Allen-Bradley 140MG Series ユーザーマニュアル

カテゴリー
同軸ケーブル
タイプ
ユーザーマニュアル

このマニュアルも適しています

Cu/CuAl Terminal lugs for 140G-M
Cu/CuAl Terminali anteriori per cavi
Cu/CuAl Vorderseitige Anschlüsse für Kabel
Cu/CuAl Prises de raccordement avant pour câbles
Cu/CuAl Terminales frontales para cables
Bul. 140G/140MG
DIR 1000479R0824 Version 04
WARNING: To prevent electrical shock, disconnect from power source before
installing or servicing. Install in suitable enclosure. Keep free from contaminants.
(Follow NFPA70E requirements).
AVVERTENZA: Per prevenire infortuni, togliere tensione prima dell'installazione o
manutenzione. Installare in custodia idonea. Tenere lontano da contaminanti.
WARNUNG: Vor Installations- oder Servicearbeiten Stromversorgung zur
Vermeidung von elektrischen Unfällen trennen. Die Geräte müssen in einem
passenden Gehäuse eingebaut und gegen Verschmutzung geschützt werden.
AVERTISSEMENT: Avant le montage et la mise en service, couper l'alimentation
secteur pour éviter toute décharge. Prévoir une mise en coffret ou armoire appropriée.
Protéger le produit contre les environnements agressifs.
ADVERTENCIA: Desconéctese de la corriente eléctrica, antes de la instalación o
del servicio, a fin de impedir sacudidas eléctricas. Instálelo en una caja apropiada.
Manténgalo libre de contaminantes.
ATENÇÃO: Para evitar choques, desconectar da corrente elétrica antes de fazer a
instalação ou a manutenção. Instalar em caixa apropriada. Manter livre de
contaminantes.
Installation - Installazione - Instalación
Instalação - -
DIR 1000479R0824 Version 04 - 140G-M-TLA23, 140G-M-TLA24, 140G-M-TLC23, 140G-M-TLC24, 140G-M-TLA33, 140G-M-TLA34, 140G-M-TLC33, 140G-M-TLC34,
3p
4p
CuAl
(2) 250...500 MCM
(2) 120...240 mm²
x3
x4
x3
x3
x4
x4
x6
x8
3p
4p
Cu
(2) 3/0...350 MCM
(2) 85...185 mm²
警告:感電事故防止のため、取付けまたは修理の際は電源から取り外してく
ださい。適切なケース内に取付けてください。また、汚染物質がないことを
確認してください。
警告:为了防止触电,在安装或维修之前必须先切断电源。安装在合适的设备
箱内。防止接触污染 。
140G-M-TLA23
140G-M-TLA24
140G-M-TLC23
140G-M-TLC24
x3
x4
x3 x3
x4 x4
x6
x8
Screw Screw
Lug Screw Screw
LENGTH M
20 mm (0.79") M 6
LENGTH M
35 mm (1.38") M 6
LENGTH M
20 mm (0.79") M 6
LENGTH M
35 mm (1.38") M 6
140G-M-TLA2A3, 140G-M-TLA2A4
Lug
Required tools
xx lb-in
xx Nm
xx lb-in
xx Nm
xx lb-in
xx Nm
LENGTH dia.
0.28" (7mm) 0.1 9
LENGTH dia.
0.28" (7mm) 0.1 9
x1
x1
x6
x8
x2
x2
x3
x4
3p
4p
CuAl
(3) 2/0...400 MCM
(3) 70...185 mm²
3p
4p
Cu
(3) 2/0...350 MCM
(3) 70...185 mm²
(2)
140G-M-TLA33
140G-M-TLA34
140G-M-TLC33
140G-M-TLC34
x1
x1
x2
x2
x3
x4
Lug Screw Screw
Terminal cover
CH 5
x6
x8
Lug Screw Screw
Terminal cover
LENGT H M
55 m m (2.1 7") M 6
LENGT H dia.
1 2 m m (0.47" ) 3.5
CH 5
LENGT H M
55 m m (2.1 7") M 6
LENGT H dia.
1 2 mm (0.47" ) 3.5
x1
x1
x6
x8
x2
x2
x3
x4
3p
4p
CuAl
(2) 500...750 MCM
140G-M-TLA2A3
140G-M-TLA2A4
Lug
Screw Screw
Terminal cover
(Ip20 protection)
CH 5
LENGT H M
55 m m (2.1 7") M 6
LENGT H dia.
1 2 m m (0.47" ) 3.5
LENGTH dia.
0.28" (7mm) 0.1 9
LENGTH dia.
0.28" (7mm) 0.1 9
LENGTH dia.
0.28" (7mm) 0.1 9
DIR 1000479R0824 Version 04
2
9 Nm
max 0.75"/19mm
43 Nm
381 lb-in
80 lb-in
min 1.22"/31 mm
CH 10
CH 5
LENGTH M
55 mm (2.17") M 6
Flexible Cable
AWG/kcmil
mm
2
-
MIN 2/0 AWG 70 -
MAX 400kcmil 185 -
MIN 2/0 AWG 70 -
MAX 350kcmil 185 -
CuAl
Cu
Stranded Cable
Example for 140G-M-TLA33
(3)
Flex ible C able
A W G /k c m il
m m
2
-
M IN 250 k c m il 120 -
M A X 500k c m il 240 -
M IN 3/0 A W G 85 -
M A X 350k c m il 185 -
CuA l
Cu
S tranded Cable
Example for 140G-M-TLA23
5 Nm
44.3 lb-in
LENGTH M
20 mm (0.79") M 6
LENGTH M
35 mm (1.38") M 6
max 0.84"/21.5mm
min 0.94"/24mm
31 Nm
274 lb-in
CH 8
1
5
4
6
7
8
1.5 Nm
13.3 lb-in
1.5 Nm
13.3 lb-in
1.1 Nm
9.7 lb-in
LENGTH dia.
1 2 mm (0.47") 3.5
DIR 1000479R0824 Version 04
DIR 1000479R0824 Version 04 (L6160) - B1645
Copyright © 2018 Rockwell Automation, Inc. All Rights Reserved. Printed in Italy.
Allen-Bradley, Rockwell Software, and Rockwell Automation are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Publication 140G-IN040E-MU-P - January 2018
Rockwell Automation maintains current product environmental compliance information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/
sustainability-ethics/product-environmental-compliance.page
3
9 Nm
max 1"/25.5mm
67 Nm
593 lb-in
80 lb-in
min 1.5"/38 mm
CH 10
CH 5
LENGT H M
55 m m (2.1 7" ) M 6
Flexible Cable
kcmil
mm
2
-
MIN 500 - -
MAX 750 - -
CuAl
Stranded Cable
max 1"/25.5mm
min 2.05"/52 mm
1.5 Nm
13.3 lb-in
Example for 140G-M-TLA2A3
1.1 Nm
9.7 lb-in
LENGTH dia.
1 2 mm (0.47") 3.5
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Allen-Bradley 140MG Series ユーザーマニュアル

カテゴリー
同軸ケーブル
タイプ
ユーザーマニュアル
このマニュアルも適しています