10
Positioning
Water heater should position near water tap of use in order to minimize heat loss and defects.
For wall-mount installation, appropriate anchor screws must be used, and wall should be strong
enough to withstand the weight of water heater. Installation position should keep a minimal
distant between the wall and water heater.
Connecting P&T Valve and Inlet/Outlet Pipes
The Temperature & Pressure Relief Valve ( P&T Valve) has applied in water heater, when
the temperature/ pressure in water heater is detected to be more than setting (99°C
/1.0MPa (10bar)),water will be released through the P&T Valve to decrease pressure and
temperature.
P&T Valve and Inlet/Outlet Pipes must be installed according to the following instructions:
1. Please refer to the P&T Valve installation label indicated on the water heater, P&T Valve must
be installed on the accurate position according to the installation label.
2. When connecting the pipe of P&T Valve , the P&T Valve must be installed downward.
The outlet of the discharge pipe connecting the P&T Valve must be positioned approximately
100~150mm away from the ground, so that it is easily observable when hot water is being
drained to ensure user safety.
3. The diameter of piping should be 1/2” BSP. Connect the inlet pipe (blue) with water supply.
Then connect the outlet pipes (red) with supply pipe leading to points of use.
4. Turn on the hot water tap. Turn on water supply switch until the inner tank has been filled up
with water. The inner tank has been filled up when water flows from the water tap.
Power Switch
The external switch is used to completely disconnect water heater from power supply. It should
disconnect all poles, and a contactor separation of at least 3mm must be present.
Initial Operation
Rasonic’s water heater hybrid series is designed for operation on 220VAC, and must be installed
by authorizes technician with earthed outlet.
Fill the inner tank with water before conducting the following procedures:
• Ensure that the appliance is disconnected and that the fuse is deactivated.
• Turn on the hot water tap of the installed mixer to ll the appliance until
bubble-free water emerges from the outlet.
• Check the system for leaks and remedy these if necessary.
• Switch on the appliance.
• The inner tank water temperature will automatic setting and remain in
attendance while the water
Important:
Pre - Installation Notice
Installation and inspection should be processed by a licensed technician using the
supplied parts. Sole Distributor is not responsible for any defect or damage caused by
incorrect or unauthorized installation.
!