PART IDENTIFICATION AND FUNCTION
Object to be measured is positioned between these surfaces.
For measuring outside dimensions.
Secures the adjustable jaw in position.
For measuring inside dimensions.
Position surfaces inside object to be measured.
Displays digital measurement.
Tighten to prevent the slide and display from moving.
When pressed, "HOLD"Icon appears on Display and measurement will be fixed.
Connect to optional Bluetooth Box to send measurements to PC.
Supports LCD Display Unit.
Open to access battery.
When pressed, Display will read "0.00".
For turning power ON / OFF.
Measuring Surfaces for outside measurements ....
Outside Jaws .........................................................
Jaw Clamp Screw ..................................................
Inside Jaws ............................................................
Measuring surfaces for inside measurements .......
LCD Display...........................................................
Lock Screw ............................................................
[HOLD] Button .......................................................
Output Connector ..................................................
Scale .....................................................................
Battery Cover ........................................................
[ZERO] Button .......................................................
[ON/OFF] Button ...................................................
Thank you for purchasing Niigata Seiki Digital Offset Calipers.
This is a precision measuring tool for measuring inside and outside dimensions when there is a step or offset between surfaces.
Jaw can be adjusted to match workpiece for accurate measurements.
Measuring surfaces for
outside measurements
Outside Jaws
Jaw Clamp Screw
Output Connector
Battery Cover
[HOLD] Button
Lock Screw
LCD Display
[ON/OFF] Button
[ZERO] Button
Power ON/OFF
To turn on, press the [ON/OFF] Button.
To turn off, press the [ON/OFF] Button.
With power on, press the [HOLD] Button to fix the value on the
display.
Absolute Measurement Mode
Loosen the Lock Screw and turn power ON.
With jaws closed, press the [ZERO] Button.
When 0.00mm is displayed on LCD, Caliper is ready to start
measurement.
Comparison Measure Mode
Loosen the Lock Screw and turn power ON.
With jaws open to desired reference position (any point is OK,)
press [ZERO] Button.
When 0.00mm is displayed on LCD, Caliper is ready to start
measurement.
Adjusting the Jaw Position
Loosen the Jaw Clamp Screw and adjust the Jaw for the desired
position and re-tighten to use.
TROUBLESHOOTING
AFTER USE CARE STORAGE
After use, wipe off any dirt or oil from measuring
surfaces, sliding surfaces, and exterior using a dry
cloth and perform rust prevention treatment.
For rust prevention, lightly apply anti-rust oil, or place in rust
preventive bag.
Store with Lock Screws loosened.
If stored with Lock Screws tight, expansion due to temperature
changes may cause excessive force which will cause inaccuracy.
Store in a cool, dry, and dark location in the provided
case.
Keep out of direct sunlight and moisture, and please keep
secure from unauthorized personnel.
Remove battery if Caliper will not be used for a long
period of time.
Q. Nothing is displayed on LCD.
A. The battery may be running low, please replace battery
with a new one.
Q. With power on, the number on the LCD does not change
as Display Unit is moved.
A. Please reset by removing battery for about 30sec., and
then replacing.
Q. Nothing happens when buttons are pressed.
A. Make sure battery is properly inserted.
Q.
The characters MIN , MAX , or are displayed on LCD.
A. Cycle power, or apply several long presses to [HOLD]
Button. Use as normal once character is off.
Q. The correct value is not displayed.
A. High humidity may cause dampness. Please dry off the
instrument and use only in dry location.
If Instrument is not working properly, or if you have any
questions, please contact distributor.
Please note, manufacturer is unable to respond to inquires or
provide service directly. Please contact distributor.
Scale
INSERTING REPLACING BATTERY
Slide cover in direction of arrow.
Insert battery with (+) side outward.
Replace battery cover.
Use care to avoid damaging
terminals when inserting
battery
Terminals may be broken if battery is pressed straight down.
Insert battery at angle, underneath the small hook, as shown.
Use only CR2032 type
battery
Notice
Battery
Cover
Remove
Hook
Slide In
Terminals
Terminals
Measuring surfaces for
inside measurements
Inside Jaws
Measurement Range : 0
-
150mm
Maximum Permissible Error : 0.04mm
Not including quantization error (1count)
Resolution : 0.01mm
Display : 5 Digit LCD
Auto Off : approx. 20 min.
Maximum response speed : Slide to Right 1.5 m/s
Slide to Left 0.75 m/s
Left/Right as shown in diagram at top of manual.
Operating Temperature Range : 0 C 40 C
Storage Temperature Range : 10 C 60 C
Power : (1x) CR2032 Lithium Battery
Battery Life : approx. 2.5 years in normal use.
Weight : 230g
Accessory : CR2032 Lithium Battery (for test)
SPECIFICATIONS
SERVICE
Before using the caliper, please follow the steps below:
Wipe off rust proofing and dirt from measuring
surfaces and slide.
Contamination of surfaces may cause measurement error.
Allow the caliper and object to be measured time to
reach the same temperature.
A temperature difference between the object to be
measured and the caliper may cause measurement error.
Allow enough time for the temperatures to equilibrate.
DIGITAL OFFSET CALIPERS
PRECISION MEASURING TOOLS GDCS
-
150F
Model No.
User Manual
For safe and proper use, please read this instruction manual before use and follow the procedures described.
Please keep manual where it is accessible to user for future reference.
Keep this manual with the instrument if transferred or leased to a third party.
For inquiries about this product, please contact dealer or Niigata Seiki.
PREPARATION FOR USE
HOW TO USE
SAFETY PRECAUTIONS Please Observe
To prevent harm to yourself or others, and to prevent damage to
property, always follow the procedures marked by the following
symbols.
Read the manual and follow the directions.
Use of product other than as described in this manual
may cause accident.
Use only for measuring.
Use for any purpose other than measuring may
damage or wear the instrument. Improper use may
also cause accident.
Handle with Care.
Do not drop or subject instrument to excessive shock.
Do not place under heavy objects. Improper handling
may cause damage or poor accuracy.
Do not scratch instrument, for example by writing ID
number.
Avoid using in high electric fields, such as near
fluorescent lights or switching power supplies.
Incorrect value may be displayed on LCD.
Indicates risk of personal injury or property damage if not followed.
WARNING
Denotes a prohibition -
You MUST NOT do
Denotes a requirement -
You MUST do
Use and store only in environment meeting the
following conditions:
Dry location protected from rain, water, and oils.
Location that is not excessively hot.
Location protected from use by children and
unauthorized people.
Use in places contrary to the above may cause damage to
the product resulting in accident or injury.
Jaw Tips Are Sharp Handle With Care.
Careless handling may cause injury.
Do not disassemble or modify.
Disassembly may damage product or cause accident. For
repair, please contact distributor.
Do not write on instrument with electric engraver.
Do not engrave instrument body or jaw, such as an ID
number with engraver or electric pen.
Battery
Niigata Seiki Co., Ltd.
5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055
Tel. : +81-256-33-5522 Fax. : +81-256-33-5518
MAIL intl.sales@niigataseiki.co.jp
URL http://www.niigataseiki.co.jp
Pressed Down
Battery
URL http://www.niigataseiki.co.jp
  • Page 1 1
  • Page 2 2

Niigata seiki GDCS-150F ユーザーマニュアル

タイプ
ユーザーマニュアル

他の言語で

その他のドキュメント