Hitachi RA-08JDF2 Operation and Installation Manual

カテゴリー
スプリットシステムエアコン
タイプ
Operation and Installation Manual

このマニュアルも適しています

– 2 –
SAFETY PRECAUTION
Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters which,
if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may
result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
” sign in attached figure indicates prohibition.
Please keep this manual after reading.
PRECAUTIONS DURING INSTALLATION
WARNING
Please ask your sales agent or qualified technician for the installation of your unit. Water
leakage, short circuit or fire may occur if you install the unit yourself.
Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor or the earth line
of telephone. Improper installation of earth line may cause electric shock.
A circuit breaker should be installed depending on the mounting site of the unit. Without
a circuit breaker, the danger of electric shock exists.
Do not install near location where there is flammable gas. The unit may catch fire if
flammable gas leaks around it.
Please ensure smooth flow of water when installing the drain hose. (For drain model)
CAUTION
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
WARNING
Should abnormal situation arises (like burning smell), please stop operating the unit and turn off the
circuit breaker. Contact your agent. Fault, short circuit or fire may occur if you continue to operate
the unit under abnormal situation.
Please contact your agent for maintenance. Improper self maintenance may cause electric shock
and fire.
Please contact your agent if you need to remove and reinstall the unit.
Electric shock or fire may occur if you remove and reinstall the unit yourself improperly.
PRECAUTIONS DURING OPERATION
Avoid an extended period of direct air flow for your health.
Do not put objects like thin rods into the panel of blower and suction side because the high-speed fan inside may cause
danger.
Do not use any conductor as fuse wire, this could cause fatal accident.
During thunder storm, disconnect and turn off the circuit breaker.
The product shall be operated under the manufacturer specification and not for any other intended use.
Do not attempt to operate the unit with wet hands, this could cause fatal accident.
When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen insufficiency.
Do not direct the cool air coming out from the air-conditioner panel to face household heating apparatus as this may affect
the working of apparatus such as the electric kettle, oven etc.
Please ensure that unit mounting frame is always stable, firm and without defect. If not, the unit may collapse and
cause danger.
Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit.
Do not place plants directly under the air flow as it is bad for the plants.
Please switch off the unit and turn off the circuit breaker during cleaning, the high-speed fan inside the unit may cause
danger.
Turn off the circuit breaker if the unit is not be operated for a long period.
Do not climb on the unit or put objects on it.
Do not put water container (like vase) on the unit to avoid water dripping into the unit. Dripping water will damage
the insulator inside the unit and causes short circuit.
When operating the unit with the door and windows opened, and with the air deflector facing down for a long period of time, water
will condensed on the air deflector and drips down occasionally. This will wet your furniture. Therefore, do not operate under such
condition for a long time.
If the amount of heat in the room is above the cooling capability of the unit (for example: more people entering the room, using heating
equipments and etc.), the preset room temperature cannot be achieved.
W
A
R
N
I
N
G
– 3 –
PARTS IDENTIFICATION AND OPERATIONS
1 Cabinet
2 Suction Grille
3 Horizontal Deflectors
4 Vertical Deflector
5 Air Exhaust Lever
6 Front Cover
7 Control Panel Cover
1
2
3
4
5
76
REMOTE CONTROLLER
CONTROL PANEL INDICATION LAMP
POWER SWITCH
AUTO SWING
SWITCH
TEMPORARY SWITCH
Use this switch to start operation and stop when
the remote controller does not work. Normally do
not use this switch.
RECEIVING PART
TIMER LAMP
This lamp lights when the
timer is set.
OPERATION lamp
This lamp lights when the
unit is operating.
DEHUMIDIFY lamp
This lamp lights when the
dry mode is working.
Model Width Height Depth
18
1
/
2
", 470mm 13
9
/
16
", 345mm 23
7
/
20
", 610mm
RA-08JDF2
RA-10JDF2
– 4 –
NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT
This controls the operation function and timer setting of the room air conditioner.
The range of control is about 4 meters. If indoor lighting is controlled electronically,
the range of control may be shorter.
Signal Transmission
ON/OFF Button
Press this button to start operation.
Press it again to stop operation.
FUNCTION Button
Select the operation mode.
( page 7)
SLEEP TIMER Button
Use this button to set the sleep
timer. ( page 6)
RESERVE Button
Timer setting reservation.
OFF TIMER Button
Select the turn OFF timer.
TRANSMISSION Sign
The transmission sign blinks
when a signal has been sent.
TEMPERATURE Button
Room temperature setting.
Value will change quicker when
keep pressing. ( page 7)
FAN SPEED Button
Select the fan speed for cooling
and circulation mode.
( page 7)
CANCEL Button
Cancel timer reservation.
ON TIMER Button
Select the turn ON timer.
Precautions for Use
Do not put the remote controller in direct
sunlight and high temperature.
Do not drop it on the floor, and protect it
from water.
If you press the FUNCTION selector
button during operation, the air
conditioner may stop for about 3 minutes
for protection before you can start it
again. (unless you turn off and on again
the power source)
You can use the remote controller by fixing it on the wall
with the accessory parts.
Before fixing it,
make sure the
unit can be
controlled by the
remote control
unit at the fixing
position.
HOLDER
REMOTE
CONTROLLER
BATTERIES INSTALLATION
The direction of batteries must match the mark in the case.
Do not mix use the old and new or different kinds of batteries together.
Take out the batteries when you do not use it for more than one month.
CAUTION
Slightly push
and slide out
the cover.
BATTERIES
Please use AAA type of batteries.
Life of batteries is about 1 year for normal usage.
Replace the batteries when the lighting of LCD becomes dim.
After replace the batteries and if operation is abnormal, take
out the batteries and install again after 5 seconds.
– 5 –
HOW TO USE
AUTOMATIC OPERATION
The device will automatically determine the operation mode either COOL or
DEHUMIDIFY depending on the initial room temperature.
Press the (START/STOP) button
Operation start with a “beep”.
Press the (START/STOP) button
Please make sure you have selected the (Automatic) mode
by using the (FUNCTION) button.
The starting operation will occur an abnormal sound (turbo
sound) which doesn’t affect the operation.
The fan speed selector does not work at this operation.
1
STOP
You can slightly adjust the room temperature.
Press the (ROOM TEMPERATURE) button
Temperature setting change by 1°C for each 1 time press.
2 Up
2 Down
You can raise or lower the temperature setting by a maximum of
3°C.
The display does not indicate the preset temperature in the
Automatic
mode. Device will receive the setting by a “beep”.
1
CONDITION OF AUTOMATIC OPERATION
The selected mode of operation will not change during the operation even though the room
temperature change.
Initial room temperature
Function Temperature setting FAN SPEED
(approx.)
HIGH at start, LOW after
Over 27°C COOL 27°C the preset temperature is
reached
16 ~ 27°C DEHUMIDIFY
Slightly lower than the
QUIET
room temperature
– 6 –
HOW TO SET THE SLEEP TIMER
When the room temperature is higher than the thermostat set temperature, only the fan operates to
circulate the upper hotter air downwards. This makes temperature distribution of the room evenly at
heating. This operation is useful in winter when using other heating equipment.
Press the (START/STOP) button
Operation start with a signal received sound “beep”.
Press the (START/STOP) button
Make sure you have select the (Circulate) mode by using
the (FUNCTION) button.
You can select the fan speed and desired temperature.
1
STOP
Example: Setting 3 hours
sleep time.
THE RANGE OF CONTROL FOR WIRELESS REMOTE CONTROL UNIT
Mode Indication
Sleep Timer
1 hour 2 hours
Sleep timer off
3 hours 7 hours
Sleep Timer: The device will continue working for the desired
number of hours and then turn off.
Point the signal window of the remote controller toward the
unit, and press the
(SLEEP TIMER) button.
The timer information will be displayed on the remote
controller.
The TIMER lamp lights with a beep.
CIRCULATION OPERATION
ROOM AIR
CONDITIONER
ROOM AIR CONDITIONER
RECEIVING PART
CEILING
RECEIVING PART
about 20°
about 3m
WALL
FLOOR
REMOTE CONTROL
UNIT
about
75°
4m
about
50°
about
50°
– 7 –
MANUAL OPERATION [Cooling
Dehumidify
Circulation]
Please use under below condition when you want to set the function mode, room temperature and
fan speed by manually.
DEHUMIDIFYING COOLING
Room Temperature Outdoor Temperature
16°C above 22–42°C
OPERATION MODE SELECTION
Every time you press the button, the mode will change as the
below sequence.
(Auto) (Cool) (Dehumidify) (Circulation)
1
ROOM TEMPERATURE SETTING
2 Up
2 Down
The cooling operation does not start if the
temperature setting is higher than the current
room temperature.
2
FAN SPEED SETTING
Every time you press the button, fan speed will change as the below
sequence.
COOLING :
CIRCULATION :
DEHUMIDIFY :
(QUIET) (FIXED)
(QUIET)(LOW)(HIGH)
(QUIET)(LOW)(HIGH)(Auto)
3
Press the (START/STOP) button
Operation start with a signal received sound “beep”.
Press the (START/STOP) button
As the settings are stored in memory in the remote control unit, you only
have to press the (START/STOP) button next time.
4
STOP
Recommend Temperature
Dehumidify 16~26°C
Cooling 25~28°C
– 8 –
Operation condition depend on the setting Temperature.
SETTING TEMPERATURE OPERATION CONDITION
LOWER THAN ROOM
TEMPERATURE
HIGHER THAN ROOM
TEMPERATURE
Device will dehumidify, reducing the room temperature to the
preset level.
Operation stop when room temperature becomes lower than
setting temperature and start again operation when it is higher
than setting temperature.
Dehumidifying will be performed with the room temperature set
slightly lower than the current room temperature regardless the
temperature setting. (When room temperature is lower 16°C,
setting temperature will be 16°C.)
Operation stop when room temperature becomes lower than
setting temperature and start again operation when it is higher
than setting temperature.
FAN SPEED MODE AND OPERATION CONDITION
CIRCULATION COOLING
“Auto” Not available
“High” Full speed for room temperature distribution. Quick cooling for economical operation
“Low” Quiet
“Quiet” Super Quiet
High speed at the starting of operation
and change to low when the preset
temperature has been achieved.
CAUTION
Continuous operation at high humidify (over 80% at indoors) will cause some dews form on the air outlet grille
of the unit.
– 9 –
OFF TIME setting
Select the OFF TIME by pressing the
(OFF) button.
Setting time will change according to the below
sequence when you press the button.
0.5 hour interval 1 hour interval
The value change more quickly if you keep pressing
the button.
Press the (Reserve) button
OFF TIMER reserved with a signal received
sound “beep”.
The (OFF) Mark starts lighting instead of
blinking.
1
OFF Timer Reservation
2
ON TIME setting
Select the ON TIME by pressing the (ON)
button.
At the beginning of setting, time 6 hours was set.
Setting time will change according to the below
sequence.
0.5 hour interval 1 hour interval
The value change more quickly if you keep pressing
the button.
Press the (Reserve) button
ON TIMER reserved with a signal received
sound “beep”.
The (ON) Mark starts lighting instead of blinking.
1
2
ON Timer Reservation
1
Press the (Cancel) button
As the time settings are stored in remote controller
memory, you only have to press the (Reserve)
button in order to use the same setting next time.
CANCELLATION of Timer Reservation
Operation stop at setting time
ON Timer and OFF Timer are available.
TIMER RESERVATION
Operation will start for setting
temperature at setting time (The starting
time may different depend on the room
temperature and set temperature).
– 10 –
AIR DEFLECTORS
VERTICAL DEFLECTORS
Vertical deflectors at both sides of outlets can
be set to either auto-swing or static position to
direct discharge air rightward, leftward or
forward direction.
HORIZONTAL DEFLECTORS
Horizontal deflectors at both sides of the outlets
can be set to direct discharge air upward,
downward or forward direction.
Vertical
Deflector
Vertical
Deflector
Horizontal
Deflectors
Horizontal
Deflectors
CAUTION
To avoid dew forming on the deflectors which eventually may drip to the floor, please do not adjust
horizontal deflectors extremely downward position or vertical deflectors extremely leftward or
rightward position during cool operation for a long time.
Also, do not adjust the vertical deflectors position by hand or any other object.
Set the air exhaust lever to the OPEN (pull) position for
air ventilation in the room. The air exhaust lever should
normally be kept in CLOSE (push inward) position
during cooling operation and in the case of typhoon.
Air Exhaust Lever
AIR EXHAUST LEVER
Use the temporary switch for start or stop
operation when operation cannot be done with
the remote controller.
By pressing the temporary switch, [use non-
conductor stick (example toothpick)], the
operation is done in previously set operation
mode.
When the operation is done using the temporary
switch, after the power source is turned off and
is turned on again, the operation is done in
automatic mode.
TEMPORARY SWITCH
POWER SWITCH
AUTO SWING SWITCH
When the AUTO SWING switch is turned to “ON” position, the vertical deflectors automatically oscillate
right and left sweeping the cold air alternately to obtain comfortable cooling.
The vertical deflectors may be stopped at any position when the AUTO SWING switch is turned “OFF”.
When you do not use the room air conditioner, set the power switch to “OFF”.
POWER SWITCH
TEMPORARY
SWITCH
AUTO SWING
SWITCH
– 11 –
ALWAYS STOP THE OPERATION BEFORE INSTALLING THE AIR CLEANING FILTER.
AIR CLEANING FILTER IS WASHABLE AND REUSABLE UP TO 20 TIMES BY USING VACUUM
CLEANER OR RINSE WITH RUNNING TAP WATER.
AIR CLEANING FILTER SHOULD BE CLEANED EVERY MONTH OR SOONER IF NOTICEABLE
LOADING OCCURS. WHEN USE OVERTIME, IT MAY LOSE ITS DEODORIZING FUNCTION.
FOR MAXIMUM PERFORMANCE, IT IS RECOMMENDED TO REPLACE IT EVERY 3-6 MONTHS
DEPENDING ON APPLICATION REQUIREMENT.
TYPE NUMBER FOR THIS AIR CLEANING FILTER IS <SPX-CFH8W>, PLEASE USE THIS
NUMBER FOR ORDERING WHEN YOU WANT TO RENEW IT.
TEMPERATURE AND HUMIDITY
Avoid to use the room air conditioner for cooling operation when the outside temperature is below
21°C (70°F). Recommended operation humidity should be below 80%. Continuous long operation at
over 80% humidity (indoor) will cause some dews form on the outlet grille of the unit.
NOISE
In a quiet environment or stopping and starting operation, phenomena like flowing noise of
refrigerant in the refrigerating cycle and rubbing noise from the fan casing may occasionally occur,
but this is normal for the operation.
Water will condense on the evaporator coil and collected in the bottom tray, it is picked up by the
condenser fan and blown onto the condenser coil, this creates a “splashing” noise which is normal.
ODOR
The odor will possibly be emitted from the room air conditioner especially at the starting of operation
and in a high humidity condition. This is not abnormal phenomena because of the various kind of
odors emitted by smoke, food stuffs, cosmetics and others which may stick to the room air
conditioner. So, please clean the air filter and evaporator at the beginning of long no operation period
to reduce the odor.
NOTES ON OPERATION
Air Cleaning
Filter
Hook
1. Open the suction grille
2. Remove the normal
filter
3. Install the air cleaning filter
in the frame
4. Install back the normal filter
and close the suction grille
– 12 –
THE IDEAL WAYS OF OPERATION
FOR USER’S INFORMATION
The Air Conditioner And The Heat Source In The Room
Caution
If the amount of heat in the room is above the cooling capability of the air
conditioner (for example: more people entering the room, using heating
equipments and etc.), the preset room temperature cannot be achieved.
After Power Failure
Not Operating For A Long Time
When Lightning Occurs
Warning
To protect the whole unit during lightning, please stop operating the unit
and remove the plug from the socket.
VentilationSuitable Room Temperature
Warning
Freezing temperature
is bad for health and a
waste of electric
power.
Install Curtain or Blinds
It is possible to
reduce heat
entering the room
through windows.
Caution
Do not close the room for a long
period of time. Occasionally open the
door and windows to
allow the entrance
of fresh air.
When the power is resumed after a power failure, the unit will still remain
“OFF”. To operate the unit, please press the “ON/OFF” button again.
(For remote control type only)
When the unit is not to be used for a long period of time, please switch off the
power from the mains. If the power from mains remains “ON”, the unit still consumes
about 10W in the operation control circuit even if it is in “OFF” mode.
(For remote control type only)
Please Adjust Suitable Temperature
For Baby And Children
Do Not Forget To Clean The Air Filter
Dusty air filter will reduce the air
volume and the cooling efficiency. To
prevent from
wasting electric
energy, please
clean the filter
every 2 weeks.
Please pay attention to the room
temperature and air flow
direction when operating
the unit for baby, children
and old folks who have
difficulty in movement.
Effective Usage Of Timer
At night, please use the “OFF or ON timer
operation mode”, together with your wake
up time in the morning. This will enable you
to enjoy a comfortable room temperature.
Please use the timer
effectively. (Wireless
remote control model only)
Operate
After power
failure
OFF
– 13 –
MAINTENANCE
CAUTION
ALWAYS TURN OFF AND UNPLUG BEFORE ANY CLEANING
OR MAINTENANCE TO ENSURE SAFETY.
If the air filter is clogged with dust, the air flow volume will decrease and resulting in poor
cooling performance, and increased operating noise. Be sure to clean the filter about every
20 days.
1 Remove the suction grille by pulling at both
bottom corner and then lift it up slightly before
pull downward to unhook the suction grille.
2 Lift and unhook the bottom of the air filter and
remove it.
3 Remove dust from the filter by using a vacuum
cleaner. If the filter is very dirty, wash it with
detergent and rinse properly with water. Dry it
with soft cloth and do not expose it to heat or
under direct sunlight.
4 Install the filter by fitting the top hooks and then
hook the bottom of the filter.
5 Attach the suction grille back to its place by
hooking at the top side to the front cover, then
gently push at both bottom corner.
CAUTION
Do not use hot water above 40°C for cleaning the filter.
Do not operate the air conditioner with the filter removed.
AIR FILTER
SUCTION
GRILLE
HOOK
– 14 –
Clean the front cover and suction grille with a soft dry cloth. When it is excessively dirty, wipe
it with a soft cloth dampened with mild soap, then wipe it again thoroughly with a soft dry
cloth.
The suction grille can also be removed and be washed with water and mild soap. Remove
the suction grille in the following manner.
1 Pull the suction grille at both bottom
corner and released it.
2 Lift up the suction grille slightly.
3 Remove the suction grille by pulling
downward to release it from the hook
hole located at the top side.
BEFORE ASKING FOR SERVICE
Check the following items before asking for service. If the malfunction persists,
please contact service centre.
Symptom Cause
Does not operate 1 Is the power cord loosened or unplugged?
at all 2 Is the fuse blown out or the circuit breaker tripped?
3 Is the voltage normal?
4 Is the main switch set to “OFF” position?
Poor cooling 1 Is the air filter covered with heavy dust?
performance Clean the filter and replace it.
2 Is the temperature setting correctly?
3 Is the sunlight fall directly in the air conditioner?
4 Is the air flow on the rear side (outdoor) blocked?
Leave a space of 900 mm (3 feet) behind the rear side of air
conditioner.
5 The doors or windows may be opened widely or there are
other sources of heat in the room.
6 Is the ventilation damper opened?
CAUTIONS
IF THE POWER SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE ONE
SPECIALLY PREPARED AND ONLY AVAILABLE FROM THE MANUFACTURER OR ITS
SERVICE AGENT.
CAUTION
FRONT COVER AND SUCTION GRILLE
Never use hot water above 50°C, erosive chemicals or brush to clean the front cover and
suction grille because they will damage the plastic surface.
– 15 –
Wall
494mm
357m
m
Over 200mm
Over
100mm
Over 150mm
Outdoor
Side
Wall or
obstacles
Over
900mm
5mm
266mm
Screw
Indoor
Side
80mm
Over
1200mm
Floor
Side View
Over
200mm
Over
200mm
Back View
-5~5mm
INSTALLATION INSTRUCTIONS
REMOVE ALL THE SHIPPING PARTS BEFORE
INSTALLATION AND CONSULT YOUR DEALER
CONCERNING INSTALLATION REQUIREMENTS.
Select a location that can support the weight of the air conditioner and will not cause
increased operating noise and vibration.
Select a location where direct sunlight does not fall on your air conditioner.
Select a good location for efficient air circulation.
Select a place where there is no obstacles near the air inlet and outlet.
LOCATION
CAUTION
The installation material must be fully strong against corrosion, especially in case the air
conditioner to be installed near the sea or hot spring.
Do not install air conditioner in the places where there is a possibility of inflammable gas
leaks.
Secure tightly the cabinet with screws. Otherwise there may be danger of the air conditioner
dropping.
Please keep the recommended installation dimensions. Otherwise waterdrops may occur.
Indoor
side
Outdoor
side
– 16 –
POWER SOURCE
Check the capacity of wiring and power outlet. The power outlet should be used exclusively
for the air conditioner. Do not use it with other appliances. Any wiring must follow the
national wiring regulation.
Ground the air conditioner to prevent danger of electric shock.
Connect the air conditioner with power source securely.
Use a fuse as below:
Voltage rating 50Hz 220-240V
Operatable
50Hz 198-264V
Voltage range
CAUTION
WARNING – THIS APPLIANCE MUST BE EARTHED.
REMOVE THE FRONT COVER
Remove the front cover in the following manner.
1 Pull the suction grille at both bottom corner and
release it.
2 Remove the air filter.
3 Remove two screws which secure the front cover.
4 Remove the front cover from lower side.
15A time delay fuse
RA-08JDF2
RA-10JDF2
– 17 –
SLIDE OUT OF UNIT
1 Remove the four screws which
fasten the base pan to the cabinet
at the side and back.
2 Slide out the unit by pulling the
handles.
After slide in the unit, please install the sealer between the base pan and cabinet to prevent
from entering rain water in case of typhoon. Fasten the unit to cabinet at the side with the
screw, then refit the front cover.
Sealer
Handle
95mm
POWER CORD ARRANGEMENT
If power cord is withdrawn from left side
of unit, please arrange the power cord as
in figure after installing the front cover.
Power
cord
Front cover
(Inside view)
Guider
Base pan
Minimum
30mm
When the screws at the both side of the cabinet cannot be fasten, please use the stopper (a
“L” shape metal plate that is provided in the plastic bag with the sealer) to fix the cabinet and
the base pan located at in front of the unit.
The steps to fix the stopper are as below:
1 Remove the screw which fasten the plastic band
and electrical box to the base pan.
2 Fix and align the stopper into the rectangular
hole of the cabinet.
3 Fasten back the screw to fix plastic band, stopper
and electrical box to the base pan.
STOPPER
TEMPERATURE
TEST
COOLER
1
2
3
4
5
6
7
Cabinet
Electrical box
Stopper
Base pan
Plastic band
Control panel
– 18 –
INSTALLATION WORK INSPECTION CHECK LIST
DRAIN PAN
CONDENSED WATER DRAINAGE
This air conditioner employs a “turbo fan splashing ring” which is designed to splash
the condensated water on the condenser surface for maximum cooling efficiency,
thus producing a splashing sound.
If you are uncomfortable with the sound, you can install an outside drainage by using
the following procedure which may, however cause a small loss of performance.
1 Remove the rubber plug from the base pan.
2 Install the drain pan by using 2 pieces of screws
(provided) at the cabinet.
3 Connect the drain pan with the drain hose. (Drain
hose or tubing can be purchase locally to satisfy
your particular needs. Drain hose inner diameter
size should be around ø13mm or 1/2 inch.)
4 Slide the air conditioner unit back into the cabinet.
Item No. Check Item Initials
1
Have you removed the shipping parts? Please check
the caution sheet which was attached at front cover.
2
Is the incline of room air conditioner regarding
front and rear, right and left all right after installation?
3 Is the strength of installation sufficient?
4 Have you grounded your room air conditioner?
5 Have you fastened the unit to the cabinet?
6
Have you done a test operation, and are there
any abnormal phenomena?
Drain hose
Rubber plug
Screws
Drain pan
Cabinet
CAUTION
BEFORE START OPERATION OF AUTO SWING FUNCTION, PLEASE TURN THE RIGHT
VERTICAL DEFLECTOR TO THE MOST RIGHTWARD AND SWITCH ON THE AUTO SWING
SWITCH TO CHECK THE VERTICAL DEFLECTOR MOVEMENT.
THE ABNORMAL SOUND WILL OCCUR DURING VERTICAL DEFLECTOR ADJUSTMENT
AND IT DOESN'T AFFECT THE AUTO-SWING OPERATION.
DURING USAGE IF THE VERTICAL DEFLECTOR CHANGES ANGLE THEN PLEASE DO
THE ABOVE SETTING AGAIN.
WHEN RAINING, RAIN WATER WILL ENTER THE OUTDOOR UNIT. WHEN THE AIR
CONDITIONER STARTS OPERATING (AFTER RAINING) FOR ABOUT 10 MINUTES, THERE
WILL BE AN ABNORMAL NOISE FROM OUTDOOR UNIT. THIS WILL NOT EFFECT THE
PERFORMANCE OR LIABILITY OF THE AIR CONDITIONER.
– 19 –
安全上應特別注意之事項
使用前,請詳細閱讀「安全上的注意事項」,以正確的使用機體。
在所示注意事項的 警告”、 注意需特別加以注意。“警告”欄中記載之事項,表示處理錯誤時,
可能會造成死亡或重傷,而“注意”欄中記載之事項,因狀況也可能造成重大之後果,所以請務必遵守,以
維護安全。
另外圖像中的 表示禁止事項。
閱讀完後,請務必妥善保管。
安裝上的注意事項
警告
安裝時,請委託經銷商或專門技術人員安裝。
自己安裝可能會造成漏水、觸電及火災。
請使用接地線。
地線請勿安裝在瓦斯管、水管、避雷針、電話之地線等場所。
依設置場所狀況,有必要安裝漏電斷電器。
如沒有安裝漏電斷電器時,會有觸電的危險。
不可安裝於有可燃氣體的場所,因為萬一氣體泄漏在機體周圍的
話,可能會發生火災。
安裝排水管時,請確認水可否順利的流出。(排水管型
注意
搬移或修理時的注意事項
警告
異常時(有焦味等),請停止運轉後把斷電器關閉,並通知經銷服務人
員。有異常而照舊連續運轉的話,會造成故障、觸電、火災等。
維修時,請直接向經銷服務人員接洽。
自己修理不完全的話,會有觸電、火的危險。
機體要移動重新再設置時,請直接向經銷服務人員接洽。
自己移動機體,重新再設置時,若安裝不安全的話,就會有觸電、火的危險。
使用上的注意事項
身體請勿長時間直接對著冷氣,以免妨礙健康。
請勿將細棒等物品插入吹出口及吸入口,由於風扇在高速運轉,易造成危險。
請勿以金屬或銅線當作保險絲,以免發生故障或火災。
有打雷之可能時,為了保護機械,請停止運轉,並把斷電器關閉,以避免故障發生。
本機請使用在以一般家庭的人為對象的場所,請勿使用在保存食品、動植物、精密機
器、美術品、醫藥品等特殊場所。
請不要用濕手來操作開關,以免觸電。
與燃燒器具一起運轉時,請常換氣,否則會有氧氣不足的情形。
本機所吹出來的風,請不要直接吹在燃燒器具上,否則,會使燃燒器具燃燒不完全。
長期使用的安裝材料請隨時注意其是否穩固,不可有損傷的情形。否則機體可能會落
下造成危險。
清洗機體時,請絕對避免用水潑機體,因會有漏電的危險。
動植物請不要放置在風向直接吹到的場所,否則會對動植物有不良的影嚮。
清潔機體時,請停止運轉並把斷電器關閉。因為機體內部的風扇正以高速運轉,會造
成傷害。
長時間不運轉時,為了安全起見,請把斷電器關閉。
請勿爬上機體,物品也不要放在機體上面。
機體上請不要放有水的容器(如花瓶),以免傾倒流入機體內部,會使機體內部
電氣絕緣劣化,產生觸電的危險。
冷氣運轉時,窗和門在開放的狀態下,風向板向下時,都請不要長時間運轉,否則上下風向板
會結露,有時會滴下來,而使傢俱弄濕。
房間如果有超過冷氣能力的熱源(如房間有多人進入,使用熱器具等),將無法達到所設定室溫。
– 20 –
部件名稱及操作
1 機箱
2 吸氣柵
3 水平風向調整板
4 垂直風向調整板
5 排氣桿
6 前面蓋
7 控制板蓋
遙控器
控制板 指示燈
電源開關
自動搖擺開關
接收部
定時器燈
定時器設定後這指示
燈點亮。
操作燈
機器操作中這指示燈
點亮。
1
2
3
4
5
76
暫時開關
遙控器失靈時請用此鈕
開動或停止機器,但通
常不需要使用此鈕。
除濕燈
機器開始除濕操作
時這指示燈點亮。
23
7
/
20
"
, 610mm
18
1
/
2
"
, 470mm
13
9
/
16
"
, 345mm
RA-08JDF2
RA-10JDF2
型號
寬度
長度高度
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Hitachi RA-08JDF2 Operation and Installation Manual

カテゴリー
スプリットシステムエアコン
タイプ
Operation and Installation Manual
このマニュアルも適しています

他の言語で