90°
90°
I
II
0
POWER
AUT
Ø 4 ... 8mm
PROG
OK
AUT
READY
TEST ON LOAD
TEST OFF LOAD
ATyS g
Un
Auto Conf
5
1
10
14
5
1
10
13
0
1
5
10
20
60
0
1
5
10
20
60
G:
H:
E:
F:
REMOTE CONTROL
A: 3 Ph
B: 1 Ph
C: Neutral
D: Neutral
ATyS
Un N°
PP / PN
1: 220 / 127
2: 380 / 220
3: 400 / 230
4: 415 / 240
5: 480 / 277
6: 208 / 120
7: 220 / 127
8: 230 / 132
9: 240 / 138
10: 380 / 220
11: 400 / 230
12: 415 / 240
13: 480 / 277
5
6
7
8
9
10
11
12
13
14
15
16
18
20
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
3
3
4
4
5
5
6
6
7
7
8
8
9
10
N°: Δ
U
Δ
F
%
XXX
50 Hz60 Hz
XXXXXXXX
Motorised Changeover Switch
1600A Ref : 95054160
1
2
3x
Ø 4-8 mm
DPS
POWER
AUT
Ø 4 ... 8mm
POWER
AUT
Ø 4 ... 8mm
POWER
AUT
Ø 4 ... 8mm
AUT
ESC
Lamp
Test
TEST ON LOAD
LOCAL / REMOTE CTRL
MODE
TEST OFF LOAD
READY
ATYS d
ATYS g
ATYS t
Etiquette sur appareil de coupure
convenant aux formats B3 tri à B8 tétra
Exemple de contenu similaire aux véritables
indications avec la norme UL1008
Marquage montrant à l’opérateur
les emplacements de collage
des étiquettes de CONTROL et de OUTPUTS
Etiquette vierge pour
d’autres marques que Socomec
et applications autres que l’ATyS
Etiquette vierge pour masquer
l’accessibilité à un connecteur
non utilisé par le client
Exemple de kit étiquettes
Etiquettes pour le DPS
Exemple de kit étiquettes vierge
ATYS p
POWER
AUT
Ø 4 ... 8mm
ATYS
POWER
AUT
Ø 4 ... 8mm
ATyS p
PROG
OK
AUT
READY
REMOTE CONTROL
ATyS t
E:
F:
0
1
5
10
20
60
0
1
5
10
20
60
A: 3 Ph
B: 1 Ph
C: Neutral
D: Neutral
PROG
OK
AUT
READY
TEST ON LOAD
TEST OFF LOAD
ATyS g
Un
Auto Conf
5
1
10
14
5
1
10
13
0
1
5
10
20
60
0
1
5
10
20
60
G:
H:
E:
F:
ON LOAD
ESC
OFF LOAD
LAMP
MODE
ATyS D20 ATyS D10
P87_marquages_L.pdf 19/11/2012
Face avant PC
REMOTE CONTROL
ATyS d
G: U 10% F 5%
H: U 20% F 10%
A: 3 Ph
B: 1 Ph
C: Neutral
D: Neutral
To ATyS D10
PROG
FAULT
ON ON
ON
TESTCONTROL
AUT
ON ON
FAULTON
AUT
202 -
L
102 -
N
101 -
L
Aux 1
Aux 2
(208-277V +/-20%)
Motorised Changeover Switch
ATyS
1600A Ref : 95054160
Un N° PP / PN
1: 220 / 127
2: 380 / 220
3: 400 / 230
4: 415 / 240
5: 480 / 277
6: 208 / 120
7: 220 / 127
8: 230 / 132
9: 240 / 138
10: 380 / 220
11: 400 / 230
12: 415 / 240
13: 480 / 277
5
6
7
8
9
10
11
12
13
14
15
16
18
20
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
3
3
4
4
5
5
6
6
7
7
8
8
9
10
N°: Δ
U ΔF %
XXX
50 Hz60 Hz
XXXXXXXX
Motorised Changeover Switch
ATyS
1600A Ref : 95054160
XXX
XXXXXXXX
Motorised Changeover Switch
ATyS
1600A Ref : 95054160
XXX
XXXXXXXX
13142464A63A
ATyS
AVAIL.
OUTPUTS
04
2A / 250V
2A / 24V
C
317315314313312
CONTROL
316
C
Enable
Ctrl
OFF
XXXXXXX
301 302
L N
Aux Supply
230V
(208-277V +/-20%)
Motorised Changeover Switch
ATyS
1600A Ref : 95054160
Un N° PP / PN
1: 220 / 127
2: 380 / 220
3: 400 / 230
4: 415 / 240
5: 480 / 277
6: 208 / 120
7: 220 / 127
8: 230 / 132
9: 240 / 138
10: 380 / 220
11: 400 / 230
12: 415 / 240
13: 480 / 277
5
6
7
8
9
10
11
12
13
14
15
16
18
20
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
3
3
4
4
5
5
6
6
7
7
8
8
9
10
N°: Δ
U ΔF %
XXX
50 Hz60 Hz
XXXXXXXX
NON-AUTOMATIC
TRANSFER SWITCH
3PSF
Suitable for control of motors, electric discharge lamps, tungsten filament lamps, and electric heating equipment
where the sum of motor full-load ampere ratings and the ampere ratings of other loads do not exceed the total system
ampere rating of the switch and the tungsten load does not exceed 30 percent of the total system switch rating.
When protected by a circuit breaker without adjustable short-time response
only or by fuses, this transfer switch is rated for use on a circuit capable
of delivering not more than 14kA rms symmetrical, 600 volts maximum.
When protected by 600 ampere maximum Class J Fuse,this transfer
switch is rated for use on a circuit capable of delivering not more
than 65 kA rms symmetrical amperes, 600 volts maximum.
UL1008
Va.c. 50/60Hz
1ph
Total system
Resistance only
200
240 480 600
200 200 /
400
400
400
400
3ph
3ph
3ph
2A3 2A5 2A72A1
2A4 2A6 2A82A2
1A3 1A5 1A71A1
1A4 1A6 1A81A2
Use 75°C wire
Instructions sheet : IS 537501
Use Copper or Aluminium wire
Use of listed (ZMVV) terminal lugs:
- CMC, LA 630-R Terminal tightening
torque: 310lb.in.
- PANDUIT, LAM2A 350 Terminal
tightening torque: 398lb.in.
ATyS Ref.: 88888888800A
code à barres
Motorised Changeover Switch
ATyS
1600A Ref : 95054160
DPS
POWER
AUT
Ø 4 ... 8mm
POWER
AUT
Ø 4 ... 8mm
POWER
AUT
Ø 4 ... 8mm
AUT
ESC
Lamp
Test
TEST ON LOAD
LOCAL / REMOTE CTRL
MODE
TEST OFF LOAD
READY
ATYS d
ATYS g
ATYS t
Etiquette sur appareil de coupure
convenant aux formats B3 tri à B8 tétra
Exemple de contenu similaire aux véritables
indications avec la norme UL1008
Marquage montrant à l’opérateur
les emplacements de collage
des étiquettes de CONTROL et de OUTPUTS
Etiquette vierge pour
d’autres marques que Socomec
et applications autres que l’ATyS
Etiquette vierge pour masquer
l’accessibilité à un connecteur
non utilisé par le client
Exemple de kit étiquettes
Etiquettes pour le DPS
Exemple de kit étiquettes vierge
ATYS p
POWER
AUT
Ø 4 ... 8mm
ATYS
POWER
AUT
Ø 4 ... 8mm
ATyS p
PROG
OK
AUT
READY
REMOTE CONTROL
ATyS t
E:
F:
0
1
5
10
20
60
0
1
5
10
20
60
A: 3 Ph
B: 1 Ph
C: Neutral
D: Neutral
PROG
OK
AUT
READY
TEST ON LOAD
TEST OFF LOAD
ATyS g
Un
Auto Conf
5
1
10
14
5
1
10
13
0
1
5
10
20
60
0
1
5
10
20
60
G:
H:
E:
F:
ON LOAD
ESC
OFF LOAD
LAMP
MODE
ATyS D20 ATyS D10
P87_marquages_L.pdf 19/11/2012
Face avant PC
REMOTE CONTROL
ATyS d
G: U 10% F 5%
H: U 20% F 10%
A: 3 Ph
B: 1 Ph
C: Neutral
D: Neutral
To ATyS D10
PROG
FAU LT
ON ON
ON
TESTCONTROL
AUT
ON ON
FAU LTON
AUT
202 -
L
201 -
N
101 -
L
Aux Supply 230V
Aux 1
Aux 2
(208-277V +/-20%)
Motorised Changeover Switch
ATyS
1600A Ref : 95054160
Un N° PP / PN
1: 220 / 127
2: 380 / 220
3: 400 / 230
4: 415 / 240
5: 480 / 277
6: 208 / 120
7: 220 / 127
8: 230 / 132
9: 240 / 138
10: 380 / 220
11: 400 / 230
12: 415 / 240
13: 480 / 277
5
6
7
8
9
10
11
12
13
14
15
16
18
20
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
3
3
4
4
5
5
6
6
7
7
8
8
9
10
N°: Δ
U ΔF %
XXX
50 Hz60 Hz
XXXXXXXX
Motorised Changeover Switch
ATyS
1600A Ref : 95054160
XXX
XXXXXXXX
Motorised Changeover Switch
ATyS
1600A Ref : 95054160
XXX
XXXXXXXX
13142464A63A
ATyS
AVAIL.
OUTPUTS
04
2A / 250V
2A / 24V
C
317315314313312
CONTROL
316
C
Enable
Ctrl
OFF
XXXXXXX
301 302
L N
Aux Supply
230V
(208-277V +/-20%)
Motorised Changeover Switch
ATyS
1600A Ref : 95054160
Un N° PP / PN
1: 220 / 127
2: 380 / 220
3: 400 / 230
4: 415 / 240
5: 480 / 277
6: 208 / 120
7: 220 / 127
8: 230 / 132
9: 240 / 138
10: 380 / 220
11: 400 / 230
12: 415 / 240
13: 480 / 277
5
6
7
8
9
10
11
12
13
14
15
16
18
20
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
3
3
4
4
5
5
6
6
7
7
8
8
9
10
N°: Δ
U ΔF %
XXX
50 Hz60 Hz
XXXXXXXX
NON-AUTOMATIC
TRANSFER SWITCH
3PSF
Suitable for control of motors, electric discharge lamps, tungsten filament lamps, and electric heating equipment
where the sum of motor full-load ampere ratings and the ampere ratings of other loads do not exceed the total system
ampere rating of the switch and the tungsten load does not exceed 30 percent of the total system switch rating.
When protected by a circuit breaker without adjustable short-time response
only or by fuses, this transfer switch is rated for use on a circuit capable
of delivering not more than 14kA rms symmetrical, 600 volts maximum.
When protected by 600 ampere maximum Class J Fuse,this transfer
switch is rated for use on a circuit capable of delivering not more
than 65 kA rms symmetrical amperes, 600 volts maximum.
UL1008
Va.c. 50/60Hz
1ph
Total system
Resistance only
200
240 480 600
200 200 /
400
400
400
400
3ph
3ph
3ph
2A3 2A5 2A72A1
2A4 2A6 2A82A2
1A3 1A5 1A71A1
1A4 1A6 1A81A2
Use 75°C wire
Instructions sheet : IS 537501
Use Copper or Aluminium wire
Use of listed (ZMVV) terminal lugs:
- CMC, LA 630-R Terminal tightening
torque: 310lb.in.
- PANDUIT, LAM2A 350 Terminal
tightening torque: 398lb.in.
ATyS Ref.: 88888888800A
code à barres
Motorised Changeover Switch
ATyS
1600A Ref : 95054160
DPS
POWER
AUT
Ø 4 ... 8mm
POWER
AUT
Ø 4 ... 8mm
POWER
AUT
Ø 4 ... 8mm
AUT
ESC
Lamp
Test
TEST ON LOAD
LOCAL / REMOTE CTRL
MODE
TEST OFF LOAD
READY
ATYS d
ATYS g
ATYS t
Etiquette sur appareil de coupure
convenant aux formats B3 tri à B8 tétra
Exemple de contenu similaire aux véritables
indications avec la norme UL1008
Marquage montrant à l’opérateur
les emplacements de collage
des étiquettes de CONTROL et de OUTPUTS
Etiquette vierge pour
d’autres marques que Socomec
et applications autres que l’ATyS
Etiquette vierge pour masquer
l’accessibilité à un connecteur
non utilisé par le client
Exemple de kit étiquettes
Etiquettes pour le DPS
Exemple de kit étiquettes vierge
ATYS p
POWER
AUT
Ø 4 ... 8mm
ATYS
POWER
AUT
Ø 4 ... 8mm
ATyS p
PROG
OK
AUT
READY
REMOTE CONTROL
ATyS t
E:
F:
0
1
5
10
20
60
0
1
5
10
20
60
A: 3 Ph
B: 1 Ph
C: Neutral
D: Neutral
PROG
OK
AUT
READY
TEST ON LOAD
TEST OFF LOAD
ATyS g
Un
Auto Conf
5
1
10
14
5
1
10
13
0
1
5
10
20
60
0
1
5
10
20
60
G:
H:
E:
F:
ON LOAD
ESC
OFF LOAD
LAMP
MODE
ATyS D20 ATyS D10
P87_marquages_L.pdf 19/11/2012
Face avant PC
REMOTE CONTROL
ATyS d
G: U 10% F 5%
H: U 20% F 10%
A: 3 Ph
B: 1 Ph
C: Neutral
D: Neutral
To ATyS D10
PROG
FAULT
ON ON
ON
TESTCONTROL
AUT
ON ON
FAULTON
AUT
202 - L102 - N
201 - N101 - L
Aux Supply 230V
Aux 1 Aux 2
(208-277V +/-20%)
Motorised Changeover Switch
ATyS
1600A Ref : 95054160
Un N° PP / PN
1: 220 / 127
2: 380 / 220
3: 400 / 230
4: 415 / 240
5: 480 / 277
6: 208 / 120
7: 220 / 127
8: 230 / 132
9: 240 / 138
10: 380 / 220
11: 400 / 230
12: 415 / 240
13: 480 / 277
5
6
7
8
9
10
11
12
13
14
15
16
18
20
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
3
3
4
4
5
5
6
6
7
7
8
8
9
10
N°: Δ
U ΔF %
XXX
50 Hz60 Hz
XXXXXXXX
Motorised Changeover Switch
ATyS
1600A Ref : 95054160
XXX
XXXXXXXX
Motorised Changeover Switch
ATyS
1600A Ref : 95054160
XXX
XXXXXXXX
13142464A63A
ATyS
AVAIL.
OUTPUTS
04
2A / 250V
2A / 24V
C
317315314313312
CONTROL
316
C
Enable
Ctrl
OFF
XXXXXXX
301 302
L N
Aux Supply
230V
(208-277V +/-20%)
Motorised Changeover Switch
ATyS
1600A Ref : 95054160
Un N° PP / PN
1: 220 / 127
2: 380 / 220
3: 400 / 230
4: 415 / 240
5: 480 / 277
6: 208 / 120
7: 220 / 127
8: 230 / 132
9: 240 / 138
10: 380 / 220
11: 400 / 230
12: 415 / 240
13: 480 / 277
5
6
7
8
9
10
11
12
13
14
15
16
18
20
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
3
3
4
4
5
5
6
6
7
7
8
8
9
10
N°: Δ
U ΔF %
XXX
50 Hz60 Hz
XXXXXXXX
NON-AUTOMATIC
TRANSFER SWITCH
3PSF
Suitable for control of motors, electric discharge lamps, tungsten filament lamps, and electric heating equipment
where the sum of motor full-load ampere ratings and the ampere ratings of other loads do not exceed the total system
ampere rating of the switch and the tungsten load does not exceed 30 percent of the total system switch rating.
When protected by a circuit breaker without adjustable short-time response
only or by fuses, this transfer switch is rated for use on a circuit capable
of delivering not more than 14kA rms symmetrical, 600 volts maximum.
When protected by 600 ampere maximum Class J Fuse,this transfer
switch is rated for use on a circuit capable of delivering not more
than 65 kA rms symmetrical amperes, 600 volts maximum.
UL1008
Va.c. 50/60Hz
1ph
Total system
Resistance only
200
240 480 600
200 200 /
400
400
400
400
3ph
3ph
3ph
2A3 2A5 2A72A1
2A4 2A6 2A82A2
1A3 1A5 1A71A1
1A4 1A6 1A81A2
Use 75°C wire
Instructions sheet : IS 537501
Use Copper or Aluminium wire
Use of listed (ZMVV) terminal lugs:
- CMC, LA 630-R Terminal tightening
torque: 310lb.in.
- PANDUIT, LAM2A 350 Terminal
tightening torque: 398lb.in.
ATyS Ref.: 88888888800A
code à barres
Motorised Changeover Switch
ATyS
1600A Ref : 95054160
1
2
201 202
312313 314315 316317 63A64A 24 14 04 13
CONTROL OUTPUTS
RJ
101
Aux. 1
Aux. 2
102
800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A
3 P 4 P 3 P 4 P 3 P 4 P 3 P 4 P 3 P 4 P 3 P 4 P 3 P 4 P
in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
C
15.39 391 15.39 391 15.39 391 15.39 391 15.39 391 15.39 391 15.39 391 15.39 391 523 20.59 523 20.59 523 20.59 523 20.59 523 20.59 523 20.59
F
19.84 504 22.99 584 19.84 504 22.99 584 19.84 504 22.99 584 23.46 596 28.19 716 23.46 596 28.19 716 23.46 596 28.19 716 23.46 596 28.19 716
M
10.04 255 13.19 335 10.04 255 13.19 335 10.04 255 13.19 335 13.66 347 18.39 467 13.66 347 18.39 467 13.66 347 18.39 467 13.66 347 18.39 467
T
3.15 80 3.15 80 3.15 80 3.15 80 3.15 80 3.15 80 4.72 120 4.72 120 4.72 120 4.72 120 4.72 120 4.72 120 4.72 120 4.72 120
X
1.87 47.5 1.87 47.5 1.87 47.5 1.87 47.5 1.87 47.5 1.87 47.5 2.09 53 2.09 53 2.11 53,5 2.11 53,5 2.11 53,5 2.11 53,5 2.11 53,5 2.11 53,5
5.43
138
8.43
214
X
T
Fix. M
F
C
C
Fix. 9.84
250
11.02
280
11.02
280
0.83
21
0.83
21
0.35
9
0.49
12.5
0.33
8,5
0.62
15,75
0.62
15,75
0.20
5
0.20
5
0.63x0.43
16x11
ø 0.35
ø 9
ø 0.59
ø 15
0.59
15
ø 0.49
ø 12,5
0.59
15
1.12
28,5
1.12
28,5
0.33
8,5
1.97
50
2.36
60
3.54
90
1.30
33
1.18
30
1.18
30
1.77
45
1.77
45
0.98
25
0.98
25
1.30
33
0.39
10
800 A - 1000 A
2000 A - 3200 A
800 A - 1600 A
1250 A
1600 A -
3200 A
步骤 6A
自动操作
CORPORATE HQ CONTACT: SOCOMEC SAS 1-4 RUE DE WESTHOUSE - 67235 BENFELD, FRANCE - WWW.SOCOMEC.COM
步骤 3
尺寸以毫米表示。
in./mm.
非合同文档。
如有更改,恕不另行通知。
手动操作
步骤 6B
确保产品处于手动模式。
控制/指令终端
步骤 6C
挂锁模式
(标准状态:位置 O)
Imp. ≥60ms 保持
要启用控制,闭合触点 312 与触点 317。
要将产品强制置于 0 位/OFF(关闭),桥接
触点 313 与 317。
对于接触器逻辑,桥接触点 316 与 317。
要手动操作:根据所需要的位置闭合触点。
确保产品中未插入紧急手柄,并且
将模式选择开关转到 AUT 位置。
绿色Power(上电)LED:ON(开)
Manual/Default(手动/默认)
LED:OFF(关)
接触逻辑脉冲逻辑
命令 I
位置 I
命令 0
位置 0
命令 II
位置 II
RJ45 直通电缆
(最长 3 m)。
远程显示器
ATyS D10
步骤 5
检查
在手动模式下检查接线。如果情况正常,
则为产品上电。
绿色Power(上电)LED:ON(开)
绿色 Source(电源)LED:亮起(
I
/
II
或
I
II
)
红色Manuel/Defaut(手动/默认)LED(产品不可用):ON(开)
双电源端子
步骤 4
ATyS电压检测和电源套件,无需
使用F1和F2保险丝
使用横截面积 1.5 至 2.5 mm
2
的电
缆连接产品。
M3 螺钉 - 紧固扭矩:
最小值:0.5 Nm - 最大值:0.6 Nm
最小值:4.43 lbin - 最大值:5.31 lbin