Asustor FLASHSTOR 12 Pro (FS6712X), FLASHSTOR 6 (FS6706T) Quick Installation Guide

  • ASUSTOR FS6706TとFS6712Xのクイックインストールガイドの内容を理解しました。これらのNASデバイスの初期設定、ハードウェア(M.2 SSDなど)の取り付け方法、ソフトウェアインストール方法、そしてトラブルシューティングに関する質問にお答えできます。お気軽にご質問ください。
  • ASUSTOR Control CenterでNASを検出できない場合、どうすれば良いですか?
    NASの電源を切るにはどうすれば良いですか?
    M.2 SSDを取り付ける際に必要なツールは何ですか?
クイックインストールガイド
対応機種
FS6706T / FS6712X
Ver.2.3.0903 (2015-3-2)
Ver. 4.2.0307(2023-3-7)
2
目次
Notices ..................................................................................................................................................... 3
Safety Precautions ................................................................................................................................... 4
1. 同梱されているもの ......................................................................................................................... 5
2. 別売りのアクセサリ ......................................................................................................................... 6
3. ハードウェア取り付けガイド ......................................................................................................... 7
M.2 SSD の取り付けに必要なツール ...................................................................................... 7
M.2 SSD のインストール ........................................................................................................ 7
電源コードを固定する ........................................................................................................... 12
NAS を接続し電源を入れる .................................................................................................. 13
システムメモリのアップグレード ........................................................................................ 13
4. ソフトウェアのインストールガイド ............................................................................................ 18
ダウンロードセンターのインストール ................................................................................. 18
Web インストール ................................................................................................................. 20
モバイル機器を使ってのインストール ................................................................................. 21
5. 付録 .................................................................................................................................................... 24
LED インジケータ.................................................................................................................. 24
背面パネル ............................................................................................................................. 25
NAS をシャットダウンする .................................................................................................. 27
(任意手順) M.2 SSD ヒートシンク (別売) を取り付ける。 .................................................. 28
トラブルシューティング ....................................................................................................... 28
3
Notices
Federal Communications Commission Statement
This device complies with FCC Rules Part 15. Operation is subject to the following two conditions:
This device may not cause harmful interference.
This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the
Federal Communications Commission (FCC) rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority
to operate the equipment.
CE Mark Warning
CE marking for devices without wireless LAN/Bluetooth
The shipped version of this device complies with the requirements of the EEC directives 2004/108/EC "Electromagnetic
compatibility" and IEC60950-1:2005 (2nd Edition)+A1:2009 "Information technology equipment-Safety ".”
The Adopted Trademarks HDMI, HDMI High-Definition Multimedia Interface,
HDMI trade dress and the HDMI Logos are trademarks or registered
trademarks of HDMI Licensing Administrator, Inc. in the United States and
other countries.
4
Safety Precautions
The following safety precautions will increase the life of the NAS. Follow all precautions and instructions.
Electrical Safety
Unplug this product from the power source before cleaning.
Use only the bundled power adapter. Using other power adapters may damage your device.
Ensure that you plug the power adapter to the correct power input rating. Check the label on the power adapter for the
power rating.
Operation Safety
DO NOT place this product in a location where it may get wet.
Place this product on a flat and stable surface.
Use this product in environments with an ambient temperature between 0°C and 40°C.
DO NOT block the air vents on the case of this product. Always provide proper ventilation for this product.
DO NOT insert any object or spill liquid into the air vents. If you encounter technical problems with this product,
contact a qualified service technician or your retailer. DO NOT attempt to repair this product yourself.
DO NOT throw this product in municipal waste.
This product has been designed to enable proper reuse of parts and recycling. This
symbol of the crossed out wheeled bin indicates that the product (electrical and
electronic equipment) should not be placed in municipal waste. Check local regulations
for disposal of electronic products.
5
1. 同梱されているもの
対応機種: FS6706T, FS6712X
NAS デバイス
FS6706T
電源コード
x1
アダプタ
x1
RJ45 ネットワークケーブ
x2
電源コードブラケット
x1
クイックインストールガ
イド
x1
6
2. 別売りのアクセサリ
以下の部品は最寄りの販売店と ASUSTOR Accessories Store (http://shop.asustor.com) から購入できます。
7
3. ハードウェア取り付けガイド
NAS の初期化や容量の作成時に、インストールされた M.2 SSD に保存されているデータはすべて削除され、復
元することができなくなります。期化する前に、M.2 SSD 上のデータが最初にバックアップされていること
を確認してください。
M.2 SSD の取り付けに必要なツール
プラスドライバー
2280 NVMe M.2 SSD 1台以上搭載しています。対応する M.2 SSD の一覧はこちらをご覧ください。
M.2 SSD のインストール
スロット 16への SSD の取り付け - FS6706T および FS6712X
1. 装着された M.2 スロット SSD には連番が振られています
2. プラスドライバーを使用して、底面のカバーのネジを外します。
8
3. カバーを NAS から離すようにスライドさせ、離すときに持ち上げます。
4. M-key M.2 SSD をスロットの M-key ノッチに合わせ、45°の角度で挿入します。
5. SSD を挿入したら、SSD ロックレバーを押しながら、SSD がマザーボードと同じ高さになるように押し下
げ、SSD を固定します。SSD が完全に同じ高さになったら、レバーを放して SSD を固定します。ヒートシ
ンクが必要な場合は、今すぐ取り付ける必要があります。
9
6. カバーを NAS に向かってスライドさせて元の位置に戻します。
7. ネジの元に戻すには、プラスドライバーを使用します。
スロット 712 への SSD の取り付け - FS6712X のみ
1. NVMe SSD 用の M.2 スロットには、下図のように 112 までの連番が振られています。これらの手順に従
ってください。
10
2. プラスドライバーを使用して、トップカバーのネジを外します。
3. 矢印の方向にカバーを外してください。
4. M-key M.2 SSD をスロットの M-key ノッチに合わせ、45°の角度で挿入します。
11
5. SSD を挿入したら、SSD ロックレバーを押しながら、SSD がマザーボードと同じ高さになるように押し下
げ、SSD を固定します。SSD が完全に同じ高さになったら、レバーを放して SSD を固定します。ヒートシ
ンクが必要な場合は、今すぐ取り付ける必要があります。
6. カバーを NAS に向かってスライドさせて元の位置に戻します。
7. プラスドライバーを使って、トップカバーのネジを締めます。
12
電源コードを固定する
注意: NAS の移動中に NAS の電源コードが外れないか心配であれば、同梱のコードブラケットを利用して電源
コードを固定できます。
1. コードブラケットを付属品ボックスから取り出してください。
2. 電源コードのケーブルタイをケーブルタイ用ソケットに挿入します。
3. ケーブルタイを AC アダプターのコードに固定します。
4. バックルを矢印の方向に締め付けます。
13
NAS を接続し電源を入れる
1. NAS を電源装置に接続します。
2. イーサネットケーブルを使用して、ルータ、スイッチまたはハブに NAS を接続します。
3. 右側にある電源ボタンを押します。
4. 青色の電源インジケータライトが点灯している場合、NAS の電源が入ったことを意味します。起動すると、
緑色のシステム・インジケータ・ライトが点滅し、ネットワークに接続されている場合はネットワーク・
インジケータ・ライトが点灯します。NAS が正常に起動すると、緑のシステム・インジケータ・ライトの点
滅が停止します。詳細については、付録のライト・インジケータ・テーブルを参照してください。
システムメモリのアップグレード
ご利用上の注意
FS67 シリーズの NAS デバイスはすべて最大 16GB のメモリをサポートしています。 メモリ モジュールの取り付
けまたは取り外しを行う前に、以下の注意事項をよくお読みください。
お使いの NAS およびメモリ モジュールは、高精度の部品と電子コネクタ テクノロジを採用しています。
お使いの製品の保証期間内に保証が無効になることを避けるために、以下を推奨します。
FS67シリーズのデバイス用のメモリは、ローカルディーラーまたはオンライン ASUSTOR アクセサリ
ーストア(http://shop.asustor.com)から購入することができる。
コンピューター上のメモリのアップグレードに詳しくない場合は、ご自分でメモリ モジュールを取
り付けないでください。
コネクタに触ったり、メモリ モジュール コンパートメント カバーを開けたりしないでください。
ご自分でメモリ モジュールの取り付けまたは取り外しを行うと、スロットやモジュールの破損または誤
った接続により、NAS の故障や事故が発生する可能性があります。この場合、修理は有料となります。
メモリ モジュール、内部の部品、NAS の回路基板の先端で手や指を怪我しないようにご注意ください。
ASUSTOR は、お使いの NAS でサードパーティ製のメモリ モジュールが動作することを保証しません。
14
メモリ モジュールの取り付けまたは取り外しを行う前に、NAS と周辺機器の電源を切り、すべての接続
機器と接続ケーブルを抜いてください。
メモリ モジュールに対する静電気放電による損傷を防ぐために、以下の手順に従ってください。
カーペットの上など、静電気が発生しやすい場所で作業しないでください。
メモリ モジュールの取り付けまたは取り外しを行う前に、NAS 以外の外部の金属物体に触れて静電
気を取り除いてください。NAS 内部の金属部品には触らないでください。
メモリ モジュールをスロットに挿入するときに、向きを間違えないでください。モジュールまたはスロ
ットが損傷したり、回路基板に火がついたりすることがあります。
ねじの大きさに合うドライバーを使用してください。
取り外すように指示されていないねじを取り外したり緩めたりしないでください。
必要な部品と工具
プラス ドライバー
カバーの取り外し
1. ADM ユーザー メニューから [シャットダウン] を選択して NAS をシャットダウンします。
15
2. 電源コードを含め、NAS に接続されているすべてのケーブルとデバイスを抜きます。
FS6706T
FS6712X
3. 図に示されるように、NAS の背面にある 3 つのねじをドライバーで緩めます。
FS6706T
FS6712X
4. 両手で両側からカバーを握り、やさしく押しながら後ろに引き、シャーシから取り外します。
16
メモリーの装着
1. NAS を開くと、NAS の左側のマザーボードに RAM スロットがあります。RAM とスロットのノッチを合わ
せながら、RAM 45°の角度でスロットに挿入します。
2. 両方のラッチがカッチとなるまで、RAM をゆっくり押し下げます。
カバーを元に戻す
1. カバーを元に戻して、前の手順で取り外した 3 つのねじを締めます。
FS6706T
FS6712X
17
2. 電源コードを含むすべてのケーブルを再接続して、NAS を起動します。
FS6706T
FS6712X
18
4. ソフトウェアのインストールガイド
次の 3種類の異なるインストール方法から選択することができます。ASUSTOR Web サイト
(http://www.asustor.com/service/downloads) のダウンロード セクションで、最新のソフトウェアをダウンロード
することができます。
ダウンロードセンターのインストール
Windows ユーザー
1. ASUSTOR コントロールセンターがインストールされたら、ASUSTOR NAS デバイスを探してネットワークス
キャンが自動的に開始されます。
19
2. リストから NAS を選択し、インストールウィザードの指示に従って構成プロセスを完了します。
Mac ユーザー
1. ASUSTOR コントロールセンターがインストールされたら、ASUSTOR NAS デバイスを探してネットワーク
スキャンが自動的に開始されます。
20
2. リストから NAS を選択し、インストールウィザードの指示に従って構成プロセスを完了します。
Web インストール
1. NAS の現在の IP アドレスがすでに分かっている場合、Web ブラウザを開き、NAS IP アドレス(例え
ば、 http://192.168.1.168:8000)を入力して初期化を開始します。
2. インストールウィザードの指示に従って、構成プロセスを完了してください。
/