6
4.Operation Guide
4.1 Readings Hold
During the measuring process, if the readings are required to hold, slightly
touch "Hold/BL" key ,the display value will be locked, slight press "Hold/BL" key
again to cancel readings hold.
4.2 Back Light
1)In the process of measurement, if the ambient light is too dim, causing reading
difficulties, press "Hold/BL" key for about 2s, open Back Light and it will
automatically off after about 1 minute.
2)During the process if press "Hold/BL" key for about 2s, then the Back Light will
be turned off.
4.3 Auto Power Off
1)If after 10 minutes when the meter is on without any operation, it will go into
hibernation and automatically shut down to save power. Before the meter off,
there will be one sound of the buzzer to remind every 1 minute.
2)Press the NCV key after auto power off to wake the meter into working status.
4.4 Measurement Preparations
1)Turn the transfer switch, turn on the power. If the battery voltage is low (of
about ≤2.4V), the LCD will show“ ”symbol, then the battery shall be
replaced.
2)When the meter has not entered into
measurement, it will automatically enter into
the status of automatic scan, the meter
displays as the following diagram shows.
4.5 AC Current Measurement
1) Hold the trigger, open the clamp head and clamp one cable of the measured
circuit.
2) When measured signal >0.05A, the main LCD of the meter displays the
measured current value, the vice LCD displays current frequency (Note: When
the frequency >300Hz, only when current value >0.2A could the meter
displays its frequency value)
3) When measured circuit, slightly touch MAX key, when capture current >0.05A,
the meter displays the maximum current value captured. the meter displays as
the following diagram