– 3 –
7. Connect Network Cables
For RJ-45 ports, connect 100-ohm Category 5, 5e or better
twisted-pair cable.
For the SFP/SFP+ slots, first install SFP/SFP+ transceivers and
then connect fiber optic cabling to the transceiver ports.
The following transceivers are supported:
◆
10GBASE-CR
◆
10GBASE-SR
◆
1000BASE-SX
◆
1000BASE-LX
◆
1000BASE-T
As connections are made, check the port status LEDs to be
sure the links are valid. Press the Mode button to change
from Ethernet to PoE status:
◆
On/Blinking Green — Port has a valid link. Blinking
indicates network activity.
◆
On Amber — Port is supplying PoE power.
Hardware Specifications
Switch Chassis
Size (W x D x H)
28T: 44.0 x 22.0 x 4.4 cm (17.32 x 8.66 x 1.73 in)
28P: 44.0 x 33.0 x 4.4 cm (17.32 x 12.99 x 1.73 in)
28F/28F-I /28Fv2/28Fv2-I : 44.0 x 22.0 x 4.4 cm
(17.32 x 8.66 x 1.73 in)
52T: 44.0 x 28.0 x 4.4 cm (17.32 x 11.02 x 1.73 in)
Weight
28T: 2.47 kg (5.45 lb)
28P: 4.53 kg (10.0 lb)
28F/28F-I /28Fv2/28Fv2-I : 2.82 kg (6.22 lb)
52T: 3.76 kg (8.29 lb)
Temperature
Operating: 0° C to 50° C (32° F to 122° F)
Operating: -10° C to 65° C (14° F to 149° F,
ECS4120-28F-I and ECS4120-28Fv2-I only)
Storage: -40° C to 70° C (-40° F to 158° F)
Humidity Operating: 5% to 95% (non-condensing)
AC Input Power
28T: 100-240 VAC, 50/60 Hz, 0.37-0.22 A
28P: 100-240 VAC, 50/60 Hz, 4.6-2.1 A
28F/28F-I /28Fv2 : 100-240 VAC, 50/60 Hz 1 A
28Fv2-I : 100-240 VAC, 50/60 Hz 1.2 A
52T: 100-240 VAC, 50/60 Hz, 0.75-0.42 A
DC Input Power 28F: -48 – -60 VDC, 3.0 A
Max. Power
Consumption
28T: 20 W
28P: 460 W
28F/28F-I /28Fv2/28Fv2-I : 60 W
52T: 60 W
PoE Power
Budget
28P: 370 W
Regulatory Compliances
Emissions
EN 55022:2010, Class A
EN 55032:2012+AC:2013, Class A
EN 61000-3-2:2014, Class A
EN 61000-3-3:2013
FCC Class A
VCCI Class A
CE Mark
CCC GB 9254-2008 Class A
Immunity
EN 55024:2010
IEC 61000-4-2/3/4/5/6/8/11
Safety
UL (CSA 22.2 No 60950-1 & UL60950-1)
CB (IEC 60950-1/EN 60950-1)
CCC GB 4943.1-2011
Taiwan RoHS CNS 15663