SICK GTE6L 取扱説明書

  • SICK GTE6L 小型光電センサの操作説明書の内容を確認しました。このセンサの機能、使用方法、トラブルシューティングなどについてご質問にお答えします。例えば、感度調整方法、LED表示の意味、設置方法など、お気軽にご質問ください。
  • 黄色LEDが点灯しないのはなぜですか?
    黄色LEDが点滅するのはどういう意味ですか?
    感度(検出範囲)の調整方法は?
    センサの設置方法は?
    廃棄方法は?
O P E R A T I N G I N S T R U C T I O N
GTE6L
Miniature photoelectric sensors
O P E R A T I N G I N S T R U C T I O N
GTE6L
Miniature photoelectric sensors
de
en
es
fr
it
ja
ko
pt
ru
zh
Described product
G6L
GTE6L
Manufacturer
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Germany
Production location
SICK Malaysia
Legal information
This work is protected by copyright. Any rights derived from the copyright shall be
reserved for SICK AG. Reproduction of this document or parts of this document is
only permissible within the limits of the legal determination of Copyright Law. Any modi‐
fication, abridgment or translation of this document is prohibited without the express
written permission of SICK AG.
The trademarks stated in this document are the property of their respective owner.
© SICK AG. All rights reserved.
Original document
This document is an original document of SICK AG.
Laser
1
2006/42/EC
NO
SAFETY
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
3
Contents
1 General safety notes......................................................................... 5
2 Notes on UL approval........................................................................ 5
3 Intended use...................................................................................... 5
4 Operating and status indicators...................................................... 6
5 Mounting............................................................................................. 6
6 Electrical installation........................................................................ 7
7 Commissioning.................................................................................. 9
7.1 Alignment.................................................................................................. 9
7.2 Sensing range........................................................................................... 9
7.3 Settings..................................................................................................... 10
8 Troubleshooting................................................................................. 11
9 Disassembly and disposal............................................................... 11
10 Maintenance...................................................................................... 12
11 Technical specifications................................................................... 13
11.1 Dimensional drawing................................................................................ 14
11.2 Light spot diagram.................................................................................... 14
CONTENTS
4
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
1 General safety notes
Read the operating instructions before commissioning.
Connection, mounting, and configuration may only be performed by trained
specialists.
2006/42/EC
NO
SAFETY
Not a safety component in accordance with the EU Machinery Directive.
Do not install the sensor at locations that are exposed to direct sunlight
or other weather influences, unless this is expressly permitted in the operating
instructions.
When commissioning, protect the device from moisture and contamination.
These operating instructions contain information required during the life cycle of
the sensor.
EN/IEC 60825-1:2014
IEC60825-1:2007
LASER CLASS 1
Laser
1
Maximum pulse power < 5.95 mW
Puls length: 2 µs
Wavelength: 670 - 690 nm
Complies with FDA performance
standards except for conformance with
IEC 60825-1 Ed. 3,
as described in Laser Notice No. 56,
dated May 8, 2019
ATTENTION
WARNING: Interruption, manipulation or incorrect use can lead to hazardous exposure
due to laser radiation.
2 Notes on UL approval
The device shall be supplied from an isolating transformer having a secondary overcur‐
rent protective device that complies with UL 248 to be installed in the field rated either:
a) max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b) 100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1
3 Intended use
The GTE6L is an opto-electronic photoelectric proximity sensor (referred to as “sensor”
in the following) for the optical, non-contact detection of objects. If the product is used
for any other purpose or modified in any way, any warranty claim against SICK AG shall
become void.
GENERAL SAFETY NOTES 1
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
5
4 Operating and status indicators
Energetic photoelectric proximity sensor.
GTE6L-xxx1x
1
2 3
23
1
1
Potentiometer: sensitivity adjustment
2
LED indicator yellow: status of received light beam
3
LED indicator green: supply voltage active
GTE6L-xxx3x
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
2 3
23
5 Mounting
Mount the sensor using a suitable mounting bracket (see the SICK range of accesso‐
ries).
Note the preferred orientation of the sensor relative to the direction of object motion,
refer to figure 1.
4 OPERATING AND STATUS INDICATORS
6
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
Figure 1: Sensor orientation relative to object direction
6 Electrical installation
The sensors must be connected in a voltage-free state (U
V
= 0 V). The following informa‐
tion must be observed depending on the connection type:
Plug connection: pin assignment
Cable: wire color
Only apply voltage/switch on the voltage supply (U
V
> 0 V) once all electrical connec‐
tions have been established.
Explanation of connection terminology:
BN = Brown
WH = White
BU = Blue
BK = Black
n. c. = no connection
Q = switching output 1
Q = switching output 2
L+ = supply voltage (Uv)
M = common
L.ON = light operate
D.ON = dark operate
ELECTRICAL INSTALLATION 6
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
7
Connection and Output detail:
Table 1: DC
GTE6L -P1xxx
-N1xxx
-E2xxx
-F2xxx
-P3xxx
-N3xxx
-P5xxx
-N5xxx
-P4xxx
-N4xxx
-P6xxx
-N6xxx
-P7xxx
-N7xxx
-E4xxx
-F4xxx
-E6xxx
-F6xxx
-E7xxx
-F7xxx
1 = BN + (L+) + (L+) + (L+) + (L+) + (L+)
2 = WH -
Q
- n. c.
Q
3 = BU - (M) - (M) - (M) - (M) - (M)
4 = BK Q Q Q Q Q
0.205 mm
2
/
AWG24
0.205 mm
2
/
AWG24
1
4
3
2
1
4
3
2
1
4
3
Table 2: Output function
GTE6L
-Px1xx
-Px2xx
-Px3xx
-Px4xx
L.ON, PNP: Q ( 100 mA)
+ (L+)
Q
‒ (M)
Load
+ (L+)
Q
‒ (M)
Load
-Px1xx
-Px2xx
-Px5xx
-Px6xx
D.ON, PNP: Q ( 100 mA)
+ (L+)
Q
‒ (M)
Load
+ (L+)
Q
‒ (M)
Load
-Nx1xx
-Nx2xx
-Nx3xx
Nx4xx
L.ON, NPN Open Collector Q ( 100 mA)
+ (L+)
Q
‒ (M)
Load
+ (L+)
Q
‒ (M)
+ (L+)
Q
‒ (M)
Load
-Nx1xx
-Nx2xx
-Nx5xx
-Nx6xx
D.ON, NPN Open Collector Q ( 100 mA)
+ (L+)
Q
‒ (M)
+ (L+)
Q
‒ (M)
Load
+ (L+)
Q
‒ (M)
Load
6 ELECTRICAL INSTALLATION
8
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
7 Commissioning
7.1 Alignment
Align sensor on object. Select the position so that the red emitted light beam hits the
center of the object. You must ensure that the optical opening (front screen) of the
sensor is completely clear [see figure 2].
Figure 2: Alignment
7.2 Sensing range
Check the application conditions: Adjust the mounting position to ensure the sensing
range and the remission capability correspond to the respective diagram [see see
figure 3]. (x = sensing range, y = operating reserve).
During this process, an object can only be detected in front of a background if the
remission capability of the object is significantly higher than that of the background or if
the distance between the object and the background is sufficiently long.
Figure 3: GTE6L
COMMISSIONING 7
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
9
0
1
2
3
500
(19.69)
400
(15.75)
300
(11.81)
200
(7.87)
100
(3.94)
25/30
200 25017/20
400 4500/5
100/130
Distance in mm (inch)
D
A
B
C
Figure 4: GTE6L
1
Sensing range on black, 6% remission
2
Sensing range on gray, 18% remission
3
Sensing range on white, 90% remission
A Sensing range min. in mm
B Sensing range max. in mm
C Visibility range
D Adjustable switching threshold for foreground suppression
blue Recommended sensing range for the best performance
7.3 Settings
Sensing range setting
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
The sensitivity (sensing range) is adjusted with the potentiometer (type: 5-turn). Clock‐
wise rotation: sensitivity (sensing range) increased; counterclockwise rotation: sensitiv‐
ity (sensing range) reduced. We recommend placing the object within the sensing
range, e.g. see figure 3. Once the sensitivity is set, remove the object from the beam
path. The switching output changes.
Table 3: Adjustment sensing range
The sensor is adjusted and ready for operation.
7
COMMISSIONING
10
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
8 Troubleshooting
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 4: Troubleshooting
LED indicator/fault pattern Cause Measures
Yellow LED does not light up
even though the light beam is
aligned to the object and the
object is within the set sensing
range
No voltage or voltage below
the limit values
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Voltage interruptions Ensure there is a stable power
supply without interruptions
Sensor is faulty If the power supply is OK,
replace the sensor
Yellow LED flashes Sensor is still ready for oper‐
ation, but the operating condi‐
tions are not ideal
Check the operating condi‐
tions: Fully align the beam
of light (light spot) with the
object / Clean the optical sur‐
faces / Check sensing range
and adjust if necessary
Yellow LED lights up, no object
in the path of the beam
Excessive background remis‐
sion
Check changes to the back‐
ground. Reduce the sensitivity
of the sensor or use sensors
with background suppression
Object is in the path of the
beam, yellow LED does not
light up
Sensitivity is set too low or dis‐
tance between the sensor and
the object is too long
Increase the sensing range,
take note of the distance
between the sensor and the
background
Object is in the path of the
beam, yellow LED does not
light up
Remission capability of the
object is insufficient
Increase the sensing range,
take note of the distance
between the sensor and the
background
9 Disassembly and disposal
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE: This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
TROUBLESHOOTING 8
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
11
10 Maintenance
SICK sensors are maintenance-free.
We recommend doing the following regularly:
Clean the external lens surfaces
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
10 MAINTENANCE
12
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
11 Technical specifications
GTE6L
Laser class 1
Sensing range 5 ... 400 mm
Sensing range max. 0 ... 450 mm
1)
Light spot diameter/distance 0.4 mm / 150 mm
Supply voltage U
B
DC 10 ... 30 V
2)
Output current I
max.
100 mA
3)
Switching frequency 1,000 Hz
4)
Max. response time 0.625 ms
5)
Enclosure rating IP67
Protection class III
Circuit protection A, C, D
6)
Ambient operating temperature -20 ... +50 °C
7)
1)
Object with 90 % remission (based on standard white DIN 5033)
2)
Limit values. U
B
connections reverse-polarity protected. Residual ripple max 5 V
PP
3)
As of U
B
> 24 V, a max. load current I
max.
= 50 mA is permitted.
4)
With light / dark ratio 1:1
5)
Signal transit time with resistive load
6)
A = U
B
-connections reverse polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
7)
As of T
a
45 °C, a max. supply voltage U
B
= 24 V and a max. load current I
max.
= 50 mA is permitted.
TECHNICAL SPECIFICATIONS 11
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
13
11.1 Dimensional drawing
10.2 (0.4)
6.9 (0.27)
0.5
(0.02)
21
(0.83)
0.5
(0.02)
9.7
(0.38)
3
(0.12)
11.5
(0.45)
31.5 (1.24)
28.5 (1.12)
25.4 (1.00)
2.3
(0.09)
18.3
(0.72)
305 (12.01)
9.7
(0.38)
12
(0.47)
1
2
4
4
3
Figure 5: Dimensional drawing
1
Center of optical axis, sender
2
Center of optical axis, receiver
3
Operating and status indicators
4
M3 threaded mounting hole
11.2 Light spot diagram
Sensor
Ø 0.4
(0.02)
Ø 2.2
(0.09)
Ø 1.8
(0.07)
Ø 6.0
(0.24)
Distance in mm (inch)
Diameter in mm (inch)
25
(0.98)
150
(5.91)
250
(9.84)
450
(17.72)
11 TECHNICAL SPECIFICATIONS
14
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
B E T R I E B S A N L E I T U N G
GTE6L
Miniatur-Lichtschranke
de
en
es
fr
it
ja
ko
pt
ru
zh
Beschriebenes Produkt
G6L
GTE6L
Hersteller
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Deutschland
Fertigungsstandort
SICK Malaysia
Rechtliche Hinweise
Dieses Werk ist urheberrechtlich geschützt. Die dadurch begründeten Rechte bleiben
bei der Firma SICK AG. Die Vervielfältigung des Werks oder von Teilen dieses Werks
ist nur in den Grenzen der gesetzlichen Bestimmungen des Urheberrechtsgesetzes
zulässig. Jede Änderung, Kürzung oder Übersetzung des Werks ohne ausdrückliche
schriftliche Zustimmung der Firma SICK AG ist untersagt.
Die in diesem Dokument genannten Marken sind Eigentum ihrer jeweiligen Inhaber.
© SICK AG. Alle Rechte vorbehalten.
Originaldokument
Dieses Dokument ist ein Originaldokument der SICK AG.
Laser
1
2006/42/EC
NO
SAFETY
16
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
Inhalt
12 Allgemeine Sicherheitshinweise..................................................... 18
13 Hinweise zur UL Zulassung.............................................................. 18
14 Bestimmungsgemäße Verwendung............................................... 19
15 Betriebs- und Statusanzeigen.......................................................... 19
16 Montage.............................................................................................. 19
17 Elektrische Installation..................................................................... 20
18 Inbetriebnahme................................................................................. 22
18.1 Ausrichtung............................................................................................... 22
18.2 Schaltabstand........................................................................................... 22
18.3 Einstellungen............................................................................................. 23
19 Störungsbehebung............................................................................ 24
20 Demontage und Entsorgung............................................................ 24
21 Wartung.............................................................................................. 25
22 Technische Daten.............................................................................. 26
22.1 Maßzeichnung........................................................................................... 27
22.2 Lichtfleckdiagramm.................................................................................. 27
INHALT
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
17
12 Allgemeine Sicherheitshinweise
Lesen Sie vor der Inbetriebnahme des Geräts die Betriebsanleitung.
Der Anschluss, die Montage und die Konfiguration des Geräts dürfen nur
von geschultem Fachpersonal vorgenommen werden.
2006/42/EC
NO
SAFETY
Bei diesem Gerät handelt es sich um kein sicherheitsgerichtetes Bauteil im
Sinne der EU-Maschinenrichtlinie.
Installieren Sie den Sensor nicht an Orten, die direkter Sonneneinstrahlung
oder sonstigen Wettereinflüssen ausgesetzt sind, ausser dies ist in der Betriebs‐
anleitung ausdrücklich erlaubt.
Bei der Inbetriebnahme ist das Gerät ausreichend vor Feuchtigkeit und Verschmut‐
zung zu schützen.
Die vorliegende Betriebsanleitung enthält Informationen, die während des Lebens‐
zyklus der Lichtschranke benötigt werden.
EN/IEC 60825-1:2014
IEC60825-1:2007
LASERKLASSE 1
Laser
1
Maximale Pulsleistung: < 5,95 mW
Impulsdauer: 2 µs
Wellenlänge: 670 - 690 nm
Entspricht den FDA
Leistungsstandards mit Ausnahme der
Konformität mit IEC 60825-1, Ed. 3
wie im Laserhinweis Nr. 56 vom
08.05.2019 beschrieben
ACHTUNG
WARNUNG: Eingriffe, Manipulation oder eine unsachgemäße Verwendung können zu
gefährlicher Exposition gegenüber Laserstrahlung führen.
13 Hinweise zur UL Zulassung
The device shall be supplied from an isolating transformer having a secondary overcur‐
rent protective device that complies with UL 248 to be installed in the field rated either:
a) max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b) 100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1
12 ALLGEMEINE SICHERHEITSHINWEISE
18
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
14 Bestimmungsgemäße Verwendung
Die GTE6L ist ein optoelektronischer Reflexions-Lichttaster (im Folgenden Sensor
genannt) und wird zum optischen, berührungslosen Erfassen von Sachen eingesetzt.
Bei jeder anderen Verwendung und bei Veränderungen am Produkt verfällt jeglicher
Gewährleistungsanspruch gegenüber der SICK AG.
15 Betriebs- und Statusanzeigen
Energetischer Reflexions-Lichttaster.
GTE6L-xxx1x
1
2 3
23
1
1
Potentiometer: Einstellung der Empfindlichkeit
2
Anzeige-LED gelb: Status Lichtempfang
3
Anzeige-LED grün: Versorgungsspannung aktiv
GTE6L-xxx3x
Sensor ohne Einstellmöglichkeit: Sensor ist eingestellt und betriebsbereit.
2 3
23
16 Montage
Den Sensor unter Verwendung eines geeigneten Befestigungswinkels montieren (siehe
SICK-Zubehörpalette).
Bevorzugte Ausrichtung der Lichtschranke relativ zur Bewegungsrichtung des Objekts
beachten, siehe Abbildung 6.
BESTIMMUNGSGEMÄE VERWENDUNG 14
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
19
Abbildung 6: Ausrichtung der Lichtschranke relativ zur Objektrichtung
17 Elektrische Installation
Anschluss der Sensoren muss spannungsfrei (U
V
= 0 V) erfolgen. Je nach Anschlussart
sind die folgenden Informationen zu beachten:
Steckeranschluss: Anschlussbelegung
Leitung: Aderfarbe
Erst nach Anschluss aller elektrischen Verbindungen die Spannungsversorgung (U
V
> 0 V) anlegen bzw. einschalten.
Erläuterung der Anschlussterminologie:
BN = braun
WH = weiß
BU = blau
BK = schwarz
n. c. = unbeschaltet
Q = Schaltausgang 1
Q = Schaltausgang 2
L+ = Versorgungsspannung (Uv)
M = gemeinsam
L.ON = Hellauswertung
D.ON = Dunkelauswertung
17 ELEKTRISCHE INSTALLATION
20
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
/