5
INTERNAL VIEW
3 4
6 7
1 DRIVER, WOOFER
2 DRIVER, TWEETER
3 INPUT (3) P.C.B.
4 INPUT (4) P.C.B.
5 AMP P.C.B.
6 INPUT (2) P.C.B.
7 DSP P.C.B.
8
SWITCHING POWER SUPPLY UNIT
9 INPUT (5) P.C.B.
4 INPUT (1) P.C.B.
FRONT VIEW
REAR VIEW
REAR UNIT
2
2 11
5
8 9 0
5
• DIMENSIONS
118 (4-11/16")
194 (7-5/8")
1030 (40-9/16")
Unit : mm(inch)
Manufactured under license from Dolby Laboratories.
“Dolby”, “Pro Logic”, and the double-D symbol are trademarks of
Dolby Laboratories.
“DTS”, and “Neo:6” are trademarks of Digital Theater Systems, Inc.
Manufactured under license from 1 Ltd. world-wide patents applied
for.
The “ logo and “Digital Sound Projector” are trademarks of 1
Ltd.
YSP-1
7
YSP-1
1
1
1
1
2
Top Panel
Top Panel
Plate/ Top
Fig. 1
1. Removal of Top Panels and Plate/Top
a. Remove 8 screws (1). (Fig. 1)
b. Remove 2 Top Panels.
c. Remove 2 screws (2). (Fig. 1)
d. Remove the Plate/Top.
DISASSEMBLY PROCEDURES /
(Remove parts in the order as numbered.)
Cautions for disassembly and reassembly :
Disconnect the power cable from the AC outlet.
Spread soft cloth or the like and perform the work on it.
Use full care as you may be injured by the front grille
or other part.
All screws must be tightened securely to prevent air
leakage. Check the number of screws and their
positions when installing them.
When installing parts, be careful not to have anything
such as cables caught between other parts.
Make sure that all the removed driver (tweeter) parts
are reinstalled at specified positions.
YSP-1
8
YSP-1
When checking the P.C.B. :
The Rear Unit removed from the unit does not work
because its grounding is loose. Be sure to connect the
ground of the Rear Unit to the chassis or GND with a
lead wire or the like. (Fig. A)
Reconnect all cables (connectors) that have been
disconnected.
Be sure to use the extension cable for servicing for the
following section.
DSP P.C.B. CB300 – INPUT (2) P.C.B. CB9 :
MFA27160 (27P 160mm)
DSP P.C.B. CB1, CB2 – AMP P.C.B. CB3 :
MFA18160 (18P 160mm)
When connecting the cable, use care for the polarity.
2. Removal of Rear Unit
a. Remove 22 screws (3). (Fig. 2)
b. Remove CB7, CB10 and CB14. (Fig. 3)
c. Remove the Rear Unit.
3 333
333
3
CB14 CB7 CB10
Rear Unit
Fig. A
Fig. 2
Fig. 3
Rear Unit
Front Panel Unit
DSP P.C.B.
INPUT (CONNECT) P.C.B.
AMP P.C.B.
CB3 CB1
CB300
CB2
CB9
CB3
MFA18160 MFA18160
MFA27160
AMP P.C.B.
Earth (lead wire)
YSP-1
9
YSP-1
3. Removal of INPUT (2) P.C.B.
a. Remove 14 screws (4). (Fig. 4)
b. Remove 3 pad Ls. (Fig. 4)
c. Remove the Plate/Shield.
d. Remove 4 screws (5). (Fig. 5)
e. Remove CB7, CB9 and CB302. (Fig. 5)
f. Remove the INPUT (2) P.C.B..
4 44
44
4
Plate/ Shield
Pad L
Fig. 4
4. Removal of DSP P.C.B., AMP P.C.B.
a. Remove 4 screws (6). (Fig. 6)
b. Remove CB3 and CB303. (Fig. 6)
c. Remove DSP P.C.B..
d. Remove 8 screws (7). (Fig. 6)
e. Remove CB1, CB2, CB4, CB5 and CB6. (Fig. 6)
f. Remove AMP P.C.B.s.
5
5
INPUT (2) P.C.B.
CB7
CB9
CB302
CB7
Fig. 5
Fig. 6
6
6
CB1
CB303
CB6 CB1
CB2 CB5 CB4
7
7
7
7
CB6 CB3 CB4CB3 CB2CB5
DSP P.C.B.
AMP P.C.B.
AMP P.C.B.
YSP-1
10
YSP-1
5. Removal of Front Panel Unit
a. Remove 17 screws (8). (Fig. 7)
b. Remove the Front Panel Unit.
c. Remove 2 screws (9). (Fig. 8)
d. Remove the Stopper frame.
8 88 88
Front Panel Unit
9
Stopper Frame
Fig. 8
0 0 0
0 0 0 0
0
TOP
BOTTOM
Fig. 9
6. Removal of Driver (Tweeter)
a. Remove 12 screws (0). (Fig. 9)
b. Remove 4 Supports/DSP.
c. Remove the Sound absorbing material.
d. Remove 2 screws/piece marked (A). (Fig. 11)
e. Remove the Driver (Tweeter).
Sound Absorber
Support/ DSP Support/ DSP
Fig. 10
Fig. 7
YSP-1
11
YSP-1
Installation of Driver (Tweeter)
Caution : Make sure that all the removed Driver (tweeter)
parts are reinstalled at specified positions.
(Fig. B)
A1
B1
A2
B2
C1
A3
B3
C2
A4
B4
C3
A5
B5
C4
A6
B6
C5
A7
B7
C6
A8
B8
C7
A9
B9
C8
A10
B10
C9
A11
B11
C10
A12
B12
C11
A13
B13
A14
B14
A15
REAR VIEW
Rch side Lch side
CB1
CB2 CB5 CB6 CB1
CB6 CB5 CB2
A
Fig. 11
Fig. B
Lch side /
Pin No. / CB1
1 2
3 4
5 6
7 8
9 #
A1
B1
A2
A3
A4
C5
B6
C4
B5
C3
A5
A6
A7
B7
A8
B13
C11
B12
C10
B11
A12
A13
A14
B14
A15
A9
B9
A10
B10
A11
C9
C8
C7
B8
C6
B4
C2
B3
C1
B2
CB2 CB5 CB6 CB1 CB2 CB5 CB6
Rch side /
#: CB1, CB2_10pin CB5, CB6_11pin
YSP-1
12
YSP-1
D
D
E
E
B
B
C
C
C
C
Side Cover L
Side Cover R
Plate Side
Plate Side
Plate Cover
Plate Cover
Front Grille
Driver, Woofer
Driver, Woofer
7. Removal of Driver (Woofer)
a. Remove 4 screws (B). (Fig. 12)
b. Remove the Side covers L/R.
c. Remove the Plate/Cover.
d. Remove 4 screws (C). (Fig. 12)
e. Remove the Plate/Side.
f. Remove 18 screws (D). (Fig. 12)
g. Remove the Front grille.
h. Remove 8 screws (E). (Fig. 12)
i. Remove the Driver (Woofer).
Fig. 12
YSP-1
13
YSP-1
RS232C cross cable “D-sub 9 pin female”
(Specifications)
Pin No.2 RxD Pin No.2 RxD
Pin No.3 TxD Pin No.3 TxD
Pin No.5 GND Pin No.5 GND
Pin No.7 RTS Pin No.7 RTS
Pin No.8 CTS Pin No.8 CTS
Preparation and precautions before starting
the operation
Download FlashSta.exe and
spDownloader_2_0_7_xxx.exe from the specified
source to the PC being used.
Prepare the above specified RS232C cross cable.
While writing, keep the other application software on
the PC closed. It is also recommended to keep the
software on the task tray closed as well.
UPDATING FIRMWARE /
CPU .............................................. YSP1verxxx.mot
................................................. YSP1verxxx.id
DSP DSP APPLICATION ..... SPCM_D2-0_xxx.hex
SPID ............................................ MPxxxxx.bin
CSC .............................. SPCM_CSC_xxx.hex
After replacing the following parts with the replacement
parts, update the firmware.
P.C.B. ASS’Y DSP : WE218400
IC304 of P.C.B. ASS’Y DSP : X3601A00
IC2 of P.C.B. ASS’Y DSP : X6210B00
Required tools
DOS/V machine, OS: Windows 98/2000/Me/XP, PC
with a serial port (RS232C)
Program upgrading program
There are 2 program upgrading programs.
for CPU : FlashSta.exe
for DSP : spDownloader_2_0_7_xxx.exe.
Firmware
* Be sure to put following 5 firmwares in the same
folder.
YSP-1
14
YSP-1
Operation Procedure
For CPU
1. Install FlashSta.exe into the PC.
2. Before turning on the power to YSP-1 and PC, connect
between RS232C ports with the RS232C cable (cross
cable). (Fig. 1)
3. While pressing the reset switch of YSP-1, connect the
power cable to the AC outlet. (Fig. 1)
* Use a fine tipped pin or the like to push the reset
switch.
4. Start up FlashSta.exe, the screen will appear as shown
below.
5. Select the data to be transmitted and port.
· Select Program
Select Internal flash memory
· RS232C
Select the port of RS-232C
Select the port of RS-232C
Select Internal flash memory
* For selection of the port, COM1 to 4 can be used.
As COM5 or higher port cannot be used, select
out of COM 1 to 4 of the setting on the PC side.
BOTTOM VIEW
RS-232C Port
Reset Switch
Fig. 1
YSP-1
15
YSP-1
6. Press the [Refer...] button. And select the firmware
name.
* The ID code is loaded when the file is selected.
7. Press the [Setting] button and set the transmission rate.
8. Press the [E.P.R.] button and start writing.
Press this button to open the window
Select M16/20 62
Press this button to open the window
Select 57600bps or below for the transmission rate.
Also, reduce the transmission rate if a transmission
error occurs frequently.
Press this button to start writing
YSP-1
16
YSP-1
For DSP
1. Install spDownloader_2_0_7_xxx.exe into the PC.
2. Before turning on the power to YSP-1 and PC, connect
between RS232C ports with the RS232C cable (cross
cable). (Fig. 1)
3. Connect the power cable of YSP-1 to the AC outlet.
While pressing the “VOL+” key and “VOL-” key of the
YSP-1, press the “STANDBY/ON” key of the remote
controller to activate the DIAG function.
1 Using the “UP” or “DOWN” key of the remote
controller, select the DIAG menu in the figure below.
2 Using the “LEFT” or “RIGHT” key of the remote
controller, select the DIAG sub-menu in the figure
below.
3 Using the “SELECT” key of the remote controller,
make a change as shown below.
4 For restarting, use the “STANDBY/ON” key of the
YSP-1 or the remote controller.
9. When the program transmission is completed, the
screen appears as shown below.
The press the [OK] button to end the procedure.
Change OFF to ON
YSP-1
17
YSP-1
Select the port of RS-232C
Select SPCM Protocol
5. Select the data to be transmitted and port.
· COM Port
Select the port of RS-232C.
· D/load Protocol
Select “SPCM Protocol”
Press this button to open the window
1 Press the button beside the Source firmware Box.
And select the firmware.
1
4. Start up spDownloader_2_0_7_xxx.exe, the screen will
appear as shown below.
6. Select Firmware and execute writing as follows.
First, select DSP APPLICATION and perform steps 1
to 4 for writing.
Then, select SPID and perform steps 1 to 4 for writing.
Finally, select CSC and perform steps 1 to 4 for writing.
1 4
1 4
1 4
YSP-1
18
YSP-1
Confirm OK
3 After downloading sccessfully, Download ***** OK
is appeared.
Confirm DLOAD OK on the Serial Log window.
3
Firm Software Target
DSP application SPCM Application
SPID SPCM init Data
CSC SPCM CSC
2 Confirm Software Target and press the [Download]
button.
2
Start Download During downloading
* When Source filename is selected, Software
Target box is selected automatically.
* If Software Target is different, confirm again
Source filename or re-open spDownloader.
4 Press the [Done] button.
The display returns to screen (1).
4
1
YSP-1
19
YSP-1
1 Using the UP or DOWN key of the remote
controller, select the DIAG menu in the figure below.
4 Check the version of the firmware.
The procedure has been completed when "DSP
VER./MID" appears as the DIAG menu and the
same version as shown below is obtained.
3 Using the SELECT key of the remote controller,
make a change as shown below.
2 Using the LEFT or RIGHT key of the remote
controller, select the DIAG sub-menu in the figure
below.
SPID version
Change ON to OFF.
7. Press the STANDBY/ON key of the YSP-1 to turn off
the power.
8. While pressing the VOL+ key and VOL- key of the
YSP-1, press the STANDBY/ON key of the remote
controller to activate the DIAG function.
9. Press the STANDBY/ON key of the YSP-1 to turn off
the power.
YSP-1
21
YSP-1
• Starting DIAG
To activate the DIAG function, press the “STANDBY/ON”
key of the remote controller while pressing the keys of the
main unit as shown below at the same time.
Starting DIAG in the protection cancel mode
If the protection function works and causes hindrance to
trouble diagnosis, cancel the protection function as
described below, and it will be possible to enter the DIAG
mode.
Press the “STANDBY/ON” key while simultaneously
pressing those two keys indicated in the figure above. At
this time, keep pressing those two keys for 3 seconds or
longer.
In this mode, the “SLEEP” segment of the FL display of the
main unit flashes to indicate that the mode is DIAG mode
with the protection functions disabled.
CAUTION!
Using this product with the protection function disabled
may cause damage to itself. Use special care for this
point when using this mode.
• Canceling DIAG
[1] Before canceling DIAG, execute setting for PRESET of
DIAG menu No.6 (Memory initialization inhibited or
Memory initialized).
* In order to keep the user memory stored, be sure to
select PRESET INHIBIT (Memory initialization
inhibited). Any protection history will remain in
memory.
[2] Turn off the power by pressing the “STANDBY/ON”
key of the main unit or the “STANDBY” key of the
remote controller.
Keys of main unit
Turn on the power while pressing these keys.
YSP-1
22
YSP-1
Cause: The voltage in the power supply section is
abnormal.
Supplementary information: The abnormal voltage is
displayed in % based on 3.3V as 100%.
Turning on the power without correcting the abnormality
will cause the protection function to work 1 second later
and the power supply will be shut off.
When there is a history of protection
function due to abnormal voltage in
the power supply section
Version (1 alphabet)
Voltage display in %
When there is a history of protection function:
• Display provided when DIAG started
When the monitor is connected, DIAGNOSTIC MENU
appears on its screen as shown in the figure. (It remains
on display until DIAG is cancelled.)
The FL display of the main unit displays the protection
function history data and the version (1 alphabet) and the
DIAG menu [sub-menu (THR ALL) of DIAG menu No.1
DSP THROUGH] a few seconds later.
Opening message DIAG menu display
After a few seconds
Version (1 alphabet)
When there is no history
of protection function
When there is no history of protection function:
YSP-1
23
YSP-1
Display during menu operation
During the DIAG operation, the menu list described in the
section of the startup screen appears on the
superimposed screen and the function at work is indicated
on the FL indicator. The contents displayed during the
function operation are described in the later section on
details of functions.
Operation procedure of DIAG menu and
SUB-MENU
There are 14 MENU items, each of which has some SUB-
MENU items.
DIAG menu selection
Select the DIAG menu by using the UP/DOWN
(Reverse) (Forward) key of the remote controller.
SUB-MENU selection
Select the DIAG sub-menu by using the LEFT/RIGHT
(Reverse) (Forward) keys.
History of protection function
When the protection function has worked, its history is
stored in memory with a backup. Even if no abnormality
is noted while servicing the unit, an abnormality which
has occurred previously can be defined as long as the
backup data has been stored.
The history of the protection function is cleared when
DIAG is cancelled by selecting PRESET RESERVED
(Memory initialized) of DIAG menu No. 6 or when the
backup data is erased.
*To clear the protection history only, use the SUB menu
No.3 "PROTECT His (PrHist <- RESET) of DIAG menu
No.12".
SUB-MENU selection
DIAG menu selection
YSP-1
24
YSP-1
Functions in DIAG mode
In addition to the DIAG menu items, functions as listed
below are available.
Input selection
Muting
Night
Power on/off
Master volume
* Functions related to the set menu are not available.
Initial settings used to start DIAG
The following initial settings are used when starting DIAG.
When DIAG is canceled, these settings are restored to
those before starting DIAG.
Master volume: -40dB
Input: TV
Effect level: 0dB
Audio mute: OFF
DIAG menu: DSP THR ALL
YSP-1
25
YSP-1
DSP THR FRONT L
FRONT L output without the head margin is provided in
digital full bit.
The SWFR signal is output but not in digital full bit.
• Details of DIAG menu
With full-bit output specified in some modes, it is possible
to execute 0dBFS output without head margin in each
channel.
1. DSP THROUGH
This function is for YSS930 only. Main DSP of YSS930
is selected for FRONT output.
DSP THR ALL
All outputs (FRONT L/R, CENTER, SURROUND L/R,
LFE) including the head margin are provided.
Analog
YSS948-YSS930
(ANALOG)
(Shaded items not used in this example)
Note : The analog signal level can not be confirmed
because of the digital signal processing.
YSP-1
26
YSP-1
DSP THR SURROUND R
SURROUND R output without the head margin is
provided in digital full bit.
The SWFR signal is output but not in digital full bit.
DSP THR SURROUND L
SURROUND L output without the head margin is
provided in digital full bit.
The SWFR signal is output but not in digital full bit.
DSP THR LFE
LFE output without the head margin is provided in
digital full bit.
The SWFR signal is output but not in digital full bit.
DSP THR FRONT R
FRONT R output without the head margin is provided in
digital full bit.
The SWFR signal is output but not in digital full bit.
DSP THR CENTER
CENTER output without the head margin is provided in
digital full bit.
The SWFR signal is output but not in digital full bit.
/