Raidon iR2623-S3 取扱説明書

タイプ
取扱説明書
iR2623-S3
User Manual
InTANK
» InTANK iR2623-S3 User Manual ..............................................................1
» InTANK iR2623-S3 產品使用說明 ...........................................................12
iR2623-S3 User Manual
V1.5
iR2623-S3 User Manual
1
Table of Contents
1. Package Contents and Product Views
Introduction
Thank you for purchasing RAIDON products. This manual will introduce the IR2623-S3 Series.
Before using your IR2623-S3, please read this manual thoroughly. Although all information contained
in this user manual has been carefully veried before publishing, however, the actual product
specication will be based on the time of delivery from RAIDON. Any updates to the product
specications or relevant information may be found on www.raidon.com.tw. Products are subject
to change without prior notications.
If you have any questions regarding the products of RAIDON, or you would like to know the latest
product information, user manual update, or rmware update, please contact your local supplier or
visit www.raidon.com.tw for further information.
Copyright © RAIDON TECHNOLOGY, INC. All rights reserved.
Open the package and you should nd the following:
1. Package Contents and Product Views
2. Operating Information
3. Hardware Requirements and Precautions
4. Hardware Installation Procedure
5. Setting RAID Mode
6. Computer Set Up
7. Hard Disk status on LCD screen
8. Data Rebuilding Operation
9. GUI Monitoring Software and Firmware Update GUI
10. Frequently Asked Questions
IR2623-S3
IR2623-S3 x 1
( with removable drive tray enclosed )
SATA Cable x 1
Quick Setup Guide x 1
Screws and keys
» InTANK iR2623-S3 User Manual
Please check the product and accessories for any defect or missing parts. If you have any questions,
please contact your product supplier.
Please visit the ocial website (www.raidon.com.tw) to download drivers and other related resources.
iR2623-S3 User Manual
2
13
14
16
19
18
17
15
2
3
4
5
7
8
10
1
9
10
9
6
11
12
FAIL LED
PRI HDD MUTE
SEC HDD
Front View
LED Indicators :
1. 2.5" HDD status indicator LED
2. 2.5" HDD tray ejector opening
3. 2.5" HDD tray ejector handle
4. LCD Display
5. LED of failure Alarm
6. Pri HDD status indicator
7. Sec HDD status indicator
8. Mute Button
9. 3.5" Removable drive tray
10. HDD tray ejector opening
11. Pri HDD tray access light
12. Sec HDD tray access light
13. Cooling fan
14. RAID mode switch
15. RS232 Port
16. 3.5" SATA Port
17. 15 PIN SATA Port
18. 4Pin Power socket
19. 2.5" SATA Port
Status
Panel light 3.5" HDD tray access light
2.5"
HDD tray
access light
Buzzer
Fail LED
Pri HDD
status indicator
Sec HDD
status indicator
Pri HDD tray
access light
Sec HDD tray
access light
Power On — —
Orange light
always on
Blue and Purple light ashing
Blue light
always on
— —
Stabdby — —
Orange light
always on
Blue light
always on
Blue light
always on
— —
HDD
Failure
Red light
always on
— —
Red light
always on
Blue light
always on
On
Access — —
Orange light
always on
Blue and Purple light ashing
Blue light
ashing
— —
Rebuilding
(Source)
— —
Orange light
always on
Blue light
always on
Blue light
always on
— —
Rebuilding
(Target)
— — — —
Red light
ashing
Blue light
always on
— —
Fan Failure
Red light
always on
Orange light
always on
Blue light
always on
Blue light
always on
On
Over Heat
≥50
)
Red light
always on
Orange light
always on
Blue light
always on
Blue light
always on
On
iR2623-S3 User Manual
3
2. Operating Information
3. Hardware Requirements and Precautions
4. Hardware Installation Procedure
Operating Temperature : 0 ~ 40 °C (32 ~ 104 °F)
Storage Temperature : -20 ~ 47 °C (-4 ~ 116 °F)
Line Voltage : 5V DC
1. Computers or servers with SATA I & SATA II & SATA III.
2. Hard drive with SATA I & SATA II & SATA III
3. You are strongly advised to set the storage mode (the default is the Independent mode) before
using the IR2623-S3.
4. The product needs to be restarted after adding or changing the RAID mode, and the update is
guaranteed to be the new RAID mode.
5. The product allows the user to simultaneously utilize two hard drives manufactured by dierent
companies. However, if the user expects better eciency, we strongly recommend the users to
use hard drives manufactured by the same manufacturer.
6. Please make sure that the two hard drives are free from bad blocks or defects prior to installation
in order to avoid system crashes or data loss.
7. The actual storage capacity of IR2623-S3 recognized by the system may differ from the total
capacity stated on the hard drives combined once the drives have been formatted.
8. It is highly recommended for users to back up important data contained within the IR2623-S3
unit on a regular basis or whenever the user feels necessary to a remote or a separate storage
device. Stardom will not be responsible for any lost of data caused during the use of the unit or
the recovery of the data lost.
Please follow the instructions below to complete the hardware installation.
Open the package and take out the product making sure that all the enclosed contents are
not damaged or missing. Should you nd damages or missing contents, please contact your
supplier immediately.
Place the system on a stable surface. Ensure that it is well ventilated without blockage to
the vent and kept away from areas near water and damage prone areas.
Use the key included in the accessory kit and inserted into the key access opening to eject
the removable drive tray latch and extract the removable drive tray.
Mount your hard drives onto the removable drive tray and secure it with the screws included
in the accessory kit to avoid any damage to the hard drive due to accidental movements.
When the hard drive installation has been completed, insert the hard drive tray into the
system horizontally and secure the latch into place.
Use the preferred cable included to connect your computer to the relative interface
connection on the IR2623-S3 unit.
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Note :
Once the drive mode conguration has been completed, re-conguration using the same hard
drives to set the drive mode will result in complete data loss. If you must change the drive
mode, make sure to backup all data prior to the mode change.
iR2623-S3 User Manual
4


󽶶󽶷


󽶴󽶵󽶴
󽶴󽶵󽶴
󽶳
󽶴
󽶵
󽶶
PD3500+
COM1
COM2
1
2
3
4
Note :
1. RS232 Port and RS232 Cable: Provides hardware status monitoring to industrial control system or IPC via RS232.
2. We do not recommend users to disassemble the device without proper instructions and authorization. The manufacture warranty
will not cover the damages caused by unauthorized disassembling.
3. To prevent the device from malfunction, please make sure the device is connected with a direct and dedicated power connection of
a stable power input.
4. RS232 Port: For industrial control system or IPC to monitor the hardware status. More information, please contact your sales
5. Setting the Hard Drive Array Mode
Please select the RAID mode with the jumper located at the back panel. The original default is RAID
1, still there are three pins at the back panel for RAID mode selection: RAID 0 mode by setting the
jumper on the bottom of the two pins. RAID 1 mode by setting the jumper on the top of the two pins.
1. RAID 1 Mode
1). Place two new hard drives into IR2623-S3 and strongly suggest you to use two identical hard
drives to get the equal capacity. If the capacity is dierent, IR2623-S3 is downward to the small
hard drive capacity.
2). Under RAID 1 mode, two hard drives has the identical information as one to mirror to the other
one, therefore each of the hard drive failed is still able to function normally. When you replace
the failed hard disk to the new one the system automatically rebuilding the data to the newly
place hard disk.
2. RAID 0 Mode
1). Place two new hard drives into IR2623-S3 and strongly suggest you to use two identical hard
drives to get the equal capacity. If the capacity is dierent, IR2623-S3 is downward to the small
hard drive capacity.
2). Under RAID 0 mode, capacity is add up to a one big volume, also with the feature of faster
read/write performance ecient.
iR2623-S3
iR2623-S3 User Manual
5
6. Computer Set Up
When the hardware setup for IR2623-S3 is complete, you are now ready to turn the machine on.
After the hardware installation is complete, the IR2623-S3 will be treated as one single hard drive.
Set the hard drive to AUTO in the computer’s BIOS. When the computer is turned on, the system will
retrieve the following information:
1. In IR2623-S3, the installed hard drive can be detected by the Device Manager of Computer
Management for Windows.
2. Customers can choose to format the hard drive by using the Disk Management tool of the
operating system before using the IR2623-S3.
At this point, the installation process is completely nished. The user can freely retrieve and save
data to IR2623-S3 just like retrieving and saving data to a regular hard drive. If the user experiences
any abnormality during the operation, please refer to the trouble shooting Q&A section in Appendix.
iR2623-S3 User Manual
6
7. Hard Disk status on LCD screen
2. Over Temperature (≥50°C)
Pri HDD : OK
Sec HDD : OK T
3. Fan Failure.
Pri HDD : OK F
Sec HDD : OK
4. RAID 1 Degraded. Primary hard drive is failure, but secondary hard drive is normal.
RAID-1 degraded
Pri : X Sec : O
5. RAID 1 Failure. Primary and secondary hard drives are failure.
RAID-1 failure
Pri : X Sec : X
6. RAID 1 Failure. (Double Source)
RAID-1 failure
Double Source
7. RAID 0 Failure. Primary hard drive is missing, but secondary hard drive is normal.
RAID-0 failure
Pri : M Sec :O
8. Rebuilding
Rebuilding
Sec
Pri 32%
1. Booting and Normal status.
IR2623
RAID-1 vxxxxxx.x
Pri HDD : OK
Sec HDD : OK
iR2623-S3 User Manual
7
The hard drive Hot Swap and Auto Rebuilding functions are available.
O-line Back up When the data is stored within IR2623-S3, the user can remove one of the hard
drives from IR2623-S3 as back up drive for data such as system operation le, secured les, seldom
modified files or image and music files. The user can periodically insert the hard drive back into
IR2623-S3 to execute automatic backup to protect the system from being hit by computer virus or to
avoid risk of having both hard drives failing at the same time.
When one of the two hard drives fails in the IR2623-S3 system, the system will alarm the hard
drive failure message both on the LCD display screen and in the monitoring software. The user can
remove the failed hard drive from the system while the system is still in operation without shutting
down the machine. If the failed hard drive is replaced shortly, the system will automatically execute
the Auto Rebuilding function without affecting the system operation and without any operation
command from the user.
When the IR2623-S3 detects a hard drive missing or a hard drive failure, the Buzzer will start and the
LCD display screen will display the following messages:
After removing the failed hard drive and replacing with a new hard drive, if the hard drive is properly
installed, the LCD display screen will display the following messages:
After few seconds of installing the new hard drive, the LCD display screen will display the data
rebuilding progress:
When the rebuilding is fully completed, the LCD display screen will again display the following
messages:
8. Data Rebuilding Operation
Pri HDD : OK
Sec HDD : OK T
RAID-1 degraded
Pri : X Sec : O
Pri HDD : OK
Sec HDD : Insert
Rebuilding
Sec
Pri 32%
Pri HDD :Insert
Sec HDD : OK
Rebuilding
Pri
Sec 32%
iR2623-S3 User Manual
8
You can install GUI software to monitor the status of IR2623-S3. This can be done by installing
software from CD.
The HDD1 equals to Pri HDD and HDD2 equals to Sec HDD.
1. System Status
This GUI will auto detects the connected IR2623-S3 and reveals relative information accordingly.
2. Firmware Upgrade
You may update the Firmware via this GUI, simply click on “Load” button to locate the rmware
le to proceed. After update is nished, you may restart the power properly to operate with newly
updated rmware.
Caution : Any random rmware updates may cause device in malfunction, it is strongly suggested not to update device rmware if
device is operating properly.
9. GUI Monitoring Software and Firmware Update
iR2623-S3 User Manual
9
3. E-Mail Notify
Conguring an e-mail address for notication of drive malfunctioning or being removed.
3-1 Setup
1). Insert “Outgoing” SMTP and e-mail name and address.
2). If it is passwords required, select the option “SMTP Login Authentication” and insert the
passwords.
3). When the conguration completed, click on the “OK” button to save.
Device must be connected in operational states during congurations to take eects.
3-2 HDD Fail / Device Removed
1). Insert the e-mail address of the receiver for notication and click on “+” to add the inserted
e-mail address onto the notifying list. (Maximum up to 10 e-mail addresses)
2). Insert the error message and descriptions from the columns of “Subject” and “Contents”.
3). When the conguration completed, click on the “OK” button to save.
Device must be connected in operational states during congurations to take eects.
iR2623-S3 User Manual
10
5. About Indicates GUI Management Software version
4. S.M.A.R.T.
iR2623-S3 User Manual
11
Unstable system after connecting IR2623-S3
Hard Drive Failure
Q1.
A:
Q2.
A:
After installing IR2623-S3, we are unable to start the computer or the computer can not locate
IR2623-S3 upon startup.
1. Please check whether the readings on the IR2623-S3 LCD display screen appear normal.
2. Please check whether the SATA Cable connection cables are properly connected to the
computer system and whether SATA drives are functioning normally.
3. If everything is functioning properly but the user still can not start the computer system, then
the problem might be the system incompatibility. If such incompatibility takes place, please
contact our technical support department.
When the IR2623-S3 is in use, the computer system is functioning normally but the IR2623-S3
access speed is abnormal.
Please rst check whether the IR2623-S3 is in the progress of executing data auto-rebuild.
1. Please examine if the length of the connection cables, SATA cable that connect the drives to
the computer system is too long and whether the specication these cables complies with the
requirements.
2. If both the lengths and specification of the cables are checked out ok, please turn off
IR2623-S3 and remove the hard drive from IR2623-S3. Test the hard drive directly with the
computer system since it might be the bad sectors in the hard drive that are causing the
longer than normal system down time.
Under the mirror mode (RAID 1), what will be the system’s total storage capacity when adding a
brand new hard drive?
1. The total storage capacity for IR2623-S3 is determined by the storage capacity of the primary
hard drive installed during the initial usage.
2. The storage capacity will not increase after initial installation even when place a brand new
hard drive with larger storage capacity.
10. Frequently Asked Questions
Q1.
A:
Q2.
A:
Why does the error message appear when I installed the second hard drive?
The storage capacity of the second hard drive must be larger than the first hard drive.
Otherwise, IR2623-S3 can not rebuild the new hard drive.
About Auto Rebuilding Function
What will happen if we turn o the computer’s power while IR2623-S3 is still executing data auto
rebuilding?
he mirror mode (RAID 1), if the power is out of the auto rebuilding process, the controller
will remember when completion percentage of the auto rebuilding process and resume the
rebuilding process when the power is back on.
Is it possible to lose any part of the data during the data auto rebuilding?
The data auto rebuilding function will copy data from one sector to another sector. Technically
speaking, the data will not be lost during the auto rebuilding process. However, if the original
hard drive is detected with bad sectors during the rebuilding process, IR2623-S3 will make
hypothetical duplication instead of treat the bad sectors as hard drive failure. Therefore, the data
stored in the bad sectors could potentially be lost during rebuilding.
Q1.
A:
Q2.
A:
iR2623-S3 User Manual
12
» InTANK iR2623-S3 產品使用說明
目錄索引
1. 產品外觀及包裝內容
關於這份手冊
感謝您使用 RAIDON 的產品。本手冊將介紹 InTANK iR2623-S3 產品。在您開始使用 iR2623-S3 產品
前,建議您先閱讀過本手冊。手冊裡的資訊在出版前雖已被詳細確認,實際產品規格仍將以出貨時為
準;任何產品規格或相關資訊更新請您直接到 www.raidon.com.tw 網站查詢,本公司將不另⾏通知。
若您想獲得 RAIDON 最新產品訊息、使用手冊、韌體或對 RAIDON 產品有任何疑問,請您聯絡當地
供應商或到 www.raidon.com.tw 取得相關訊息。
本手冊相關產品內容歸 銳銨科技股份有限公司 版權所有
打開包裝外盒後,包裝內容應包含下列組件:
1. 產品外觀及包裝內容
2. 環境需求
3. 硬體需求與注意事項
4. 硬體安裝
5. 設定 RAID 層級
6. 電腦安裝
7. LCD 訊息顯示
8. 資料重建功能說明
9. GUI 功能說明與韌體更新
10. 常見問題
IR2623-S3
IR2623-S3
產品本體 X1( 內含抽取盒 x3)
SATA x1
快速安裝導引 x 1
螺絲及鑰匙
請確認相關配件與產品本身是否有受損或配件缺少,若有任何疑問請與本產品供應商聯絡。
請前往官網 (www.raidon.com.tw) 下載驅動程式以及其餘相關資源。
iR2623-S3 User Manual
13
13
14
16
19
18
17
15
FAIL LED
PRI HDD MUTE
SEC HDD
2
3
4
5
7
8
10
1
9
10
9
6
11
12
燈號說明
正面與背面示意圖
1. 2.5" 硬碟讀取燈
2. 2.5" 硬碟鑰匙孔
3. 2.5" 硬碟抽盒把手
4. 液晶顯示面板
5. 故障顯示燈
6. 主硬碟狀態指示燈
7. 次硬碟狀態指示燈
8. 靜音按鍵
9. 3.5" 硬碟抽盒把手
10. 硬碟卡榫按鍵
11. 主硬碟讀取燈
12. 次硬碟讀取燈
13. 散熱風扇
14. RAID 模式設定
15. RS232
16. 3.5" 硬碟 SATA 連接埠
17. SATA 15Pin 電源輸入埠
18. 4Pin 電源輸入埠
19. 2.5" 硬碟 SATA 連接埠
狀態
面板燈號 3.5" 硬碟讀取燈
2.5" 硬碟
讀取燈
蜂鳴器
故障顯示燈
主硬碟
狀態指示燈
次硬碟
狀態指示燈
主硬碟
讀取燈
次硬碟
讀取燈
開機 橘燈恆亮 藍紫燈閃爍 藍燈恆亮
待機 橘燈恆亮 藍燈恆亮 藍燈恆亮
硬碟故障
RAID 降級)
紅燈恆亮 紅燈恆亮 藍燈恆亮 鳴叫
資料存取 橘燈恆亮 藍紫燈閃爍 藍燈閃爍
資料重建
(Source)
橘燈恆亮 藍燈恆亮 藍燈恆亮
資料重建
(Target)
紅燈閃爍 藍燈恆亮
風扇故障 紅燈恆亮 橘燈恆亮 藍燈恆亮 藍燈恆亮 鳴叫
溫度過高 紅燈恆亮 橘燈恆亮 藍燈恆亮 藍燈恆亮 鳴叫
iR2623-S3 User Manual
14
2. 環境需求
3. 硬體需求與注意事項
4. 硬體安裝
工作溫度 : 0 ~ 40
o
C (32 ~ 104
o
F)
儲存溫度 :-20 ~ 47
o
C (46 ~ 116
o
F)
工作電壓 : 5V DC
1. 電腦或伺服器具備 SATA ISATA II SATA III 介面。
2. 具備 SATA ISATA II SATA III 介面的硬碟。
3. 強烈建議使用 iR2623-S3 前先設定好 RAID 模式 ( 預設值是 RAID 1)
4. 在新增或變更 RAID 模式後需重新啟動產品,以確保完成更新為新的 RAID 模式。
5. 本系統允許使用不同廠牌的硬碟。但如果要獲得更好的效能,我們強烈建議使用相同廠牌型號的硬
碟。
6. 安裝硬碟前請先確認所使用的硬碟並無壞軌或是其他問題,以免導致系統損毀或資料遺失。
7. 硬碟格式化後,iR2623-S3 的總使用儲存容量或許會與硬碟容量加總後的有所不同。
8. 強烈建議除了使用 iR2623-S3 系列的資料儲存功能外,請針對重要資料備份到另
個儲存裝置上或
遠端備份,雙重備援您重要的資料。若您儲存在 iR2623-S3 系列的資料損毀或遺失RAIDON
不負任何的責任。
請參照以下步驟完成硬體安裝
拆開外包裝並取出產品本體。
將系統擺放於穩固平台,並確認散熱風扇口沒有被其他物體擋住,系統四周有適當的散熱空
間。( 擺放環境請避免接近潮濕或其他易對產品造成損傷的環境。)
請使用零件包內附的頂針插入鑰匙孔後,抽取盒門閂將會輕彈開啟,即可將硬碟抽取盒取出。
將硬碟安裝到抽取盒上,並以零件包內附的螺絲加以固定,以避免不必要的移動對硬碟造成
傷害。
硬碟安裝完成後請將抽取盒平移放入主機內並關上把手。
將附件中的連接線分別接到電腦與 iR2623-S3 的相關連接埠。( 參照以下圖 )
步驟 1
步驟 2
步驟 3
步驟 4
步驟 5
步驟 6
注意:
一旦使用模式確認後 , 使用相同的硬碟進⾏模式切換將會導致資料遺失 . 如果需要進⾏模
式變更 , 請於變更前先進⾏資料備份。
iR2623-S3 User Manual
15


󽶶󽶷


󽶴󽶵󽶴
󽶴󽶵󽶴
󽶳
󽶴
󽶵
󽶶
PD3500+
COM1
COM2
1
2
3
4
Note :
1. RS232 埠與 RS232 線:提供工控系統或是工業電腦透過 RS232 監控硬碟狀態。
2. 我們不建議使用者在未經授權的情況下自⾏拆卸系統。如未經授權自⾏拆卸所導致的損毀將不在保固之列
3. 為了防止系統發生問題,請確保系統的電源供應是穩定且獨立的。
4. RS232 連接埠和 RS232 連接線 : 提供工控產業或 IPC 產業透過 RS232 進⾏硬體狀態偵測,如有需要可向銳銨銷售 / 客服人員
[email protected] 索取相關資料。
5. 設定 RAID 層級
請透過機器後面的 jumper 來設定 RAID 層級。出廠預設值是 RAID 1。機器背面有三根 pin 腳用來設
RAID 層級,若要設定 RAID 0 模式,請選用下面兩根;若要設定 RAID 1 模式,請選用上面兩根。
1. RAID 1 模式
1). 將新的硬碟放入 iR2623-S3 中。強烈建議您使用兩顆相同的硬碟,以便取得對等的容量 . 如果兩
顆硬碟的容量不同,iR2623-S3 將會以小容量的硬碟為依據。
2). RAID 1 模式下,兩顆硬碟是鏡射關係因此擁有相同的資料,因此有一顆硬碟損毀仍然可以正常
運作。當放入新硬碟取代損毀硬碟後,系統會自動將資料重建到新的硬碟。
2. RAID 0 模式
1). 將新的硬碟放入 iR2623-S3 中。強烈建議您使用兩顆相同的硬碟,以便取得對等的容量。如果兩
顆硬碟的容量不同,iR2623-S3 將會以小容量的硬碟為依據。
2). RAID 0 模式下,兩顆硬碟的容量會被加總成一個大儲存容量,並且提供更佳的存取效能
iR2623-S3
iR2623-S3 User Manual
16
6. 電腦安裝
iR2623-S3 的硬體安裝完成,即可準備進⾏⾏開機動作 .
硬體安裝完成後,將 BIOS 的硬碟偵測設定為自動,iR2623-S3 將會被視為如同一顆硬碟一般。
當電腦開機後,系統會顯示下列偵測訊息 :
1. 安裝在 iR2623-S3 中的硬碟能夠被 Windows 的裝置管理員偵測到。
2. 使用 iR2623-S3 前,使用者可以透過磁碟管理選擇硬碟的格式。
到此完成整個安裝程序。使用者可以如同存取一般硬碟般的使用 iR2623-S3。如果使用上仍有問題,
請參閱附件的 Q&A
iR2623-S3 User Manual
17
7. LCD 訊息顯示
2. 溫度過高 (≥50° C)
Pri HDD : OK
Sec HDD : OK T
3. 風扇故障
Pri HDD : OK F
Sec HDD : OK
4. RAID 1 模式,Pri 硬碟損毀而 Sec 硬碟仍然可正常存取
RAID-1 degraded
Pri : X Sec : O
5. RAID 1 損毀,Pri Sec 硬碟皆損毀
RAID-1 failure
Pri : X Sec : X
6. RAID 1 損毀,Source 碟重複
RAID-1 failure
Double Source
7. RAID 0 損毀,Pri Sec 硬碟遺失
9. 資料重建
Rebuilding
Sec
Pri 32%
1. 開機與正常待機狀態
IR2623
RAID-1 vxxxxxx.x
Pri HDD : OK
Sec HDD : OK
RAID-0 failure
Pri : M Sec : O
RAID-0 failure
Pri : O Sec : M
iR2623-S3 User Manual
18
具備硬碟熱抽拔與自動資料重建功能。
離線備份。當資料儲存在 iR2623-S3 後,使用者可以移除其中一顆硬碟當作資料備份碟,確保相關資
料例如作業系統檔案、加密文件、較少存取的檔案甚至影音檔案的安全。使用者可以定期的將硬碟放
IR2623-S3 執⾏自動資料重建,確保系統不會被病毒攻擊或是減少兩顆硬碟同時損毀的風險。
IR2623-S3 中的其中一顆硬碟損毀,系統會透過 LCD 顯示幕與監控軟體發出警示。使用者可以在
系統仍在運作下,無需關掉機機器即可將損毀的硬碟取出。一但替換損毀硬碟後,IR2623-S3 即會在
不影響系統運作的情況下自動開始進⾏資料重建,使用者也無需對 IR2623-S3 下任何指令。
IR2623-S3 偵測到硬碟遺失或是損毀,蜂鳴器會啟動,LCD 螢幕會顯示以下訊息 :
當移除損毀的硬碟並替換一顆新硬碟後,如果新硬碟有正確安裝,LCD 螢幕會顯示以下訊息 :
安裝新硬碟後幾秒鐘,LCD 螢幕會顯示資料重建的進度 :
當資料重建完成後,LCD 螢幕會顯示以下訊息 :
8. 資料重建功能說明
Pri HDD : OK
Sec HDD : OK T
RAID-1 degraded
Pri : X Sec : O
Pri HDD : OK
Sec HDD : Insert
Rebuilding
Sec Pri 32%
Pri HDD :Insert
Sec HDD : OK
Rebuilding
Pri Sec 32%
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25

Raidon iR2623-S3 取扱説明書

タイプ
取扱説明書

他の言語で