QNAP QSW-M2116P-2T2S ユーザーガイド

タイプ
ユーザーガイド
QSW-M2116P-2T2S
使用手冊
文件版本: 1
16/10/2023
目錄
1. 重要資訊
安全資訊......................................................................................................................................................................3
2. 產品概觀
關於 QSW-M2116P-2T2S............................................................................................................................................5
硬體規格......................................................................................................................................................................5
包裝內容......................................................................................................................................................................6
元件..............................................................................................................................................................................6
前面板..................................................................................................................................................................... 7
後面板..................................................................................................................................................................... 7
前面板 LED ........................................................................................................................................................ 8
3. 安裝與存取
安裝需求......................................................................................................................................................................9
設定交換器..................................................................................................................................................................9
裝上橡膠腳座..............................................................................................................................................................9
安裝把手....................................................................................................................................................................11
將交換器連接至電腦或網路.................................................................................................................................... 13
將交換器連接至電腦........................................................................................................................................... 13
將交換器連接至網路........................................................................................................................................... 14
交換器存取................................................................................................................................................................14
透過瀏覽器存取交換器....................................................................................................................................... 14
透過 Qnder Pro 存取交換器.............................................................................................................................15
4. 基本操作
重設按鈕....................................................................................................................................................................17
LED 燈號....................................................................................................................................................................17
5. QSS
關於 QSS....................................................................................................................................................................20
開始使用....................................................................................................................................................................20
用戶端裝置管理........................................................................................................................................................20
掃描已連線的裝置............................................................................................................................................... 20
將網路喚醒封包傳送給裝置................................................................................................................................20
刪除 MAC 位址..................................................................................................................................................... 21
清除 MAC 位址歷程記錄..................................................................................................................................... 21
網路管理....................................................................................................................................................................21
編輯連接埠設定................................................................................................................................................... 22
管理 PoE 設定.......................................................................................................................................................22
新增 VLAN.............................................................................................................................................................23
新增連結彙總群組 (LAG)..................................................................................................................................... 24
管理快速跨距樹狀目錄通訊協定 (RSTP) 設定...................................................................................................25
新增靜態 MAC 位址............................................................................................................................................. 26
新增存取控制清單項目....................................................................................................................................... 26
設置 IGMP Snooping...........................................................................................................................................27
編輯 QoS 設定......................................................................................................................................................28
設定 QoS 速率限制.............................................................................................................................................. 28
設定連接埠鏡像................................................................................................................................................... 29
啟用或停用 LLDP................................................................................................................................................. 29
設定迴圈防護....................................................................................................................................................... 30
QSW-M2116P-2T2S 使用手冊
1
系統管理....................................................................................................................................................................30
系統設定...............................................................................................................................................................30
韌體管理...............................................................................................................................................................37
6. 支援和其他資源
7. 詞彙
Qnder Pro............................................................................................................................................................... 41
QSS.............................................................................................................................................................................41
8. 聲明
有限保固....................................................................................................................................................................42
免責聲明....................................................................................................................................................................42
著作權與商標............................................................................................................................................................42
GNU General Public License................................................................................................................................... 42
CE 聲明...................................................................................................................................................................... 50
FCC 聲明.................................................................................................................................................................... 50
VCCI 聲明...................................................................................................................................................................51
BSMI 聲明..................................................................................................................................................................51
SJ/T 11364-2006........................................................................................................................................................51
歐盟廢電子電機設備 (WEEE) 指令 (2002/96/EC)................................................................................................... 52
歐盟 RoHS 聲明........................................................................................................................................................ 52
雷射規範聲明............................................................................................................................................................52
UKCA 聲明.................................................................................................................................................................52
2
1. 重要資訊
原包裝
請保留原包裝及包裝材料。當產品需要退回或送修時請使用原包裝,以免損壞產品。
若因包裝不當導致運送中產品發生之損壞,QNAP 恕不提供退款或保固服務。
硬體瑕疵
如果您的 QNAP 產品有硬體瑕疵,請將產品寄回 QNAP QNAP 授權服務中心進行維修或換貨。只要您或未
經授權的第三方嘗試修復產品或執行產品維修流程,皆會導致產品保固失效。
對於因未獲授權進行修改或安裝不支援之第三方應用程式所導致的任何損害或資料遺失,QNAP 一概不予負
責。
如需詳細資訊,請參見:QNAP 產品保固服務條款
安全資訊
以下指示幫助確保人身安全及環境安全。執行任何操作前,請仔細閱讀本安全指示。
一般指示
裝置應放置在實施進出管制的安全場所,控管方式包括工具、鎖鑰或其他安全機制。
唯有具技能且獲得授權的合格裝置管理員能夠存取裝置;合格裝置管理員必須熟悉所有管制方法、安全
注意事項、安裝及保養程序。
為避免受傷或使元件損壞,在觸碰磁碟及其他內部系統元件前,請先確認其是否已經冷卻。
請遵守靜電放電 (ESD) 程序以防止潛在傷害或元件損壞。
電源
為了降低走火或觸電風險,務必只將電源線連接至正確接地的電源插座。
為防止嚴重傷害事故發生,在安裝或更換系統元件前,經訓練的維修技術人員必須先從裝置上拔除所有
電源供應器的電源線。。
系統電池
本產品包含鈕扣電池。
如果吞下鈕扣型鋰電池可能會在 2 小時內造成嚴重或致命的傷害。
請將電池放在兒童接觸不到的地方。
如果您認為電池可能已被吞下或位於身體的任何部位,請立即就醫。
更換電池時,請務必使用相同類型的電池,以免電池爆炸造成受傷或使元件損壞。
請遵照當地法規或電池製造商的指示妥善處置廢棄電池。
QSW-M2116P-2T2S 使用手冊
重要資訊 3
移動的零件
轉動的風扇葉片:裝置接上電源時,請使身體部位遠離正在轉動的風扇葉片。
移動的元件:使身體部位遠離正在移動的其他元件。
該裝置不適合在兒童可能出現的地方使用。
QSW-M2116P-2T2S 使用手冊
重要資訊 4
2. 產品概觀
本章介紹 QNAP QSW-M2116P-2T2S 交換器的基本資訊。
關於 QSW-M2116P-2T2S
QNAP QSW-M2116P-2T2S 是專為 PoE 網路設計的網管交換器。這款交換器具有 16 2.5 GbE PoE+ 連接埠、2
10 GbE PoE++ 連接埠,能夠提供高速和高功率連線。其功率總預算為 280 瓦,並包括兩個額外的 10 GbE
SFP+ 連接埠,可輕鬆擴充網路。QSS 介面可讓使用者和 IT 管理員輕鬆管理第 2 層網路功能和 PoE 設定。
硬體規格
提示
型號規格如有變更,恕不另行通知。若要查看最新規格,請前往:https://www.qnap.com
元件 QSW-M2116P-2T2S
處理器
CPU Microchip VSC7448-02
晶片組
記憶體 4 GB
網路介面 16 x 2.5G/1G RJ45 連接埠
2 x 10G/5G/1G SFP+ 連接埠
2 x 10G/5G/1G BASE-T RJ45 連接埠
管理介面 1 x 1 GbE 管理連接埠
PoE 支援
802.3af (PoE) 連接埠 1 16
注意
這些連接埠支援 IEEE 802.3af-2003 PoE 標準並可提供達
15.4 W 電源。
802.3at (PoE+) 連接埠 1 16
注意
這些連接埠支援 IEEE 802.3at-2009 PoE 標準並可提供達
30 W DC 電源。
802.3bt (PoE++) 連接埠 19 20
注意
這些連接埠支援 IEEE 802.3bt-2018 PoE 標準並可提供達
90 W DC 電源。
PoE 最高電源埠 連接埠 1 16:最高 30 W
連接埠 19 20:最高 90 W
PoE 功率總預算 280 W
Interface(介面)
按鈕 交換器重設
LED 燈號
QSW-M2116P-2T2S 使用手冊
產品概觀 5
元件 QSW-M2116P-2T2S
系統 狀態
• PoE
風扇
連接埠 連結
速度
• PoE
尺寸
外觀規格 1U 機架式
尺寸 ( x x ) 43.5 x 285 x 234.8 mm
(1.71 x 11.22 x 9.24 in)
淨重 2.08 kg (4.59 lbs)
其他
電源供應器 100-240V50/60 Hz
最大耗電量 350 W
風扇 系統:2 x PWM 雙軸承風扇
操作溫度 0˚C 40˚C (32˚F 104˚F)
相對溼度 不凝結相對溼度:5% 95%
溼球溫度:27˚C (80.6˚F)
安全插槽 Kensington 安全插槽
包裝內容
項目 數量
QSW-M2116P-2T2S 1
電源線 1
滑軌支架 2
滑軌支架螺絲 6
橡膠腳座 4
快速安裝手冊 (QIG) 1
元件
QSW-M2116P-2T2S 使用手冊
產品概觀 6
前面板
編號 元件 編號 元件
1重設按鈕 3 10 Gigabit 乙太網路 (SFP+) 連接埠
2 2.5 Gigabit (RJ45) 802.3af PoE/802.3at
PoE+ 連接埠
4 10 Gigabit (RJ45) 802.3bt PoE++ 連接埠
後面板
編號 元件 編號 元件
1電源輸入 3 Kensington 安全插槽
2管理連接埠 - -
QSW-M2116P-2T2S 使用手冊
產品概觀 7
前面板 LED
編號 元件 編號 元件
1系統狀態 LED 6 10 Gigabit SFP+ 10G 速度 LED
2 PoE LED 7 10 Gigabit SFP+ 1G 速度 LED
3風扇 LED 8 2.5 Gigabit RJ45 連結 LED
4 2.5 Gigabit 乙太網路 (SFP+) 連結 LED 9 2.5 Gigabit RJ45 PoE++ LED
5 2.5 Gigabit 乙太網路 (SFP+) PoE LED - -
QSW-M2116P-2T2S 使用手冊
產品概觀 8
3. 安裝與存取
本章說明特定硬體安裝與交換器存取步驟。
安裝需求
類別 項目
環境 室溫:0˚C 40˚C (32˚F 104˚F)
不凝結相對溼度:5% 95%
溼球溫度:27˚C (80.6˚F)
平坦且防靜電的表面,不受陽光直射,亦不與液體或化學物質接觸
確認沒有物體會阻礙裝置的通風口,或者對裝置或電源線產生壓力
硬體和週邊設備 電腦或 NAS
網路線
工具 1 號或 2 號十字螺絲起子
平頭螺絲起子
防靜電腕帶
設定交換器
1. 將交換器置於符合需求的環境。
如需詳細資訊,請參見:安裝需求
2. 打開交換器電源。
3. 連接交換器至電腦或網路。
如需詳細資訊,請參見:將交換器連接至電腦或網路
4. 登入 QSS
裝上橡膠腳座
1. 關閉裝置電源。
2. 從電源插座拔下電源線。
3. 中斷所有連接線和外接裝置的連線。
4. 將裝置上下翻轉。
QSW-M2116P-2T2S 使用手冊
安裝與存取 9
5. 裝上橡膠腳座。
a. 將橡膠腳座的保護膜取下。
b. 裝上橡膠腳座。
c. 將裝置正常直立。
QSW-M2116P-2T2S 使用手冊
安裝與存取 10
6. 連上所有連接線和外接裝置。
7. 將電源線連接至電源插座。
8. 開啟裝置電源。
安裝把手
安裝把手即可輕鬆且穩固地拿取機架上的裝置。
1. 關閉裝置電源。
2. 從電源插座拔下電源線。
3. 中斷所有連接線和外接裝置的連線。
4. 將把手安裝到角形托座上。
a. 將把手開口對齊至角形托座上的兩個圓頭螺絲洞。
b. 鎖上螺絲,將把手鎖定在角形托座上。
QSW-M2116P-2T2S 使用手冊
安裝與存取 11
5. 在裝置上安裝角形托座。
a. 將角形托座上的孔洞對齊機殼上的孔洞。
注意
請確定把手與前面板面對相同的方向。
b. 鎖上螺絲,將角形托座鎖定在機殼上。
6. 在機殼的另一側安裝第二個把手。
7. 連上所有連接線和外接裝置。
8. 將電源線插入電源插座。
9. 開啟裝置電源。
QSW-M2116P-2T2S 使用手冊
安裝與存取 12
將交換器連接至電腦或網路
您可將交換器連接至電腦或區域網路。如需詳細資訊,請參見下列主題:
將交換器連接至電腦
將交換器連接至網路
將交換器連接至電腦
您可透過將網路線連接交換器的管理連接埠,將交換器連接 QNAP NAS,來擴充儲存容量並將資料備份至另一
NAS。但是您必須將交換器連接至電腦來編輯設定。
1. 打開交換器電源。
2. 連接交換器至電腦。
a. 將網路線連接至交換器上的管理連接埠或 PoE 連接埠。
b. 將網路線連接至電腦上的 Gigabit 網路連接埠。
c. 選擇性: 將交換器連接到 NAS
3. 確認電腦可辨識交換器。
a. 在主機電腦中開啟 Qnder Pro
注意
若要下載 Qnder Pro,請前往:https://www.qnap.com/utilities
QSW-M2116P-2T2S 使用手冊
安裝與存取 13
b. 從清單中尋找交換器。
將交換器連接至網路
您可透過管理連接埠或 PoE 連接埠,將交換器連接至區域網路。
1. 打開交換器電源。
2. 利用管理連接埠或 PoE 連接埠,將交換器至區域網路。
3. 在連接相同區域網路的電腦上執行 Qnder Pro
注意
若要下載 Qnder Pro,請前往:https://www.qnap.com/utilities
4. 在清單中找到交換器,然後在名稱或 IP 位址上按兩下。
QSS 登入畫面隨即出現。
5. 輸入 QSS 登入資訊。
6. 按一下[登入]
交換器存取
方式 說明 需求
網頁瀏覽器 如果具備下列資訊,就可以使用相同網路內的
任何電腦來存取交換器:
交換器名稱 (例如:http://example123/)
IP 位址
登入有效使用者帳戶的認證資料
如需詳細資訊,請參見:透過瀏覽器存取交換
與交換器連接相同網路的電腦
網頁瀏覽器
Qnder Pro Qnder Pro 是一款桌面應用工具,可讓使用
者定位和存取特定網路內的 QNAP 裝置。此應
用工具支援 WindowsmacOSLinux
Chrome OS
如需詳細資訊,請參見:透過 Qnder Pro
取交換器
與交換器連接相同網路的電腦
網頁瀏覽器
Qnder Pro
透過瀏覽器存取交換器
如果您知道交換器的 IP 位址以及有效使用者帳戶的登入認證資料,就可以從網路上的任何電腦來存取交換
器。QNAP 交換器預設支援 DHCP 客戶端設定進行 IP 分配。連線至網路時,交換器將自動保留來自 DHCP
服器的 IP 位址。
注意
如果您不知道交換器的 IP 位址,則可使用 Qnder Pro 尋找交換器。
如果交換器未連接 DHCP 支援的網路,則可透過將電腦的 IP 位址變更為
169.254.100.102 來存取交換器網頁介面。
交換器的預設 IP 位址為 169.254.100.101
QSW-M2116P-2T2S 使用手冊
安裝與存取 14
1. 請確認您的電腦與交換器連線到相同的網路。
2. 開啟電腦的網頁瀏覽器。
3. 在網址列中輸入交換器的 IP 位址。
QSS 登入畫面隨即顯示。
4. 設定使用者名稱與密碼。
預設使用者名稱 預設密碼
admin 交換器映像的 MAC 位址,請刪去所有標點符號,並將所有字母大寫。
提示
例如,如果 MAC 位址為 00:0a:0b:0c:00:01,預設密碼則為
000A0B0C0001
注意
您可透過 Qnder Pro 或者裝置標籤標示「MAC」處,找
到裝置 MAC 位址。
系統將會提示您在首次登入後更改密碼。
出於安全考慮,QNAP 強烈建議您在首次登入之後變更密
碼。
5. 按一下[登入]
QSS 桌面隨即顯示。
重要
在設定交換器後,確保將電腦的 IP 位址更改為原始設定。
透過 Qnder Pro 存取交換器
1. 在與交換器連接到相同網路的電腦上安裝 Qnder Pro
提示
若要下載 Qnder Pro,請前往:https://www.qnap.com/en/utilities
2. 開啟 Qnder Pro
Qnder Pro 會自動搜尋網路內的所有 QNAP 裝置。
3. 在清單中找到交換器,然後在名稱或 IP 位址上按兩下。
QSS 登入畫面隨即在預設網頁瀏覽器中開啟。
4. 設定使用者名稱與密碼。
QSW-M2116P-2T2S 使用手冊
安裝與存取 15
預設使用者名稱 預設密碼
admin 交換器映像的 MAC 位址,請刪去所有標點符號,並將所有字母大寫。
提示
例如,如果 MAC 位址為 00:0a:0b:0c:00:01,預設密碼則為
000A0B0C0001
注意
您可透過 Qnder Pro 或者裝置標籤標示「MAC」處,找
到裝置 MAC 位址。
系統將會提示您在首次登入後更改密碼。
出於安全考慮,QNAP 強烈建議您在首次登入之後變更密
碼。
5. 按一下[登入]
QSS 桌面隨即顯示。
QSW-M2116P-2T2S 使用手冊
安裝與存取 16
4. 基本操作
本章介紹交換器的基本操作。
重設按鈕
操作 使用者動作 結果
系統基本重設 按住按鈕 5 秒。 以下設定將回復至預設值:
系統管理員密碼:預設密碼為裝置 MAC 位址的大寫
字母,且不包含特殊字元。例如,若裝置 MAC 位址
00-08-9B-F6-15-75,則 admin 密碼為
00089BF61575
注意
您可透過 Qnder Pro 或者裝置標籤標示
MAC」處,找到裝置 MAC 位址。
系統會自動啟用 admin 帳戶
系統進階重設 按住按鈕 10 秒。 回復為出廠預設值。
LED 燈號
LED 燈號指示交換器開機時的系統狀態與相關資訊。下列 LED 燈號資訊僅適用於交換器已連接至網路的情況。
如需 LED 燈號的位置資訊,請參見:前面板 LED
系統狀態 LED
狀態 說明
綠燈 裝置就緒。
韌體已更新。
密碼已重設。
裝置已重設為出廠預設設定。
綠燈閃爍 裝置正在初始化。
韌體正在更新。
重要
請勿在韌體更新期間拔下電源線,也不要強制結束應用
程式。
裝置正在重設中。
裝置密碼正在重設。
QSW-M2116P-2T2S 使用手冊
基本操作 17
狀態 說明
紅燈 發生系統錯誤。
偵測到網路迴圈。
系統過熱
風扇發生錯誤。
注意
如需詳細資訊,請登入至 QSS
熄滅 裝置已關機。
裝置已準備好重設密碼。
裝置已準備好恢復出廠設定。
PoE LED
狀態 說明
綠燈 PoE 狀態正常。
紅燈 PoE 發生嚴重錯誤。
風扇 LED
狀態 說明
綠燈 系統風扇狀態正常。
紅燈 系統風扇發生嚴重錯誤。
2.5 Gigabit 乙太網路 (RJ45) 連結 LED - 左側
狀態 說明
綠燈 網路執行速度為 2.5 Gbps
綠燈閃爍 資料傳送中。
琥珀色燈 網路執行速度為 1 Gbps 100 Mbps
琥珀色燈閃爍 資料傳送中。
熄滅 電纜沒有連接至連接埠。
連接埠在 QSS 被停用。
偵測到網路迴圈,迴圈防護已停用連接埠。
2.5 Gigabit 乙太網路 (RJ45) PoE LED - 右側
狀態 說明
綠燈 交換器已連接至電源裝置。
綠燈閃爍 電源裝置發生錯誤。
熄滅 沒有電源裝置連接至連接埠。
QSS 中,已針對這個連接埠停用 PoE 模式。
QSW-M2116P-2T2S 使用手冊
基本操作 18
10 Gigabit 乙太網路 (SFP+) 10G 速度 LED - 左側
狀態 說明
綠燈 網路執行速度為 10 Gbps
綠燈閃爍 資料傳送中。
熄滅 電纜沒有連接至連接埠。
連接埠在 QSS 被停用。
偵測到網路迴圈,迴圈防護已停用連接埠。
10 Gigabit 乙太網路 (SFP+) 1G 速度 LED - 右側
狀態 說明
琥珀色燈 網路執行速度為 1 Gbps
琥珀色燈閃爍 資料傳送中。
熄滅 電纜沒有連接至連接埠。
連接埠在 QSS 被停用。
偵測到網路迴圈,迴圈防護已停用連接埠。
10 Gigabit 乙太網路 (RJ45) 連結 LED - 左側
狀態 說明
綠燈 網路執行速度低於 10 Gbps
綠燈閃爍 資料傳送中。
琥珀色燈 網路執行速度為 5 Gbps2.5 Gbps1 Gbps 100 Mbps
琥珀色燈閃爍 資料傳送中。
熄滅 電纜沒有連接至連接埠。
連接埠在 QSS 被停用。
偵測到網路迴圈,迴圈防護已停用連接埠。
10 Gigabit 乙太網路 (RJ45) PoE LED - 右側
狀態 說明
綠燈 交換器已連接至電源裝置。
綠燈閃爍 電源裝置發生錯誤。
熄滅 沒有電源裝置連接至連接埠。
QSS 中,已針對這個連接埠停用 PoE 模式。
QSW-M2116P-2T2S 使用手冊
基本操作 19
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53

QNAP QSW-M2116P-2T2S ユーザーガイド

タイプ
ユーザーガイド

他の言語で