ICP A-626S Quick Start

タイプ
Quick Start

このマニュアルも適しています

- 1 -
Language English
Version V1.2
Update Jun.2009
………………………………………………
What’s on your package?
¾ One A-626/628 series card
¾ One companion ISA CD (V2.1 or later)
¾ One Quick Start Guide(This document)
………………………………………………
Installing Windows Driver
Follow these steps:
1. Set up the Windows driver.
The driver is location at:
CD:\NAPDOS\ISA\A626_628\DLL_OCX\
http://ftp.icpdas.com/pub/cd/iocard/isa/napdos/isa/a626_628/dll_ocx/
(The Windows NT driver have support the Windows 2K and windows
XP/2003/Vista 32bit version.)
1
2
A
-626/628
- 2 -
2. Click the button to start the installation.
3. Click the
button to install the driver into the
default folder.
4. Click the
button to continue the installation.
5. Select the “NO, I will restart my computer later” and
then click the
button.
………………………………………………
I/O Base Address/Interrupt Setting
¾ The base address is set from SW1 DIP switch on board:
3
The Windows driver only supports Windows 98/NT/2000
and XP/2003/vista 32-bit versions.
SW1
ON
1 2 3 4 5 6
A8 A7 A6 A5 A4 X
SW1 Value Table
1 2 3 4 5
I/O Address
A8 A7 A6 A5 A4
200-20F ON ON ON ON ON
210-21F ON ON ON ON Off
.
2C0-2CF(*) ON Off Off ON ON
2D0-2DF ON. Off Off ON Off
.
3F0-3FF Off Off Off Off Off
(*):Default setting
A
-628A-626
SW1
ON
1234
A8 A7 A6 A5
SW1 Value Table
1 2 3 4
I/O Address
A8 A7 A6 A5
200-21F ON ON ON ON
220-23F ON ON ON Off
.
2C0-2DF(*) ON Off Off ON
2E0-2FF ON Off Off Off
.
3E0-3FF Off Off Off Off
(*):Default setting
- 3 -
¾ The Interrupt Level Setting
………………………………………………
Installing Hardware on PC
Follow these steps:
1. Shut down and power off your computer
2. Remove the cover from the computer
3. Select an unused ISA slot
4. Carefully insert your I/O card into the ISA slot
5. Replace the PC cover
6. Power on the computer
After powering-on the computer, continue next process.
4
- 4 -
………………………………………………
Pin Assignments
5
- 5 -
………………………………………………
Self Test
1. A-626 user can use CA-2002(Optional) to connect
the CN3 with CN4.
A-628 user can use CA-2002(Optional) to connect
the CN2 with CN3.
2. Execute the A626/628 sample program.
Get the file from(default path):
C:\NAPDOS\ISA\A626_WinXX\demo\
6
CN1
CN2
CN3
P1
CN3
CN4
CA-2002
CA-2002
- 6 -
3. Check the board number of the A-626/628, and
test DIO functions.
4. Get DIO function test result.
1:
Setting the I/O
Base Address
(Default : 2C0)
2:
Click this button
to do DIO test.
Check the Bit 0,2,4,6 CheckBox.
Bit 0,2,4,6 are all Red light.
Complete
- 7 -
………………………………………………
Additional Information
9 A-626&A-628 Card Product page:
http://www.icpdas.com/products/DAQ/pc_based/a-626&8.htm
9 CA-2002(Optional) page:
http://www.icpdas.com/products/Accessories/cable/cable_selection.htm
9 Documentation:
CD:\NAPDOS\ISA\A626_628\manual
CD:\NAPDOS\ISA\Manual
http://ftp.icpdas.com/pub/cd/iocard/isa/napdos/isa/a626_628/manual/
9 Software:
CD:\ ISA\NAPDOS\ISA\A626_628
http://www.icpdas.com/download/isa/a626_628/index.htm
The ICP DAS Web Site
http://www.icpdas.com
Contact Us
Copyright ©2009 by ICP DAS Co., Ltd. All rights are reserved
7
Technical support
Supplies and ordering information
Methods of enhancing your device
FAQ
Application examples
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

ICP A-626S Quick Start

タイプ
Quick Start
このマニュアルも適しています

他の言語で