Connect a power supply while pressing the RESET (q) button.
This will start the unit in safe mode. The STATUS, SAMPLE RATE,
PRIMARY and SECONDARY indicators will blink twice per second.
Using as a Sonicview extension
By connecting this unit to the LAN of a Dante port in a TASCAM
Sonicview Series unit, this unit can be controlled from that
Sonicview. Moreover, mounting this unit on the TASCAM
Sonicview Series unit enables its analog inputs to be operated in
the same way as the analog inputs of the Sonicview.
Use the following procedures to mount it.
NOTE
iThese procedures assume that the Dante Control network
settings of this unit and the TASCAM Sonicview Series unit
are set to their defaults (Addressing is AUTO).
iA Sonicview can mount a maximum of 4 units.
1. Connect mics, speakers and other equipment with analog
connectors.
2. Connect the Dante ports of this unit and the Sonicview
Series unit with a LAN cable.
If the Dante setting for both devices is redundant mode,
connect the corresponding PRIMARY and SECONDARY
connectors of both units together.
See “Switched (daisy chain) connection” on page 13 and
“Redundant connection” on page 14 for connection
instructions.
3. Turn o the power of equipment connected to this unit.
4. Make the Dante routing setting.
By mounting this unit from the Sonicview unit, the Dante
routing between them will be set automatically. Moreover,
sampling rate, reference level, Dante latency and other
settings will automatically be set to suitable values.
For details, see the Reference Manual of the Sonicview
Series unit.
5. Make the Sonicview Series unit input and output routing
settings.
For details, see “5 – Routing” in the Reference Manual of the
Sonicview Series unit.
Notes about Dante
Dante is a transmission protocol developed by Audinate.
Using networks based on gigabit Ethernet standards, it enables
multichannel (512 IN/512 OUT) transmission and high precision,
for example.
Check the Audinate website for details about Dante.
https://www.audinate.com/
Connecting to a Dante network
In order to set up and use this card, you must also set up the
Ethernet network that it is connected to, a computer that runs
Dante Controller and other devices that support Dante.
LAN cables used for connections
Use STP cables that are category 5e or higher.
Both crossover and straight cables can be used.
ATTENTION
This unit is not compatible with 100Mbps Ethernet switching
hubs. Always use switching hubs that support Gigabit
Ethernet.
NOTE
iWhen the Dante Network Addressing setting is AUTO (DHCP),
set the computer to set the IP address automatically.
iWhen the Dante Network Addressing setting is STATIC, set
the computer to match the Dante and network address.
Switched (daisy chain) connection
Dante devices can be daisy-chained when there are few
connected devices and when not using a switching hub.
Connect them as shown below.
Switched (daisy chain) connection example
SB-16D SB-16D
Mixer
NOTE
iWhen using a switched (daisy chain) connection, connect to
either the PRIMARY or SECONDARY connector.
iIf the number of connected devices increases, raising the
latency setting will be necessary.
ENGLISH
TASCAM SB-16D 13
Redundant connection
For recording situations where retakes are not possible,
including live performances, a connection set up like the
following uses two completely independent primary and
secondary networks.
Redundant connection example
SB-16D
HUB
PC
HUB
SB-16D
Primary Secondary
Mixer
NOTE
Settings for switched (daisy chain) and redundant
connections do not change automatically. Change the
settings on the Dante Controller Network Cong screen.
ATTENTION
The primary and secondary networks can never be
connected to each other by the same LAN (VLAN).
Hub
Primary
Secondary
Using Dante Controller
Dante Controller overview
This unit uses the Dante Controller application, which is
available at the Audinate website, to connect with other devices
that support Dante.
Download the latest version of the Dante Controller application
and an operation manual from the Audinate website.
Audinate download page
https://www.audinate.com/products/software/dante-
controller
Make at least the following settings using a computer that has
Dante Controller installed.
o Set the audio routing.
o Adjust the sampling frequency and bit depth of each Dante
device.
NOTE
Settings made using Dante Controller are stored in the built-
in memory of each Dante device.
Unless settings are modied, connections will not
change even if Dante Controller is quit or the computer is
disconnected from the Dante network.
Audio routing settings
When Dante Controller is launched, the Network View screen
shown below will open.
On this screen, you can set and monitor conditions related to
the Dante network.
1Receiving device name
This is the name of a receiving device on the Dante network.
2Receiving device channels
These are the names of the channels of the receiving device
on the Dante network.
3Transmitting device name
This is the name of a transmitting device on the Dante
network.
4Transmitting device channels
These are the names of the channels of the transmitting
device on the Dante network.
14 TASCAM SB-16D
5Audio routing
Route the audio channels of the transmitting and receiving
devices that you want to connect here.
Click the intersection of the channels you want to connect
on the matrix to connect them.
NOTE
While pressing the computer keyboard Ctrl key, click the “-” at
the intersection of device names to connect all connectable
channels at once.
Changing sampling frequencies and bit
depths with Dante Controller
Double-click a device name on the Network View screen to open
the Device View screen.
On this screen, you can set and monitor conditions related to
devices on the Dante network.
Click the Device Cong tab to open the page where you can
change the sampling frequency, bit rate and other settings of
the device selected in 1 shown in the illustration below.
1Device name
This is the name of the device that can have its settings
changed in the current Device View.
2Change device name
Edit the device name.
3Sampling frequency
Set the sampling frequency.
4Bit depth
Set the bit depth.
5Latency setting
Set the latency.
ATTENTION
Changing the name of a device will clear audio routing
settings. For this reason, we recommend changing device
names to names that are easy to identify before setting audio
routings.
ENGLISH
TASCAM SB-16D 15
Control parameters
Parameter list
This unit has the following parameters.
They can all be controlled using a dedicated app and from a TASCAM Sonicview Series unit.
Function Notes
Head Amp GAIN adjustment
When Analog Reference Level = +6 dBu
When PAD OFF: +12 dB – +66 dB
When PAD ON: -8 dB – +46 dB
When Analog Reference Level = +4 dBu
When PAD OFF: +3 dB – +57 dB
When PAD ON: -17 dB – +37 dB
When Analog Reference Level = 0 dBu
When PAD OFF: +8 dB – +62 dB
When PAD ON: -12 dB – +42 dB
PAD ON/OFF -20 dB when on
PHANTOM ON/OFF +48V when on
Sampling rate setting 96 kHz (default)/48 kHz
Device name setting Set/change the device name as desired
Channel label settings Set/change channel names as desired
Switching the reference level Digital reference level settings -9 dBFs/-14 dBFs/-16 dBFs/-18 dBFs/-20dBFs (default)
Analog reference level settings +6dBu (when -9dBFs)/+4dBu (default)/+0dBu
Indicator brightness adjustment Setting range: 0–3 (default) (in 1 ms steps)
Identify Makes all SIG and STATUS indicators on the unit blink
Network settings
(Dante Primary/Dante
Secondary/SB-16D unit)
Static/Auto (DHCP) Automatic acquisition/manual setting for IP address
IP Address IP address can be set/changed when “Static”
Subnet Mask Subnet Mask can be set/changed when “Static
Password setting Set/change password as desired (no password by default)
GPIO setting Set/change function assigned to GPIO connector
Preset setting Set presets
GPIO connector overview
The GPIO connector on the back is a parallel control connector
for conducting external control of this unit.
In addition to external control of the SB-16D, GPIO connector
functions can also be set for use as extensions of the TASCAM
digital mixer GPIO connector. These can be set using the
TASCAM IO CONTROL app or a TASCAM digital mixer that
supports connection with this unit.
To use this unit by itself, see “GPIO settings” in the TASCAM IO
CONTROL reference manual.
When connected to a TASCAM Sonicview Series unit, this can be
done on the GPIO-IN and GPIO-OUT pages of the USER DEFINED
CONTROLS screen. For details, see “GPIO-IN page and “GPIO-
OUT page” in “4 – Mixer conguration and other settings” of the
Reference Manual for the Sonicview Series unit.
The pin assignments are as follows.
Pin No. Function IN/OUT
1 GND -
2 GPIO IN 2 IN
3 GPIO IN 4 IN
4 GPIO IN 6 IN
5 GPIO IN 8 IN
6 NC -
7 NC -
8 NC -
9 GPIO OUT 2 OUT
10 GPIO OUT 4 OUT
Pin No. Function IN/OUT
11 GPIO OUT 6 OUT
12 GPIO OUT 8 OUT
13 NC -
14 GPIO IN 1 IN
15 GPIO IN 3 IN
16 GPIO IN 5 IN
17 GPIO IN 7 IN
18 NC -
19 NC -
20 GND -
21 GPIO OUT 1 OUT
22 GPIO OUT 3 OUT
23 GPIO OUT 5 OUT
24 GPIO OUT 7 OUT
25 +5V -
IN: For command input
i Internal circuit with +5V pull-up
i Operates with low signal input of 50 msec or longer
OUT: For command and tally output
i Internal circuit is open collector (10Ω output impedance)
i 20V dielectric strength, 35mA maximum current
+5V: 50mA maximum supplied current
16 TASCAM SB-16D
Specications and rated values
Audio performance
0 dBu = 0.775 Vrms
Mic amp EIN (equivalent input noise)
-128 dBu or less
Frequency response
MIC/LINE IN to DANTE OUT
20 Hz - 20 kHz: +0 dB, -0.5 dB (48 kHz) (JEITA)
20 Hz - 40 kHz: +0 dB, -1.0 dB (96 kHz) (JEITA)
DANTE IN to LINE OUT
20 Hz - 20 kHz: +0 dB, -0.5 dB (48 kHz) (JEITA)
20 Hz - 40 kHz: +0 dB, -1.0 dB (96 kHz) (JEITA)
Dynamic range
110 dB or more ( MIC/LINE to DANTE, PAD = OFF, A.Ref = +4
dBu, GAIN = 12, JEITA)
111 dB or more ( DANTE to LINE OUT, 48 kHz sampling
frequency)
112 dB or more ( DANTE to LINE OUT, 96 kHz sampling
frequency)
Distortion
0.002% or less ( MIC/LINE IN to DANTE, Input at +4 dBu, PAD =
OFF, A.Ref = +4 dBu, GAIN = 12, JEITA)
0.002 % or less (DANTE to LINE OUT, Output at 0 dBFS, JEITA)
Crosstalk
100 dB or more (MIC/LINE to LINE OUT, 1 kHz sine wave, JEITA)
A.Ref: Analog Reference Level setting
Inputs and outputs
INPUT 1–16 jacks
Connectors: XLR-3-31 equivalent (1: GND, 2: HOT, 3: COLD)
Input levels:
Pad o
Maximum input level: +12 dBu (TRIM at minimum)
Minimum input level: −62 dBu (TRIM at maximum)
Pad on
Maximum input level: +32 dBu (TRIM at minimum)
Minimum input level: -42 dBu (TRIM at maximum)
Input impedance: 5.0 kΩ or higher
NOTE
+48V phantom power can be supplied to each MIC/ LINE
input jack separately.
OUTPUT 1-16 jacks
Connectors: XLR-3-32 equivalent (1: GND, 2: HOT, 3: COLD)
Output impedance: 100 Ω
Nominal output level:
+6 dBu (D.Ref: -9 dBFS, A.Ref:+6 dBu)
+4 dBu (D.Ref: -14/-16/-18/-20 dBFS, A.Ref: +4 dBu)
0 dBu (D.Ref: -18/-20 dBFS, A.Ref: 0 dBu)
Maximum output level:
+15 dBu (D.Ref: -9 dBFS, A.Ref: +6 dBu)
+18 dBu (D.Ref: -18 dBFS, A.Ref: 0 dBu)
+20 dBu (D.Ref: -20 dBFS, A.Ref: 0 dBu)
+18 dBu (D.Ref: -14 dBFS, A.Ref: +4 dBu)
+20 dBu (D.Ref: -16 dBFS, A.Ref: +4 dBu)
+22 dBu (D.Ref: -18 dBFS, A.Ref: +4 dBu)
+24 dBu (D.Ref: -20 dBFS, A.Ref: +4 dBu)
D.Ref: Digital Reference Level setting
A.Ref: Analog Reference Level setting
Dante PRIMARY/SECONDARY connectors
Connector: etherCON Cat5e compatible connector*
Transmission protocol: Dante
Gigabit Ethernet standard: 1000BASE-T (IEEE 802.3ab)
Cables: category 5e or faster STP cables
* etherCON is a registered trademark of Neutrik AG.
GPIO connector
Connector: 25-pin D-sub (8-in/8-out, female, inch-standard)
i See “GPIO connector overview on page 16 for details
about GPIO connector and assignments.
Other
Power
AC 100-240V, 50/60Hz
External power supply (DC 11-27V/4-2A)
i DC voltage/current range: 11V/4A − 27V/2A
Power consumption
44W
Dimensions
With standard feet attached
4540. × 179.6 × 140.0mm (W × H × D)
With rackmount ears attached
482.8 × 132.0 × 120.0mm (W × H × D)
Weight
4.5 kg
Operating temperature range
0 - 40°C (32 - 104°F)
o Illustrations in this manual might dier in part from the
actual product.
o Specications and external appearance might be changed
without notication to improve the product.
ENGLISH
TASCAM SB-16D 17
INSTRUCTIONS DE SÉCURITÉ IMPORTANTES
ATTENTION: POUR RÉDUIRE LE RISQUE D’ÉLECTROCUTION, NE RETIREZ PAS LE CAPOT (OU
LARRIÈRE). AUCUNE PIÈCE INTERNE N’EST RÉPARABLE PAR L’UTILISATEUR. CONFIEZ TOUTE
RÉPARATION À UN SERVICE APRÈS-VENTE QUALIFIÉ.
Le symbole d’éclair à tête de èche dans un triangle équilatéral sert à prévenir l’utilisateur de la
présence dans l’enceinte du produit d’une «tension dangereuse» non isolée d’une grandeur
susante pour constituer un risque d’électrocution pour les personnes.
Le point d’exclamation dans un triangle équilatéral sert à prévenir l’utilisateur de la présence
d’instructions importantes de fonctionnement et de maintenance (entretien) dans les documents
accompagnant l’appareil.
ATTENTION: Risque d’électrocution. Pour couper complètement l’alimentation de l’unité,
débranchez toujours toutes les sources d’alimentation.
AVERTISSEMENT: POUR PRÉVENIR LES RISQUES
D’INCENDIE ET D’ÉLECTROCUTION, N’EXPOSEZ PAS CET
APPAREIL À LA PLUIE NI À L’HUMIDITÉ.
AUX USA/CANADA, UTILISEZ UNIQUEMENT UNE TENSION
D’ALIMENTATION DE 120V.
Pour le Canada
CET APPAREIL NUMÉRIQUE DE LA CLASSE B EST CONFORME À
LA NORME NMB-003 DU CANADA.
Ce produit est conforme aux impératifs des
directives européennes et autres règlements de
la Commission.
1. Lisez ces instructions.
2. Conservez ces instructions.
3. Tenez compte de tous les avertissements.
4. Suivez toutes les instructions.
5. N’utilisez pas cet appareil avec de l’eau à proximité.
6. Nettoyez-le uniquement avec un chion sec.
7. Ne bloquez aucune ouverture de ventilation. Installez-le
conformément aux instructions du fabricant.
8. Ne l’installez pas près de sources de chaleur telles que
des radiateurs, bouches de chauage, poêles ou autres
appareils (y compris des amplicateurs) dégageant de la
chaleur.
9. Ne neutralisez pas la fonction de sécurité de la che
polarisée ou de terre. Une che polarisée a deux broches,
l’une plus large que l’autre. Une che de terre a deux
broches identiques et une troisième broche pour la mise à
la terre. La broche plus large ou la troisième broche servent
à votre sécurité. Si la che fournie n’entre pas dans votre
prise, consultez un électricien pour le remplacement de la
prise obsolète.
10. Évitez de marcher sur le cordon d’alimentation et de
le pincer, en particulier au niveau des ches, des prises
secteur, et du point de sortie de l’appareil.
11. N’utilisez que des xations/accessoires spéciés par le
fabricant.
12. Utilisez-le uniquement avec le chariot, socle, trépied,
support ou table spécié par le fabricant ou vendu avec
l’appareil. Si un chariot est utilisé, faites attention à ne pas
être blessé par un renversement lors du déplacement de
l’ensemble chariot/appareil.
13. Débranchez cet appareil en cas d’orage ou de non
utilisation prolongée.
14. Conez toute réparation à des techniciens de maintenance
qualiés. Une réparation est nécessaire si l’appareil a été
endommagé d’une quelconque façon, par exemple si le
cordon ou la che d’alimentation est endommagé, si du
liquide a été renversé sur l’appareil ou si des objets sont
tombés dedans, si l’appareil a été exposé à la pluie ou à
l’humidité, sil ne fonctionne pas normalement, ou s’il est
tombé.
L’appareil tire un courant nominal de veille de la prise secteur
quand son interrupteur POWER ou STANDBY/ON nest pas en
position ON.
La che secteur est utilisée comme dispositif de déconnexion
et doit donc toujours rester accessible.
Si vous rencontrez des problèmes avec ce produit, contactez
TEAC pour une assistance technique. N’utilisez pas le produit
tant qu’il n’a pas été réparé.
18 TASCAM SB-16D
MODE D’EMPLOI
AVERTISSEMENT
Les produits ayant une construction de Classe 1 sont
équipés d’un cordon d’alimentation avec une che de terre.
Le cordon d’un tel produit doit être branché dans une prise
secteur avec terre de sécurité.
ATTENTION
N’exposez pas cet appareil aux gouttes ni aux
éclaboussures.
Ne placez pas d’objet rempli de liquide sur l’appareil,
comme par exemple un vase.
N’installez pas cet appareil dans un espace conné comme
une bibliothèque ou un meuble similaire.
L’appareil doit être placé susamment près de la prise de
courant pour que vous puissiez à tout moment attraper
facilement la che du cordon d’alimentation.
Si le produit utilise des piles/batteries (y compris un pack
de batteries ou des batteries xes), elles ne doivent pas être
exposées au soleil, au feu ou à une chaleur excessive.
PRÉCAUTION pour les produits qui utilisent des batteries
remplaçables au lithium : remplacer une batterie par
un modèle incorrect entraîne un risque d’explosion.
Remplacez-les uniquement par un type identique ou
équivalent.
ATTENTION
N’EXPOSEZ PAS L’ÉLECTRONIQUE EN OUVRANT LE BOÎTIER
OU SES CAPOTS. AUCUNE PIÈCE INTERNE N’EST RÉPARABLE
PAR L’UTILISATEUR.
SI VOUS RENCONTREZ DES PROBLÈMES AVEC CE PRODUIT,
CONTACTEZ LE MAGASIN DANS LEQUEL VOUS LAVEZ
ACHETÉ POUR UNE ASSISTANCE TECHNIQUE. N’UTILISEZ PAS
LE PRODUIT TANT QU’IL N’A PAS ÉTÉ RÉPARÉ.
L’UTILISATION DE COMMANDES, DE RÉGLAGES OU LE SUIVI
DE PROCÉDURES AUTRES QUE CE QUI EST DÉCRIT DANS
CE DOCUMENT PEUT PROVOQUER UNE EXPOSITION À UN
RAYONNEMENT DANGEREUX.
La plaque signalétique se trouve sous l’unité comme indiqué
ci-dessous.
Face avant
Plaque signalétique
MONTAGE EN RACK DE L’UNITÉ
Utilisez le kit de montage en rack pour monter l’unité dans un
rack 19” standard, comme représenté ci-dessous.
Retirez les pieds de l’unité avant le montage.
ATTENTION
i Laissez 1U d’espace au-dessus de l’unité pour la ventilation.
i Laissez au moins 10 cm à l’arrière de l’unité pour la
ventilation.
Pour les consommateurs européens
Mise au rebut des équipements électriques et
électroniques et des piles et/ou accumulateurs
(a) Tous les équipements électriques et électroniques et
piles/accumulateurs hors d’usage doivent être traités
séparément de la collecte municipale d’ordures ménagères
dans des points de collecte désignés par le gouvernement
ou les autorités locales.
(b) En vous débarrassant correctement des équipements
électriques/électroniques et piles/accumulateurs hors
d’usage, vous contribuerez à la sauvegarde de précieuses
ressources et à la prévention de potentiels eets négatifs
sur la santé humaine et l’environnement.
(c) Le traitement incorrect des équipements électriques/
électroniques et piles/accumulateurs hors d’usage
peut avoir des eets graves sur l’environnement et la
santé humaine en raison de la présence de substances
dangereuses dans les équipements.
(d) Le symbole de déchets d’équipements électriques
et électroniques (DEEE), qui représente une
poubelle à roulettes barrée d’une croix, indique
que les équipements électriques/électroniques
et piles/accumulateurs doivent être collectés et
traités séparément des déchets ménagers.
Si une pile ou un accumulateur contient plus
que les valeurs de plomb (Pb), mercure (Hg) et/
ou cadmium (Cd) telles que spéciées dans la
directive sur les piles et accumulateurs (2006/66/
EC, 2013/56/EU), alors les symboles chimiques
de ces éléments seront indiqués sous le symbole
DEEE.
Pb, Hg, Cd
(e) Des systèmes de retour et de collecte sont disponibles pour
l’utilisateur nal. Pour des informations plus détaillées
sur la mise au rebut des vieux équipements électriques/
électroniques et piles/accumulateurs hors d’usage, veuillez
contacter votre mairie, le service d’ordures ménagères ou
le magasin dans lequel vous avez acquis l’équipement.
FRANÇAIS
TASCAM SB-16D 19
Introduction
Merci beaucoup d’avoir choisi le boîtier de scène Dante à 16
entrées/16 sorties SB-16D de TASCAM.
Avant d’utiliser cette unité, lisez attentivement ce mode
d’emploi pour lemployer correctement et en proter durant de
nombreuses années. Une fois la lecture de ce mode d’emploi
terminée, veillez à le conserver en lieu sûr pour référence
ultérieure.
Vous pouvez aussi télécharger ce mode d’emploi depuis le site
web de TASCAM.
SB-16D
https://tascam.jp/int/product/sb-16d/docs
Caractéristiques
o Prend en charge 16 canaux dentrée ligne/micro analogique
o Prend en charge 16 canaux de sortie ligne/micro analogique
o Contrôlable à distance à l’aide de l’application dédiée
TASCAM IO CONTROL
i Commande de gain
i Activation/désactivation de l’alimentation fantôme
i Activation/désactivation de l’atténuateur (PAD)
i Autres fonctions
o Fonctionnalité Dante incluse en standard avec prise en
charge de la redondance
o LAES67 est également pris en charge, de sorte que la
connexion est possible avec les technologies audio réseau
Ravenna et compatibles
o Un routage exible est possible au moyen de Dante
Controller
o Prise en charge des fréquences et résolutions
d’échantillonnage jusqu’à 96kHz et 32bit
o Les entrées sont dotées de voyants d’alimentation fantôme,
de signal et de surcharge
o Les sorties ont des voyants de signal
o Prend en charge la redondance d’alimentation avec des
alimentations secteur (CA) et en courant continu (CC)
o Le niveau de référence peut être choisi
o Montage en rack 3U
Sommaire
INSTRUCTIONS DE SÉCURITÉ IMPORTANTES ......................18
Introduction ........................................................................... 20
Caractéristiques .....................................................................20
Éléments fournis avec ce produit ......................................... 21
Conventions employées dans ce mode d’emploi ................ 21
Précautions concernant l’emplacement et l’emploi ............ 21
Notes sur les alimentations ..................................................21
Attention à la condensation .................................................21
Nettoyage de l’unité ..............................................................21
À propos du service d’assistance clientèle TASCAM ........... 21
Nomenclature et fonctions des parties ...............................22
Face avant .............................................................................................. 22
Face arrière ............................................................................................ 23
Face latérale gauche ........................................................................... 23
Fixation des équerres de montage en rack .........................24
Connexion de l’alimentation ................................................25
Démarrage sur alimentation en courant
continu uniquement .......................................................................... 25
Remarques sur le voyant DC POWER ........................................... 25
Présentation de l’application ...............................................25
Présentation des réglages ....................................................25
Réglage des entrées micro/ligne ................................................... 25
Réglage de l’alimentation fantôme .............................................. 25
Réglage du niveau de référence .................................................... 25
Réglages d’identication d’appareil ....................................26
Vérication de l’identiant d’appareil (ID) .................................. 26
Changement de l’identiant d’appareil (ID) .............................. 26
Restauration des réglages d’usine ....................................... 27
Emploi comme extension de Sonicview ..............................27
Remarques à propos de Dante .............................................28
Connexion à un réseau Dante ...............................................28
Connexion commutée (en chaîne) ............................................... 28
Connexion redondante ..................................................................... 28
Emploi de Dante Controller ..................................................29
Présentation de Dante Controller.................................................. 29
Réglages de routage audio .............................................................. 29
Changement de la fréquence et de la résolution
d’échantillonnage avec Dante Controller ................................... 29
Paramètres de contrôle .........................................................30
Liste des paramètres .......................................................................... 30
Présentation du connecteur GPIO ................................................ 31
Caractéristiques techniques et valeurs nominales .............31
Performances audio ........................................................................... 31
Entrées et sorties ................................................................................. 31
Autres ...................................................................................................... 32
Dessins avec cotes ................................................................. 98
Software Licensing ................................................................ 99
20 TASCAM SB-16D
/