Siruba LF375-FA-LFA-LFR Instruction book

タイプ
Instruction book
FA/LFA/LFR
30 W
1φAC110V±15% 50/60Hz
1φAC220V±15% 50/60Hz
FA-A1
LFA-A1
LFR-A1
FA-A2
LFA-A2
LFR-A2
1.此使AC110V或單相
AC220V
1.Single phase AC110 or AC220V is
applicable to this machine, but if is
connected to the wrong power
voltage or is supplied with the wrong
power, the controller may burn.
AC110V
AC220V
Single-phase AC110V
or AC220V Socket
PS.LFR (LF290-A2/LF290-
A1)
Only LFR is equipped with the tape
attaching wheel(LF290-A2/LF290-A1)
1φAC110V±15% 50/60Hz
1φAC220V±15% 50/60Hz
FA-A1
LFA-A1
LFR-A1
FA-A2
LFA-A2
LFR-A2
送帶操作說明:
/Fig.5
Decrease the
length the tape
Increase the
length the tape
Description of the operation of feeding
the tape
調
電源開關
The adjusting knob of feeding the tape
Power switch
檢查電源開關是否開啟
Check if the power switch.
開啟檢查電源開關
Turn on the power switch.
檢查感應馬達(LF362/FA22Q)電源線,連
(LF360/FA24Q) CON7
點,是否脫落。
Check if the power cord of the sensor
motor(LF362/FA22Q),which is
connected to the contact of the control
board(LF360/FA24Q)CON7,falls off.
構(LF362/FA22Q
LF61Q)
Check if the tape feeding device
(LF362/FA22QLF61Q)is stuck.
檢查控制板(LF360/FA24Q)CON1
PIN1,2DC5V
Check if the control board
(LF360/FA24Q) CON1 PIN1,2 has
DC5V voltage.
更換控制板(LF360/FA24Q)
Replace the control board(LF360/FA24Q)
更換電源供應器(LF363)
Replace the power supplier (LF363)
1.送帶馬達無動作: 1.Tape feeding motor doesnt work
線(LF263LF262)
接在控制板(LF360/FA24Q)CON8,CON9
接點是否脫落。
Check if the sensor signal wire(LF263
LF262),which is connected to the control
board(LF360/FA24Q)CON8,CON9,falls
off.
檢查送帶拉桿(LF60K-7/FA14K)是否卡
Check if the pull rod of the tape
feeding(LF60K-7/FA14K)is stuck.
檢查控制板(LF360/FA24Q)CON1
PIN1,2DV5V
Check if the control board
(LF360/FA24Q)CON1 PIN1,2have
DC5V voltage.
板(LF360/FA24Q)
Replace the control board
(LF360/FA24Q)
更換電源供應器(LF363)
Replace the power Supplier(LF363)
2.打帶馬達無動作: 2.Tape attaching motor doesnt work
檢查打帶馬達(LF298)/(LF267)之啟動電
容電源線(LF370),連接在控制板
(LF360/FA24Q) CON5的接點是否脫
Check if the power cord of the start
capacitor (LF370)of the tape attaching
motor(LF298)/(LF267) connected to
the contact of the control board
(LF360/FA24Q) CON5 loosens.
FA/LFA/LFR表 ● FA/LFA/LFR CONVERSION CHART
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30

Siruba LF375-FA-LFA-LFR Instruction book

タイプ
Instruction book

他の言語で