Magnescale SJ700A 取扱説明書

タイプ
取扱説明書
/
Instruction Manual / Bedienungsanleitung / 使⽤说明书
Serial No. 700001 and Higher
Scale Unit / Maßstabseinheit / 直线标尺器
SJ700A Series
Read all instructions in the manual carefully before use and strictly follow them.
Keep the manual for future references.
Lesen Sie die ganze Anleitung vor dem Betrieb aufmerksam durch und folgen Sie beim Betrieb des Geräts den
Anweisungen. Bewahren Sie diese Bedienungsanleitung zum späteren Nachlesen gri bereit auf.
感谢您惠购本产品。
使⽤之前请务必认真阅读本⼿册,并且严格按照⼿册中的规定操作。将此⼿册留作以后的参考。
SJ700A-015~160
[For U.S.A. and Canada]
THIS CLASS A DIGITAL DEVICE COMPLIES WITH
PART15 OF THE FCC RULES AND THE CANADIAN
ICES-003. OPERATION IS SUBJECT TO THE
FOLLOWING TWO CONDITIONS.
(1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND
(2) T H I S D E V I C E M U S T A CCEPT ANY
INTERFERENCE RECEIVED, INCLUDING
INTERFERENCE THAT MAY CAUSE
UNDERSIGNED OPERATION.
CET APPAREIL NUMÉRIQUE DE LA CLASSE A
EST CONFORME À LA NORME NMB-003 DU
CANADA.
(E) I
SJ700A
English
Safety Precautions
Magnescale Co., Ltd. products are designed in full consideration of safety. However, improper
handling during operation or installation is dangerous and may lead to fire, electric shock or other
accidents resulting in serious injury or death. In addition, these actions may also worsen machine
performance.
Therefore, be sure to observe the following safety precautions in order to prevent these types
of accidents, and to read these “Safety Precautions” before operating, installing, maintaining,
inspecting, repairing or otherwise working on this unit.
Warning indication meanings
The following indications are used throughout this manual, and their
contents should be understood before reading the text.
Warning
Failure to observe these precautions may lead to fire, electric shock
or other accidents resulting in serious injury or death.
Caution
Failure to observe these precautions may lead to electric shock or
other accidents resulting in injury or damage to surrounding objects.
Note
This indicates precautions which should be observed to ensure
proper handling of the equipment.
Symbols requiring attention
CAUTION ELECTRICAL
SHOCK
Symbols prohibiting actions
DO NOT
DISASSEMBLE
Symbols specifying actions
UNPLUGGING
SJ700A
II (E)
English
Warning
Do not use this unit with voltages other than the specified supply voltage as this may result
in fire or electric shock.
Do not perform installation work with wet hands as this may result in electric shock.
Do not disassemble or modify the unit as this may result in injury or damage the internal
circuits.
Caution
Be sure to check the machine and device conditions to ensure work safety before working
on the machine.
Be sure to cut off the power supply, air and other sources of drive power before working on
the machine. Failure to do so may result in fire or accidents.
When turning on the power supply, etc. to operate the machine, take care not to catch your
fingers in peripheral machines and devices.
(E) III
SJ700A
English
Handling Precautions
Installation precautions
When installing this unit, care should be given to the following points to prevent noise and
electromagnetic wave interference from other equipment.
1. Do not pass lead and connection cables through the same ducts as power lines.
2. Be sure to install the unit at least 0.5 m (20") or more away from high voltage or large
current sources or high-power relays.
3. Absolutely do not bring the unit near magnets or sources of electromagnetic waves.
Note
Magnet chucks and other sources of magnetic force of approx. 600×10–4T (600 G)
should be kept at least 50 mm (2") or more away from the side surfaces and 100 mm (4")
or more away from the opening surfaces of the scale's steel chassis.
If the unit must be installed close to sources of magnetic force, be sure to implement
adequate electromagnetic shielding countermeasures.
Installation place precautions
1. Mount the scale for more precise positioning as closely as possible to the workpiece or to
the object being measured.
(The farther the scale is mounted from workpiece, the greater the mechanical errors grow.)
2. The scale unit should be used within an ambient temperature range of 0 to 40°C. Avoid
locations where the scale is exposed to direct sunlight and heat sources such as motors.
3. Do not place anything on the mounted scale, or step on it: excessive force to the scale
causes trouble.
4. Never install the scale in locations such as places where the scale could be exposed
directly to coolant liquid or to coolant in mist form.
SJ700A
IV (E)
English
General precautions
When using Magnescale Co., Ltd. products, observe the following
general precautions along with those given speci cally in this
manual to ensure proper use of the products.
Before and during operations, be sure to check that our products
function properly.
Provide adequate safety measures to prevent damage in case
our products should develop a malfunction.
Use outside indicated speci cations or purposes and
modi cation of our products will void any warranty of the
functions and performance as speci ed for our products.
When using our products in combination with other equipment,
the functions and performance as noted in this manual may not
be attained, depending upon the operating environmental
conditions. Make a thorough study of the compatibility in
advance.
(E) i
SJ700A
English
Contents
1. Outline .............................................................................. 1
1-1. Introduction ..............................................................................1
1-2. Major Features ..........................................................................1
1-3. Parts Con guration ................................................................ 1
1-4. System Con guration ............................................................ 2
2. Name and Function of Each Part .................................... 3
3. Mounting Method ............................................................ 5
3-1. Mounting Precautions ...........................................................5
3-1-1. Checking the mounting method ....................... 5
3-1-2. Setting the operating range ................................ 6
3-1-3. Protection of the head cable .............................. 6
3-1-4. Mounting a protective cover ...............................6
3-2. Required Items for Mounting .............................................7
3-3. Mounting Procedure ..............................................................8
3-4. Mounting Dimensions ...........................................................8
3-4-1. Mounting of the scale ............................................9
3-4-2. Mounting of the slider .......................................... 11
3-4-3. Removal of the slider holder ..............................14
3-4-4. Checking of the operating range .....................15
3-4-5. Mounting of the conduit cable .........................15
3-4-6. Connection of the head cable to
a counter unit ..........................................................16
3-4-7. Removal of the scale .............................................17
4. Speci cations ................................................................. 18
4-1. General Speci cations .........................................................18
4-2. Dimensions ..............................................................................19
5. Trouble Information ...................................................... 20
SJ700A
ii (E)
English
(E) 1
SJ700A
English
1. Outline
1-1. Introduction
SJ700A series of linear scales are semi-modular types that
incorporate the detector inside the scale, and the relative
positions of their scale and head are adjusted and secured using a
slider holder.
e SJ700A series may be used as is by connecting it to a
Magnescale Co., Ltd. counter unit (LG20, LH70 series).
1-2. Major Features
Compact size and light weight
Easy to install
Same coe cient of expansion as that of machine tools
Highly resistant to oils and dirt
1-3. Parts Con guration
Scale unit Scale .......................................................... 1
Accessories
Cable clamps ................................................... 4
(For securing the conduit cable)
+P 4 × 10 ............................................................ 4
(For securing wires)
Spacer s ............................................................... 5
(For securing the slider)
HSB M4 × 10 ..................................................... 3
(For securing the scale)
Screening label ............................................... 1
(For covering the screw holes when
the slider holder is removed)
HSB M4 × 14 ..................................................... 2
(For securing the slider)
Plain washers (S) ............................................. 2
(For securing the slider)
HSB M5 × 25 ..................................................... 2
(For securing the slider)
Plain washers (M) ........................................... 3
(For securing the scale)
Nuts (for M5) .................................................... 2
(For securing the slider)
Instruction manual ......................................................................................................1
SJ700A
2 (E)
English
1-4. System Con guration
System configuration
Scale unit Counter
(optional)
LG20
LH70
Series
Model line up
Unit: mm (inch)
Model name Measuring length Cable length
SJ700A-015 150 (5.91")
3000 (118.11")
SJ700A-025 250 (9.84")
SJ700A-035 350 (13.78")
SJ700A-040 400 (15.75")
SJ700A-050 500 (19.69")
SJ700A-065 650 (25.59")
SJ700A-080 800 (31.50")
SJ700A-095 950 (37.40")
5000 (196.85")
SJ700A-105 1050 (41.34")
SJ700A-125 1250 (49.21")
SJ700A-140 1400 (55.12")
SJ700A-160 1600 (62.99")
(E) 3
SJ700A
English
2. Name and Function of Each Part
Serial No.
******
Alignment mark
Scale mounting hole
Measuring length
mark (left)
Side cover L
Center foot plate securing hole
Slider holder
Model name Side cover R
Serial No.
Measuring length
mark (right)
Slider
Interface unit
Slider mounting hole
Slider center
Conduit cable
Center foot plate
Interface unit tap for xing
Status lamp
SJ700A
4 (E)
English
a Slider
is holds the detection head. When shipped, it is secured by
the slider holder.
b Slider center
is indicates the mechanical center of the slider. It serves as
a reference when viewing the relative position with the
measuring length marks.
c Measuring length marks
ese indicate the e ective movement range over which
accuracy is assured with respect to the slider center.
Note
When mounting and using the scale unit, be sure to operate
the unit within this range. Using the scale unit in excess of
the e ective movement range may damage the unit.
d Slider holder
is secures the scale body and slider, and should be stored
a er removal.
e Model name
is indicates the scale unit model name.
f Serial No.
is indicates the scale unit serial No.
g Center foot plate
is is mounted when the measuring length is 1250 mm or
more, and should be secured when mounting the scale unit.
h Interface unit
is is connected to the rear panel of the counter unit.
e interface unit contains an internal circuit which is
electrically adjusted to the optimal setting.
i Status lamp
is is a lamp for checking the signals.
Lit green : Normal
Lit orange : Warning (Signal level drop)
Lit red : Error (Signal level drop)
Blinking red : Error (Overspeed)
j Interface unit tap for  xing
e interface unit can be secured in place using the supplied
xing plate and screw. (M3 depth 3 mm)
(E) 5
SJ700A
English
When mounting the scale vertically, be sure to mount the scale
slider on the opposite side of a workpiece or cutting tool.
Slider
Scale
Cutting tool
Fig. 3-2 Mounting the scale vertically
3. Mounting Method
3-1. Mounting Precautions
3-1-1. Checking the mounting method
Check that the scale unit can be mounted in the relative position
shown in the Fig. 3-1.
* Do not mount the scale in any other direction since di culties
with servicing and maintenance may arise.
(Mounting position B is available only when the scale can be
protected from cutting oil and chips. (See “3-1-4”))
(Recommended
mounting position) BA
Fig. 3-1 Scale mounting direction
SJ700A
6 (E)
English
3-1-2. Setting the operating range
e measuring length of the scale is the distance between the
measuring length marks (Ø) at both ends of the scale.
Mount the scale in such a position that the slider center moves
within these measuring length marks.
A leeway (10 mm (0.39") on the le and right) is provided for
the slider movement. Take special care not to move the slider
beyond this limit or the scale may be damaged.
Slider center
Measuring length mark
Mount the scale so that the slider center moves within this range.
(Eective movement range)
Fig. 3-3 Operating range
Mechanical limiting devices (stoppers, etc.) are required for
sliders which move in excess of the e ective movement range
of the scale unit. In these cases, be sure to take the appropriate
measures before mounting the scale unit.
3-1-3. Protection of the head cable
e head cable and scale come as a single integrated unit. Take
care not to pull the head cable forcefully or bend it repeatedly or
the cable may break.
3-1-4. Mounting a protective cover
If the scale is mounted in a location where it may be exposed
directly to chips or cutting oil, it is recommended that a protective
cover such as the one shown in Fig. 3-4 be installed so that the
scale is not exposed to the outside as far as possible.  is will
help to maintain the scale's performance.
Fig. 3-4 Example of protective cover
(E) 7
SJ700A
English
3-2. Required Items for Mounting
Accessories (supplied)
Hex socket head cap screw .............................................................. 3
M4 × 10 for mounting scale
(Use 2 for scales with a measuring length
less than 1,250 mm (49.21").)
Hex socket head cap screw .............................................................. 2
M4 × 14 for mounting slider
Pan head screw .................................................................................. 4
M4 × 10 for cable clamp
Plain washer (M) ............................................................................... 3
with 4 mm (0.16") dia. hole
(Use 2 for scales with a measuring length
less than 1,250 mm (49.21").)
Plain washer (S) ................................................................................. 2
with 4 mm (0.16") dia. hole for mounting slider
Cable clamp for mounting conduit cable (M) .............................. 4
Screening label ................................................................................... 1
for concealing the screw holes a er the slider holder
has been removed
Hex socket head cap screw .............................................................. 2
M5 × 25 for mounting slider
Hex nut ............................................................................................... 2
M5 for mounting slider
Spacer .................................................................................................. 5
t = 0.1 for mounting slider
Tools you need other than the supplied accessories.
Bracket for mounting scale (for A B surfaces) .........................1 to 2
Bracket for mounting slider (for C surface) ..................................... 1
Dial indicator with magnetic base capable of reading
0.01 mm (0.0005") .........................................................................1 to 2
Allen wrench for M2.6 (2 mm (0.079")) type .................................. 1
Allen wrench for M4 (3 mm (0.118")) type ...................................... 1
Allen wrench for M5 (4 mm (0.157")) type ...................................... 1
Phillips head screwdriver for M2.6 ................................................... 1
Tap M4 ................................................................................................... 1
Drill ø3.2 (0.126") dia .......................................................................... 1
Electrical drill ....................................................................................... 1
Liner, spacer t = 0.05 to 0.2 mm (0.002 to 0.08") .....................Some
Phillips head screwdriver No.2 .......................................................... 1
Note: L= measuring length
t = thickness
SJ700A
8 (E)
English
3-3. Mounting Procedure
Precautions
e procedures for mounting the scale unit are described below.
For the scale unit, the only disassembly process during the
mounting work is removing the slider holder. (See “3-4-3”.) Do
not disassemble other locations.
e scale unit is comprised of precision mechanical and
electromagnetic parts, so applying excessive force will have a
large e ect on the unit's performance and service life.  erefore,
take care not to apply excessive force when mounting the scale
unit.
In addition, when carrying the unit, the scale body and slider
should be held together. Take care not to carry the scale by the
head cable or interface unit.
3-4. Mounting Dimensions
Unit: mm (inch)
8 (0.31") or more
(20(0.79"))
24(0.94")
25(0.98")
25(0.98")
(60(2.36"))
63(2.48")
A
B
C
Fig. 3-5 Mounting dimensions
(E) 9
SJ700A
English
3-4-1. Mounting of the scale
<1> When the mounting surface already meets
parallelism and flatness requirements
When the scale mounting surface is  nished and meets the
parallelism and  atness speci cations below, just mount the
scale. (For scales of L < 1250 mm (49"), use two M4 × 10 hex
socket head cap screws and two plain washers (M); for scales of
L > 1250 mm (49"), use three M4 × 10 hex socket head cap
screws and three plain washers (M). Tightening torque:
350 N·cm/35 kgf·cm)
Flatness of A, B surfaces
within 0.15 mm (0.006")
Parallelism of A, B surfaces to
machine table movement
Provide the range shown in Fig. 3-5 for surface A.
e above tolerances suppose no quick change in the surfaces
and no obstacle in the way between the right and le mounting
surfaces.
<2> When the scale mounting surface is a casting
surface
Mount the scale using mounting brackets
(1) When the scale mounting surface is a casting
surface and parallelism is not satis ed
Use mounting brackets and adjust so that the parallelism
speci ed in <1> may be satis ed.
Mounting brackets are only necessary at the le and right
foot areas of the scale.  ey do not need to extend the entire
length of the scale. However, if it is not possible to measure
the parallelism of the le and right feet due to the movable
length of the mounted unit, it will be necessary to make
longer mounting brackets.
Shorter than the machine table stroke
Mounting bracket
Fig. 3-6 Length of mounting brackets and measurement
of their parallelism
SJ700A
10 (E)
English
(2) Checking of mounting position and tapping
Check that the parallelism for mounting scale meets the
speci cations, and then tap for M4 screws of 10 mm (0.39")
depth referring to the Dimensions on page 19.
(3) Mounting of the scale
Mount the scale loosely with M4 × 10 hex socket head cap
screws and plain washers (M), and leave it for 30 minutes for
the scale to reach ambient temperature.  en rmly mount
the scale.
(4) Measuring parallelism of scale with machine table
movement
Place a dial gauge directly where the alignment mark (Fig.
3-7 a in the  gure below) is positioned on the side of the
scale, and check that the scale is surely mounted parallel to
the machine table movement.
Alignment mar
k
b
a
Fig. 3-7 Parallelness check of scale and machine table movement
Adjust the parallelism of the length between the two alignment
marks to within 0.15 mm (0.006") and tighten the setscrews.
For the scale with a measuring length of 1250 (49.21") or more,
adjust the parallelisms of the lengths between the alignment mark
and those on both sides of it to within 0.15 mm (0.006").
Note
Since alignment marks are not provided on scales with a
measuring length of 250 mm (9.8") or less, place the dial gauge
on the scale unit and ensure that the allowance at the two ends of
the machine travel is within 0.15 mm (0.006").
M4 × 10
Parallel ness allowance
within 0.15 mm( 0.006")
Center foot plate
Alignment marks
Plain washer (M)
Fig. 3-8 Parallelism check by alignment marks
(E) 11
SJ700A
English
(5) When the speci ed parallelism for the scale
mounting bracket is not obtained
Insert spacers below the feet and make adjustment by placing
a dial gauge at b in Fig. 3-7 to adjust the parallelism to within
0.15 mm (0.006") throughout the length between may be
obtained at the alignment marks.
For scales equipped with a center foot plate (measuring length
1,250 to 1,600 mm (49.21 to 62.99 inch)), make sure that the
parallelism near the center foot plate is also within 0.15 mm
(0.006").
3-4-2. Mounting of the slider
(1) When parallelism and  atness of the mounting
surface are already satis ed
When the mounting surface is  nished and its parallelism
and  atness satisfy the speci cations below, just mount the
slider using two M4 × 14 hex socket head cap screws and
two plain washers (S).
e mounting dimensions di er depending on the clearance
between the B and C surfaces.
Flatness of C surface within 0.1 mm (0.004")
Parallelism of C surface to
machine table movement 0.1 mm/60 mm (0.004"/2.36")
Parallelism between B and
C surfaces
Clearance between B and
C surface
8.7 to 8.9 mm (0.343" to 0.350")
9 mm (0.35") ±0.1 mm (0.004")
If clearance between B and C surfaces is set to
between 8.7 and 8.9 mm
Move the machine table till the mounting surface comes just at
the slider. First use the spacers provided to  ll the gap between the
mounting surface and slider, and then secure the slider.  en
remove the screws which  x slider holder. (If the gap is still not
lled, check the gap between the B and C surfaces and adjust it
is necessary.)
SJ700A
12 (E)
English
If the gap between the B and C surfaces is set to
9 ±0.1 mm (0.354" ±0.004").
Remove the two screws securing the scale and the slider holder
and move the slider by hand to align it with the brackets.
Secure the slider in place in the position where the protruding
portion (D) of the slider holder comes into contact with the
scale. Finally, remove the slider holder from the slider.
Note
Attempting to move the bracket side when the slider holder is
secured could cause the brackets to strike the slider.  erefore,
always move only the slider side.
Slider holder
Protruding
portion (D)
Clearance between
B and C surface Unit: mm (inch)
52 ±0.3 (2.048" ±0.012")
B
C
Fig. 3-9
(2) When the slider mounting surface has yet to meet
the speci cations
When the mounting surface of the machine is a casting
surface, use a bracket. Place the bracket on the underside of
the slider without loosening the screws that hold the slider
holder. Adjust the position of the bracket and mount it with
the supplied M4 × 14 bolts.
Slider holder Scale
2 Plain washers
(S) (accessory)
26 (1.02") or less
2-M4 × 14
(accessory)
Mounting bracket
Slider 4 (0.16") to 6 (0.24")
Unit: mm (inch)
Fig. 3-10
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84

Magnescale SJ700A 取扱説明書

タイプ
取扱説明書