The Power LED should be lit when the power system is working normally. If the
Power LED is not lit, please check as follows:
A1:
Make sure the AC power cord is connected to the switch with power source
properly.
A2:
Make sure the voltage of the power supply meets the requirements of the
input voltage of the switch.
A3:
Make sure the power source is ON.
Standard
IEEE802.3i, IEEE802.3u, IEEE802.3ab,
IEEE802.3ad, IEEE802.3af, IEEE802.3x,
IEEE802.1p, IEEE802.1q, IEEE802.1d,
IEEE802.1s, IEEE802.1w, IEEE802.3z
CSMA/CD
Ethernet:10Mbps (Half Duplex) 20Mbps (Full Duplex)
Fast Ethernet: 100Mbps (Half Duplex) 200Mbps (Full Duplex)
Gigabit Ethernet: 2000Mbps (Full Duplex)
10Base-T:
UTP Cat. 3, 4, 5 cable (maximum 100m) EIA/TIA-568 100
STP (maximum 100m)
100Base-TX:
UTP of Cat. 5 or above (maximum 100m)
EIA/TIA-568 100 STP (maximum 100m)
1000Base-T:
UTP of Cat. 5e or above (maximum 100m)
EIA/TIA-568 100 STP (maximum 100m)
8 10/100/1000Mbps Auto-Negotiation RJ45 ports and 2
SFP slots
PoE Ports: Port1-Port8
Total Power Supply: 53W
Power, System, Link/Act, PoE MAX, PoE Status, SFP1, SFP2
Store and Forward
Automatically learning, automatically aging
10Base-T: 14881pps/Port
100Base-Tx: 148810pps/Port
1000Base-T: 1488095pps/Port
10Base-T: 14881pps/Port
100Base-Tx: 148810pps/Port
1000Base-T: 1488095pps/Port
Protocol
Data Transfer Rate
Network Media (Cable)
Number of Ports
LED Indicators
Transfer Method
MAC Address Learning
Frame Filter Rate
Environmental and Physical Specications
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
0˚C to 40˚C (32˚F to 104˚F)
-40˚C to 70˚C (-40˚F to 158˚F)
10% to 90% non-condensing
5% to 90% non-condensing
Frame Forward Rate
PoE Ports (RJ45)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired
operation.
Any changes or modications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
FCC STATEMENT
Do not use this product near water,
for example, in a wet basement or
near a swimming pool.
Avoid using this product during an
electrical storm. There may be a
remote risk of electric shock from
lightning.
SAFETY NOTICES
Cautions
This is a class A product. In a domestic
environment, this product may cause radio
interference, in which case the user may
be required to take adequate measures.
CE Mark Warning
© 2017 TP-Link
Industry Canada Statement
CAN ICES-3 (A)/NMB-3(A)
Explanation of the symbols on the product label
DC voltage
RECYCLING
This product bears the selective sorting symbol for Waste electrical and electronic equipment
(WEEE). This means that this product must be handled pursuant to European directive
2012/19/EU in order to be recycled or dismantled to minimize its impact on the environment.
User has the choice to give his product to a competent recycling organization or to the retailer
when he buys a new electrical or electronic equipment
General Specications
Frequently Asked Questions (FAQ)
Q1. The Power LED is not lit.
Please try the following:
A1:
Make sure that the cable connectors are rmly plugged into the switch and
the device.
A2:
Make sure the connected device is turned on and works normally.
A3: Try to change the connected device’s transmission speed and duplex mode.
A4:
The cable must be less than 100 meters long (328 feet).
Q2. Why is the Link/Act LED not lit while a device is connected to
the corresponding port?
Q3. Why are some ports not supplying power for PoE devices?
Please try the following:
A1: Make sure that this PoE device complies with IEEE 802.3af/IEEE 802.3at.
A2: Try another PoE port on the switch.
A3: Pay attention to PoE priority. If the total power consumption of PoE powered
devices exceeds 53W, a priority will be set among the ports. Ports with a smaller
port number will have higher priority. For example, Port 1, 2 and 5 are each
consuming 15.4W. If an additional powered device consuming 12W is connected
to Port 3, then the switch will cut o power to Port 5 because of the overload.
Specications
Продукт сертифіковано згідно с
правилами системи УкрСЕПРО
на відповідність вимогам
нормативних документів та
вимогам, що передбачені
чинними законодавчими актами
України.
BSMI Notice
For technical support and other information, please visit
http://www.tp-link.com/support
この装置は、クラスA情報技術装置です。この装置を家庭環境で使用すると電波妨害を引き起こすことがあり
ます。この場合には使用者が適切な対策を講ずるよう要求されることがあります。 VCCI-A