-4- SM-629755-A
6. Cautions on Use
• Please use this unit with an appropriate controller.
• Please operate the cooling fan when this unit is used.
• A thermo-relay is incorporated in this unit, which operates when the discharge resistor temperature reaches
150°C.
• When this relay is actuated, output terminals C1–C2 of the regeneration discharge unit become open.
• Create the sequence so that the controller always stops, when the thermo-relay is actuated.
• Once the thermo-relay is actuated, it takes about three minutes until it is reset (i.e., restored to a normal
state).
• For accident prevention, please attach a terminal stand cover after wiring, and use it.
7. Maintenance
• Please turn off the power supply of equipment for safety when the cooling fan is exchanged.
• Please demand the cooling fan for exchange to our nearest office, agency.
• The method of exchanging the cooling fan.
Please remove fan installation screw (two places) at the main body base and exchange the cooling fan.
When the cooling fan is reinstalled, please pay attention to the direction of the cooling fan and do not
forget to install the fan guard. Also pay enough attention not to sandwich the lead wire.
R E G E N E R A T I O N U N I T
MADE IN JAPAN
M O D E L : A B S U - □ □ □ □
M A T H : □ □ □ □ K g
S E R . N O : □ □ □ □ □ □ □ □ □ □ □
T OS H I B A M A CH I N E C O ., L T D .
Do not touch heatsink when power is ON and for a while
or internal parts.May cause electric shock.
or indirect contact,only RCD of Type B is allowed on the supply side of the Electric Equipment(EE)
Design notice:Where residual-current-operated protective device(RCD)is used for protection in case of direct
電源ON中及びOFFして暫くはヒートシンクに触るな!火傷の恐れあり。
10分間放電するまで端子や内部に触るな!感電の恐れあり。
必ずアース線を接続せよ!
after power turned OFF. May cause burn.
Allow 10 minutes discharge time before access to terminals
Connect the grounding line without fail.
注 意
危 険
注 意
WARNING
CAUTION
CAUTION
Fan installation screw
(two places)