5100, 5100C, 5400C, 5403 and 5400 Vision
System Specifications
Specification 5100/5110 5100C 5400C 5403/5413 5400/5410
Operating Temperature 0°C to 45°C (32°F to 113°F)
Storage Temperature -30°C to 80°C (-22°F to 176°F)
Humidity 95%, non-condensing (Operating and Storage)
Protection IP67 (with appropriate lens cover properly installed).
Shock (Shipping and Storage) 80 G Shock with 150 gram lens attached per IEC 68-2-27.
Vibration (Shipping and Storage) 10 G from 10-500 Hz with 150 gram lens per IEC 68-2-6.
5603, 5600 and 5605 Vision System
Specifications
Specification 5603/5613 5600/5610 5605/5615
Operating Temperature (non-
circulating air)
0°C to 45°C (32°F to 113°F)
1
Operating Temperature (circulating
air)
0°C to 50°C (32°F to
122°F)
2
0°C to 50°C (32°F to
122°F)
3
0°C to 50°C (32°F to
122°F)
4
Storage Temperature -30°C to 80°C (-22°F to 176°F)
Humidity 95%, non-condensing (Operating and Storage)
Protection IP67 (with appropriate lens cover properly installed).
Shock (Shipping and Storage) 80 G Shock with 150 gram lens attached per IEC 68-2-27.
Vibration (Shipping and Storage) 10 G from 10-500 Hz with 150 gram lens per IEC 68-2-6.
1
The vision system should be mounted with sufficient clearance on allsides to allow air circulation around and through the cooling posts
on the blackheat sink.
2
Additionalcooling from a fan is recommended foroperation above 40°C. Foroperation up to 50°C, there must be ≥16 CFM of air
moving through the cooling postson the black heat sink.
3
Additionalcooling from a fan is recommended foroperation above 40°C. Foroperation up to 50°C, there must be ≥4 CFM of air
moving through the cooling postson the black heat sink.
4
Additionalcooling from a fan is recommended foroperation above 40°C. Foroperation up to 50°C, there must be ≥16 CFM of air
moving through the cooling postson the black heat sink.
9