Hitachi RA-13JF2 Operation and Installation Manual

カテゴリー
スプリットシステムエアコン
タイプ
Operation and Installation Manual
RA-13JF2_EN 29/09/2006, 09:19 am1
– 2 –
PRECAUTIONS DURING INSTALLATION
SAFETY PRECAUTION
Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
Pay special attention to signs of Warning” and Caution”. The “Warning” section contains matters which,
if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result
in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
” sign in attached figure indicates prohibition.
Please keep this manual after reading.
WARNING
Please ask your sales agent or qualified technician for the installation of your unit. Water
leakage, short circuit or fire may occur if you install the unit yourself.
Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor or the earth line
of telephone. Improper installation of earth line may cause electric shock.
A circuit breaker should be installed depending on the mounting site of the unit. Without
a circuit breaker, the danger of electric shock exists.
Do not install near location where there is flammable gas. The unit may catch fire if
flammable gas leaks around it.
Please ensure smooth flow of water when installing the drain hose. (For drain model)
CAUTION
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
WARNING
Should abnormal situation arises (like burning smell), please stop operating the unit and turn off the
circuit breaker. Contact your agent. Fault, short circuit or fire may occur if you continue to operate
the unit under abnormal situation.
Please contact your agent for maintenance. Improper self maintenance may cause electric shock
and fire.
Please contact your agent if you need to remove and reinstall the unit.
Electric shock or fire may occur if you remove and reinstall the unit yourself improperly.
PRECAUTIONS DURING OPERATION
Avoid an extended period of direct air flow for your health.
Do not put objects like thin rods into the panel of blower and suction side because the high-speed fan inside may cause
danger.
Do not use any conductor as fuse wire, this could cause fatal accident.
During thunder storm, disconnect and turn off the circuit breaker.
The product shall be operated under the manufacturer specification and not for any other intended use.
Do not attempt to operate the unit with wet hands, this could cause fatal accident.
When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen insufficiency.
Do not direct the cool air coming out from the air-conditioner panel to face household heating apparatus as this may affect
the working of apparatus such as the electric kettle, oven etc.
Please ensure that unit mounting frame is always stable, firm and without defect. If not, the unit may collapse and
cause danger.
Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit.
Do not place plants directly under the air flow as it is bad for the plants.
Please switch off the unit and turn off the circuit breaker during cleaning, the high-speed fan inside the unit may cause
danger.
Turn off the circuit breaker if the unit is not be operated for a long period.
Do not climb on the unit or put objects on it.
Do not put water container (like vase) on the unit to avoid water dripping into the unit. Dripping water will damage
the insulator inside the unit and causes short circuit.
When operating the unit with the door and windows opened, and with the air deflector facing down for a long period of time, water
will condensed on the air deflector and drips down occasionally. This will wet your furniture. Therefore, do not operate under such
condition for a long time.
If the amount of heat in the room is above the cooling capability of the unit (for example: more people entering the room, using heating
equipments and etc.), the preset room temperature cannot be achieved.
W
A
R
N
I
N
G
RA-13JF2_EN 29/09/2006, 09:19 am2
– 3 –
PARTS IDENTIFICATION AND OPERATIONS
1 Cabinet
2 Suction Grille
3 Horizontal Deflectors
4 Vertical Deflector
5 Air Exhaust Lever
6 Front Cover
7 Switch Panel Cover
CONTROL PANEL
1 Auto Swing Switch
2 Operation Mode Selector Dial
3 Thermostat Dial
OPERATION MODE SELECTOR DIAL
OFF Stop the fan and cooling operation.
QUIET FAN The air conditioner will perform fan operation only at low speed.
HI FAN The air conditioner will perform fan operation only at high speed.
QUIET COOL Cooling operation with low fan speed. This is recommended for sleeping comfort.
HI COOL Cooling operation with high fan speed for maximum cooling power.
1
2
3
4
5
7
AUTO SWING
WAIT 3 MINUTES
BEFORE
RESTARTING
CAUTION
QUIET FAN
ON
OFF
HI FAN
TEST
COOLER
HI COOL
OFF
QUIET COOL
TEMPERATUREMAIN SWITCH
1
2
3
4
5
9
8
7
6
10
123
AUTO SWING
When the AUTO SWING switch is turned to “ON” position, the vertical deflectors automatically
oscillate right and left sweeping the cold air alternately to obtain comfortable cooling.
The vertical deflectors may be stopped at any position when the AUTO SWING switch is
turned “OFF”.
The starting operation will occur an abnormal sound (turbo sound) which doesn’t affect the
operation.
6
Model Width Height Depth
RA-13JF2 22
1
/
16
", 560mm 14
3
/
4
", 375mm 28
1
/
8
", 714mm
RA-13JF2_EN 29/09/2006, 09:19 am3
– 4 –
Setting the desired room temperature. Turn the dial further clockwise for cooler indoor temperature.
The compressor operates continuously by setting the temperature dial to “TEST”.
This setting is used for technician. If the unit is operated at this position, the heat
exchanger may freeze and causing water leakage or other malfunction. Do not
set to “TEST” for normal usage.
When the compressor stops by turning the temperature dial counterclockwise in
cooling operation, wait 3 minutes before turning it clockwise to restart it.
CAUTIONS
AIR DEFLECTORS
VERTICAL DEFLECTORS
Vertical deflectors at both sides of outlets can
be set to either auto-swing or static position to
direct discharge air rightward, leftward or forward
direction.
HORIZONTAL DEFLECTORS
Horizontal deflectors at both sides of the outlets
can be set to direct discharge air upward,
downward or forward direction.
Vertical
Deflector
Vertical
Deflector
Horizontal
Deflectors
Horizontal
Deflectors
CAUTION
To avoid dew forming on the deflectors which eventually may drip to the floor, please do not adjust
horizontal deflectors extremely downward position or vertical deflectors extremely leftward or rightward
position during cool operation for a long time.
Also, do not adjust the vertical deflectors position by hand or any other object.
Set the air exhaust lever to the down (OPEN)
position for air ventilation in the room. The air
exhaust lever should normally be kept in up
(CLOSE) position during cooling operation and in
the case of typhoon.
Air Exhaust Lever
AIR EXHAUST LEVER
THERMOSTAT DIAL
RA-13JF2_EN 29/09/2006, 09:19 am4
– 5 –
AIR CLEANING FILTER
ALWAYS STOP THE OPERATION BEFORE INSTALLING THE AIR CLEANING FILTER.
AIR CLEANING FILTER IS WASHABLE AND REUSABLE UP TO 20 TIMES BY USING VACUUM
CLEANER OR RINSE WITH RUNNING TAP WATER.
AIR CLEANING FILTER SHOULD BE CLEANED EVERY MONTH OR SOONER IF NOTICEABLE
LOADING OCCURS. WHEN USE OVERTIME, IT MAY LOSE ITS DEODORIZING FUNCTION.
FOR MAXIMUM PERFORMANCE, IT IS RECOMMENDED TO REPLACE IT EVERY 3-6 MONTHS
DEPENDING ON APPLICATION REQUIREMENT.
TYPE NUMBER FOR THIS AIR CLEANING FILTER AS TABLE BELOW:-
PLEASE USE THIS NUMBER FOR ORDERING WHEN YOU WANT TO RENEW IT.
Air Cleaning
Filter
Hook
1. Open the suction grille
2. Remove the normal
filter
3. Install the air cleaning filter
in the frame
4. Install back the normal filter
and close the suction grille
TEMPERATURE AND HUMIDITY
Avoid to use the room air conditioner for cooling operation when the outside temperature is below
21°C (70°F). Recommended operation humidity should be below 80%. Continuous long operation at
over 80% humidity (indoor) will cause some dews form on the outlet grille of the unit.
NOISE
In a quiet environment or stopping and starting operation, phenomena like flowing noise of refrigerant
in the refrigerating cycle and rubbing noise from the fan casing may occasionally occur, but this is
normal for the operation.
Water will condense on the evaporator coil and collected in the bottom tray, it is picked up by the
condenser fan and blown onto the condenser coil, this creates a “splashing” noise which is normal.
ODOR
The odor will possibly be emitted from the room air conditioner especially at the starting of operation
and in a high humidity condition. This is not abnormal phenomena because of the various kind of
odors emitted by smoke, food stuffs, cosmetics and others which may stick to the room air conditioner.
So, please clean the air filter and evaporator at the beginning of long no operation period to reduce
the odor.
NOTES ON OPERATION
TYPE NO.
MODEL
RA-13JF2
SPX-CFH8W
RA-13JF2_EN 29/09/2006, 09:19 am5
– 6 –
Ventilation
THE IDEAL WAYS OF OPERATION
Suitable Room Temperature
Warning
Freezing temperature
is bad for health and a
waste of electric
power.
Install Curtain or Blinds
It is possible to
reduce heat
entering the room
through windows.
Please Adjust Suitable Temperature
For Baby And Children
Do Not Forget To Clean The Air Filter
Dusty air filter will reduce the air
volume and the cooling efficiency. To
prevent from
wasting electric
energy, please
clean the filter
every 2 weeks.
Please pay attention to the room
temperature and air flow
direction when operating
the unit for baby, children
and old folks who have
difficulty in movement.
The Air Conditioner And The Heat Source In The Room
Caution
If the amount of heat in the room is above the cooling capability of the air
conditioner (for example: more people entering the room, using heating
equipments and etc.), the preset room temperature cannot be achieved.
When Lightning Occurs
Warning
To protect the whole unit during lightning, please stop operating the unit
and remove the plug from the socket.
Caution
Do not close the room for a long
period of time. Occasionally open the
door and windows
to allow the entrance
of fresh air.
RA-13JF2_EN 29/09/2006, 09:19 am6
– 7 –
If the air filter is clogged with dust, the air flow volume will decrease and resulting in poor
cooling performance, and increased operating noise. Be sure to clean the filter about every
20 days.
1 Remove the suction grille by pulling at both
bottom corner and then lift it up slightly before
pull downward to unhook the suction grille.
2 Lift and unhook the bottom of the air filter and
remove it.
3 Remove dust from the filter by using a vacuum
cleaner. If the filter is very dirty, wash it with
detergent and rinse properly with water. Dry it
with soft cloth and do not expose it to heat or
under direct sunlight.
4 Install the filter by fitting the top hooks and then
hook the bottom of the filter.
5 Attach the suction grille back to its place by
hooking at the top side to the front cover, then
gently push at both bottom corner.
MAINTENANCE
CAUTION
ALWAYS TURN OFF AND UNPLUG BEFORE ANY CLEANING
OR MAINTENANCE TO ENSURE SAFETY.
SUCTION
GRILLE
HOOK
AIR FILTER
CAUTION
Do not use hot water above 40°C for cleaning the filter.
Do not operate the air conditioner with the filter removed.
RA-13JF2_EN 29/09/2006, 09:20 am7
– 8 –
FRONT COVER AND SUCTION GRILLE
Clean the front cover and suction grille with a soft dry cloth. When it is excessively dirty, wipe
it with a soft cloth dampened with mild soap, then wipe it again thoroughly with a soft dry
cloth.
The suction grille can also be removed and be washed with water and mild soap. Remove
the suction grille in the following manner.
1 Pull the suction grille at both bottom
corner and released it.
2 Lift up the suction grille slightly.
3 Remove the suction grille by pulling
downward to release it from the hook
hole located at the top side.
CAUTION
Never use hot water above 50°C, erosive chemicals or brush to clean the front cover and
suction grille because they will damage the plastic surface.
BEFORE ASKING FOR SERVICE
Check the following items before asking for service. If the malfunction persists,
please contact service centre.
Symptom Cause
Does not operate 1 Is the power cord loosened or unplugged?
at all 2 Is the fuse blown out or the circuit breaker tripped?
3 Is the voltage normal?
4 Is the main switch set to “OFF” position?
Poor cooling 1 Is the air filter covered with heavy dust?
performance Clean the filter and replace it.
2 Is the temperature setting correctly?
3 Is the sunlight fall directly in the air conditioner?
4 Is the air flow on the rear side (outdoor) blocked?
Leave a space of 900 mm (3 feet) behind the rear side of air
conditioner.
5 The doors or windows may be opened widely or there are
other sources of heat in the room.
6 Is the ventilation damper opened?
CAUTIONS
IF THE POWER SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE ONE
SPECIALLY PREPARED AND ONLY AVAILABLE FROM THE MANUFACTURER OR ITS
SERVICE AGENT.
RA-13JF2_EN 29/09/2006, 09:20 am8
– 9 –
5mm
130mm
-5~5mm
390mm
385 - 395mm
570 - 585mm
Over
100mm
Over 150mm
Over
1200mm
Over
900mm
Over 200mm
Over
200mm
Over
200mm
Wall
Indoor
Side
Outdoor
Side
Wall or
obstacle
Floor
Side View
Back View
Screw
INSTALLATION INSTRUCTIONS
REMOVE ALL THE SHIPPING PARTS BEFORE
INSTALLATION AND CONSULT YOUR DEALER
CONCERNING INSTALLATION REQUIREMENTS.
Select a location that can support the weight of the air conditioner and will not cause
increased operating noise and vibration.
Select a location where direct sunlight does not fall on your air conditioner.
Select a good location for efficient air circulation.
Select a place where there is no obstacles near the air inlet and outlet.
CAUTION
The installation material must be fully strong against corrosion, especially in case the air
conditioner to be installed near the sea or hot spring.
Do not install air conditioner in the places where there is a possibility of inflammable gas
leaks.
Secure tightly the cabinet with screws. Otherwise there may be danger of the air conditioner
dropping.
Please keep the recommended installation dimensions. Otherwise waterdrops may occur.
LOCATION
RA-13JF2_EN 29/09/2006, 09:20 am9
– 10 –
POWER SOURCE
Check the capacity of wiring and power outlet. The power outlet should be used exclusively
for the air conditioner. Do not use it with other appliances. Any wiring must follow the
national wiring regulation.
Ground the air conditioner to prevent danger of electric shock.
Connect the air conditioner with power source securely.
Use a fuse as below:
Voltage rating 50Hz 220-240V
Operatable
50Hz 198-264V
Voltage range
CAUTION
WARNINGTHIS APPLIANCE MUST BE EARTHED.
REMOVE THE FRONT COVER
Remove the front cover in the following manner.
1 Pull the suction grille at both bottom corner
and release it.
2 Remove the air filter.
3 Remove two screws which secure the front
cover.
4 Remove the front cover from lower side.
Disconnect the timing motor connector at
right side of the electrical box.
Electrical box
Connector
15A time delay fuseRA-13JF2
RA-13JF2_EN 29/09/2006, 09:20 am10
– 11 –
SLIDE OUT OF UNIT
1 Remove the four screws which fasten the
base pan to the cabinet at the side and back.
2 Remove the stopper at front left side of base.
3 Slide out the unit by pulling the handles.
After slide in the unit, please install the sealer
between the base pan and cabinet to prevent
from entering rain water in case of typhoon.
Fasten the unit to cabinet at the side with the
screw, then refit the front cover.
POWER CORD ARRANGEMENT
If power cord is withdrawn from left side
of unit, please arrange the power cord
as in figure after installing the front
cover.
DRAIN PAN
CONDENSED WATER DRAINAGE
This air conditioner employs a “turbo fan splashing ring” which is designed to splash the
condensated water on the condenser surface for maximum cooling efficiency, thus producing
a splashing sound.
If you are uncomfortable with the sound, you can install an
outside drainage by using the following procedure which may,
however cause a small loss of performance.
1 Remove the rubber plug from the base pan.
2 Install the drain pan by using 2 pieces of screws (provided)
at the cabinet.
3 Connect the drain pan with the drain hose. (Drain hose or
tubing can be purchase locally to satisfy your particular needs.
Drain hose inner diameter size should be around ø13mm or
1/2 inch.)
4 Slide the air conditioner unit back into the cabinet.
When the screws at the both side of the cabinet cannot be fasten, please use the stopper to fix
the cabinet and the base pan located at in front of the unit.
STOPPER
Drain hose
Rubber plug
Screws
Drain pan
Cabinet
Sealer
Handles
Stopper
AUTO SWING
MAIN SWITCH TEMPERATURE
WAIT 3 MINUTES
BEFORE
RESTARTING
CAUTION
ON
OFF
OFF
TEST
COOLER
QUIET FAN
HI FAN
HI COOL
QUIET COOL
10
98
7
6
5
4
20mm
or more
20mm
or more
Fix the power
cord with the
band.
RA-13JF2_EN 29/09/2006, 09:20 am11
– 12 –
MEMO
...........................................................................................................................................................
...........................................................................................................................................................
...........................................................................................................................................................
...........................................................................................................................................................
...........................................................................................................................................................
...........................................................................................................................................................
...........................................................................................................................................................
...........................................................................................................................................................
...........................................................................................................................................................
...........................................................................................................................................................
...........................................................................................................................................................
INSTALLATION WORK INSPECTION CHECK LIST
Item
Check Item Initials
No.
1 Have you removed the shipping parts? Please check
the caution sheet which is attached at front cover.
2 Is the incline of room air conditioner regarding
front and rear, right and left all right after
installation?
3 Is the strength of installation sufficient?
4 Have you grounded your room air conditioner?
5 Have you fastened the unit to the cabinet?
6 Have you done a test operation, and are there
any abnormal phenomena?
CAUTION
BEFORE START OPERATION OF AUTO SWING FUNCTION, PLEASE TURN THE RIGHT
VERTICAL DEFLECTOR TO THE MOST RIGHTWARD AND SWITCH ON THE AUTO SWING
SWITCH TO CHECK THE VERTICAL DEFLECTOR MOVEMENT.
THE ABNORMAL SOUND WILL OCCUR DURING VERTICAL DEFLECTOR ADJUSTMENT
AND IT DOESN'T AFFECT THE AUTO-SWING OPERATION.
DURING USAGE IF THE VERTICAL DEFLECTOR CHANGES ANGLE THEN PLEASE DO
THE ABOVE SETTING AGAIN.
RA-13JF2_EN 29/09/2006, 09:20 am12
– 13 –
安全上應特別注意之事項
使用前,請詳細閱讀「安全上的注意事項」,以正確的使用機體。
在所示注意事項的 警告”、“ 注意需特別加以注意。“警告”欄中記載之事項,表示處理錯誤時,
可能會造成死亡或重傷,而“注意”欄中記載之事項,因狀況也可能造成重大之後果,所以請務必遵守,以
維護安全。
另外圖像中的 表示禁止事項。
閱讀完後,請務必妥善保管。
安裝上的注意事項
警告
安裝時,請委託經銷商或專門技術人員安裝。
自己安裝可能會造成漏水、觸電及火災。
請使用接地線。
地線請勿安裝在瓦斯管、水管、避雷針、電話之地線等場所。
依設置場所狀況,有必要安裝漏電斷電器。
如沒有安裝漏電斷電器時,會有觸電的危險。
不可安裝於有可燃氣體的場所,因為萬一氣體泄漏在機體周圍的
話,可能會發生火災。
安裝排水管時,請確認水可否順利的流出。(排水管型
注意
搬移或修理時的注意事項
警告
異常時(有焦味等),請停止運轉後把斷電器關閉,並通知經銷服務人
員。有異常而照舊連續運轉的話,會造成故障、觸電、火災等。
維修時,請直接向經銷服務人員接洽。
自己修理不完全的話,會有觸電、火的危險。
機體要移動重新再設置時,請直接向經銷服務人員接洽。
自己移動機體,重新再設置時,若安裝不安全的話,就會有觸電、火的危險。
使用上的注意事項
身體請勿長時間直接對著冷氣,以免妨礙健康。
請勿將細棒等物品插入吹出口及吸入口,由於風扇在高速運轉,易造成危險。
請勿以金屬或銅線當作保險絲,以免發生故障或火災。
有打雷之可能時,為了保護機械,請停止運轉,並把斷電器關閉,以避免故障發生。
本機請使用在以一般家庭的人為對象的場所,請勿使用在保存食品、動植物、精密機
器、美術品、醫藥品等特殊場所。
請不要用濕手來操作開關,以免觸電。
與燃燒器具一起運轉時,請常換氣,否則會有氧氣不足的情形。
本機所吹出來的風,請不要直接吹在燃燒器具上,否則,會使燃燒器具燃燒不完全。
長期使用的安裝材料請隨時注意其是否穩固,不可有損傷的情形。否則機體可能會落
下造成危險。
清洗機體時,請絕對避免用水潑機體,因會有漏電的危險。
動植物請不要放置在風向直接吹到的場所,否則會對動植物有不良的影嚮。
清潔機體時,請停止運轉並把斷電器關閉。因為機體內部的風扇正以高速運轉,會造
成傷害。
長時間不運轉時,為了安全起見,請把斷電器關閉。
請勿爬上機體,物品也不要放在機體上面。
機體上請不要放有水的容器(如花瓶),以免傾倒流入機體內部,會使機體內部
電氣絕緣劣化,產生觸電的危險。
冷氣運轉時,窗和門在開放的狀態下,風向板向下時,都請不要長時間運轉,否則上下風向板
會結露,有時會滴下來,而使傢俱弄濕。
房間如果有超過冷氣能力的熱源(如房間有多人進入,使用熱器具等),將無法達到所設定室溫。
RA-13JF2_CH 29/09/2006, 09:21 am13
– 14 –
部件名稱及操作
1 機箱
2 吸氣柵
3 水平風向調整板
4 垂直風向調整板
5 排氣桿
6 前面蓋
7 控制板蓋
控制板
1
自動搖擺
2 操作選擇鈕
3 定溫器鈕
操作模式選擇鈕
OFF 停止風扇及冷卻操作。
QUIET FAN 冷氣機將只在低速度的風扇操作。
HI FAN 冷氣機將只在高速度的風扇操作。
QUIET COOL 在低風扇速度下進行冷卻操作。這特別供舒適安眠時使用。
HI COOL 在高風扇速度下進行冷卻操作以便達到最大冷卻功能。
自動搖擺
當自動搖擺鈕被調到‘ON’時,垂直調整板將自動游移左右則輪流排掃出舒適的涼
風。
只要自動搖擺鈕被調到‘OFF’時,垂直調整板將會停留在任何位置。
開始操作時會發出異聲(超速聲)但不會影嚮操作功能。
1
2
3
4
5
7
AUTO SWING
WAIT 3 MINUTES
BEFORE
RESTARTING
CAUTION
QUIET FAN
ON
OFF
HI FAN
TEST
COOLER
HI COOL
OFF
QUIET COOL
TEMPERATUREMAIN SWITCH
1
2
3
4
5
9
8
7
6
10
123
6
22
1
/
16
"
, 560mm 14
3
/
4
"
, 375mm 28
1
/
8
"
, 714mmRA-13JF2
型號
寬度
長度高度
RA-13JF2_CH 29/09/2006, 09:21 am14
– 15 –
定溫器鈕
設定所希望的室內溫度。越是順時針旋轉此開關,室內將越涼爽。
如把此開關設定於TEST(試驗)的位置,壓縮機將連續地操作。此
設定是供服務人員使用,若冷氣機在此設定下操作,蒸發器可能結冰而
造成水滴或其他故障。對於日常的使用請不要把定溫器鈕設於“TEST”
的位置。
冷卻操作中如向反時針方向轉動定溫器鈕而停止壓縮機時,必須等候 3
鐘後才可以將定溫器鈕向順時針方向旋轉以開動壓縮機。
風向調整板
水平風向調整板
水平調整板兩邊的吹出口可將風向設於上、
下或直面排風。
垂直風向
調整板
垂直風向
調整板
水平風向
調整板
水平風向
調整板
為了避免露水滴在調整板上,請勿長時間在冷卻操作下把水平調整板調得太低或者把
垂直調整板向左右極端擺動。
況且,不能用手或其他物件去調垂直風向調整板的位置。
排氣桿
把排氣桿設在開(拉出),以便循環室內空
氣。在冷卻操作及颱風時,排氣桿應設在
(推進)關。
排氣桿
垂直風向調整板
垂直調整板兩邊的吹出口可調置於自動掃
蕩或靜止狀態
將風向設於右、左或直面
排風。
RA-13JF2_CH 29/09/2006, 09:21 am15
– 16 –
空氣濾清器
安裝濾清器前必須要停止操作。
1. 打開吸氣柵
2. 拿掉普通隔濾網
3. 安裝空氣濾清器在框架內
4. 裝回普通隔濾網及關上吸
氣柵
操作注意
溫度及濕度
避免在室外氣溫低於攝氏 21度(華氏 70度)時,使用此冷氣機作為冷卻操作。建議操
作濕度為 80%以下,長時間在 80%(室內)濕度以上操作,將造成少許露水在出風口柵
格形成。
噪音
在穩靜操作期間,或當停止運轉時,有時會聽見冷凍劑流動的微小聲音和風扇罩受熱或
受冷時所發出的微小摩擦聲。但這些都是正常的現象。
在蒸發器上凝結的水將收集在底盤裡,冷凝器的風扇將水帶上並噴向冷凝器。這將造成
“噴射”的正常水聲。
異味
冷氣機有時會發出異味,特別是在開機初時及高潮濕的環境下,但這並非不正常的現
象,而是因為煙,食物,化妝品等所發出的異味附著在上面的緣故。所以在長期停用後
而再想使用時,最好清理空氣隔濾網和蒸發器部份以減少臭味。
用吸塵機或清水將空氣濾清器清洗,它可被再用多達二十次。
空氣濾清器應每個月或當灰塵累積時清洗。如果使用過期,僅有可能失去除臭功能。
3 6個月更換濾清器一次或視施用需求而定以達到最佳功效。
空氣濾清器型號為下圖:
更換時請使用此型號向經銷店購買。
空氣濾清器
型號
制品號
RA-13JF2 SPX-CFH8W
RA-13JF2_CH 29/09/2006, 09:21 am16
– 17 –
最佳的使用方法
室溫設定要適當 裝置窗簾或百葉窗
可隔絕從窗
戶進來的熱
源。
換氣
為了嬰兒及小孩,
請注意室溫調節
濾網請不要忘記清洗
濾網的網目塞住會影響風
量,減弱冷氣效果,為了不
浪費電力,請
每隔 2週務必
清洗一次。
行動不便的嬰兒、小孩、老
年人等使用冷氣機時,
請注意室內溫度及
風向的調節。
顧客須知
冷氣和房間的熱源
有打雷之虞時
警告
過冷對健康不好
且會浪費電力。
注意
房間如果有超過冷氣能力的熱源(如房間有多人進入,使用
熱器具等),將無法達到所設定的室溫。
警告
有打雷之虞時,為了保護機械而需停止運轉,請把電源插頭
拔起來。
注意
房間不要關閉太久,請偶爾
打開窗戶,換新
鮮空氣。
RA-13JF2_CH 29/09/2006, 09:21 am17
– 18 –
若空氣隔濾網沾滿灰塵,吹出風量將減少而造成冷卻功能減低,及增大操作噪音。請確
保每 20天清理隔濾網一次。
1 在吸氣柵兩邊的下端一拉,然後稍微提起吸
柵直至將吸氣柵取出。
2 提起空氣隔濾網下端後把它拿出。
3 用吸塵機清除網上的灰塵。若隔濾網太過骯
髒,用少許清潔劑清洗及用水完全洗淨,用柔
軟布弄乾,不可接觸高溫或受陽光直曬。
4 把隔濾網裝回在上端及下端的架鉤上。
5 把吸氣柵上端向前面蓋繫上,再輕輕把吸氣柵
下端左右一按以關上吸氣柵。
維修保養
清掃之前請務必關掉操作開關及拔掉電源插頭,以確保安全。
空氣隔濾網
不可用 40℃以上的水來清洗。
在隔濾網拿掉下,不可操作冷氣機。
吸氣柵
RA-13JF2_CH 29/09/2006, 09:21 am18
– 19 –
前面蓋和吸氣柵
請用柔軟乾布擦抹前面蓋。如果它過度骯髒,請用沾以溫水及中性洗潔劑的軟布擦抹,
然後用柔軟的乾布完全抹乾。
吸氣柵也可拆出來清洗。請按照下例方法拆出吸氣柵。
1 在吸氣柵下端左右角一拉
後放開。
2 稍微提起吸氣柵。
3 稍微在吸氣柵上端的架鉤
向內一推後拆出它。
請勿用 50℃以上的熱水、化學劑或刷子來清洗前面蓋及吸氣柵,因為它們將會損壞塑膠
表面。
要求服務之前
在要求修理或服務之前,請先檢查下列各點。如果故障依舊,則請洽詢維修服務中心。
問題 原因
無法運行 1 電源軟線是否鬆了或插頭沒插好?
2 保險絲是否熔斷或斷電器是否跳掣?
3 電壓是否正常?
4 電源開關是否設在“OFF”的位置?
冷卻效果不佳 1 空氣隔濾網是否太髒?
清洗隔濾網後裝回它。
2 設定溫度是否適當?
3 陽光是否直射在冷凝器上?
4 室外的空氣流通是否受阻?
900mm(3 的空間在冷氣機的後部。
5 房間或窗口是否開著或是否室內有其他熱源?
6 排氣蓋是否開著?
如果電源軟線損壞,必須使用由製造商或其服務店所特別預備及提供之軟線。
RA-13JF2_CH 29/09/2006, 09:21 am19
– 20 –
5mm
130mm
-5~5mm
390mm
385 - 395mm
570 - 585mm
100mm
以上
150mm 以上
1200mm
以上
900mm
以上
200mm
以上
200mm
以上
200mm
以上
牆壁
室內
室外
牆壁
或圍牆
地面
側視圖
背面圖
螺絲
安裝方法
安裝前請拆除裝運用的部件及向經銷店諮詢有關安裝的需要。
地點
選擇一個能夠承受冷氣機的重量且不會增加操作噪音和震動的地點。
選擇一個沒有陽光直射在冷氣機的位置,建議地點是北、東面。
選擇一個通風良好的位置以增加冷氣效率。
選擇一個在空氣吹出口或吸入口附近沒有遮擋物的地點。
注意
安裝用部件應是高耐蝕性材料,特別是當冷氣機安裝在靠近海邊或溫泉附近時。
會漏出可燃性氣體的地方切勿安裝冷氣機。
用螺絲將機箱鎖緊。否則可能有冷氣機跌下的危險。
請確保按照所提供的尺寸來安裝。否則可能發生滴水現象。
RA-13JF2_CH 29/09/2006, 09:21 am20
1 / 1

Hitachi RA-13JF2 Operation and Installation Manual

カテゴリー
スプリットシステムエアコン
タイプ
Operation and Installation Manual

他の言語で