Niigata seiki GDG-P-S2 ユーザーマニュアル

タイプ
ユーザーマニュアル

このマニュアルも適しています

Read the manual and follow the directions.
Use of product other than as described in this manual
may cause accident.
Use only for measuring.
Use for any purpose other than measuring may
damage or wear the instrument. Improper use may
also cause accident.
Handle with Care.
Do not drop or subject instrument to excessive shock.
Do not place under heavy objects. Improper handling
may cause damage or poor accuracy.
Do not scratch or mark the body of the gauge.
Avoid using in high electric fields, such as near
fluorescent lights or switching power supplies.
Incorrect value may be displayed on LCD.
Probe Tip is Sharp-Handle With Care.
Tip can cause injury.
Remove any dirt or rustproofing from the measuring
surfaces and moving parts before use. Make sure the
hardware is tight and secure.
Improper preparation may cause measurement errors.
Use and store only in environment meeting the
following conditions:
Dry location protected from rain, water, and oils.
Location that is not excessively hot.
Location protected from use by children and
unauthorized people.
Use in places contrary to the above may cause damage
to the product resulting in accident or injury.
Do not disassemble or modify.
Disassembly may damage product or cause accident.
For repair, please contact distributor or place of purchase.
Do not write on instrument with electric engraver.
Do not engrave instrument body or jaw arm, such as an
ID number with engraver or electric pen.
Indicates risk of personal injury or property damage if not followed.
WARNING
To prevent harm to yourself or others, and to prevent damage to
property, always follow the procedures marked by the following
symbols.
Denotes a prohibition –
You MUST NOT do.
Denotes a requirement –
You MUST do.
SAFETY PRECAUTIONS Please Observe
Main Beam Supports LCD Display Unit.
Lock Screw Tighten to Prevent the Slide and Display from
moving.
Arm Lock Screw Fixes the joint between the Arm and Jaw.
(GDG-4F-J1 only)
Clamp Screw Secure the sliding Probe Holder in place.
Probe Holder Holds the Probe.
Jaw Supports the sliding Probe Holder.
Standard straight arm, jointed version for
(GDG-4F-J1 only).
Lock Nut Tighten to secure the Probe in place.
Probe Tip is applied to workpiece for measurement.
Tip available in stainless steel, or plastic
(GDG-P-S2 only).
Reference Surface Measurement is difference between Tip position,
and this surface.
4-point (flat bottom) (GDG-4F-S1 GDG-4F-J1)
3-point
(round) (GDG-3R-S1)
2-point
(round) (GDG-2R-S1)
Flat
(GDG-F-S1)
Plastic version available (GDG-P-S2)
LCD Display Displays digital measurement.
Battery Cover Open to access battery.
[ZERO] Button When pressed, Display will read "0.00"
[ON/OFF] Button For turning power ON / OFF.
[HOLD] Button When pressed, "HOLD"Icon appears on Display
and measurement will be fixed.
Output Connector Measurement value can be outputted to the PC
by connecting BluetoothBOX of the option.
PART IDENTIFICATION AND FUNCTION
Model GDG-4F-J1 shown
DIGITAL GAP CALIPER
PRECISION MEASURING TOOLS Model No.
INSTRUCTION MANUAL
Thank you for purchasing the Niigata Seiki Digital Gap Caliper.
This is a precision measuring tool for step height measurements.
For safe and proper use, please read this instruction manual before use and follow the procedures described. Please keep manual
where it is accessible to user for future reference.
Keep this manual with the instrument if transferred or leased to a third party.
For inquiries about this product, please contact dealer or Niigata Seiki.
GDG
- -
Resolution 0.01mm
Instrument Error 0.03mm
Not including quantization error
(1count)
Measurement Range 13 to 16mm
Display 4 Digit LCD
Auto Off approx. 20 min.
Maximum response speed Upward... 1.5m/s
Downward ... 0.75 m/s
Direction as shown in diagram at top
of manual.
Operating Temperature Range
0 C40 C
Storage Temperature Rang 10 C 60 C
Power (1x ) CR 2032 Lithium Battery
Battery Life approx. 2.5 years in normal
use
Accessory CR 2032 Lithium Battery
(for test)
SPECIFICATIONS
After use, wipe off any dirt or oil from measuring surfaces, sliding
surfaces, and exterior using a dry cloth and perform rust
prevention treatment.
For rust prevention, lightly apply anti-rust oil, or place in rust
preventive bag.
Store with Lock Screw slightly loose
If Lock Screw is tightened, expansion due to temperature changes
may cause excessive force which will cause inaccuracy.
Store in a cool, dry, and dark location in the provided case
Keep out of direct sunlight and moisture, and please keep secure
from unauthorized personnel.
Remove battery if Gauge will not be used for a long period of time.
AFTER USE CARESTORAGE
[ON/OFF] Button turns power ON / OFF.
[ZERO] Button sets the display to read "0.00" when pressed.
[HOLD] Button will fix the display value when pressed.
Absolute Measurement Mode
Turn on the Gauge, and loosen the Lock
Screw.
Position the probe tip for the desired
measurement, and tighten the Clamp
Screw, and the Arm Lock Screw
(Model GDG-4F-J1). (Figure 1.)
Place the gauge on a flat reference surface,
and slide the tip down for good contact.
Press the [Zero] Button.
(Figure 2.)
Gauge is ready for measurement when
the display reads "0.00 mm"
Slide the gauge head up and down to
make contact with the surface you want
to measure. (Figure 3.)
Do not change the position of the
Probe Holder as set in step , or the
measurement will not be correct.
Comparisons Measure Mode
Turn on the Gauge, and loosen the Lock
Screw.
Position the Gauge to measure the
Reference surface, and press the [Zero]
Button.
Next, position the Gauge to measure the
surface for comparison, and the difference
in height with the reference will be
displayed.
Measurement Precaution
To prevent error, make sure the Base is not
tilted when making measurements.
(Figure 4.)
HOW TO USE
If Instrument is not working properly, or if you have any
questions, please contact distributor or place of
purchase.
Please note, manufacturer is unable to respond to
inquires or provide service directly. Please contact
distributor or place of purchase.
SERVICE
Q. Nothing is displayed on LCD
A. The battery may be running low, please replace
battery with a new one.
Q. With power on, the number on the LCD does not
change as Display Unit is moved.
A. Please reset by removing battery for about
30sec., and then replacing.
Q. Nothing happens when buttons are pressed.
A. Make sure battery is properly inserted.
Q. The characters MIN , MAX , or are
displayed on LCD.
A. Cycle power, or apply several long presses to
[HOLD] Button. Use as normal once character is
off.
Q. The correct value is not displayed.
A. High humidity may cause dampness. Please dry
off the instrument and use only in dry location.
TROUBLESHOOTING
Slide cover in direction of arrow.
Insert battery with ( ) side
outward.
Replace battery cover.
Use care to avoid damaging terminals when inserting
battery.
Terminals may be broken if battery is pressed straight
down.
Insert battery at angle, underneath the small hook, as
shown.
Use only CR2032 type
battery.
Notice
INSERTING REPLACING BATTERY
DIGITAL GAP CALIPER
Reference Surface
Jaw
Lock Nut
Probe
Clamp Screw
Arm Lock Screw
(GDG-4F-J1 only)
Probe Holder
Main Beam
Lock Screw
Output Connector
Battery Cover
[ON/OFF] Button
[ZERO] Button
[HOLD] Button
LCD Display
1/8" Nylon Ball Tip
(GDG-P-S2 only)
1/8" Nylon Ball Tip
(GDG-P-S2 only)
Stainless Tip SR0.5mm
GDG-4F-S1
4-Point
(Flat)
Stainless Tip
SR 0.5mm
GDG-3R-S1
3-Point
(Round)
GDG-F-S1
Flat
1/8" Nylon
Ball Tip
Model
Base
Arm
Probe
Weight(g)
Stainless TipSR 0.5mm
Straight Jointed
145 150 145 150155
GDG-2R-S1
2-Point
(Round)
150
GDG-P-S2
Plastic
GDG-4F-J1
4-Point
(Flat)
DIGITAL GAP CALIPER
Figure 4.Figure 4.
DIGITAL GAP CALIPER
Contact
DIGITAL GAP CALIPER
Flat Surface
ZERO
Contact
DIGITAL GAP CALIPER
Lock Screw
Clamp Screw
Probe Holder
Battery
Hook
Slide In
Pressed
Terminals
Battery Cover
Remove
Secure
Figure 3.Figure 3.
Figure 2.
Figure 2.
Figure 1.
Figure 1.
Reference
Surface
Niigata seiki Co., Ltd.
5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055
Tel. : +81-256-33-5522 Fax. : +81-256-33-5518
URL http://www.niigataseiki.co.jp
DIGITAL GAP CALIPER
DIGITAL GAP CALIPER
DIGITAL GAP CALIPER
DIGITAL GAP CALIPER
DIGITAL GAP CALIPER
URL http://www.niigataseiki.co.jp
  • Page 1 1
  • Page 2 2

Niigata seiki GDG-P-S2 ユーザーマニュアル

タイプ
ユーザーマニュアル
このマニュアルも適しています

他の言語で