TP-LINK MC200CM Quick Installation Guide

タイプ
Quick Installation Guide

このマニュアルも適しています

© 2018 TP-Link 7106508080 REV4.0.1
Gigabit Ethernet Media Converter
Note: MC220L needs to be plugged in with an SFP module to work normally. It is recommended to use a TP-Link SFP module on MC220L, because other vendors’
SFP modules may be incompatible.
LC-SC Fiber Cable
Package Contents: Media Converter, Power Adapter, User Guide
Scenario 1: Connect Devices with and without Optical Interfaces
Ethernet device
with optical interfaces
Media Converter
1000Base-SX interface
Ethernet device
without optical interfaces
Gigabit Ethernet interface
Twisted-Pair Cable
Note:
1. Either two MC200CMs or two MC210CSs can work cooperatively. Two MC220Ls with the same SFP module can work cooperatively.
2. An MC220L can also cooperate with an MC200CM or an MC210CS. However, the mode and wavelength of the SFP module used in MC220L must be the same as the opposite end.
3. Connect the TX port of one converter to the RX port of the other using a ber cable.
Scenario 2: Connect Devices without Optical Interfaces
Fiber CableTwisted-Pair Cable Twisted-Pair Cable
Ethernet device
without optical interfaces
Media Converter Media Converter
Ethernet device
without optical interfaces
Enlarge Your Ethernet Network
For technical support and other information, please visit
http://www.tp-link.com/support, or simply scan the QR code.
MC200CM/ MC210CS/ MC220L
Note: MC200CM is used as an example throughout this guide. Other models may dier in appearance.
Gigabit Ethernet interface
Gigabit Ethernet interface
LED Explanation
On: Power on.
O: Power o.
PWR
On: There is a valid link for FX Port.
O: There is no valid link for FX Port.
Flashing: FX Port is transmitting or receiving data.
Link/Act
FX
On: There is a valid link for TP Port.
O: There is no valid link for TP Port.
Flashing: TP Port is transmitting or receiving data.
Link/Act
TP
Specications
Operation Temperature 0˚C to 40˚C (32˚F to 104˚F)
Storage Temperature -40˚C to 70˚C (-40˚F to 158˚F)
Storage Humidity 5% to 90%RH non-condensing
Operation Humidity 10% to 90%RH non-condensing
Environmental and Physical Specifications
IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE802.3zStandards
PWR, FX Link/Act, TP Link/Act
For MC200CM/MC210CS: SC ber connector, RJ-45 jack
For MC220L: SFP port, RJ-45 jack
LED
Twisted-Pair
Interface
General Specifications
External Power Adapter: 9V/0.6A
Wave Length
Fiber
Power
For MC200CM: 850nm
For MC210CS: 1310nm
For MC220L: depends on the used SFP module
For MC200CM: 62.5/125μm multi-mode ber (≤220m);
50/125μm multi-mode ber (≤550m)
For MC210CS: 9/125μm single-mode ber (≤15km)
For MC220L: depends on the used SFP module
10Base-T: 2-pair UTP/STP of Cat. 3 or above (≤100m)
100Base-TX: 2-pair UTP/STP of Cat. 5 or above (≤100m)
1000Base-T: 4-pair UTP/STP of Cat. 5e or above (≤100m)
This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user
may be required to take adequate measures.
CE Mark Warning
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired operation.
Any changes or modications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
FCC STATEMENT
Продукт сертифіковано згідно с правилами системи УкрСЕПРО на відповідність вимогам нормативних документів
та вимогам, що передбачені чинними законодавчими актами України.
CAN ICES-3 (A)/NMB-3(A)
Industry Canada Statement
EU declaration of conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of
directives 2014/30/EU, 2014/35/EU, 2009/125/EC and 2011/65/EU.
The original EU declaration of conformity may be found at http://www.tp-link.com/en/ce
A
VCCI-A
Safety Information
Keep the device away from water, re, humidity or hot environments.
Do not attempt to disassemble, repair, or modify the device.
Do not use damaged charger or USB cable to charge the device.
Do not use any other chargers than those recommended.
Adapter shall be installed near the equipment and shall be easily accessible.
Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.
Do not point or stare directly into the beam or into the optical port of the transceiver when it is operating, as this can injure
your eyesight.
BSMI Notice
  • Page 1 1
  • Page 2 2

TP-LINK MC200CM Quick Installation Guide

タイプ
Quick Installation Guide
このマニュアルも適しています

他の言語で