Silent - Smart - Powerful
ReefRun DC Pump
Red Sea ReefRun®
4
Red Sea ReefRun®
5
ENG
Contents
Introduction..........................................................................6
Safety ..................................................................................7
Data Sheet...........................................................................8
ReefRun Components........................................................9
Installation & Operation ..................................................10
Connecting to the ReefRun Dual Controller....................12
Pump Maintenance...........................................................13
Warranty.............................................................................14
Red Sea ReefRun®
6
Introduction
Congratulations on your purchase of Red Sea’s ReefRun® DC Pump.
This manual covers the physical installation and maintenance of the
ReefRun pumps.
The ReefRun pumps can only be used when connected to a ReefRun
Dual controller that provides control of up to 2 ReefRun compatible DC
return pumps, DC skimmer or a combination of both. Read the manual
provided with the ReefRun Dual controller for full installation and
operation instructions for the controller.
The ReefRun Dual Controller is part of Red Sea’s suite of smart devices
that are operated via Wi-Fi by Red Sea’s ReefBeat® App, which needs to
be installed on a smart mobile device with internet connectivity.
Welcome to Red Sea’s smart reef-keeping.
Sincerely,
The Red Sea Team
Red Sea ReefRun®
7
ENG
Safety
PLEASE READ AND FOLLOW ALL SAFETY INSTRUCTIONS
THIS DEVICE IS INTENDED FOR INDOOR USE ONLY.
DANGER: To avoid possible electric shock, special care should be taken
when handling a wet aquarium. For each of the following
situations, do not attempt repairs yourself; return the appliance
to an authorized service facility for service or discard the
appliance.
WARNING: To guard against injury, basic safety precautions should be
observed, including the following:
Do not operate any appliance if it has a damaged cord or plug, if it is
malfunctioning, or if it is dropped or damaged in any manner.
This appliance can be used by children aged from 8 years and above and
persons with
reduced physical, sensory, or mental capabilities or lack of experience
and knowledge if they
have been given supervision or instruction concerning use of the
appliance in a safe way and
understand the hazards
involved. Children shall not play
with the appliance. Cleaning
and user maintenance shall not
be made by children without
supervision.
The appliance is only to be used
with the power supply unit
provided with the appliance.
Close supervision is necessary when any appliance is used by or near
children.
To avoid injury, do not contact moving parts.
Always unplug an appliance from an outlet when not in use, before
putting on or taking off parts, and before cleaning. Never pull the
cord itself to remove the plug from the outlet. Grasp the plug and pull
to disconnect.
Do not use an appliance for anything other than its intended use.
The use of attachments not recommended or sold by the appliance
manufacturer may cause unsafe conditions.
Do not install or store the appliance where it will be exposed to the
weather or to temperatures below freezing point.
Make sure an appliance is securely installed before operating it.
Read and observe all the important notices on the appliance.
Note: A cord rated for less amperes or watts than the appliance
rating may overheat. Care should be taken to arrange the
cord so that it cannot be tripped over or pulled accidentally.
Do not use if cord is damaged. In case of need, do not
attempt to replace or repair yourself; return the appliance
to an authorized service facility for service or discard the
appliance.
In case of need, do not attempt to replace yourself; return
the appliance to an authorized service facility for service or
discard the appliance.
Red Sea ReefRun®
8
ReefRun 5500 ReefRun 7000 ReefRun 9000
Q min - MAX 2000-5500 l/h
530 - 1450 US gph
3000-7000 l/h
800 - 1900 US gph
4000-9000 l/h
1000 - 2500 US gph
H min - MAX 1.0-3.5 m
3.5-11.5 ft
2.0-5.0 m
6.5-16.5 ft
2.6-7.0 m
8.5-23.0 ft
WATT 10 - 40 W 20 - 65 W 30 - 95 W
Typical
aquarium
return
height
ReefRun 9000
ReefRun 7000
ReefRun 5500
Q MAX 0
01000
264 3000
792 5000
1320 7000
1849 9000
2377 l/h
US gph
m
7
6
5
4
3
2
1
ft
23.0
19.7
16.4
13.1
9.9
6.6
3.3
Data Sheet
Red Sea ReefRun®
9
ENG
ReefRun Components
Male threaded
1” GAS
Female threaded
1” GAS
Female threaded ring 1" GAS
Male threaded ring 1" GAS
Inlet grid with female
threaded 1" GAS
Connector for 25mm & ¾" rigid pipe
Connector for 32mm & 1" rigid pipe
R35564 Pump outlet fitting set
R35565 Pump
flow guide
Impellor + Ceramic
shaft + O-ring
R35571 (RR 9000)
R35572 (RR 7000)
R35573 (RR 5500)
Pump outlet chamber
with retainer ring
R35589 (RR 7000/9000)
R35588 (RR 5500)
R35566
Pump legs
R35563
Pump controller
cable
R35587
Pump outlet
chamber O-ring
Bottom bearing + hook
R33583 (RR 7000/9000)
R33584 (RR 5500)
Pump
R33567 (RR 5500)
R33568 (RR 7000)
R33569 (RR 9000)
Power Supply
R33577 (RR 9000)
R33576 (RR 7000)
R33575 (RR 5500)
RR 5500 Hose barb for 17/25mm (" / 1")
RR 7000/9000 Hose barb for 25/32mm (1" / 1¼")
Red Sea ReefRun®
10
Installation & Operation
Before installing the pump, dissassemble and reassemble to familiarize
yourself with the component parts.
Select the appropriate place for locating the pump inside your sump
taking care to observe the positioning guidelines shown below.
Red Sea ReefRun®
11
ENG
Assemble the 4 rubber
feet to the bottom of the
pump.
Rotate the pump outlet
chamber to provide
the best direction for
connecting the outlet of
the pump to the inlet of
the aquarium. Thread the
pump cable such that
the cable connector is in
a convenient place for
disconnect / reconnect
when doing pump
maintenance.
Select and assemble the
appropriate hard pipe or
flexible tube connectors
to the outlet of the pump.
If you are using flexible tubing, make sure that it is securely fastened to
the hose barbs with suitable hose clips (not supplied).
Rotate the flow guide so
that the water inlets are
facing the bottom of the
sump.
Note: The ReefRun pumps are supplied with fittings for installing it fully
submerged inside a sump. If you are planning on installing the pump
outside the sump you will need to purchace additional fittings from your
Red Sea dealer.
Read the ReefRun dual controller instructions before operating the pump.
The pump has built in safety features to prevent damage to the pump
in the cases where the pump is not in the water or the impellor cannot
rotate. The ReefRun dual controller automatically shuts the pump down
and enables the pump to be restarted from the controller/App once
the issue has been resolved. After multiple unsuccessful restarts the
pump may need to be disonected from the controller cable for about 30
seconds before it can be restarted.
Red Sea ReefRun®
12
Connecting to the ReefRun Dual Controller
1 2
Control Cable
Pump 1
PSU Pump 1
PSU Pump 2
Control Cable
Pump 2
ReefRun DC
Pump 2
ReefRun DC
Pump 1
Red Sea ReefRun®
13
ENG
Pump Maintenance
For continued smooth running of the ReefRun pumps we recommended
cleaning the pump on a regular basis to remove organic and calcium
carbonate deposits.
Before undertaking maintenance, switch the pump off from the controller
or App and disconnect the pump from the controller cable. Ensure that the
Cable Connector does not fall into the sump.
Remove the pump outlet chamber retainer ring by pulling the tab outwards.
Remove the chamber from the body by rotating and pulling it away from the
pump body.
Pull the complete impellor assembly completely out of the body. Pay attention to
the O-ring that sits between the impellor assembly and the body (Implellor O-ring).
Rinse the impellor assembly and the pump body with water and use a soft brush
to remove deposits. If necessary, soak the impellor assembly and the pump in a
slightly acidic solution (such as diluted vinegar). Remove all rubber parts such as
O-rings and feet before soaking.
When reassembling the pump pay attention to the following:
The impellor O-ring is in place.
The “UP” on the impellor assembly is at the top of the pump.
NOTE: the impellor shaft has a very strong magnet. Hold the impellor rmly when
lowering the impellor shaft into the chamber. Care must be taken not to damage
the ceramic bearing at the bottom of the impellor chamber.
The lower bearing and the tool to remove it are available as a spare part.
Pump outlet chamber O-ring
Impellor O-ring
Red Sea ReefRun®
14
In order to affect this warranty, please contact your local service center.
For your convenience, details of authorized service centers can be found
on Red Sea’s website. Proof of purchase will be required before warranty
performance is rendered.
The sole and exclusive remedy against Red Sea shall be for the repair
or replacement of the Product as provided above. NO OTHER REMEDY
(including but not limited to, incidental or consequential damages for
lost profits, lost sales, or any other incidental or consequential loss) shall
be available. Some jurisdictions do not allow the exclusion of incidental
or consequential damage, so the above limitation may not apply to you.
To the full extent allowed by applicable law, in no event shall Red Sea
be liable for any loss or damage to aquatic life, and/or damage to other
property and/or individuals resulting from the use of the Product or arising
out of any breach of this warranty. All implied warranties are excluded to
the full extent allowed by applicable law, and to the extent that they may
not be excluded, are limited to the applicable warranty period set forth
above. Some jurisdictions do not allow limitations on how long an implied
warranty or condition lasts, so this limitation may not apply to you. The
express warranties made in this warranty are exclusive and may not be
altered, enlarged, or changed by any distributor, dealer, or other person,
whatsoever.
USA
Some states do not allow the exclusion or limitation of incidental or
consequential damages, or limitations on how long an implied warranty
lasts, so the above exclusion or limitations may not apply.
Warranty
Red Sea Products Limited Warranty.
Thank you for purchasing a Red Sea ReefRun DC-Pumps (hereinafter “the
Product”).
Red Sea Aquatics (UK) Ltd. (hereinafter “Red Sea”) warrants the ReefRun DC-
pump motors against manufacturer’s defects in material and workmanship
for 5 years from your date of purchase.
ReefRun DC-pump impellors are a wear item and as such Red Sea warrants
the ReefRun DC-pump impellors against manufacturer’s defects in material
and workmanship for 6 months from your date of purchase.
The warranty provided by Red Sea is NOT TRANSFERABLE AND IS LIMITED
TO THE ORIGINAL PURCHASER. If the Product is eligible under this warranty,
Red Sea will either repair the Product free of charge (not including shipping
costs) with new or refurbished parts or replace the Product with a new or
refurbished Product at Red Sea’s sole discretion.
This warranty DOES NOT COVER normal wear and tear. It also DOES NOT
COVER damage which occurs in shipment and/or failures or defects resulting
from use outside the normal, and/or natural disasters, accidents, power line
surges, neglect, improper installation, operation or maintenance, servicing of
the Product conducted by anyone other than an authorized Red Sea service
center, or failure to use or assemble the Product in accordance with any
instructions provided (in the Product manual or otherwise) or the technical
and/or safety standards of the country in which the Product is used.
Additionally, any modification of the Product other than by an authorized
Red Sea service center will invalidate this warranty.
Red Sea ReefRun®
15
ENG
CE Declaration of Conformity:
The equipment complies with the RF Exposure Requirement 2014/53/
EU, Council Recommendation on the limitation of exposure of the general
public to electromagnetic fields (0-300 GHz). This equipment meets the
following conformance standards: EN 300 328, EN 301 489-17.
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment
is necessary. This product must not be disposed together with the domestic waste. This product must be disposed at an
authorized place for recycling of electrical and electronic appliances. By collecting and recycling waste, you help save natural
resources, and make sure the product is disposed in an environmentally friendly and healthy way.
Red Sea ReefRun®
16
Red Sea ReefRun®
17
CH
用户手册
安静 - 智能 - 强劲
直流智能变频水泵
ReefRun
Red Sea ReefRun®
18
Red Sea ReefRun®
19
CH
内容
简介 ...........................................................................................20
安全事项 .................................................................................21
数据表 ...................................................................................... 22
ReefRun 组件 .......................................................................... 23
安装与操作 ............................................................................ 24
连接到 ReefRun 双联控制器 ............................................... 26
直流智能变频水泵维护 ....................................................... 27
保修 ......................................................................................... 28
Red Sea ReefRun®
20
介绍
恭喜您购买红海的 ReefRun® 直流智能变频水泵。
本手册涵盖直流智能变频水泵的实物安装和维护。
ReefRun直流智能变频水泵只能在连接到ReefRun双联控制器时使
用,该控制器可控制最多2个ReefRun兼容的回水直流智能变频水
泵、直流蛋分或两者的组合。阅读 ReefRun双联控制器随附的手册,
了解控制器的完整安装和操作说明。
ReefRun双联控制器是是红海整套智能设备中的其中一个产品,通过
智能移动设备端的ReefBeat®应用程序连接到Wi-Fi进行操控。
欢迎使用红海珊瑚饲养的智能系统!
红海团队
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Red Sea ReefRun 9000 取扱説明書

タイプ
取扱説明書
このマニュアルも適しています

他の言語で