test pen with the right hand and the negative pole
(like of the battery) with the left hand; use the
probe of the test pen to touch the positive pole(like
of the battery). If it is correct, the display screen
will display "— — P" and the buzzer will sound. If
it is connected reversely, the test pen will not
respond.
In general, when the backlight is red, it indicates
that the object under test may be dangerous
and should be operated carefully.
Warning
1:When using, please ensure that the human
body is insulated to the earth, please wear well-
insulated shoes; a certain part of the human
body contact with an electrified object, Large
areas of metal ,or the Earth, will affect the
accuracy of the measurement.
2:This product can only be used to measure
the AC voltage(≤300V 50/60Hz),such as other
processed power supply voltage, the
measurement deviation is large.
3:Due to the different structure of the socket,
when the zero and live wires cannot be
distinguished by the induction mode, it can be
switched to the AC voltage detection mode,
which can generally be distinguished according
to the voltage detected by the electric pen.
4:When the induction mode is used to
distinguish the zero and live wires: if the zero
and live wires are very close, separate the two
wires as far as possible for detection; if it is
impossible to separate them, distinguish them
according to the strength of the detected signal,
the one with strong signal is the live wire, and
the one with weak signal is the zero wire.
5:As the detector measurement requires
human contact to form a loop, please ensure
that your fingers can touch the detector keys
well.
6:Because the induction mode of the electric
pen has high sensitivity, it can sense the weak
electric field signal, so it is normal to trigger the
induction when the metal detector contact the
object with the weak electric field directly.
7:Do not use as a screwdriver.
Auto Power Off
After about 5 minutes without any operation and No
signal detection, the voltage detector will be
automatically shut down to extend the battery life.
Low Battery Indicate
When the battery voltage drops to less than 1.2
volts, the display will display " " symbol. When
low battery tip, please replace the battery.
Technical Specifications
Operating voltage:
AC voltage:12~300 V,50/60 Hz
Measurement error:±(5%+3)
Application environment:
Operating temperature: 0~40°C
Storage temperature: -10~50°C
Humidity:≤95%
Altitude:≤2000m
Safety Compliance:CAT.II 300V
Battery:1×1.5V AAA
Replace the Battery
Push off the battery cover as shown below, then
take out the old battery, and install the new battery
according to the positive and negative
indications of the battery.
Warning:
To avoid electric shock, do not use a voltage probe
to detect the voltage before the battery cover is
fastened and locked. \n In order not to affect the
detection, please ensure that the human body is
insulated from the ground.
Clean maintenance
Clean with a wet cloth.
Notes: After cleaning, the voltage detector can’t be
used until it is completely dry.
寶工實業股份有限公司
PROKIT’S INDUSTRIES CO., LTD
https://www.prokits.com.tw
©2023 Prokit’s Industries Co., LTD. All rights reserved
2023002