© 2004 Matsushita Electric Industrial Co., Ltd. All Rights Reserved.
Plasma Display Fan Kit for Vertical Use
Installation Instructions
TY-UPK42HV7
TY-UPK50HV7
Before commencing work, carefully read these Instructions and the Manual for the plasma display to ensure that
fitting is performed correctly.
(Please keep these instructions. You may need them when maintaining or moving.)
Model No.
TQZH612
Thank you very much for purchasing the Plasma Display Fan Kit for Vertical use.
Installation work should only be carried out by a qualified technician.
• If the unit is installed incorrectly, the display may fall down and personal injury may result.
Precautions with regard to setting up
WARNING
Always have a qualified technician perform the installation.
The internal components of the display may be hot and cause burns. If the product is not
correctly installed and adjusted, damage may result to the product.
Make sure that all safety factors regarding strength of installation are observed.
If the installation strength is insufficient, the display may fall down and personal injury may
result.
Do not install in places which are unable to bear loads.
If the strength of the installation surface is insufficient, the display may fall down and personal
injury may result.
Caution
Do not install in places which are subject to humidity, dust, oil fumes, water vapor or
excessive heat.
These can have adverse effects on Wide Plasma Display operation, and fire or electric shocks
may result.
Do not install the Plasma Display face up, sideways or upside down.
• Doing so may cause heat to build up inside the display, and fire may result.
Two people are required to install and remove the display.
• If two people are not present, the display may be dropped, and personal injury may result.
Maintain a space of at least 10 cm 3
15
/
16 inches at the top, bottom and sides of the
display, and at least 1.9 cm (
3
/4 inches) at the rear of the display.
• The display has air outlet holes at the top and air intake holes at the bottom and rear. These
holes must not be covered, otherwise fire may result.
2
33
Components
Fan 1
TY-UPK42HV7 (For TH-42PHD7)
TY-UPK50HV7 (For TH-50PHD7)
Points to note during installation
This optional fan kit is designed exclusively for vertical use with this display model.
In order to ensure correct, problem-free operation of the Plasma Display, do not
install the Display in any of the following places.
• Places which are next to sprinklers or sensors
• Places which are subject to vibration or shocks
• Places which are close to high-voltage wires or electric motors
• Places in direct contact with air from heaters
When installing the wall-hanging bracket unit, use a mounting method appropriate
to the type of wall.
This kit does not include the bolts needed to mount the bracket to the wall. Please
purchase screws suitable for the material (wood, steel frame, concrete, etc.) of the
wall on which the bracket and Plasma Display are to be mounted.
Install so the screws and power cord do not touch metal parts of the wall.
Insert the power cord plug for the Plasma Display into a wall outlet which is close
and easily accessible.
Provide adequate ventilation so that the temperature around the display does not
rise above 35
. If there is insufficient movement of air inside the display, heat may
build up inside the display, and fire may result.
To set the display up vertically, you will also need the TY-WK42PV1 or TY-WK42PV7
vertical wall bracket.
After installing the fan kit for vertical use and before attaching the back cover, do
the following to avoid smoke, fire, or electric shock.
• Check that all wiring is as directed.
• Ensure screws and other metal objects are not inside the kit.
Fan mounting screw (M3) 3 Lead clamper 1 (Only TY-UPK42HV7)
Fixing screw (M5) 2
4
Attach the fan
a
a
a
a
b
c
b
b
b
Remove bolts and screws (a, b, c)
from the display.
Put the rear cover and removed bolts
and screws to the side where they will
not get lost.
1) Remove the rear cover from the display.
Place the display facing downward on a clean blanket or the like, and follow the steps below.
2) Attach the fan
Be sure to position the fan correct in the display.
Caution
TH-42PHD7
a
a
a
a
b
b
b
b
c
TH-50PHD7
TH-42PHD7
TH-50PHD7
a
b
c
a
b
c
Before installing the Vertical-Mount Fan
Kit on the display, pass the lead of
connector SC46 through the lead
clamper on the fan kit (TH-42PHD7
only).
Install the fan at the locations shown in
the figure on the left, using supplied
mounting screws (M3).
SC46
Clampers
5
Clampers
Fan A
Clampers
Supplied lead clamper
Fan lead
Horizontal barFan A
B
TH-42PHD7
TH-50PHD7
3) Attach the connectors
4) Reattach the rear cover and insulating spacer
Install the four locations
Fixing
Remove the short coupler Z32.
Secure the fan lead with the lead clamper
located to the left of Fan A.
Secure the fan lead at position B with the
supplied lead clamper.
Secure the fan lead together with nearby wires
with lead clampers.
* Route the lead under the fan along the
horizontal bar. (Be sure to secure the lead so
that it cannot be trapped by the fan.)
Connect fan lead into connector Z32.
Remove the short coupler Z32 and Z33.
Secure the fan leads with the lead clamper
located to the left of Fan A.
Secure the fan leads together with nearby
wires with lead clampers.
Connect fan lead into connector Z32 and Z33.
Reverse the steps given above for removing
the cover.
Install the four pan head bolts ( ), toothed
pan washers ( ) and insulating spacers ( )
that came with TY-WK42PV1 or TY-
WK42PV7.
Install the remain screws.
Pan head bolt with hex socket
Toothed pan washer
Insulating spacer
Allen key
6
Install the wall-hanging bracket
The wall-hanging bracket TY-WK42PV1 weights
approx. 6 kg (13.2 lbs.), TY-WK42PV7 weights
approx. 3 kg (6.6 lbs.), a 50-inch display weights
approx. 45 kg (99.2 lbs.), a 42-inch display weights
approx. 30 kg (66 lbs.). Using the bracket
dimensions shown in the diagram at left, confirm
that the 6 locations for mounting the bracket to the
wall are able to bear the combined weight. If the
wall is not strong enough, reinforce it.
1) Check the strength of the installation location.
If it is necessary to embed bolts or nuts beforehand
because the wall is made of concrete, use the
bracket itself to determine the correct installation
hole positions, or use the dimension diagram to
calculate the hole positions. Then embed the M6
bolts or nuts into the holes. Embed the bolts so that
they protrude from the wall by 10 mm (
13
/32 inch) to
15 mm (
19
/32 inch).
2) Install the wall-hanging bracket to the wall.
The wall-hanging bracket has 24 installation holes for
TY-WK42PV1 and 14 installation holes for TY-
WK42PV7.
If the wall material is not strong enough to install the
display using six installation holes, use some of the
spare holes. However, depending on the wall material,
cracks may develop and attachment intensity becomes
inadequate if the screws are inserted too close to each
other.
Caution
Units: mm
( ): inch
Units: mm
( ): inch
Fixing screw
Arrow
Fixing screw
Marks (V)
(Dimensions of the
TY-WK42PV1)
For TY-WK42PV1
For TY-WK42PV7
(Dimensions of the
TY-WK42PV7)
Use commercially available bolts which suit the wall
materials for installation to the wall.
Caution
Installation procedure
Insert a bolt into the upper right hole.
Use a level to adjust the bracket so that it is parallel
to the ground. Insert bolts into the other 5 holes.
Insert and slightly tighten the fixing screw (M5 x
35). Do not insert the bolt more than 5 mm (
13
/
64
inch). The display cannot be installed in the
correct position if the bolt is over-tightened.
* Note: In this case, the wall-hanging bracket fixing
screw (M5 x 135) is not used.
Hang the bracket
so that the arrow
on the bracket
points to the right.
Hang the bracket
so that the marks
(V) on the bracket
points to the top.
7
Installation procedure
Push the upper insulating spacers on the display
into the notches at the top of the wall-hanging
bracket until they are hooked in, then lower the
display into place.
While lifting the display slightly, insert the lower
insulating spacers on the display into the lower
hanging holes in the wall-hanging bracket, then lower
the display.
3) Install the display to the wall-hanging bracket.
Position the display so that the power switch is located at the bottom.
Insulating spacer
Top holes
Lower
holes
Power
switch
• Tighten the fixing screws on the left side.
4) Tighten the fixing screws.
Screws locations
(upper and lower)
(Left side view)
Do not lift the display too high, otherwise it may become
unhooked.
Note
Be sure to fix the left side fixing screws to stabilize the
display.
Caution
For TY-WK42PV1
For TY-WK42PV7
8
Setting the fan motor software
1) Power on the display and press button on
the remote control.
The [SET UP] menu will appear.
2) Press buttons and select [OSD LANGUAGE]
menu then press button on the
remoto control for at least 3 seconds.
The [Options] menu will appear.
3) Press buttons on the remoto control and select
[V. Installation], then press buttons on the
remote control to change [Off]
[On].
(V. Installation menu exist on 2/2 at option menu.)
4) Turn the power off by pressing the power button on
the dispiay or remoto control.
5 ) Power on the display.
Finish the setting.
SURROUND
SETUP
[Options] menu
[SET UP] menu
INPUT
SURROUND
VOL
N R
PICTURE
SOUND SET UP
Be sure to complete vertical mount settings by following the steps below:
Set fan speed to maximum with the vertical mount setting option.
9
Wall-hanging bracket installation example for vertical use
450 (17
23
/32)
20
(
25
/32)
B
900 (35
7
/16)
A
A
930 (36
5
/8)
G
19 (
3
/4)
G
20 (
25
/32)
FE
C
490 (19
19
/64) D
C
516 (20
5
/16) D
775 (30
33
/64)
FE
745 (29
21
/64)
480 (18
57
/64)
18
(
45
/64)
B
Units : mm
( ) : inch
For 50 Inch For 42 Inch
Dimensions
A
B
C
D
E
F
G
1210 (47
41
/64)
724 (28
1
/2)
136.5 (5
3
/8)
97.5 (3
27
/32)
128.5 (5
1
/16)
151.5 (5
31
/32)
95 (3
47
/64)
1020 (40
5
/32)
610 (24
1
/64)
79.5 (3
1
/8)
40.5 (1
19
/32)
33.5 (1
5
/16)
56.5 (2
7
/32)
89 (3
1
/2)
For 50 Inch
TY-WK42PV1 TY-WK42PV7
For 42 Inch
1210 (47
41
/64)
724 (28
1
/2)
116.5 (4
19
/32)
91.5 (3
39
/64)
207 (8
5
/32)
228 (8
31
/32)
95 (3
47
/64)
1020 (40
5
/32)
610 (24
1
/64)
59.5 (2
11
/32)
34.5 (1
23
/64)
112 (4
13
/32)
133 (5
15
/64)
89 (3
1
/2)
Units : mm ( ) : inch
TY-WK42PV1 TY-WK42PV7
Printed in Japan
M1004A0
(
MBS
)
(
Recycled paper
)
© 2004 Matsushita Electric Industrial Co., Ltd. All rights Reserved.
Matsushita Electric Industrial Co., Ltd.
Web Site : http://www.panasonic.co.jp/global/
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Panasonic TYUPK50HV7 取扱説明書

タイプ
取扱説明書
このマニュアルも適しています