Dell PowerEdge R805 クイックスタートガイド

タイプ
クイックスタートガイド
Dell™ PowerEdge™
R805 Systems
Getting Started
With Your System
系统使用入门
はじめに
시스템시작하기
Dell™ PowerEdge™
R805 Systems
Getting Started
With Your System
Notes, Notices, and Cautions
NOTE: A NOTE indicates important information that helps you make better use
of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data
and tells you how to avoid the problem.
CAUTION: A CAUTION indicates a potential for property damage, personal injury,
or death.
____________________
Information in this document is subject to change without notice.
© 2007 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly
forbidden.
Trademarks used in this text: Dell and the DELL logo are trademarks of Dell Inc.; AMD and AMD
Opteron are registered trademarks of Advanced Micro Devices; Microsoft, Windows, and Windows
Server are registered trademarks of Microsoft Corporation; Novell and NetWare are registered
trademarks of Novell, Inc.; Red Hat and Red Hat Enterprise Linux are registered trademarks
of Red Hat, Inc.; SUSE is a registered trademark of Novell Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.
Model EMS01
August 2007 P/N CR241 Rev. A00
Getting Started With Your System 3
System Features
This section describes the major hardware and software features of your
system. It also provides information about other documents you may need
when setting up your system and how to obtain technical assistance.
Two dual-core or quad-core AMD Opteron™ processors.
A minimum of 2 GB single- or dual-ranked 667-MHz DDR2 (PC2-5300)
memory modules (installed in two sets of pairs). Memory is upgradable to
a maximum of 128 GB by installing combinations of 512-MB, 1-GB, 2-GB,
4-GB, or 8-GB memory modules in the 16 memory module sockets
(eight per CPU) on the system board.
Support for up to two 2.5-inch, internal hot-pluggable Serial Attached
SCSI (SAS) or SATA hard drives.
An optional slim-line SATA DVD-ROM drive, slim-line SATA DVD-RW
drive, or combination CD-RW/DVD drive (when available).
NOTE: DVD devices are data only.
An intrusion switch that signals the appropriate systems management
software if the cover is opened.
Up to two hot-pluggable, 700-W power supplies in an optional 1 + 1
redundant configuration.
Six hot-pluggable system cooling fans.
Optional support for iSCSI boot.
The system board includes the following features:
A right riser card (riser 1) containing two PCIe (x4 and x8) slots. The right
riser card also contains an SD (Secure Digital) slot for embedded OS
support.
A left riser card (riser 2) containing one full-length PCIe (x8) slot
and one half-length PCIe (x8) slot.
An integrated SAS controller card (via a dedicated PCIe slot on the
sideplane board) supporting both SAS 6i/R and PERC 6/i adapters.
Optional integrated PERC controller (PERC 6i) with integrated cache
and battery backup.
Four integrated Gigabit Ethernet NICs, capable of supporting 10-Mbps,
100-Mbps, and 1000-Mbps data rates.
4 Getting Started With Your System
Four external USB 2.0-compliant connectors (two on the front and two
on the back) supporting a diskette drive, a DVD-ROM drive, a keyboard,
a mouse, or a USB flash drive.
One internal USB 2.0-compliant connector supporting an optional
bootable USB flash drive or USB security key.
Optional remote access controller (RAC) for remote systems management.
An integrated VGA-compatible video subsystem based on an integrated
ATI ES1000 33-MHz PCI video controller. The video subsystem includes
32MB of graphics memory and supports various 2D graphics video modes.
Maximum resolution is 1600x1200 with 65,536 colors. (When the optional
RAC is installed, the maximum resolution of the integrated video
subsystem is 1280x1024.)
Systems management circuitry that monitors operation of the system fans
as well as critical system voltages, temperatures, and system power
consumption. The systems management circuitry works in conjunction
with the systems management software.
Standard Baseboard Management Controller (BMC) with serial and LAN
access.
Back-panel connectors include one serial, one video, two USB,
and four NIC connectors.
Front-panel connectors include a video and two USB connectors.
Front-panel 1x5 LCD for system ID and error messaging.
System ID button on the front and back panels.
For more information about specific features, see Technical Specifications.
Supported Operating Systems
Microsoft
®
Windows Server
®
2003 R2 Standard and Enterprise Editions
(SP1 and later)
Microsoft Windows Server 2003 R2 Standard and Enterprise x64 Editions
(SP1 and later)
Red Hat Enterprise Linux Server 5 (x86)
Red Hat Enterprise Linux Server 5 (x86_64)
Red Hat Enterprise Linux Server ES (Version 4.5) (x86)
Getting Started With Your System 5
Red Hat Enterprise Linux Server ES (Version 4.5) (x86_64)
•SUSE
®
Linux Enterprise Server 9 (x86_64)
SUSE Linux Enterprise Server 10 (x86_64)
•VMware
®
ESX Server 3 (including embedded versions)
NOTE: For the latest information on supported operating systems, see www.dell.com.
NOTE: SUSE Linux Enterprise Server 9, prior to SP4, does not support SATA optical
devices. Installation must be performed using other methods, such as an external
USB CD-ROM drive.
Other Information You May Need
CAUTION: The Product Information Guide provides important safety and
regulatory information. Warranty information may be included within this
document or as a separate document.
The
Rack Installation Guide
or
Rack Installation Instructions
included
with your rack solution describes how to install your system into a rack.
The
Hardware Owner’s Manual
provides information about system
features and describes how to troubleshoot the system and install or
replace system components.
CDs included with your system provide documentation and tools for
configuring and managing your system.
Systems management software documentation describes the features,
requirements, installation, and basic operation of the software.
Operating system documentation describes how to install (if necessary),
configure, and use the operating system software.
Documentation for any components you purchased separately provides
information to configure and install these options.
Updates are sometimes included with the system to describe changes
to the system, software, and/or documentation.
NOTE: Always check for updates on support.dell.com and read the updates
first because they often supersede information in other documents.
Release notes or readme files may be included to provide last-minute
updates to the system or documentation or advanced technical reference
material intended for experienced users or technicians.
6 Getting Started With Your System
Obtaining Technical Assistance
If you do not understand a procedure in this guide or if the system does
not perform as expected, see your Hardware Owner’s Manual.
Dell™ Enterprise Training and Certification is available; see
www.dell.com/
training
for more information. This service may not be offered in all locations.
Installation and Configuration
CAUTION: Before performing the following procedure, read and follow the
safety instructions and important regulatory information in your Product
Information Guide.
This section describes the steps to set up your system for the first time.
Unpacking the System
Unpack your system and identify each item.
Keep all shipping materials in case you need them later.
NOTE: Depending on options ordered, not all components shown may be
included.
Getting Started With Your System 7
Installing the Rails and System in a Rack
Once you have read the "Safety Instructions" located in the rack
installation documentation for your system, install the rails and the system
in the rack.
See your rack installation documentation for instructions on installing
your system in a rack.
Connecting the Keyboard, Mouse, and Monitor
Connect the keyboard, mouse, and monitor (optional).
The connectors on the back of your system have icons indicating
which cable to plug into each connector. Be sure to tighten the screws
(if any) on the monitor's cable connector.
8 Getting Started With Your System
Connecting the Power
Connect the monitor’s power cable to the monitor (optional), and connect
the system’s power cable(s) to the system.
Installing the Power Cord Retention Bracket
Attach the power cord retention bracket on the right bend of the power
supply handle. Bend the system power cable into a loop as shown in the
illustration and attach to the bracket’s cable clasp. Repeat the procedure
for the second power supply.
Plug the other end of the power cables into a grounded electrical outlet
or a separate power source such as an uninterrupted power supply (UPS)
or a power distribution unit (PDU).
Getting Started With Your System 9
Turning on the System
Turn on the system and monitor (optional).
With the bezel removed, press the power button on the system and the
monitor. The power indicators should light. Adjust the monitor's controls
until the displayed image is satisfactory.
Installing the Bezel
Install the bezel (optional).
10 Getting Started With Your System
Complete the 0perating System Setup
If you purchased a preinstalled operating system, see the operating system
documentation that ships with your system. To install an operating system for
the first time, see the Quick Installation Guide. Be sure the operating system
is installed before installing hardware or software not purchased with the
system.
Technical Specifications
Processor
Processor type Two dual- or quad-core AMD Opteron processors
Expansion Bus
Bus type PCIe
Expansion slots
Right riser (riser 1):
PCIe
One x8 full-height, full-length slot (top)
One x4 full-height, half-length slot (bottom)
One internal SD (Secure Digital) card slot
Left riser (riser 2):
PCIe
One x8 full-height, full-length slot (top)
One x8 full-height, half-length slot (bottom)
One internal USB key socket
Memory
Architecture 667-MHz registered parity DDR2 memory
modules
Memory module sockets 16 240-pin
Memory module capacities 512 MB, 1 GB, 2 GB, 4 GB, or 8 GB (single-
or dual-rank only, quad-rank not supported)
Minimum RAM
(installed in two sets of pairs)
2 GB (1 GB each processor, 2 DIMMs
per processor)
Maximum RAM 128 GB (64 GB each processor)
Getting Started With Your System 11
Drives
Hard drives Up to two 2.5-inch, hot-plug SAS or SATA
internal drives
Optical drive One optional slim-line SATA DVD-ROM drive or
DVD-RW drive, or combination CD-RW/DVD
drive (when available)
NOTE: DVD devices are data only.
External optional USB DVD
Flash drive External optional USB
Internal optional USB
Internal optional SD card
Connectors
Back
NIC
Four RJ-45 10/100/1000
Serial
9-pin, DTE, 16550-compatible
USB
Two 4-pin, USB 2.0-compliant
Video
15-pin VGA
Front
Video
15-pin VGA
USB
Two 4-pin, USB 2.0-compliant
Internal
USB
One 4-pin, USB 2.0-compliant
SD
One flash memory card slot on right PCIe riser
(riser 1)
Video
Video type ATI ES1000 video controller; VGA connector
Video memory 32 MB
12 Getting Started With Your System
Power
AC power supply (per power supply)
Wa tt ag e
700 W
Voltage
85–264 VAC, autoranging, 47–63 Hz
Heat dissipation
2697 BTU/hr maximum
Maximum inrush current
Under typical line conditions and over the entire
system ambient operating range, the inrush
current may reach 55 A per power supply
for 10 ms or less.
Batteries
System battery
CR 2032 3.0-V lithium ion coin cell
RAID battery (optional)
4.1-V lithium ion
Physical
Height
8.67 cm (3.41 in)
Width
44.4 cm (17.5 in)
Depth
71.26 cm (28.05 in)
Weight (maximum
configuration)
20.23 kg (44.6 lb)
Getting Started With Your System 13
Environmental
NOTE: For additional information about environmental measurements for specific
system configurations, see www.dell.com/environmental_datasheets.
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE: For altitudes above 2950 feet, the maximum
operating temperature is derated 1ºF/550 ft.
Storage
–40° to 65°C (–40° to 149°F) with a maximum
temperature gradation of 20°C per hour
Relative humidity
Operating
20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour
Storage
5% to 95% (noncondensing) with a maximum
humidity gradation of 10% per hour
Maximum vibration
Operating
0.26 Grms at 5–350 Hz in operational
orientations
Storage
1.54 Grms at 10–250 Hz in all orientations
Maximum shock
Operating
One shock pulse in the positive z axis (one pulse
on each side of the system) of 31 G for 2.6 ms
in the operational orientation
Storage
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 71 G for up to 2 ms
Altitude
Operating
–16 to 3048 m (–50 to 10,000 ft)
NOTE: For altitudes above 2950 feet, the maximum
operating temperature is derated 1ºF/550 ft.
Storage
–16 to 10,600 m (–50 to 35,000 ft)
14 Getting Started With Your System
Dell™ PowerEdge™ R805
系统
系统使用入门
型号
EMS01
注、注意和警告
注:“注”表示可以帮助您更好地使用计算机的重要信息。
注意:“注意”表示可能会损坏硬件或导致数据丢失,并告诉您如何避免
此类问题。
警告:“警告”表示可能会出现导致财产损失、人身伤害甚至死亡的情况。
____________________
本说明文件中的信息如有更改,恕不另行通知。
© 2007 Dell Inc.
版权所有,翻印必究。
未经
Dell Inc.
书面许可,严禁以任何形式进行复制。
本文中使用的商标:
Dell
DELL
徽标是
Dell Inc.
的商标;
AMD
AMD Opteron
Advanced Micro Devices
的注册商标;
Microsoft
Windows
Windows Server
Microsoft
Corporation
的注册商标;
Novell
NetWare
Novell, Inc.
的注册商标;
Red Hat
Red Hat
Enterprise Linux
Red Hat, Inc.
的注册商标;
SUSE
Novell Inc.
的注册商标。
本文件中述及的其它商标和产品名称是指拥有相应商标和名称的公司或其制造的产品。
Dell Inc.
对本公司的商标和产品名称之外的其它商标和产品名称不拥有任何专有权。
型号
EMS01
2007
8
P/N CR241 Rev. A00
系统使用入门 17
系统配置
本节介绍系统的主要硬件和软件配置。另外,还介绍了有关在安装系统时
可能需要的其它说明文件的信息,以及如何获得技术帮助的信息。
两个双核或四核
AMD Opteron™
处理器。
最低
2 GB
单排或双排
667 MHz DDR2 (PC2-5300)
内存模块(两组成
对安装)。通过在系统板上的
16
个内存模块插槽(每个
CPU
八个)
中安装
512 MB
1 GB
2 GB
4 GB
8 GB
内存模块组合,最大可将
内存升级到
128 GB
支持最多两个
2.5
英寸内部热插拔串行连接
SCSI (SAS)
SATA
硬盘
驱动器。
可选的细长型
SATA DVD-ROM
驱动器、细长型
SATA DVD-RW
驱动
器或组合
CD-RW/DVD
驱动器(可用时)。
注:DVD 设备仅用于数据。
防盗开关,在盖被打开时会向相应的系统管理软件发送信号。
最多两个
700 W
热插拔电源设备(可选
1 + 1
冗余配置)。
六个热插拔系统冷却风扇。
可选的
iSCSI
引导支持。
系统板包含以下配置:
包含两个
PCIe
x4
x8
)插槽的右提升卡(提升卡
1
)。右提升卡还
包含一个用于嵌入式
OS
支持的
SD
(安全数字)插槽。
包含一个全长
PCIe (x8)
插槽和一个半长
PCIe (x8)
插槽的左提升卡
(提升卡
2
)。
一个集成的
SAS
控制器卡,(通过侧板上的专用
PCIe
插槽)
支持
SAS 6i/R
PERC 6/i
适配器。
可选的集成
PERC
控制器
(PERC 6i)
,具有集成高速缓存和备用电池。
四个集成的千兆位以太网
NIC
,可支持
10 Mbps
100 Mbps
1000 Mbps
数据速率。
四个外部
USB 2.0
兼容连接器(两个在正面,两个在背面),可支持
软盘驱动器、
DVD-ROM
驱动器、键盘、鼠标或
USB
快擦写驱动器。
一个内部
USB 2.0
兼容连接器,可支持一个可选的可引导
USB
快擦写
驱动器或
USB
安全保护密钥。
可选的远程访问控制器
(RAC)
,用于远程系统管理。
18 系统使用入门
一个基于集成的
ATI ES1000 33-MHz PCI
视频控制器的
VGA
兼容集成
视频子系统。此视频子系统包含
32 MB
的图形内存,并支持各种
2D
图形视频模式。最大分辨率为
1600 x 1200
65,536
色)。(如果安装
了可选的
RAC
,则集成视频子系统的最大分辨率为
1280x1024
。)
系统管理电路,可监测系统风扇的运行以及系统临界电压、温度和系
统电源消耗。系统管理电路需要与系统管理软件配合工作。
标准底板管理控制器
(BMC)
,支持串行访问和
LAN
访问。
背面板连接器包括一个串行连接器、一个视频连接器、两个
USB
连接
器和四个
NIC
连接器。
前面板连接器包括一个视频连接器和两个
USB
连接器。
前面板
1x5 LCD
显示屏,用于显示系统
ID
和错误信息。
系统
ID
按钮,位于前面板和背面板上。
有关特定配置的详细信息,请参阅技术规格。
支持的操作系统
Microsoft
®
Windows Server
®
2003 R2
标准版和企业版(
SP1
和更高版本)
Microsoft Windows Server 2003 R2 x64
标准版和企业版(
SP1
和更高版本)
Red Hat Enterprise Linux Server 5 (x86)
Red Hat Enterprise Linux Server 5 (x86_64)
Red Hat Enterprise Linux Server ES
4.5
版)
(x86)
Red Hat Enterprise Linux Server ES
4.5
版)
(x86_64)
SUSE
®
Linux Enterprise Server 9 (x86_64)
SUSE Linux Enterprise Server 10 (x86_64)
VMware
®
ESX Server 3
(包括嵌入式版本)
注:有关支持的操作系统的最新信息,请参阅 www.dell.com
注:SUSE Linux Enterprise Server 9SP4 以前的版本)不支持 SATA 光驱。
必须使用其它方法(如外部 USB CD-ROM 驱动器)才能进行安装。
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58

Dell PowerEdge R805 クイックスタートガイド

タイプ
クイックスタートガイド