LYVE

Seagate LYVE ユーザーガイド

  • こんにちは!Seagate Lyve Mobile Rackmount Receiver SMAP001のクイックスタートガイドの内容を理解しています。このデバイスの取り付け、電源接続、デバイスの挿入/取り外し、セキュリティ設定などについてご質問がありましたら、お気軽にお尋ねください。このデバイスは、複数のホストインターフェースをサポートし、Lyve Portal IdentityまたはLyve Tokenによるセキュリティ管理を備えています。
  • ラックへの取り付け手順は?
    電源接続方法は?
    デバイスの挿入と取り外し方法は?
    セキュリティ設定方法は?
QUICK START GUIDE
2
Rackmount Kit Parts List
D 10-32 cage nut (4x)
Back rails (2x)
C M4 nut (4x) I Flat washer (4x)
H 10-32 pan head screw (4x)
(#10-32xL25.4, phillips screw)
E 10-32 flat head screw (8x)
(#10-32xL12.7, phillips screw)
F Stepped washer (8x)
J Latch (2x)
K 10-32 nut (2x)
Washer (2x)
Front rail left
L
Front rail right
Zip ties (2x)
A M4 screw for 7.1 mm hole (4x)
(M4xL10 (6.8,2.5), phillips screw)
A B C D E F G H I J K
B M4 scew for 0.375” hole (4x)
(M4xL10 (9.1,2.5), phillips screw)
G M4 flat pan head screw (4x)
(M4xL8 phillips screw)
L
R
3
Lyve Mobile Rackmount Receiver
Receiver weight (empty): 47.52 lb/21.6 kg
Do not attempt to lift or assemble
Lyve Mobile Rackmount Receiver
with compatible devices inserted.
Removing Lyve Mobile Rackmount Receiver from its packaging
and carrying the unit must be performed by at least two people.
CAUTION
TWO-PERSON
LIFT REQUIRED
BACK
FRONT
Back rails (2x)
G M4 flat pan
head screw (4x)
Front rail left
Front rail right
D 10-32 cage nut (4x)
I Flat washer (4x)
H
10-32 pan head
screw (4x)
B M4 Screw for
0.375” hole (4x)
A M4 Screw for
7.1 mm hole (4x)
F Stepped washer (8x)
E 10-32 flat head screw (8x)
C M4 nut (X4)
L
4
1
2
Rack Assembly
Attach M4 rack screws to the front rails
Your rack may have standard 7.1 mm or .375” openings. M4 screws are provided for both hole dimensions.
Insert an M4 screw for 7.1 mm or .375” in the indicated hole on the left front rail and fasten it with an M4 nut.
Repeat the process for the right front rail.
Attach M4 rack screws to the back rails
Insert M4 screws in the indicated holes on the back rails and fasten them with M4 nuts.
BACK
Back rails
A or B
M4 screw for
7.1 mm or
.375” hole
C M4 nut
FRONT
Front rail left
Front rail right
A or B
M4 screw for 7.1 mm
or .375” hole
C M4 nut
L
5
3
Attach cage nuts
Attach two 10-32 cage nuts to each front rack post. Leave 101.6 mm space between the two nuts
on each post.
FRONT
BACK
D 10-32 cage nut
101.6 mm
496.685 mm
804.826 mm
6
4
Attach the front rails to the back rails
Use M4 flat pan head screws to loosely attach the front rails to the back rails.
FRONT
BACK
G M4 flat pan head screw
L
7
5
Attach the rails to the front of the rack
Position the left front rail on the cage nut on the left front rack post. Insert two 10-32 flat head screws
into two stepped washers. Use the screw/washer assemblies to fasten the left front rail to the left
front rack post.
Repeat the process for the right front rail and right front rack post.
FRONT
BACK
Front rail left
Front rail right
F Stepped washer
E 10-32 flat head screw
L
L
8
6
Attach the back rails to the back of the rack
Position the back rails at the correct height on the rear rack posts. Insert two 10-32 flat head screws into
two stepped washers. Use the screw/washer assemblies to fasten the back rails to the rear rack posts.
BACK
F Stepped washer
E 10-32 flat head screw
9
7
Tighten rail attachments
Tighten the M4 flat pan head screws attaching the front and back rails.
FRONT
BACK
G M4 flat pan head screw
L
10
Install Lyve Mobile Rackmount Receiver
8
Receiver weight (empty): 47.52 lb/21.6 kg
Do not attempt to lift or assemble Lyve Mobile Rackmount Receiver with compatible devices inserted.
Removing Lyve Mobile Rackmount Receiver from its packaging
and carrying the unit must be performed by at least two people.
CAUTION
TWO-PERSON
LIFT REQUIRED
Position the front face of Lyve Mobile Rackmount Receiver over the cage nuts attached to the left
and right front posts. Insert two 10-32 pan head screws into two flat washers. Use the screw/washer
assemblies to attach Lyve Mobile Rackmount Receiver to the top cage nuts attached to the left and
right front posts.
Insert two 10-32 screws into the two latches. Use the screw/latch assemblies to attach Lyve Mobile
Rackmount Receiver to the bottom cage nuts attached to the left and right front posts.
FRONT
H 10-32 Pan head
screw
I Flat washer
J Latch
D 10-32
cage nut
D 10-32
cage nut
11
Recommended Clearance
30 cm
FRONT
BACK
J Latch
K 10-32
nut/washer
H 10-32 Pan head screw
If Lyve Mobile Rackmount Receiver is not assembled on a rack, use the additional lock washer and
10-32 hexagonal nut to attach each latch to the enclosure.
Freestanding Latch Assembly
12
Slot B Slot A
Power switch
Host interface
module*
CLI – A*** Host interface
module*
Ethernet – A**
Host interface
module*
CLI – B***
Ethernet – B**
Power input – A Power input – B
Host interface
module*
Slot A/Left Slot A/Right
CLI
Slot B/Left Slot B/Right
CLI
ACT ACT
Views
Front view
Back view
* Data connectors not displayed
** Management via Lyve Client
*** For service only. Not to be used for data transfers.
13
Setup Requirements
Lyve Mobile Security
Lyve Mobile offers two ways for project admins to manage how end users securely access Lyve
Mobile storage devices:
Lyve Portal Identity
End users authorize client computers to access Lyve Mobile devices using their Lyve Management
Portal credentials. Requires an internet connection for initial setup and periodic reauthorization
through Lyve Management Portal.
Lyve Token Security
End users are provided with Lyve Token files that can be installed on certified client computers and
Lyve Mobile Padlock devices. Once configured, computers/Padlock devices unlocking Lyve Mobile
devices do not require continual access to Lyve Management Portal or the internet.
For details on setting up security, go to
www.seagate.com/lyve-security.
Network setup
For details on configuring SAS, fibre channel, and iSCSI data network connectivity, see
www.seagate.com/manuals/rackmount-receiver.
www.seagate.com/support/rackmount-receiver
14
Setup
1
Connect to host interfaces
Lyve Mobile Rackmount Receiver is pre-configured to support one or more of these host interfaces:
FC 16Gb, 2-port SFP+ iSCSI 25Gb, 4-port 10Gb SFP+ SAS 12Gb, 2-Port SFF-8644
FC 32Gb, 2-Port SFP+ iSCSI 10GbaseT, 2-Port RJ45
Connect the appropriate fibre channel, Ethernet, or SAS cables to available ports on Lyve Mobile
Rackmount Receiver’s back panel.
Fibre optic cable
Ethernet cable
SAS cable
15
2
Connect power
Insert the zip tie into the slot below the socket.
Insert the power cord into the socket and secure with the zip tie.
Slot A/Left Slot A/Right
CLI
Slot B/Left
Slot B/Right
CLI
ACT
ACT
Zip ties
Slot A/Left Slot A/Right
CLI
Slot B/Left
Slot B/Right
CLI
ACT
ACT
Slot A/Left Slot A/Right
CLI
Slot B/Left Slot B/Right
CLI
ACT ACT
16
4
Connect compatible devices
Insert compatible devices into slot A or B on Lyve Mobile Rackmount Receiver.
3
Connect Ethernet port
Lyve Client communicates with devices inserted in Lyve Mobile Rackmount Receiver via the Ethernet
management ports. Ensure that the Ethernet management ports are connected to the same network
as the host devices running Lyve Client. If no device is inserted in a slot, theres no need to connect its
corresponding Ethernet management port to the network.
Slot A/Left Slot A/Right
CLI
Slot B/Left Slot B/Right
CLI
ACT
ACT
17
5
Turn on power
Set the power switch on Lyve Mobile Rackmount Receiver to ON.
Slot A/Left Slot A/Right
CLI
Slot B/Left
CLI
ACT
Slide device in until it’s fully inserted and firmly connected to Lyve Mobile Rackmount Receiver’s data
and power. Close latches.
18
6
Unlock the device
The LED on the device inserted in Lyve Mobile Rackmount Receiver blinks white during the boot process
and turns solid orange. The solid orange LED color indicates the device is ready to be unlocked.
Once the device has been unlocked by a valid Lyve Portal Identity or Lyve Token file, the LED on the
device turns solid green. The device is ready for use.
Safely removing a device
Your computer must perform filing and housekeeping operations on your Lyve device before it is physically
removed from Lyve Mobile Rackmount Receiver. To avoid corrupting or damaging files, always eject the
device’s volumes from your computer before physically removing the device.
To avoid muscle strain or back injury, use proper lifting techniques when removing devices from Lyve
Mobile Rackmount Receiver.
LED
19
OOOOOX
OOOOOX
OOOOOX
OOOOOO
Hazardous Substances
有害物质
Part Name (Pb) (Hg) (Cd) (Cr
+6
) (PBB) (PBDE)
󸶜
部件名称 󴄡 󸸡 󱆡󰵰󸷃 󱷣󴓒󶖮󶭌
󱷣󴓒󰳆󶭌󸞋
󱷛󳇚󵘳󵎵󱓆󱋈󵂿󸁠󳢐
Bridge PCBA
󵂿󴒐󼶯󱺞󳢾󳈡󰹡󼶰
Power Supply (if provided)
󳇚󱕿󵂿󶌲󼶯󱺞󳢾󳈡󰹡󼶰
Interface cable (if provided)
󱆮󰴾󱷛󱶡󶋰󰵮
Other enclosure components
󳠘󷚒󳦳󰹥󳅻󽶳󽶳󽶵󽶸󽶶󵌴󷤻󲎌󶍂󱋇
This table is prepared in accordance with the provisions of SJ/T 11364-2014
O: 󷚒󵞑󷵣󳟘󲎻󴯼󷽐󱫈󷵣󸘩󰵮󲾧󳟘󱫱󷽐󳡎󳕣󰱉󵌴󱗢󸠉󱫱󱫈󽶴󽶸󽶷󽶹󽶴󷤻󲎌󵌴󸾀󸠉󷣒󴃴󰵕󰰗
O:
Indicates that the hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement of
GB/T26572.
X: 󷚒󵞑󷵣󳟘󲎻󴯼󷽐󶤙󲑾󱫈󷵣󸘩󰵮󵌴󳤈󰰊󱫱󷽐󳡎󳕣󰱉󵌴󱗢󸠉󷿄󱉵󽶴󽶸󽶷󽶹󽶴󷤻󲎌󵌴󸾀󸠉󷣒󴃴
X:
Indicates that the hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit
requirement of GB/T26572.
China RoHS 2 table
China RoHS 2 refers to the Ministry of Industry and Information Technology Order No. 32, effective July 1, 2016, titled
Management Methods for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products. To
comply with China RoHS 2, we determined this product’s Environmental Protection Use Period (EPUP) to be 20 years in
accordance with the Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products, SJT
11364-2014.
中国 RoHS 2 是指 2016 年 7 月 1 日起施的工业和信息化部令第 32 号电力电子产品限制使有害物质管理办法”为了中国 RoHS 2 的
要求,我们“电子电气产品有害物质限制使标识(SJT 11364-2014) 确定本产品的环保使用期 (EPUP) 为 20 年。
Taiwan RoHS table
Taiwan RoHS refers to the Taiwan Bureau of Standards, Metrology and Inspection’s (BSMI’s) requirements in standard CNS 15663,
Guidance to reduction of the restricted chemical substances in electrical and electronic equipment. Beginning on January 1, 2018,
Seagate products must comply with the “Marking of presence” requirements in Section 5 of CNS 15663. This product is Taiwan
RoHS compliant.
The following table meets the Section 5 “Marking of presence” requirements.
台灣 RoHS 是指台灣標準局計量局 (BSMI) 對標準 CNS 15663 要求的排電子電氣設備用化學物指引。 從2018年1月1日起
Seagate 產品必須符合 CNS 15663 第 5 節「含有標示」要求產品符合台灣 RoHS
下表符合第 5 節含有標示要求
OOOOO
OOOOO
OOOOO
OOOOOO
󸾀󵂬󴯼󷻮󱕘󱆮󱐮󲍅󵭠󷌞
Unit
Restricted Substance and its chemical symbol
(Pb) (Hg) (Cd) (Cr+6) (PBB) (PBDE)
󱠳󱅖
󱷜󳇛󵘳󵏈󱓇󱋈󹃇󸁠󳢏
Bridge PCBA
󹃇󴒐󱺟󳢾󳈡󰹡
Power Supply (if provided)
󱁊󸊙󶄙󳡎󱺟󳢾󳈡󰹡
Interface cable (if provided)
󱆮󰴿󱷜󴀐󵿟󰵮
Other enclosure components
󹌰󲎌󹃇󱵫󹌰󲎌󹃇󴉴󽶳󽶲󽶲󽶴󽶶󽶲󽶻󽶶󽶶󽶹󽶴󽶴󳏫󰷽󴒿󲤳󽶷󽶶󽶲
󱀖󶔔󽶳
O
󰺢󳃙󷪋󹋂󸾀󵂬󴯼󷻮󰱰󵌭󱊉󴁅󱗣󸠉󳠕󷿄󱉵󵌭󱊉󴁅󱗣󸠉󱯺󴒘󰽭󽶫
Note 1. “
O
” indicates that the percentage content of the restricted substance does not exceed the percentage of reference value of presence.
󱀖󶔔󽶴
󰺢󳃙󷪋󹋂󸾀󵂬󴯼󷻮󴢢󳆷󸾞󹋂󵏙󽶫
Note 2. “
” indicates that the restricted substance corresponds to the exemption.
Product Name: Lyve Mobile Rackmount Receiver, Model: SMAP001
󵂤󱛂󱖳󵥓󼷁󵚹󵏈󸾜󱊜󳐺󲓥󱲩󽶭󱭕󷌞󼷁󽶲󽶲󽶳
󸤌 󴄡 󸭾 󱆡󱃏󸥆 󱷢󴓓󶗥󶭍 󱷢󴓓󰳆󶭍󸞌
の装置は、スB機器ですの装置は、住宅環境で使用す目的
ていまこのがラテレビジョン接して使され ると、
信障害を引き起とがあます書に従って正しい取り扱いをて下
VCCIB
FCC DECLARATION OF CONFORMANCE
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
CLASS B
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
CAUTION: Any changes or modifications made to this equipment may void the user’s authority to operate this equipment.
本 設 備 勿 置 於 潮 處。
請將產品於手冊規定的環境使用溫度以避免過熱
連接至電源前請先檢查電壓
當設備不用請將所有電源線拔避免電壓不穩而造成傷害
勿將任何液體濺入設備中避免線路短路
請勿自行調整或修理已通電的設備以確保您的安全
20
/