KDK 3512UA 取扱説明書

タイプ
取扱説明書
Model No.
型号:
Thank you for purchasing this KDK product.
Please read these installation and operating instructions carefully before attempting to
install, operate or service the KDK product.Please carefully read the“Installation
cautions”P.2 3of this installation and operating instructions before installation.
Failure to comply with installation and operating instructions could result in personal
injury or property damage.Please explain to users how to operation and maintain the
product after installation, and this booklet should be presented to users.
Please retain this booklet for future reference.
感谢您选用KDK产品。
安装,使用和维护KDK产品前,请仔细阅读本安装使用说明书。
安装前,请务必先阅读“安装注意事项”(第1415 页)。
不遵照此安装使用说明书进行操作有可能导致人员受伤或财产损失。
安装完成后,请向顾客说明如何使用和维护KDK产品,并将此安装使用说明书交给顾客保管。
请妥善保管好此安装使用说明书以备日后参考。
INSTALLATION AND
OPERATING INSTRUCTIONS
安装使用说明书
Air Curtain
风幕机
Contents
Safety instructions ..................... 2
Installation cautions .............. 23
Supplied accessories .................. 4
Parts name and dimensions ....... 4
Requirement of installation ........5
How to install ....................... 67
Multiple products operate
in group ..................................... 8
Wiring diagram .......................... 8
Operation methods ............... 89
Routine maintenance ........ 1011
Trouble shooting ..................... 12
Specifications ........................... 13
安全指引 ........................ 14
安装注意事项 ........... 1415
包装附件清单 .................. 16
部件名称及尺寸 ............... 16
安装要求 ........................ 17
安装方法 ................. 1819
多台组合运行
..................................... 20
电器原理图 ..................... 20
使用方法 ................. 2021
维护保养 ................. 2223
常见故障的识别与处理 ....... 24
规格 .............................. 25
目录
2509UA
3009UA
3509UA
4009UA
2512UA
3012UA
3512UA
4012UA
2515UA
3015UA
3515UA
4015UA
This indication meansMust be treated seriously that
this may result in death or serious injury.
This indication meansMust be treated seriously that
this may result in injury or physical damage.
The typese of details to be observed are classified and explained in the following
illustrated displays.(below are the series of illustrated displays)
This symbol indicates the
item“PROHIBITED”to do.
This symbol indicates the
“COMPULSORY “item that must
be followed without failure.
The following explanations must always be observed in order to prevent harm to
users or other people and prevent damage to property.
The following displays are classified and explained to what extent harm or damage
occurs when the display details are ignored and the unit in question is wrongly used.
Safety instructions Please observe strictly
Installation cautions
WARNING
WARNING
CAUTION
Wiring should be firmly connected
without any loose.
Please install an all-pole switch which
the contact separation is more than
3mmDouble pole switch
Otherwise, it may cause
a short circuit, thus
resulting a fire.
Do not operate the product other
than the rated voltage.
Otherwise, it may damage the
product or cause fire.
Do not reconstruct this product.
Otherwise, it may cause damage
to the product or injury.
Otherwise, it may cause a short
circuit, thus resulting a fire.
The product must be grounded.
Otherwise, it may cause electric
shock when there is any trouble
or electric leakage.
Installation should be done by
authorized person.The product should
be installed firmly.
Otherwise, the product may fall
down and it may cause injury.
If the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarlyqualified persons in order to avoid a hazard.
This product is not intended for use by persons (including children) with
reduced physical, sensory ormental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction
concerning use of the product by aperson responsible for their safety.
Children should be supervised to ensure that they do not play with the
product.
Make sure to disconnect the power supply before cleaning the product.
2
Installation cautions
Do not install the product as the
method which is not approved in the
installation and operating instructions.
Otherwise, the product any fall
down and it may cause injury.
It's prohibited to install the product in
locations such as machinery, chemical
plants or research facilities where it
will be exposed to noxious gases
containing acids, alkali, organic
solvents, paint fumes, etc., to gases
containing corrosive ingredients.
It could cause gas poisoning,
corrosion and degradation of
product that results in a fire.
The product must be installed tightly.
Components must be installed tightly.
Otherwise, it may injury person
caused by product's falling off.
It’s prohibited to install in the following locations.
Indoor Outdoor
Do not install the product
where there is steam.
Location with combustible
gas or emission of exhaust
gas.
Do not install the product
out of the window and
wall.
Otherwise, it may cause
a short circuit, thus
resulting in a fire.
Otherwise, it may cause
a short circuit, thus
resulting in a fire.
Otherwise, the product
may get wet in the rain and
cause short circuit.
WARNING
The product must be mounted on a
building which is strong enough.To
ensure it can bear over 5 times of
product weight.The building must be
reinforced if its strength can not be
ensure.
Otherwise, the product
may fall down and it
may cause injury.
The special-purpose or dedicated
parts, such as mounting fixtures,
must be used if such parts are
provided.
Otherwise, the product may fall
down and it may cause injury.
Please wear the gloves when installing
the product.
Otherwise, it may
cause damage.
Product must be installed by 2
persons.
Otherwise, the product may fall
down and it may cause injury.
CAUTION
3
Supplied accessories
The following attachments are enclosed in the packing box of product.Be sure to check
if they are complete after unpacking, and if anything is missed, contact our After-Sales
Service Center or the dealer.
Parts name and dimensions
Front view
Back view
8 holes
(8mm wooden screws are used)
6 holes
(M8 bolts are used)
Power supply cord
Right view
Please refer to the table above to recycle the materials as much as possible
when discarding this product.
No. Part name
Resin ABS
Classification
Front panel
Air outlet
Mounting plate Steel SGCC
Back panel Steel SGCC
Assembly partMotor
Motor support
Cross-flow impeller
Push–button switch
Steel plate +ResinAS
+Glass fiber
Resin ABS
Guide plate
No. Part name Classification
Steel SGCC
Assembly part
Resin ABS
Notice
A
900
1200
1500
B
50
200
350
Model No.
2509UA, 3009UA, 3509UA, 4009UA
2515UA, 3015UA, 3515UA, 4015UA
2512UA, 3012UA, 3512UA, 4012UA
A212
231.5
250 250 250
B 400 400 B
62120
22
170
Direction
of
Air outlet
Washer 6
Installation and
operating
instructions
Spring
washer 6
6
Bolt
M8×60L
Nut
M8
No.
Drawing Name
Quantity No.
Drawing Name
Quantity
6
1
Service
parts list
1
4
Requirement of installation
Please observe the following requirement.Otherwise, it may cause the product
aging and breakdown.
The applicable ambient temperature
of this product is in the range of
-1040 .
Locations where freezing could happen.
It’s prohibited to install in the uneven
surface.(Flatness shall be 3mm below.)
Otherwise, it may damage the
product or cause fire.
40℃ Distortion results in reducing the
separation performance.
Do not install the product where it is
exposed to oil fumes.
Do not install the product in the place
with many dust.
Impeller deformation may be caused
by sand and dust piling up, which may
affect the performance.
The lowest surface of this product
should be installed above 2.3m from
the floor after installation.
The distance between product and
ceiling must be 50mm above.
The ceiling is excessively close
to air inlet that may reduce the
separation performance.
Please install the product horizontally,
don’t vertically install the product.
It could affect the performance
of bearing.
Ensure the space among products is
2040mm when multiple products
operate in row.
Please block the clearance between
wall and product.
Prevent product
from sucking in
outdoor air from
clearances.
50mm above
2040mm
2.3m above
Easy for installation.
Avoiding any accident.
5
How to install
1.Fix the mounting plate
Mounting on concrete wall.
1.Remove mounting plate from product.
Taking the mounting plate by removing
the 3 screws.
2.Firmly fix the bolts in the proper position.
·Determine the position on the wall and drill into the wall.
·Fit the bolts into the holes.
·Fill the holes with concrete.
·Install the mounting plate and check
if it’s secured when the concrete solidifies.
3.Fix the mounting plate with washers,
spring washers and nuts.
Please use the mounting plate provided
with product to avoid the dropping
caused by insufficient strength.
CAUTION
Pre-hang up the product into the bottom holes of mounting plate.
2.Preparation before wiring
Other installation methods
Mounting on steel
hanger
M8 bolt
15mm
below
Mounting on wooden
frame
Wooden
screw
(Φ8×60L
Mounting inside the ceiling
1.The inside space of ceiling should exceeding
the dimensions as indicated above to ensure
the space of air inlet, please select the larger
model if space of air inlet can't be reserved.
2.Don’t place the substances near the air inlet
or outlet grilleinclude the grille .
It could affect the performance.
1.It’s prohibited to install the product on
hollow wall, otherwise it may produce noises.
2.Conduct the necessary reinforcement,
depending on the particular condition to
avoid noise resonance and vibration.
Partition plate
(not supply)
is installed
at four sides.
350mm above
Ceiling
100mm above
Screw
Mounting
Plate
Concrete
Bolt
M8×60L
About70mm
Ddiameter40-50mm
Washer
Nut
Spring
washer
Mounting
plate
Wall
Bottom holes
150mm
above
Carry out this step if the distance between top
face of product and ceiling is less than 150mm.
Notice
Distance of bolt head away from wall
should be 1315mm.
13-15mm
Notice
6
How to install
Wiring is required to follow the local wiring regulations.
Otherwise, it may cause fire.
Please select 60227 IEC 53 ordinary polyvinyl chloride sheathed cord.
Nominal cross-sectional area of conductors is 3×1.0mm2.
Otherwise, it may cause fire.
The product is not provided with Double pole switch and leakage protection
switch. Please purchase them in market.
It is required to use terminal not supply that complies IEC 60998 and
wiring boxnot supply that complies local regulation.
Wiring should be firmly connected without any loose.
3.Wiring
Connect the power cordincluded earth of product to lead wire in accordance with the wiring
diagram.
Make sure all connections are fastened firmly after finishing wiring.
Power cord
of the product
Lead wire
from source
Air curtain
Power cord
of the product
Green/Yellow
Earth
Earth wire
Power
supply cord Terminal block
not supply
Live
L
Neutral
N
Brown
L
Blue
N
WARNING
Back panel
Mounting plate
Groove
1.Remove the product from the bottom holes.
2.Fixing the product.
Align the groove of back panel with both sides of
mounting plate. Fit the hooks into the top holes of
mounting plate.
3.Fasten the screws. (3 places)
4.Installation of product
Wiring box
not supply
Notice
The torque is suggested to be 1.2N·m.
Bottom holes
Top holes
7
Multiple products operate in group
Wiring diagram
Power supply cord
Please purchase necessary parts
following with local electrical
requirements.Except the power
supply cord.
Please select the switch of whose
capacity has 1.21.5 times total
current, when multiple products
operate.
Earth leakage breaker protector
should be equipped, otherwise it
may cause an electrical shock.
The number of interlocking
operation is not more than 6.
Red
Black
White
(
H
)
Yellow
(
L
)
Yellow
White
Black
Capacitor
Motor
Switch
Power
TERMINAL
Source
Orange
Blue
Double Pole Switch
Customer Provide
(Contact Point Separate Distance Over 3mm)
Green/Yellow
N
L
N
L
Brown
WARNING
Operation of Control panel
Start to operate
1
Press “HI”or“LO” button to start the product as
shown in left figure.
OFF
OFF LO HI
Representative model
Operation methods
2Select the mode of operation
Press “HI” button if high air velocity is required.
Press “LO” button if quiet and low velocity
is required.
LO HIOFF
LO HIOFF
LOW HIGH
8
Operation methods
3Stop operating
The product is in stand-by mode after pressing the “OFF”, it’s still connected to
the power
Press “OFF” button to stop the product.
LO HIOFF
1
2
3
Guide vane in air outlet can be adjusted according to service environment to reach the
ideal separation performance.
Light wind
in outdoor
Strong wind
in outdoor
Hot indoor
Air outlet
Guide vane
Cold outdoor
While strong wind in outdoor
While light wind in outdoor
Heating
4
Air outlet Guide vane
Cooling
Air outlet Guide vane
1.Room has opening
(window, grille, etc.)
2.Room is air tight
(no opening)
Air outlet Guide vane
Cold
indoor
Hot
outdoor
Cold
indoor
Hot
outdoor
Air outlet Guide vane
Notice
9
Routine maintenance
Make sure to disconnect power
supply before cleaning product.
Otherwise, the
product might
operate with the possibility of
electric shock or injury.
If you will not use this product any
more, remove the product.
Otherwise, the product may fall
down and it may cause injury.
Please contact entrusted distributor
where you purchased or qualified
persons to service the product.
Otherwise, it may damage the
product or cause fire.
Once flammable gas leaks, do not
start any function of this product.
Don’t turn on or off the power with
wet hands.
It may cause a electrical shock.
It’s prohibited to place the burning
appliances in a position where product
directly blows.
It may result in carbon
monoxide poisoning
caused by incomplete
combustion.
Do not let water flow into the motor.
It’s prohibited to insert fingers or
sticks into the product, air inlet or
outlet.
Impeller at high speed
rotation may cause injuries.
Otherwise, it may damage the
product or cause fire.
WARNING
Please wear the gloves when cleaning
the product.
Otherwise, it may cause damage.
Do not directly spray this product with
water and other liquids.
Otherwise, it may cause short
circuit or electric shock.
It’s forbidden to hang anything on
the product.
Product may drop due to
the increased weight.
CAUTION
Otherwise, it may generate
sparkle and this leads to explosion.
2 persons are required to conduct
the maintenance.
Otherwise, the product may
fall down and it may cause
injury.
Immediately stop to wait for repair if
abnormities happen (noise, vibration,
smell ).
It may cause the unexpeted
accidents.
10
Routine maintenance
Eyes should not be faced to the
air outlet (specially when the product
stars up).
Please don’t place the substances
near to the air outlet or inlet grille.
It may result in personal
injuries due to blowing out
or sucking in.
The strong air from air curtain may
cause the sand and dust.
Otherwise, dropping caused by
corrosion of product, which
may result in personal injuries.
Never use petrol, benzene thinner or
any other such chemicals for cleaning
the product.
Disassembly of part
This part can be easily taken out by
removal of 7 screws as indicated in
the right figure.
It may result in personal
injuries.
Make sure to disconnect power supply
before cleaning product.
Metallic brush
Thinner
Gasoline
Volatile oil
CAUTION
Notice
The blowing substance
could damage your eyes.
11
Trouble shooting
Condition 1st Possible reason 2nd Possible reason 3rd Possible reason
Can't operate. Check the voltage. Wiring is not correct.
With large noise
or significant
vibration.
Installed not properly.
P6P7
Poor separation
performance.
Not suitable model. Guide vane is not in
proper position.
P9
Product is installed
vertically.
Can’t operate. Wiring is not fixed. Double pole switch
became off.
Poor separation
performance.
Air inlet grille is
blocked.
With large noise
or significant
vibration.
Dust piles up in
impeller.
Any other substances
fell into the product.
Motor runs abnormally.
Primary Period During operation
P7
Check according to the following table and take measures.If the product
still does not work normally, disconnect the power and contact After-Sale
Service Center or the dealer.
12
Specifications
1.The parameters as shown in above table are measured at ambient temperature of 20.
2.The noise value is measured 1.5m away from the product at angle of 45° below the air outlet.
3.Because the above-mentioned velocity is measured in test laboratory where it’s empty,
without air flow and obstacle, after actual installation the velocity may vary depends on
different service environment.
4.Outlet velocity is the maximum value.
Voltage: 1 phase 220V Frequency: 50Hz
Voltage: 1 phase 240V Frequency: 50Hz
Notice
Power
Consumption
W
Outlet
Velocity
m/s
Current
A
Air Volume
m³/h
Noise
dB(A) Length
mm
Installation
height
m
Model
2509UA
2512UA
2515UA
3009UA
3012UA
3015UA
3509UA
3512UA
3515UA
4009UA
4012UA
4015UA
High Low High Low High Low High Low High Low
Weight
kg
Insulation
Class
8.5 7.5 63 55 0.29 0.28 95041.5 B 900840 12 2.544
8.5 7.5 77 75 0.35 0.34 125041 B 12001150 14 2.543
8.5 7.5 93 73 0.42 0.34 140042 B 15001150 17.5 2.545
10.5 8.5 76 70 0.35 0.32 110045 B 900920 12 3.048.5
9.5 894 85 0.43 0.4 140044.5 B 12001270 14.5 3.048.5
10.5 9.5 131 110 0.59 0.5 200048 B 15001800 18 3.051.5
11 995 85 0.41 0.39 115049 B 9001000 12 3.551
10.5 8.5 114 100 0.49 0.46 155046 B 12001300 14.5 3.549
11 9146 110 0.67 0.52 180049 B 15001500 18 3.552
12 10 110 94 0.5 0.43 134051 B 9001190 12.5 4.054.5
12 10 126 105 0.59 0.49 170048.5 B 12001530 15.5 4.052.5
13 10 177 147 0.81 0.68 245052 F 15002080 18 4.056
Power
Consumption
W
Outlet
Velocity
m/s
Current
A
Air Volume
m³/h
Noise
dB(A) Length
mm
Installation
height
m
Model
2509UA
2512UA
2515UA
3009UA
3012UA
3015UA
3509UA
3512UA
3515UA
4009UA
4012UA
4015UA
High Low High Low High Low High Low High Low
Weight
kg
Insulation
Class
9871 65 0.31 0.29 100043.5 B 900900 12 2.546
9889 86 0.37 0.36 135044 B 12001250 14 2.546
98106 84 0.44 0.35 150045 B 15001250 17.5 2.548
10.5 986 80 0.37 0.35 115047.5 B 900960 12 3.050.5
10 8.5 107 95 0.46 0.43 150047 B 12001320 14.5 3.050.5
11 10 145 115 0.6 0.5 210050.5 B 15001850 18 3.053.5
11.5 9.5 99 96 0.42 0.4 120051 B 9001050 12 3.554
11 9122 112 0.51 0.47 165048 B 12001400 14.5 3.551
11.5 9.5 161 125 0.68 0.54 180051 B 15001600 18 3.554
12.5 10.5 122 100 0.51 0.43 136053.5 B 9001200 12.5 4.056.5
12.5 10.5 139 110 0.6 0.49 180051 B 12001580 15.5 4.054.5
13.5 10.5 190 160 0.86 0.68 250054.5 F 15002050 18 4.058
13
本标志所表示内容为“不遵守的话可能造成人员死亡或重伤”。
本标志所表示内容为“不遵守的话可能造成人身轻伤或其他财产损害”。
■务必遵守的内容分类,用标志区分说明如下:
此标志表示为禁止事项。此标志表示为强制事项。
为了避免给您及其他人造成伤害,这里我们列出了以下安全注意事项,请务必遵守,各种标志的
含义请参见以下内容。
■无视或错误理解这些标志,会产生下列两种情况。
请务必遵守
安装注意事项
警告
警告
注意
■电源线连接处必须牢固,不能有松动。
■安装时,须在供电线路中安装其触电开距
不少于3mm的全极断开装置(双极开关)。
否则可能会导致短路,导致火灾。
■禁止使用额定电压以外的电源。
否则可能会导致损坏本产品,导致
火灾。 ■禁止对本产品进行改造。
否则可能会导致产品损坏或受伤。
否则可能会导致短路,导致火灾。
■必须接地。
当出现故障或漏电时,可能会触电。
■必须由专业人员进行安装,必须牢固地安装
产品。
否则产品可能会掉落,导致受伤。
■ 如果电源线损坏,为了避免危险,必须由制造商、其维修部或类似部门的专业人员
更换。
■ 本产品不适合有残疾、智障或精神障碍的人士,或缺乏经验常识者(包括儿童)维
护使用,除非在监护人的看护或指导下使用。
■ 在维护保养期间,儿童应该有人进行看护,以防将产品当做玩具。
■ 维护保养产品前,请务必断开电源。
安全指引
14
安装注意事项
■禁止使用本安装使用说明书指定以外的方
法进行安装。
否则产品可能会掉落,导致受伤。
■请勿将产品安装在机械厂、化学工厂及研究
设施等产生酸、碱、有机溶剂、涂料等有害
气体和含有腐蚀性成分气体的地方。
易引发气体中毒、产品内部腐蚀、
劣化,而引起火灾。
■产品安装必须牢固。
部品安装必须牢固。
否则产品可能会掉落,导致受伤。
■禁止安装在以下场所。
室内 室外
请勿安装在有蒸汽的场所。 禁止安装在有可燃性气体、
排放废气的地方。
禁止将产品安装于窗户外或墙
壁外。
否则可能会导致短路,导致火灾。 否则产品可能会淋雨,导致短
路。
■安装产品的建筑结构必须牢固,确保有能
承载大于产品重量5倍的强度。如不能确保
安装强度,请务必采取加固措施。
否则产品可能会掉落,
导致受伤。
■有安装五金件等专用零部件时,应使用
专用零部件。
否则产品可能会掉落,导致受伤。
■安装时请带上手套。
否则可能会导致受伤。
■产品必须由2位安装人员进行安装。
否则产品可能会掉落,导致受伤。
否则可能会导致短路,
导致火灾。
警告
注意
15
包装附件清单
随产品包装箱有以下附件,开箱后请清点是否齐全,若不齐全,请与KDK客户咨询服务中心
或经销商联系。
部件名称及尺寸
■前视图
■后视图
8个安装螺钉孔(使用Φ8mm木螺钉)
6个安装孔(使用M8固定螺栓)电源线
■右视图
A212
231.5
250 250 250
B 400 400 B
62120
22
170
当丢弃该产品时,请参照上边的表格尽可能回收材料。
序号 零部件名称
树脂 ABS
材质
前面板
出风口
安装板 钢板 SGCC
后面板 钢板 SGCC
组合件电动机
电动机支架
贯流风轮
琴键开关
钢板+树脂AS+玻纤
树脂 ABS
导流板
序号 零部件名称 材质
钢板 SGCC
组合件
树脂 ABS
提示事项
A
900
1200
1500
B
50
200
350
型号
2509UA, 3009UA, 3509UA, 4009UA
2515UA, 3015UA, 3515UA, 4015UA
2512UA, 3012UA, 3512UA, 4012UA
垫圈 6
安装使用
说明书
弹簧垫圈 6
6
固定螺栓
M8×60L
螺母
M8
序号
图样 名称
数量 序号
图样 名称
数量
6
1
售后服务
部品清单
1
16
安装要求
■请遵守以下安装要求事项,否则有可能会导致产品老化或发生故障。
本产品适用环境温度-1040 ℃。
请勿安装在产品可能冻结的地方。
请勿安装在凹凸不平的平面上。
(平面度应控制在3mm以下)
否则可能会导致损坏本产品,导致火灾。
40℃ 否则产品可能会变形,导致产品的隔断效
果降低。
请勿安装在油烟过多的场所。
请勿安装在灰尘较多的场所。
灰尘堆积在贯流风轮上,导致贯流风轮变
形,影响产品性能。
■安装完成后产品最低面至地面的距离必须
大于2.3m
■产品和天花板之间的距离请保持50mm以上。
天花板与进风格栅过近,会导致
产品的遮断效果降低。
■产品请水平安装。不可纵向安装。
会影响轴承性能。
■多台并排使用时,产品与产品之间最好能保
2040mm的距离。
■请封堵墙壁与产品之间的缝隙。
防止产品进风格栅
吸入从缝隙进入的
室外空气。
50mm 以上
2040mm
2.3m 以上
易于安装。
防止意外。
17
安装方法
1.固定安装板
■安装于混凝土墙壁上。
1.取下安装板。
将背面下方的固定螺钉(3处)取下,
即可顺利取下安装板。
2.牢固地将固定螺栓固定在正确位置。
·在墙壁表面决定固定螺栓正确位置后,向墙壁进行钻孔。
·向墙壁的孔上嵌入固定螺栓。
·墙壁内用混凝土灌注。
·当混凝土凝固后,装上安装板,并检查是否牢固。
3.固定安装板。
使用垫圈、弹簧垫圈、螺母固定安装板。
固定
螺钉
安装板
混凝土
固定
螺栓
M8×60L
大约70mm
直径:40-50mm
■其他安装方法
安装在钢铁骨架上
M8
固定螺栓
15mm
以下
安装在木材骨架上
8×60L
安装在天花板里侧
1.天花板里侧的空间要大于上图尺寸,以确保吸风
的空间。无法确保上记吸风空间时,请选用高一
档型号。
2.不要在出风口和进风格栅附近放置物体。
(包括:格栅)可能影响产品性能。
1.严禁安装在空心墙体。有可能产生噪音。
2.根据情况请进行加固措施。避免出现共鸣、共振。
分隔板(另购)
设在四侧。
350mm以上
天花板
100mm以上
■要使用随机配备的安装板。
避免由于强度不足引起的产品掉落。
注意 垫圈
螺母
弹簧垫圈
安装板
墙壁
将后面板上的挂钩嵌入安装板的底部安装孔上。
底部安装孔
150mm 以上
2.引线连接前准备当产品顶部与天花板之间无法确保150mm时,实施此步骤。
提示事项
固定螺栓要露出墙壁表面 1315mm 13-15mm
提示事项
木螺钉
(Φ
18
安装方法
■器具应按照国家布线规则进行安装。
否则可能会导致火灾。
■电源线请选用60227 IEC 53型绞合软线,导线的截面积为3×1.0mm2
■本产品没有附带电源双极级开关和漏电保护开关,需用户另购。
否则可能会导致火灾。
■要求使用符合IEC 60998的接线端子座(另购),符合当地标准的接线盒(另购)。
■电源线连接处必须牢固,不能有松动。
3.引线连接
■根据接线示意图,将产品电源线(包括地线)连接到供电电源线上。
■接线完成后,必须检查所有连接是否牢固。
产品电源线
风幕机
产品电源线
绿/黄
(地线)
地线
供电电源线
供电电源线
接线端子座
(另购)
火线
L
零线
N
L
N
警告
接线盒
(另购)
4.产品的安装
1.从安装板的底部安装孔上取出产品。
2.产品固定。
后面板下部的凹槽与安装板两端对齐。
将后面板上的挂钩嵌入安装板顶部安装孔上。
3.将本体下方的螺丝钉锁紧。(3处)
后面板
安装板
凹槽
提示事项
建议扭力为:1.2N m
底部安装孔
顶部安装孔
19
(
)
(
)
电容器
电机
开关
电源
端子
双极开关
(另购)
(触点分离距离在3mm以上)
绿/黄
N
L
N
L
供电电源线
●除产品电源线以外的其他配线及电器部件请按当
地电器要求购买!
■多台连动时,请选用容量在多台产品合计
电流1.21.5倍的接线开关。
■要安装漏电保护开关,否则可能导致触
电。
■并联使用的产品数量应少于6台。
警告
操作面板的使用
开始运行
选择运行模式
按左记 “HI”或“LO” 任意键启动风幕机。
想要高风速运行时,请按下“HI”按键。
想要低风速安静的运行时,请按下“LO”按键。
关 弱
※代表型号
多台组合运行
电器原理图
1OFF LO HI
使用方法
2LO HIOFF
LO HIOFF
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26

KDK 3512UA 取扱説明書

タイプ
取扱説明書

他の言語で