Warning
Caution
Warning
Caution Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer's application or use of the Product. At Buyer's request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer's application, product or system. Buyer
shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT
THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR
THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69,2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300
Fax: (31)2356-81-388
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road #05-05/08
(Lobby 2), Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011
Fax: (65) 6835-2711
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900
Fax: (1) 847-843-7787
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
Pu Dong New Area, Shanghai,
200120, China
Tel: (86) 21-5037-2222
Fax: (86) 21-5037-2200
Note: Specifications subject to change without notice.
OMRON Corporation Industrial Automation Company
Contact: www.ia.omron.com
Kyoto, JAPAN
Switching Hub
W4S1-series
Users Manual
Thank you for purchasing OMRON Switching Hub.
To secure safe operation, please be sure to read this manual.
Keep this manual in a safe location and be sure that it is readily
available to your final users of the product.
© OMRON Corporation 2008-2018 All Rights Reserved.
0969584-7E
OMRON Corporation
Safety Precautions
Each Part Name
Dimension
Troubleshooting
Summary for safety
Definition of the precaution and warnings
Warnings
Wrong operation could result in minor or moderate
injury. If the worst happens, it may result in death,
serious injury and property damage.
Wrong operation may result in minor or moderate
injury and property damage.
Don’t disassemble and touch any unit while the power is
supplied. Doing so may result in electrical shock.
Don’t touch any of the terminals while the power is supplied.
Doing so may result in electrical shock.
Take a fail-safe countermeasures by the customer to secure
safety in case of an abnormal signal caused by broken signal
line and momentary power interruption. Not doing so may
result in serious accidents.
Pay careful attention to the polarities(+/-) when wiring the
DC power supply. A wrong connection may cause
malfunction of the system.
Take appropriate countermeasures such as installing external breakers to ensure
safety in case of short-circuiting in external wiring.
Mount the unit only after checking the terminal blocks and the connectors
completely.
Be sure that screws of the terminal blocks are tightened to the torque specified in
this manual.
Wire correctly.
Use the power supply voltage specified in this manuals.
Be particularly careful the place where the power supply is unstable to secure the
power with the rated voltage. Use CLASS2 power supply.
Do not allow wire clippings, shavings, or other foreign material to enter any Unit.
Otherwise, Unit burning, failure, or malfunction may occur. Cover the Units or take
other suitable countermeasures, especially during wiring work.
Do not allow foreign matter to enter the openings in the Unit. Doing so may result in
Unit burning, electric shock, or failure.
Be sure to ground when installing the unit.
Supply the power only after proper and sufficient checking of the wiring and switch.
Don’t attempt to disassemble, repair and modify this unit.
Don’t pull on the cables or bent them beyond its manual unit.
Don’t place objects on cables and codes.
Before touching the unit, be sure to first touch a grounded metallic object in order
to discharge any static built-up.
This unit is class A (Industry Environment product). A usage in living may result in
interruption of electric frequency. Take a proper countermeasure against the
interruption of electric frequency when its case.
Locations subject to direct sunlight.
Locations subject to temperature or humidity outside the range specified in the
specification.
Locations subject to condensation as the result of severe change in temperature.
Locations subject to corrosive or flammable gas.
Locations subject to dust Especially iron dust) or salt.
Locations subject to exposure to water, oil, or chemicals.
Locations subject to shock and vibration.
Take appropriate and sufficient countermeasures when installing system in the
following locations;
Location subject to static electricity or other forms of noise.
Location subject to strong electromagnetic field.
Location subject to possible exposure to radioactivity.
PWR
L/A
100
QoS
*2
Extinction Power OFF
Lit Power ON
Extinction No error
Lit Control LSI Error
Blinking Broadcast Storm Detection
Extinction No connect or No link when
connection
Lit Link, No data communication
Blinking Link, Data communication
When L/A is lit and blinked,
Extinction Link in 10M
Blinking Link in 100M
Extinction QoS Control Invalid
(when QoS SW is OFF)
Blinking QoS Control Valid
(when Qos SW is ON.
Green
Yellow
Yellow
Yellow
ERR
*1 Red
LED
Switch
Abnormal Information Connector
OFF QoS Control Invalid
ON QoS Control Valid
ConnectSituation
Power
Supply
*1) The function is limited only for W4S1-05C.
It isn’t mounted on W4S1-03B/05B.
*2) Valid or Invalid of QoS controlling depends on Qos SW when power ON.
Even if SW is replaced, during Power ON, it isn’t reflected on LED and the
function isn’t converted.
To change Qos condition, shut down the power supply and replace SW.
Connector for
Informing abnormal
Only W4S1-05C
TB FRONT-MC 1.5/2ST3.81
Wire Diameter 0.14-1.5mm2
Torque for tightening
1.95-2.21lbf (0.22-0.25Nm)
Rated Load:
AC125V 0.5A, DC30V 1A
Opening and Closing:
More than 200 thousands times
Power Supply Connector
+24V
GND
FG
TB FRONT-MC1.5/3-ST-3.81
Wire Range: AWG16 – 30
(Diameter: 0.25-1.29mm)
Torque for tightening:
4 lbf.in
LAN Port
3ports W4S1-03B
5ports W4S1-05B/C
Indication LED
L/A Link,ACT
100 100/10M
PWR Power Supply
ERR Error Detection
(Only W4S1-05C)
QoS QoS Valid or Invalid
QoS SW
ON :QoS valid
QoS OFF:QoS invalid
Fig means W4S1-05C.
W4S1-03B
W4S1-05B/C
QoS SW
*2
When Normal
When LSI is abnormal
When it detects Broadcast storm
Here is the abnormal causes and the proper troubleshooting to take SW.
SW Cause User’s Countermeasure
Even if the power is ON,
all the LED isn’t lit.
Without power supply,
Power Supply
Disconnection
Internal Power Supply
is broken.
Confirming if power voltage
24V is supplied.
Changing Switching Hub
L/A LED isn’t lit. LAN Cable comes off
LAN Cable
disconnection,
short-circuiting
LSI Abnormal
Confirming Connector
Connection
Cable Changing
Changing Switching Hub
Abnormal contact point
is unlocked.
ERR LED is lit.
W4S1-05C
Loud Noise
LSI Abnormal
Improving the setting
environment
Changing Switching Hub
(When the power supply is
re-ON)
ERR LED is blinked.
W4S1-05C
Broadcast storm occurs. Unlocking loop connection
Unlock
Lock
Unlock
Lock
OFF
ON
LAN Cable
When using twist pair (STP) cable with a shield, it is expected to prevent a noise.
However, as the shield of the cable is installed in this unit, the both side of LAN
cable may be grounded. Attempt to ground its other side and use twist pair cable
(UTP) without shield when grounding its both side may lead ground electric
difference.
QoS Function
Qos can compare Implicit Message with other standard packet and transfer it by
priority.
The Implicit Message is I/O data for EIP controlling. Turn off Qos when
using it in normal mode, which has no function to put priority.
Priority when QoS is ON is the following.
Priority
1
2
3
EtherNet/IPTM Implicit Message
IGMP Packet
Other than the above
Detail
Power Voltage DC24V±5%
Consumption
Electric Power
220mA [Less than 5.28W]
Incoming Current Ip=1.42A
Voltage Proof AC250V 1mA for 1minute
(LAN Connector, Connector for informing abnormal ,FG
vs. Power Supply Connector
EMI / EMS EN61000-6-4:2007 / EN61000-6-2:2005
Noise proof and
Impact proof
Complied with JIS C60068-2-6, JIS C60068-2-27
Way of setting It is set in the switching hub
Usage circumstance No Corrosive gas
Usage surrounding
air Temperature 0˚C 55˚C No Freezing and No Condensation)
Usage surrounding
air Humidity
10 90 Relative Humidity(No Condensation)
Storage surrounding
air Temperature
20 75˚C (No Freezing and No Condensation)
Buffer Size 80Kbyte
MAC Address
Amount
2048 pieces
Specification
Conformance to EN Standard
Indoor use only
Altitude: Max. 2000 m
Installation environment: Over Voltage Category Pollution Degree 2
The maximum terminal temperature is 80
Use SELV Power Source for the DC main power source.
Set successfully. A slider side of the unit must be down. Hitch the upside hook
back of the unit on DIN trail and push its downside. When removing the unit, push
down sliders with a driver and pull out the unit from downside.
Don’t operate the system in the following places;
Application Precaution
SUITABILITY FOR USE
78
90
MOVING
POSITION
MOVING
POSITION
82.6
25°
25°
25°
25°
8
23.6
44.6
65.6
25
1.2
13.5
5.1
2.72
78
90
82.6
25°
25°
25°
25°
8
23.6
44.6
65.6
48
10.3 10.3
5.1
6.9
23
13.72
13.4