TASCAM MD-CD1 & LA-MC1
¤ 1X speed Pit adjustment
7 Pit adjustment (1X speed "EFB Pit")
1) When "Pit Disc Set" is displayed, take out the Recordable
disc, and insert MMD-111 indtead.
2) When the disc is loaded, press the ENTER key and "EFB
Pit" is displayed. If no disc is present, pressing the ENTER
key has no effect on the display. Also, the following
adjustments cannot be made properly if other media than
Pit Discs are loaded.
3) When "EFB Pit" is displayed, press the ENTER key and
"EFB=$xx Pit" is displayed in several seconds.
4) Make adjustment by rotating the multi-jog.
5) After making adjustment for a proper value, press the
ENTER key to save data and complete the process. (This
brings you back to "EFBAL ADJUST".)
ÚAdjustments 1 to 7 above cannot be made half-way through
other processes. Make all of these adjustments in a single
pass.
º Focus bias adjustment ("FBIAS ADJUST")
The focus adjustment is made only for 1X speed.
Connect a jitter meter probe to the RF terminal.
If no jitter meter is available, make adjustment so that value C1
in the display matches what is shown within angle brackets.
But here is a difficulty: value C1 abruptly changes when
approaching an adjustment target point. So we recommend
using a jitter meter.
If you press the CD STOP key in the process of adjustment, the
process is interrupted, bringing you back to "MD ADJUST".
If you interrupt the process, re-do adjustment.
1 MO Disc adjustment
1) When "FBIAS ADJUST" is displayed, insert MMD-221.
2) When the disc is loaded, press the ENTER key and
"C1=xxx a=xx" is displayed in several seconds. If no disc
is present, pressing the ENTER key has no effect on the
display.
3) Rotate the multi-jog clockwise to make adjustment at
point "a" so that the jitter meter registers 30 ns (slightly
exceeded C1=<220>).
4) After making adjustment for a proper value, press the
ENTER key. (The display changes to read "C1=xxx b=xx".)
5) Rotate the multi-jog counterclockwise to make
adjustment at point "b" so that the jitter meter registers
30ns (slightly exceeded C1=<220>)
6) After making adjustment for a proper value, press the
ENTER key. (The display changes to read "C1=xxx c=xx".)
7) A value at point "c" is automatically computed and shown
on the display. (There is no adjustment at point "c".)
8) Press the ENTER key to save data and complete the
process. (This brings you back to "EFBIAS ADJUST".)
7
1 7 1 7
1