TP-LINK TL-FC1420 インストールガイド

タイプ
インストールガイド

このマニュアルも適しています

14-Slot Rackmount Chassis
Installation Guide
Package Contents: Chassis, AC Power Cord, Fourteen Retainer-plates, Installation Guide
Installation
Step 1: Install the Media Converters in the Chassis
Note:
It is recommended to use TP-Link media converters. Other vendors’ products may
be incompatible.
To ask questions, find answers, and communicate with TP-Link users or
engineers, please visit https://community.tp-link.com to join TP-Link
Community.
© 2022 TP-Link 7106509905 REV3.2.2
The pictures are for demonstration purposes only. The actual product may dier in appearance from the depicted.
For technical support and other information, please visit
https://www.tp-link.com/support, or simply scan the QR code.
1. Tweak out the two screws on the media converter. Then install the
retainer-plate (provided with the chassis) to the media converter using
the screws removed from the media converter.
2. Remove the front metal plate of the slot on the chassis, then carefully
slide the media converter into the slot and lock it tightly with the
locking knob.
Step 2: (Optional) Install the Redundant Power Supply Module
Step 3: Mount the Chassis on the Rack
Step 4: Power On
Note:
1. The chassis supports EIA standard-sized, 19-inch racks.
2. For security reasons, it is recommended to install the chassis as shown below.
1. Electrically connect the Grounding Terminal on the rear panel of the
chassis to ground via the ground cable.
2. Connect the chassis to the AC outlet using the provided power cord.
Fasten the chassis to the rack with screws through the holes of the
brackets on each side.
Remove the protective cover on the power supply module slot of the chassis.
Then gently push in the module and plug it solidly into the connector.
Grounding Terminal
Chassis
Panel Layout
Input: 100–240 V ~ 50/60 Hz 1.8 A (Max)
Output: 12 V, 6.25 A (Max)
Ripple & Noise: < 180 mV (0˚C to 50˚C);
< 250 mV (-10˚C to 0˚C)
AC Power Supply
Power, FANLED
Dimensions
(W×D×H)
Operation Temperature TL-MC1400: 0˚C to 40˚C (32˚F to 104˚F)
TL-FC1420: 0˚C to 50˚C (32˚F to 122˚F)
Storage Temperature -40˚C to 70˚C (-40˚F to 158˚F)
Storage Humidity 5% to 90% RH non-condensing
482 × 309 × 86 mm
Operation Humidity 10% to 90% RH non-condensing
Specifications Environmental and Physical Specifications
Specications
Power LED
AC Power Plug
Grounding Terminal FAN
Optional Power Supply Position
LED Explanation
On: Power on
O:
Power o
Power
On: The fans are working properly.
O:
The fans are working abnormally.
FAN
Note:
· An optional AC or DC power supply is available for installation in the optional power supply position.
· The power source should comply with Electrical Energy Source Class 1 (ES1) of IEC 62368-1.
YesHot-swappable
YesOverload Protection
FAN LED
DC Power Output per Slot TL-MC1400: 9 V/0.6 A
TL-FC1420: 5 V/0.6 A
Safety Information
Keep the device away from water, re, humidity or hot environments.
Do not attempt to disassemble, repair, or modify the device. If you need service, please contact us.
Avoid using this product during an electrical storm. There may be a remote risk of electric shock from
lightning.
The label is placed on the bottom surface of the product.
Place the device with its bottom surface downward.
The socket-outlet shall be installed near the equipment and shall be easily accessible.
Plug the product into the wall outlets with earthing connection through the power supply cord or plug.
EU Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other
relevant provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC, 2011/65/EU and (EU)2015/863.
The original EU declaration of conformity may be found at https://www.tp-link.com/en/ce.
Please read and follow the above safety information when operating the device. We cannot guarantee
that no accidents or damage will occur due to improper use of the device. Please use this product
with care and operate at your own risk.
In Denmark: Apparatets stikprop skal tilsluttes en stikkontakt med jord som giver forbindelse til
stikproppens jord.
In Finland: Laite on liitettävä suojakoskettimilla varustettuun pistorasiaan
In Norway: Apparatet må tilkoples jordet stikkontakt
In Sweden: Apparaten skall anslutas till jordat uttag
CAN ICES-3 (A)/NMB-3(A)
Industry Canada Statement
この装置は、クラスA情報技術装置です。この装置を家庭環境で使用すると電波妨害を引き起こすことがありま
す。この場合には使用者が適切な対策を講ずるよう要求されることがあります。 VCCI-A
FCC compliance information statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference
that may cause undesired operation.
Any changes or modications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
Product Name: 14-Slot Rackmount Chassis
Model Number: TL-MC1400/TL-FC1420
Responsible party:
TP-Link USA Corporation, d/b/a TP-Link North America, Inc.
Address: 145 South State College Blvd. Suite 400, Brea, CA 92821
Website: https://www.tp-link.com/us/
Tel: +1 626 333 0234
Fax: +1 909 527 6803
We, TP-Link USA Corporation, has determined that the equipment shown as above has been shown to comply with
the applicable technical standards, FCC part 15. There is no unauthorized change is made in the equipment and
the equipment is properly maintained and operated.
Issue Date: 2020/07/24
This is a class A product. In a domestic environment, this product may cause radio interference, in which case the
user may be required to take adequate measures.
CE Mark Warning
Caution
Shock hazard
Disconnect all power sources
BSMI Notice
安全諮詢及注意事項
請使用原裝電源供應器或只能按照本產品注明的電源類型使用本產品。
清潔本產品之前請先拔掉電源線。請勿使用液體、噴霧清潔劑或濕布進行清潔。
注意防潮請勿將水或其他液體潑灑到本產品上。
插槽與開口供通風使用以確保本產品的操作可靠並防止過熱請勿堵塞或覆蓋開口。
請勿將本產品置放於靠近熱源的地方。除非有正常的通風否則不可放在密閉位置中。
請不要私自拆開機殼或自行維修如產品有故障請與原廠或代理商聯繫。
此為甲類資訊技術設備于居住環境中使用時可能會造成射頻擾動在此種情況下使用者會被要求採取某些適
當的對策。
限用物質含有情況標示聲明書
產品元件名稱
PCB
外殼
產品元件名稱
PCB
外殼
限用物質及其化學符號
備考: "○"系指該項限用物質之百分比含量未超出百分比含量基準值。
Pb
Cd
Hg
六價鉻
Cr+6
多溴聯苯
PBB
溴二苯醚
PBDE
Explanation of the symbols on the product label
RECYCLING
This product bears the selective sorting symbol for Waste electrical and electronic equipment
(WEEE). This means that this product must be handled pursuant to European directive 2012/19/EU
in order to be recycled or dismantled to minimize its impact on the environment.
User has the choice to give his product to a competent recycling organization or to the retailer
when he buys a new electrical or electronic equipment.
Indoor use only
DC voltage
Polarity of output terminals
AC voltage
Polarity of the power supply module
Caution, risk of electric shock
Disconnection, all power plugs
  • Page 1 1
  • Page 2 2
  • Page 3 3

TP-LINK TL-FC1420 インストールガイド

タイプ
インストールガイド
このマニュアルも適しています

他の言語で